865 resultados para Dispositivi medici


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Root resorption can cause damage in orthodontic patients. Digital subtraction radiography (DSR) is a useful resource for the detection of mineral losses. The purpose of this study was to compare the efficacy of digital radiography (DR) and DSR in detecting simulated external root resorption. Examiner agreement between the 2 techniques was also evaluated. Methods: Root resorptions of various sizes were simulated on the apical and lingual aspects of 49 teeth from 9 dry human mandibles. The teeth were radiographed in standardized conditions. The radiographs were registered with Regeemy Image Registration and Mosaicking (version 0.2.43-RCB, DPI-INPE, Sao Jose dos Campos, São Paulo, Brazil) and subtracted with Image Tool (University of Texas Health Science Center at San Antonio). The subtracted images and the digital radiographs were evaluated by 3 oral radiologists. Results: No statistically significant differences were found for the methods in the detection of apical root resorptions, independently from lesion size, and of lingual resorptions of 1.2 mm or greater. DSR was significantly better than DR for detection of lingual resorptions up to 1 mm. Resorptions less than 0.5 mm were not precisely detected by either method. DSR provided better intraexaminer and interexaminer agreement than did DR. Conclusions: Both methods are precise for detection of apical root resorptions as small as 0.5 mm and lingual resorptions of 1 mm or more. However, DSR frequently performed better than did DR. (Am J Orthod Dentofacial Orthop 2011;139:324-33)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os propósitos deste trabalho foram: avaliar o desenvolvimento do fruto do mamoeiro (Carica papaya L.), determinar as variações das concentrações dos nutrientes durante seu crescimento e calcular as quantidades de nutrientes exportados pela colheita dos frutos. Dentre os resultados obtidos constatou-se que, as quantidades de nutrientes exportadas através da colheita, por tonelada de frutos foram: N-1.770g- P - 220 g; K-2.120 g; Ca-350 g; Mg - 180 g; S-200g: B-989 mg; Cu-130 mg; Fe-3.364 mg; Mn -1.847 mg; Mo-8 mg e Zn-1.385 mg.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The study of the Divine Proportion (Φ = 1.618) began with the Greeks, having as main researchers the mathematician Pythagoras and the sculptor Phidias. In Dentistry, Ricketts (1981-82) was an early to study this issue. OBJECTIVE: This study proposed to evaluate how some cephalometric measures are presented in relation to the Divine Proportion, with the total of 52 proportions, formed by 28 cephalometric landmarks. METHODS: Lateral cephalograms of 40 Class II adults patients aging from 17 to 45 years (13 male and 27 female) were evaluated. The linear distances between the landmarks were measured using Radiocef Studio software. RESULTS: After statistical analysis, the data shown an average of 65,48% in the Divine Proportion, 17,5% in the relation Ans-Op/V1S-DM16 and 97,5% in the relations Na-Me/Na-PoNa e Na-PoNa/Na-Gn. CONCLUSION: Among all cephalometric measurements investigated, the lower facial third and the dental arches showed the smallest percentages of Divine Proportion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar a influência do cetoprofeno sobre o processo de reparação óssea em tíbias de ratos, por meio da análise da densidade óptica digital. Vinte ratos da linhagem Wistar foram divididos em 2 grupos: um grupo controle (sem tratamento) e um grupo tratado com cetoprofeno. Os procedimentos experimentais consistiram de: anestesia, cirurgia, administração do cetoprofeno e exame radiográfico. As imagens radiográficas foram adquiridas empregando-se o sensor digital Visualix GX-S-HDI™ e um aparelho de raios X. As radiografias foram realizadas nos períodos baseline (inicial), 7, 14, 21 e 30 dias pós-operatório, sendo a densidade óptica (DO) avaliada por meio do sistema Vix winTM 1.4. Os valores médios da leitura da do obtidos foram analisados estatisticamente por meio de ANOVA e teste de Tukey com nível de significância de 5%. No grupo controle, houve diferença estatisticamente significante (p=0,001) entre o tempo e a DO, enquanto no grupo tratado com cetoprofeno a diferença não foi estatisticamente significante (p=0,100). O grupo controle apresentou as menores proporções de do (%) no 1º e 7º dias e as maiores proporções de do (%) no 14º, 21º e 30º dias, com diferença estatisticamente significante (p=0,001). Não houve diferença estatisticamente significante (p=0,100) entre as proporções médias de do (%) no grupo tratado, independentemente do período de avaliação. Os achados deste trabalho sugerem que houve influência do cetoprofeno sobre o processo de reparo ósseo, uma vez que na primeira semana o medicamento proporcionou aumento na densidade óptica e provocou atraso na neoformação óssea após o 21º dia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the accuracy of approximal caries detection comparing enhanced and unenhanced Sidexis CCD-based digital image with Ektaspeed Plus and INSIGHT films. Methods: Fifty-two extracted premolars were imaged under identical standardized geometric and exposure conditions. Four observers, using five points confidence scale, rated 104 approximal surfaces for the presence or absence of carious lesions by means of four image modalities: (1) observer enhanced; (2) unenhanced Sidexis displays; (3) E speed films and (4) F speed