995 resultados para Implantation ionique


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cisplatin is one of the most widely used and effective chemotherapeutic agents for the treatment of several human malignancies. This study evaluated the effects of peri-pubertal cisplatin administration on several reproductive end-points and the reversibility of these effects in adulthood. Peri-pubertal Wistar male rats (45 days old) were divided into two groups: control (saline 0.9%) and cisplatin (1 mg/kg/day, 5 days/week, for 3 weeks, i.p.). The study was conducted in two steps and evaluations were performed at ages of 66 (post-pubertal age) and 140 (adult age) days on: (i) organ weights, serum gonadotropins and testosterone levels, sperm counts, motility and morphology, testicular histomorphometry, spermatogenesis kinetics, Sertoli cell number and in situ detection of apoptotic germ cells and (ii) sexual behaviour, fertility and intratesticular testosterone. At the end of cisplatin therapy, rats showed reductions in sperm production and reserves, sperm with progressive movement, tubular diameter, intratesticular testosterone and fertility potential, but increased numbers of TUNEL-positive seminiferous tubules, immotile sperm and pre-implantation losses compared with control. Moreover, cisplatin-treated post-pubertal rats displayed impaired testicular histopathology and sexual behaviour. Serum gonadotropins and testosterone levels, sperm morphology, spermatogenesis kinetics and Sertoli cell number were comparable between experimental groups at both ages. Alterations found in post-puberty were recovered at adulthood, except for sperm motility and damage to testicular histology. The persistence of these cisplatin effects, despite the unaltered fertility after natural mating in rats, may have implications for reproductive function of young boys undergoing cancer therapy, given the lower reproductive efficiency in human beings compared with rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

FAM is a developmentally regulated substrate-specific deubiquitylating enzyme. It binds the cell adhesion and signalling molecules beta -catenin and A-F-6 in vitro, and stabilises both in mammalian cell culture. To determine if FAM is required at the earliest stages of mouse development we examined its expression and function in preimplantation mouse embryos. FAM is expressed at all stages of preimplantation development from ovulation to implantation. Exposure of two-cell embryos to FAM-specific antisense, but not sense, oligodeoxynucleotides resulted in depletion of the FAM protein and failure Of the embryos to develop to blastocysts. Loss of FAM had two physiological effects, namely, a decrease in cleavage rate and an inhibition of cell adhesive events. Depletion of FAM protein was mirrored by a loss of beta -catenin such that very little of either protein remained following 72 h culture. The residual beta -catenin was localised to sites of cell-cell contact suggesting that the cytoplasmic pool of beta -catenin is stabilised by FAM. Although AF-6 levels initially decreased they returned to normal. However, the nascent protein was mislocalised at the apical surface of blastomeres. Therefore FAM is required for preimplantation mouse embryo development and regulates beta -catenin and AF-6 in vivo. (C) 2001 Elsevier Science Ireland Lid. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Regeneration of osseous defects by a tissue-engineering approach provides a novel means of treatment utilizing cell biology, materials science, and molecular biology. In this study the concept of tissue engineering was tested with collagen type I matrices seeded with cells with osteogenic potential and implanted into sites where osseous damage had occurred. Explant cultures of cells from human alveolar bone and gingiva were established. When seeded into a three-dimensional type I collagen-based scaffold, the bone-derived cells maintained their osteoblastic phenotype as monitored by mRNA and protein levels of the bone-related proteins including bone sialoprotein, osteocalcin, osteopontin, bone morphogenetic proteins 2 and 4, and alkaline phosphatase. These in vitro-developed matrices were implanted into critical-size bone defects in skulls of immunodeficient (SCID) mice. Wound healing was monitored for up to 4 weeks. When measured by microdensitometry the bone density within defects filled with osteoblast-derived matrix was significantly higher compared with defects filled with either collagen scaffold alone or collagen scaffold impregnated with gingival fibroblasts. New bone formation was found at all the sites treated with the osteoblast-derived matrix at 28 days, whereas no obvious new bone formation was identified at the same time point in the control groups. In situ hybridization for the human-specific Alu gene sequence indicated that the newly formed bone tissue resulted from both transplanted human osteoblasts and endogenous mesenchymal stem cells. The results indicate that cells derived from human alveolar bone can be incorporated into bioengineered scaffolds and synthesize a matrix, which on implantation can induce new bone formation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A partir de 1998, teve in??cio, na Secretaria da Fazenda do Estado de Pernambuco, o Programa de Moderniza????o Fazend??ria (Promofaz), que promoveu diversas mudan??as organizacionais, concentrando esfor??os em projetos estruturadores, incluindo investimentos no planejamento de tecnologia da informa????o (TI). Dentre os projetos de TI, destacou-se a elabora????o das arquiteturas de sistemas e tecnol??gicas. Neste trabalho, foi realizada uma revis??o dos processos organizacionais da moderniza????o fazend??ria, abrangendo aspectos de cultura, mudan??a e aprendizagem organizacionais, confrontados com referenciais hist??ricos e te??ricos, e maior enfoque na ??rea de tecnologia da informa????o. Apesar das dificuldades, o processo de informatiza????o tem provocado fortes impactos nos componentes culturais da institui????o. Sem a utiliza????o da tecnologia da informa????o como ferramenta, provavelmente n??o se implantariam os novos modelos de gest??o adotados pela Sefaz, mas se observou que a tecnologia, sozinha, n??o faz o milagre da mudan??a, sendo necess??rio todo um conjunto de esfor??os e um trabalho paralelo com outros fatores de mudan??a.