p-Aminobenzoate ion determination in pharmaceutical formulations by using a potentiometric sensor immobilized in a graphite matrix
Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
---|---|
Data(s) |
20/05/2014
20/05/2014
08/07/2004
|
Resumo |
The characteristics, performance, and application of an electrode, namely, Pt\Hg\Hg-2(PABzt)(2)\ graphite, where PABzt stands for p-aminobenzoate ion, are described. This electrode responds to PABzt with sensivity of (58.1 +/- 1.0) mV per decade over the range 1.0 x 10(-4) to 1.0 x 10(-1) mol l(-1) at pH 6.5-8.0 and a detection limit of 3.2 x 10(-5) mol l(-1). The electrode shows easy construction, fast response time (within 10-30 s), low-cost, and excellent response stability (lifetime greater than 6 months, in continuous use). The proposed sensor displayed good selectivity for p-aminobenzoate in the presence of several substances, especially, concerning carboxylate and inorganic anions. It was used to determine p-aminobenzoate in pharmaceutical formulations by means of the standard additions method. The results obtained by using this electrode compared very favorably with those given by an HPLC procedure. (C) 2004 Elsevier B.V. All rights reserved. |
Formato |
833-838 |
Identificador |
http://dx.doi.org/10.1016/j.talanta.2003.12.039 Talanta. Amsterdam: Elsevier B.V., v. 63, n. 4, p. 833-838, 2004. 0039-9140 http://hdl.handle.net/11449/32684 10.1016/j.talanta.2003.12.039 WOS:000222063600004 |
Idioma(s) |
eng |
Publicador |
Elsevier B.V. |
Relação |
Talanta |
Direitos |
closedAccess |
Palavras-Chave | #p-aminobenzoate-sensitive electrode #potentiometry #pharmaceutical formulations |
Tipo |
info:eu-repo/semantics/article |