film. Histologic sections served as validating criterion for the presence and depth of carious lesions. Diagnostic accuracy was measured as the area beneath the ROC curve. Results: Mean ROC (receiver operating characteristic) curve areas for approximal surfaces were 0.865 (E speed), 0.856 (F speed), 0.816 (unenhanced Sidexis) and 0.776 (observer enhanced). There were no significant differences between unenhanced digital Sidexis and films. Observer enhanced Sidexis images exhibited a statistically significant lower diagnostic accuracy than the film images for two of the observers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper analyses the dew occurrence in Botucatu, Sao Paulo State, Brazil, in the period from 1971 to 1984. The phenomenon was observed on the grass plot of the Climatological Station in the 'Presidente Medici' Experimental Farm. The station is installed on soil 'Terra Roxa Estruturada', on a middle slope, declivity of 8% and east exposure. Days with dew were summed for the following periods: month, year, season, no rainy period and rainy period. For each period the following values were calculated: mean, mean standard errors and mean confidence interval. Also the absolute extreme values and the amplitude of variation were determined. The confidence interval of the mean were calculated by the 't' statistic, at the level of 5% of error probability. The means were compared by using the 't' statistic, at the level of 5% of error probability. The following table of values corresponds to the regime of dew occurrence in Botucatu, expressed in number of days with dew. The dew occurrence regime in Botucatu was analysed comparatively with the regime at Itatinga, in Sao Paulo State and with the regime of Rio Grande, in Rio Grande do Sul State. -English summary

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In a sample of Brazilian white young adults between 18-23 years old, the A.A. studied the third molar roots, in anatomical aspects, using the orthopantomographic radiographic method. They concluded that the superior third molar shows a biggest number of fusionated roots (19.50% in the right side and 19.66% in the left side) and the inferior third molar shows a biggest number of separated roots (21.48% in the right side and 19.66% in the left side).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this article was to compare the mean value of optical density of four porcelains commonly used for fabrication of inlay/ onlay prostheses using direct digital radiograph. The sample consisted of 20 2-mm thick porcelain specimens (measured by digital pachymeter): Empress (Ivoclair), Simbios (Degussa), Vita Omega 900 and Vitadur Alpha (Vita Zahnfabrik). The values of optical density of the specimens were expressed in millimeters aluminum equivalent (mm eq Al). The samples were X-rayed using two charge coupled devices (CCD) - RVG (Trophy) - Visualix (Gendex) and a phosphor plate system - Digora (Soredex). The optical density reading was performed with Image Tool 1.28 in a total of 110 measurements. Statistical analysis showed that there were statistically significant differences in all materials studied (p < 0.05) regardless of the radiographic system used. The highest optical density value was found for Omega 900 (1.8988 mmeqAl - Visualix - Gendex) and the lowest for Vitadur Alpha (0.8647 - Visualix - Gendex). Thus, the material presenting the highest degree of optical density was Omega 900, Empress and Simbios presented intermediate optical density values, Vitadur Alpha presented the lowest value, and the optical density of porcelains was not influenced by the digital radiography systems.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The reproducibility of measurements of alveolar bone loss on radiographs may be a problem on epidemiologic studies, as they are based on comparisons of the diagnosis of various examiners. The aim of the present research paper was to assess the inter- and intra-examiner reproducibility of measurements of the interproximal alveolar bone loss on non-manipulated digital radiographs and after the application of image filters. Five Oral Radiologists measured the distance between the cementoenamel junction (CEJ) to the alveolar crest or to the deepest point of the bony defect on 12 interproximal digital radiographs of molars and bicuspids of a dry human skull. The digital manipulation and the linear measurements were obtained with the Trophy Windows software (Throphy®). For each image, six different versions were created: 1) non-manipulated; 2) bright-contrast adjustment; 3) negative; 4) negative with brightness-contrast adjustment; 5) pseudo-colored; 6) pseudo-colored with brightness-contrast adjustment. In order to prevent interpretation bias because of the repetition of measurements, the examiners measured the radiographs in a random sequence. The two-way ANOVA test at 5% level of significance to compare the means of readings of the same operator with each filter indicated p<0.05 for the majority of operators, while the comparison between the mean values of operators using the same filter indicated p>0.05 for all filters. Based on the results, we concluded that linear measurements of interproximal alveolar bone loss on digital radiographs are highly reproducible among examiners. Nevertheless, the application of image filters significantly influenced the degree of intra-examiner reproducibility. Some filters even reduced the reproducibility of intra-examiner readings.