Development of a potentiometric mefenamate ion sensor for the determination of mefenamic acid in pharmaceuticals and human blood serum


Autoria(s): Santini, A. O.; Pezza, Helena Redigolo; Pezza, Leonardo
Contribuinte(s)

Universidade Estadual Paulista (UNESP)

Data(s)

20/05/2014

20/05/2014

12/12/2007

Resumo

The characteristics, performance, and application of a novel and simple electrode, namely Pt vertical bar Hg vertical bar Hg-2(MF)(2)vertical bar Graphite, where MF stands for mefenamate ion, are described. This electrode responds to MF with sensitivity of (58.9 +/- 0.7) mV decade(-1) over the range 1.0 x 10(-6) to 1.0 x 10(-2) mol L-1 at pH 6.0-9.0 and a detection limit of 6.2 x 10(-7) mol L-1. The electrode is easily constructed at a relatively low cost with fast response time (within 10-25 s) and can be used for a period of 4 months without significant change in its performance characteristics. The proposed sensor displayed good selectivity for mefenamate in the presence of several substances, especially concerning carboxylate and inorganic anions. The potentiometric sensor was successfully applied to the determination of mefenamic acid in pharmaceuticals and human serum samples. (c) 2007 Elsevier B.V. All rights reserved.

Formato

117-123

Identificador

http://dx.doi.org/10.1016/j.snb.2007.05.039

Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 128, n. 1, p. 117-123, 2007.

0925-4005

http://hdl.handle.net/11449/34286

10.1016/j.snb.2007.05.039

WOS:000251465000016

Idioma(s)

eng

Publicador

Elsevier B.V.

Relação

Sensors and Actuators B: Chemical

Direitos

closedAccess

Palavras-Chave #mefenamate-sensitive electrode #potentiometry #pharmaceuticals #human blood serum
Tipo

info:eu-repo/semantics/article