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As organiza????es p??blicas e privadas vivem diante de um cen??rio complexo, em que os fatores econ??micos e sociais de alcance mundial s??o respons??veis pela sua reestrutura????o. Nesse contexto, a Gest??o do Conhecimento (GC) se torna um valioso instrumento estrat??gico para a vida das pessoas e das organiza????es a que pertencem. A cria????o e a implanta????o de processos que gerem, armazenem, gerenciem e disseminem o conhecimento representam o mais novo desafio a ser enfrentado pelas organiza????es. O estudo realizado junto a Centros de Pesquisa Cl??nica (unidades vinculadas principalmente a Hospitais Universit??rios) e organiza????es p??blicas de sa??de integrantes do Programa Nacional de Gest??o P??blica e Desburocratiza????o (GESP??BLICA) tem como objetivo verificar como o tema GC est?? sendo tratado. O artigo identifica as pr??ticas de GC empregadas pelas organiza????es de sa??de abrangidas pelo estudo e sugere recomenda????es para uma dissemina????o mais eficaz do Modelo de Excel??ncia em Gest??o P??blica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electroactivematerials can be taken to advantage for the development of sensors and actuators as well as for novel tissue engineering strategies. Composites based on poly(vinylidenefluoride),PVDF,have been evaluated with respect to their biological response. Cell viability and proliferation were performed in vitro both with Mesenchymal Stem Cells differentiated to osteoblasts and Human Fibroblast Foreskin 1. In vivo tests were also performed using 6-week-old C57Bl/6 mice. It was concluded that zeolite and clay composites are biocompatible materials promoting cell response and not showing in vivo pro-inflammatory effects which renders both of them attractive for biological applications and tissue engineering, opening interesting perspectives to development of scaffolds from these composites. Ferrite and silver nanoparticle composites decrease osteoblast cell viability and carbon nanotubes decrease fibroblast viability. Further, carbon nanotube composites result in a significant increase in local vascularization accompanied an increase of inflammatory markers after implantation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spheres of different types of material are used for the replacement of lost volume after removal of the eye bulb or its content to prevent contraction of the orbital cavity. The aim of this study was to evaluate the scope of polymethylmethacrylate (PMMA) used as intraocular implant in eviscerated rabbit eye. Twelve New Zealand rabbits underwent unilateral evisceration of the left eye, with subsequent implantation of PMMA sphere 12 mm in diameter. Clinical evaluation was performed daily during the first 15 days after surgery and every 15 days until the end of the study period (180 days). For the histopathological analysis, three animals per trial underwent enucleation at 15, 45, 90 and 180 days after evisceration. There was no wound dehiscence, signs of infection or implant extrusion in any animal throughout the study period. Histological examination revealed the formation of fibrovascular tissue around the implants. The PMMA behaved as inert and non-integrable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to evaluate the response to the implantation of synthetic hydroxyapatite 30% (HAP-91®) in different physical states as dermal filler. Eighteen New Zealand rabbits were used, distributed randomly into two equal groups and then divided into three groups according to the postoperative period at 8, 21 and 49 days. One mL of HAP-91®, fluid and viscous, was implanted in the subcutaneous tissue, 1 cm proximal to the cranial crest of the right scapula. The thickness of the skin was measured before and after implantation and for the following 15 days. Pain sensitivity assessment was conducted, assigning the following scores: 0 - when the animal allowed the touch of the implant area and expressed no signs of pain; 1 - when the animal allowed the touch, but pain reaction occurred, like increase of the respiratory rate or attempt to escape; 2 - when the animal did not allow the touch to the implanted area. At 8, 21 and 49 days, biopsy of the implanted area was performed. No difference was observed between the thickness of the skin (p>0.05) and all animals received a score 0 for soreness. Histological analysis did not reveal any obvious inflammatory process, showing a predominance of mononuclear cells in samples of eight days and tissue organization around the biomaterial with a tendency to encapsulation. The results indicate that HAP-91®, both viscous and fluid, is biocompatible and suitable for dermal filling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new circuit topology is proposed to replace the actual pulse transformer and thyratron based resonant modulator that supplies the 60 kV target potential for the ion acceleration of the On-Line Isotope Mass Separator accelerator, the stability of which is critical for the mass resolution downstream separator, at the European Organization for Nuclear Research. The improved modulator uses two solid-state switches working together, each one based on the Marx generator concept, operating as series and parallel switches, reducing the stress on the series stacked semiconductors, and also as auxiliary pulse generator in order to fulfill the target requirements. Preliminary results of a 10 kV prototype, using 1200 V insulated gate bipolar transistors and capacitors in the solid-state Marx circuits, ten stages each, with an electrical equivalent circuit of the target, are presented, demonstrating both the improved voltage stability and pulse flexibility potential wanted for this new modulator.