An in vitro study of non-axial forces upon the retention of an O-ring attachment


Autoria(s): RODRIGUES, Renata Cristina Silveira; FARIA, Adriana Claudia Lapria; MACEDO, Ana Paula; SARTORI, Ivete Aparecida de Mattias; MATTOS, Maria da Gloria Chiarello de; RIBEIRO, Ricardo Faria
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

19/10/2012

19/10/2012

2009

Resumo

Objective The purpose of this study was to evaluate the retention force of an O-ring attachment system in different inclinations to the ideal path of insertion, using devices to compensate angulations. Material and methods Two implants were inserted into an aluminum base, and ball attachments were screwed to implants. Cylinders with O-rings were placed on ball attachments and connected to the test device using positioners to compensate implant angulations (0 degrees, 7 degrees, and 14 degrees). Plexiglass bases were used to simulate implant angulations. The base and the test device were positioned in a testing apparatus, which simulated insertion/removal of an overdenture. A total of 2900 cycles, simulating 2 years of overdenture use, were performed and 36 O-rings were tested. The force required for each cycle was recorded with computer software. Longitudinal sections of ball attachment-positioner-cylinder with O-rings of each angulation were obtained to analyze the relationship among them, and O-ring sections tested in each angulation were compared with an unused counterpart. A mixed linear model was used to analyze the data, and the comparison was performed by orthogonal contrasts (alpha=0.05). Results At 0 degrees, the retention force decreased significantly over time, and the retention force was significantly different in all comparisons, except from 12 to 18 months. When the implants were positioned at 7 degrees, the retention force was statistically different at 0 and 24 months. At 14 degrees, significant differences were found from 6 and 12 to 24 months. Conclusions Within the limitations of this study, it was concluded that O-rings for implant/attachments perpendicular to the occlusal plane were adequately retentive over the first year and that the retentive capacity of O-ring was affected by implant inclinations despite the proposed positioners. To cite this article:Rodrigues RCS, Faria ACL, Macedo AP, Sartori IAM, de Mattos MGC, Ribeiro RF. An in vitro study of non-axial forces upon the retention of an O-ring attachment.Clin. Oral Impl. Res. 20, 2009; 1314-1319.doi: 10.1111/j.1600-0501.2009.01742.x.

Identificador

CLINICAL ORAL IMPLANTS RESEARCH, v.20, n.12, p.1314-1319, 2009

0905-7161

http://producao.usp.br/handle/BDPI/26363

10.1111/j.1600-0501.2009.01742.x

http://dx.doi.org/10.1111/j.1600-0501.2009.01742.x

Idioma(s)

eng

Publicador

WILEY-BLACKWELL PUBLISHING, INC

Relação

Clinical Oral Implants Research

Direitos

restrictedAccess

Copyright WILEY-BLACKWELL PUBLISHING, INC

Palavras-Chave #dental implantation #dental prosthesis retention #denture precision attachment #OVERDENTURE ATTACHMENTS #MANDIBULAR OVERDENTURE #PATIENT SATISFACTION #CLINICAL-TRIAL #IMPLANTS #SYSTEMS #Dentistry, Oral Surgery & Medicine #Engineering, Biomedical
Tipo

article

original article

publishedVersion