Potentiometric study using chemically modified silica gel with pyridinium as membrane for ClO4 - ions
| Contribuinte(s) |
Universidade Estadual Paulista (UNESP) |
|---|---|
| Data(s) |
27/05/2014
27/05/2014
01/09/1995
|
| Resumo |
A potentiometric sensor for the perchlorate anion was developed by mixing chemically modified silicagel with pyridinium perchlorate, with an epoxy polymer and graphite. The electrode showed Nernstian response between 1.0 × 10-2 and 1.0 × 10-3M perchlorate concentrations. The electrode showed high selectivity to this ion at solutions pH between 5.5 and 8.0. The presence of IO4 -, NO3 -,Br-, IO3 -, Cl- and SO4 2- ions in the solutions, had only small interference in the electrode response in the range mentioned. © 1995 Springer-Verlag. |
| Formato |
239-244 |
| Identificador |
http://dx.doi.org/10.1007/BF01244893 Mikrochimica Acta, v. 117, n. 3-4, p. 239-244, 1995. 0026-3672 1436-5073 http://hdl.handle.net/11449/64632 10.1007/BF01244893 2-s2.0-0003095863 |
| Idioma(s) |
eng |
| Relação |
Mikrochimica Acta |
| Direitos |
closedAccess |
| Palavras-Chave | #modified silica gel #perchlorate analysis #perchlorate selective electrode #pyridinium ion |
| Tipo |
info:eu-repo/semantics/article |