1000 resultados para Alkalinity, potentiometric


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(FF)(2)vertical bar Graphite, where FF stands for flufenamate ion, are described. This electrode responds to FF with sensitivity of (-58.6 +/- 1.2) mV decade(-1) over the range 1.0 x 10(-6) - 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 7.1 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 5 months without any considerable change in its performance characteristics. The proposed electrode displayed good selectivity for flufenamate in the presence of several substances as well as in the presence of some carboxylate and inorganic anions. The electrode was successfully applied to the determination of flufenamic acid in pharmaceuticals and human serum samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of adsorptive stripping potentiometry to the reductive detection of nucleic acids at mercury electrodes is reported. Compared to analogous voltammetric stripping modes, constant current potentiometric stripping analysis (PSA) effectively addresses the hydrogen discharge background problem, and hence greatly improves the characteristics of the superimposed cytosine/adenine (CA) reduction peak. Compared to earlier schemes for trace measurements of nucleic acids at mercury or carbon electrodes that rely on anodic signals arising from the guanine residue, convenient quantitation can now be carried out in connection with the cytosine and adenine residues. Variables influencing the adsorptive PSA response are explored and optimized. With five minute accumulation, the detection limits for tRNA, ssDNA and dsDNA are 30 mu g l(-1), 60 mu g l(-1) and 2 mg l(-1), respectively. Such different values reflect the strong dependence of the PSA CA signal upon the nucleic-acid structure. This allows the quantitation of ssDNA or tRNA in the presence of dsDNA, and offers new possibilities for electrochemical studies of DNA structure and interactions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely, Pt vertical bar Hg vertical bar Hg-2(IBP)(2)vertical bar Graphite, where IBP stands for ibuprofenate ion, are described. This electrode responds to IBP with sensitivity of (58.6 +/- 0.9) mV decade 1 over the range 5.0 x 10(-5)-1.0 x 10(-1) mol L-1 at pH 6.0-9.0 and a detection limit of 3.8 x 10(-5) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 1530 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for ibuprofen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of ibuprofen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. (c) 2006 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely. Pt\Hg\Hg-2(Bzt)(2)\graphite, where Bzt stands for benzoate ion. are described. This electrode responds to Bzt with sensitivity of 57.7 +/- 1.0 mV/decade over the range 5 x 10(-4)-1 x 10(-1) mol l(-1) at pH 6.0-8.0 with a detection limit of 1.6 x 10(-4) mol l(-1). The electrode shows easy construction, fast response rime (between 10-30 s), low-cost, acid excellent response stability (lifetime > 6 months, in continuous use), the proposed sensor displayed good selectivity for benzoate in the presence of several carboxylate and inorganic anions. It was used to determine benzoate in various beverages by means of the standard additions method. The results obtained by using this electrode compared very favorably with those given by the official AOAC spectrophotometric method and by a HPLC procedure as well. (C) 2001 Elsevier B.V. B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely, Pt\Hg\Hg-2(PABzt)(2)\ graphite, where PABzt stands for p-aminobenzoate ion, are described. This electrode responds to PABzt with sensivity of (58.1 +/- 1.0) mV per decade over the range 1.0 x 10(-4) to 1.0 x 10(-1) mol l(-1) at pH 6.5-8.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode shows easy construction, fast response time (within 10-30 s), low-cost, and excellent response stability (lifetime greater than 6 months, in continuous use). The proposed sensor displayed good selectivity for p-aminobenzoate in the presence of several substances, especially, concerning carboxylate and inorganic anions. It was used to determine p-aminobenzoate in pharmaceutical formulations by means of the standard additions method. The results obtained by using this electrode compared very favorably with those given by an HPLC procedure. (C) 2004 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of a novel and simple electrode, namely Pt vertical bar Hg vertical bar Hg-2(MF)(2)vertical bar Graphite, where MF stands for mefenamate ion, are described. This electrode responds to MF with sensitivity of (58.9 +/- 0.7) mV decade(-1) over the range 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 6.2 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 4 months without significant change in its performance characteristics. The proposed sensor displayed good selectivity for mefenamate in the presence of several substances, especially concerning carboxylate and inorganic anions. The potentiometric sensor was successfully applied to the determination of mefenamic acid in pharmaceuticals and human serum samples. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely Pt| Hg|Hg-2(DCF)(2)|graphite, where DCF stands for diclofenac ion, are described. This electrode responds to diclofenac with sensitivity of (58.1 +/- 0.8) mV/decade over the range 5.0 x 10(-5) to 1.0 x 10(-2) Mol l(-1) at pH 6.5-9.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode is easily constructed at a relatively low cost with fast response time (within 10-30 s) and can be used for a period of 5 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for diclofenac in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used to determine diclofenac in pharmaceutical preparations by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedures. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A highly sensitive adsorptive stripping procedure for trace measurement of the anticancer drug tamoxifen is described. The method is based on controlled adsorptive accumulation of the drug at an electrochemically treated glassy carbon electrode, followed by chronopotentiometric measurement of the surface species. The chronopotentiometric operation effectively addresses the large background contribution inherent to the glassy carbon electrode to yield a detection limit of 4 x 10(-10) M after 4 min preconcentration. The adsorptive stripping response is evaluated with respect to electrode type and conditioning, accumulation potential and lime, stripping current, pH, drug concentration, potential interferences, and other variables. Applicability to urine samples is illustrated. (C) 1997 Elsevier B.V. B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, rapid and low-cost potentiometric method for saccharin determination in commercial artificial sweeteners is proposed. Saccharin present in several samples of artificial sweeteners is potentiometrically titrated with silver nitrate solution using a silver wire as the indicator electrode, coupled to a titroprocessor. The best pH range was from 3.0 to 3.5 and the detection limit of sodium saccharin was 2.5 mg/ml. Substances normally found along with saccharin in several commercial artificial sweeteners such as maltodextrin, glucose, sucrose, fructose, aspartame, cyclamate, caffeine, sorbitol, lactose, nitrate, methyl- and n-propyl-p-hydroxybenzoate, benzoic, citric and ascorbic acids do not interfere even in significant amounts (e.g. 20 excess relative to saccharin). Chloride ion interferes when present in concentrations larger than 10 mg l(-1); this interference is eliminated with previous extraction of the sweetener from the aqueous medium with ethyl acetate. The results obtained by applying the proposed method compared very favorably with those given by the HPLC method recommended by the FDA. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple, precise, fast and low-cost potentiometric method for alendronate determination in pharmaceutical formulations has been proposed. Alendronate present in tablets at the known concentration was potentiometrically titrated in an aqueous solution using a combined glass electrode coupled with an autotitrator. Determination limit of alendronate was 20.0 mug mL(-1). In the presence of common excipients, such as lactose, microcrystalline cellulose, glucose, croscarmellose sodium, starch, talc, magnesium stearate and titanium dioxide no interferences were observed. The method proposed was validated by determining alendronate in various dosage forms. The average RSD was 0.75%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A potentiometric sensor for the perchlorate anion was developed by mixing chemically modified silicagel with pyridinium perchlorate, with an epoxy polymer and graphite. The electrode showed Nernstian response between 1.0 × 10-2 and 1.0 × 10-3M perchlorate concentrations. The electrode showed high selectivity to this ion at solutions pH between 5.5 and 8.0. The presence of IO4 -, NO3 -,Br-, IO3 -, Cl- and SO4 2- ions in the solutions, had only small interference in the electrode response in the range mentioned. © 1995 Springer-Verlag.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristics, performance, and application of an electrode, namely, Pt|Hg|Hg 2(NAP) 2| Graphite, where NAP stands for naproxenate ion, are described. This electrode responds to NAP with sensivity of (58.1± 0.9) mV decade -1 over the range 5.0 × 10 -5 - 1.0 × 10 -2 mol L -1 at pH 6.0-9.0 and a detection limit of 3.9 × 10 -5 mol L -1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-35 s) and can be used for a period of 6 months without any considerable divergence in potentials. The proposed sensor displayed good selectivity for naproxen in the presence of several substances, especially concerning carboxylate and inorganic anions. It was used for the direct assay of naproxen in commercial tablets by means of the standard additions method. The analytical results obtained by using this electrode are in good agreement with those given by the United States Pharmacopeia procedure. ©2006 Sociedade Brasileira de Química.