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The benefits of cardiac resynchronization therapy (CRT) in the health-related quality of life (HRQL) are largely demonstrated in selected patients with severe congestive heart failure (CHF). However, the differences between responders and non-responders, with regard to the effect of CRT in the various dimensions that constitute HRQL are still a matter of discussion. Objective: To evaluate the impact of CRT on the HRQL of patients with CHF refractory to optimal pharmacological therapy, within 6 months after CRT. Methods: 43 patients, submitted to successful implantation of CRT, were evaluated in hospital just before intervention and in the outpatient clinic within 6 months after CRT. HRQL was analyzed based on the Kansas City Cardiomyopathy Questionnaire (KCCQ). Patients were classified as super-responders (ejection fraction of left ventricle - LVEF - ≥45% post-CRT), n=15, responders (sustained improvement in functional class and LVEF increased by 15%), n=19, and non-responders (no clinical or LVEF improvement), n=9. Results: In the group of super-responders, CRT was associated with an improvement in HRQL for the various fields and sums assessed (ρ<0.05); in responders, CRT has been associated with an improvement of HRQL in the various fields and sums, except in the self-efficacy dimension (ρ<0.05); in non-responders, CRT was not associated with improvement of HRQL. Conclusion: In a population with severe CHF undergoing CRT, the patients with clinical and echocardiographic positive response, obtained a favorable impact in all dimensions of HRQL, while the group without response to CRT showed no improvement. These data reinforces the importance of HRQL as a multidimensional tool for assessment of benefits in clinical practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho tem como objectivo apresentar as ferramentas do Lean Thinking e realizar um estudo de caso numa organização em que este sistema é utilizado. Numa primeira fase do trabalho será feito uma análise bibliográfica sobre o ―Lean Thinking”, que consiste num sistema de negócios, uma forma de especificar valor e delinear a melhor sequência de acções que criam valor. Em seguida, será realizado um estudo de caso numa Empresa – Divisão de Motores – no ramo da aeronáutica com uma longa e conceituada tradição com o objectivo de reduzir o TAT (turnaround time – tempo de resposta), ou seja, o tempo desde a entrada de um motor na divisão até à entrega ao cliente. Primeiramente, analisando as falhas existentes em todo o processo do motor, isto é, a análise de tempos de reparação de peças à desmontagem do motor que têm que estar disponíveis à montagem do mesmo, peças que são requisitadas a outros departamentos da Empresa e as mesmas não estão disponíveis quando são precisas passando pelo layout da divisão. Por fim, fazer uma análise dos resultados até então alcançados na divisão de Motores e aplicar as ferramentas do ―Lean Thinking‖ com o objectivo da implementação. É importante referir que a implementação bem-sucedida requer, em primeiro lugar e acima de tudo, um firme compromisso da administração com uma completa adesão à cultura da procura e eliminação de desperdício. Para concluir o trabalho, destaca-se a importância deste sistema e quais são as melhorias que se podem conseguir com a sua implantação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Intervenção Sócio-Organizacional na Saúde - Área de especialização: Políticas de Administração e Gestão de Serviços de Saúde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Tecnologia de Diagnóstico e Intervenção Cardiovascular. Área de especialização: Intervenção Cardiovascular.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thin films of TiO2 were doped with Au by ion implantation and in situ during the deposition. The films were grown by reactive magnetron sputtering and deposited in silicon and glass substrates at a temperature around 150 degrees C. The undoped films were implanted with Au fiuences in the range of 5 x 10(15) Au/cm(2)-1 x 10(17) Au/cm(2) with a energy of 150 keV. At a fluence of 5 x 10(16) Au/cm(2) the formation of Au nanoclusters in the films is observed during the implantation at room temperature. The clustering process starts to occur during the implantation where XRD estimates the presence of 3-5 nm precipitates. After annealing in a reducing atmosphere, the small precipitates coalesce into larger ones following an Ostwald ripening mechanism. In situ XRD studies reveal that Au atoms start to coalesce at 350 degrees C, reaching the precipitates dimensions larger than 40 nm at 600 degrees C. Annealing above 700 degrees C promotes drastic changes in the Au profile of in situ doped films with the formation of two Au rich regions at the interface and surface respectively. The optical properties reveal the presence of a broad band centered at 550 nm related to the plasmon resonance of gold particles visible in AFM maps. (C) 2011 Elsevier B.V. All rights reserved.