15 resultados para UKLTRASHORT PULSES

em ArchiMeD - Elektronische Publikationen der Universität Mainz - Alemanha


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis is focused on the development of heteronuclear correlation methods in solid-state NMR spectroscopy, where the spatial dependence of the dipolar coupling is exploited to obtain structural and dynamical information in solids. Quantitative results on dipolar coupling constants are extracted by means of spinning sideband analysis in the indirect dimension of the two-dimensional experiments. The principles of sideband analysis were established and are currently widely used in the group of Prof. Spiess for the special case of homonuclear 1H double-quantum spectroscopy. The generalization of these principles to the heteronuclear case is presented, with special emphasis on naturally abundant 13C-1H systems. For proton spectroscopy in the solid state, line-narrowing is of particular importance, and is here achieved by very-fast sample rotation at the magic angle (MAS), with frequencies up to 35 kHz. Therefore, the heteronuclear dipolar couplings are suppressed and have to be recoupled in order to achieve an efficient excitation of the observed multiple-quantum modes. Heteronuclear recoupling is most straightforwardly accomplished by performing the known REDOR experiment, where pi-pulses are applied every half rotor period. This experiment was modified by the insertion of an additional spectroscopic dimension, such that heteronuclear multiple-quantum experiments can be carried out, which, as shown experimentally and theoretically, closely resemble homonuclear double-quantum experiments. Variants are presented which are well-suited for the recording of high-resolution 13C-1H shift correlation and spinning-sideband spectra, by means of which spatial proximities and quantitative dipolar coupling constants, respectively, of heteronuclear spin pairs can be determined. Spectral editing of 13C spectra is shown to be feasible with these techniques. Moreover, order phenomena and dynamics in columnar mesophases with 13C in natural abundance were investigated. Two further modifications of the REDOR concept allow the correlation of 13C with quadrupolar nuclei, such as 2H. The spectroscopic handling of these nuclei is challenging in that they cover large frequency ranges, and with the new experiments it is shown how the excitation problem can be tackled or circumvented altogether, respectively. As an example, one of the techniques is used for the identification of a yet unknown motional process of the H-bonded protons in the crystalline parts of poly(vinyl alcohol).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die vorliegende Arbeit beschäftigt sich vorwiegend mit Detektionsproblemen, die bei Experimenten zur Chemie der Transactiniden mit dem schnellen Flüssig-Flüssig-Extraktionssystem SISAK auftraten. Bei diesen Experimenten wird als Detektionsmethode die Flüssigszintillationsspektroskopie (LSC) eingesetzt. Es werden Szintillationspulse registriert, die für das verursachende Teilchen charakteristische Formen zeigen, die unterschieden werden müssen. Am Beispiel der Auswertung des SISAK-Experimentes zur Chemie des Rutherfordiums vom November 1998 wurde gezeigt, dass es mit den herkömmlichen Verfahren zur Pulsformdiskriminierung nicht möglich ist, die aus dem Zerfall der Transactiniden stammenden alpha-Ereignisse herauszufiltern. Ursache dafür ist ein hoher Untergrund, der in erster Linie von beta/gamma-Teilchen, Spaltfragmenten und pile ups verursacht wird. Durch die Verfügbarkeit von Transientenrecordern ergeben sich neue Möglichkeiten für eine digitale Pulsformdiskriminierung. In dieser Arbeit wird erstmals die Methode der digitalen Pulsformdiskriminierung mit künstlichen neuronalen Netzen (PSD-NN) vorgestellt. Es wurde im Zuge der Auswertung des SISAK-Experimentes vom Februar 2000 gezeigt, dass neuronale Netze in der Lage sind, Pulsformen automatisch richtig zu klassifizieren. Es ergeben sich nahezu untergrundfreie alpha-Flüssigszintillationsspektren. Es werden Vor- und Nachteile der neuen Methode diskutiert. Es ist dadurch möglich geworden, in SISAK-Experimenten Transactinidenatome anhand ihres Zerfalls eindeutig zu charakterisieren. Das SISAK-System kann somit bei Experimenten zum Studium des chemischen Verhaltens von Transactiniden in flüssiger Phase eingesetzt werden.____

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Gegenstand dieser Arbeit ist die Untersuchung von Photokathoden mit negativer Elektronenaffinität (NEA) mittels zeitlich hochauflösender Vermessung der emittierten Ladungs- und Spinpolarisationsverteilungen nach Anregung mit einem ultrakurzen Laserpuls. Untersucht wurden uniaxial deformierte GaAsP-Photokathoden mit dünnen emittierenden Schichten (≤150nm), sowie undeformierte GaAs-Photokathoden mit unterschiedlichen Schichtdicken. Die Untersuchungen wurden an einer 100keV-Elektronenquelle durchgeführt, wie sie am Mainzer Mikrotron (MAMI) zur Erzeugung eines Spinpolarisierten Elektronenstrahls verwendet wird. Mit der Apparatur konnte eine Zeitauflösung von 2,5ps erreicht werden. Es zeigte sich, dass die tatsächliche Antwortzeit der Photokathoden die erreichte Zeitauflösung noch unterschreitet. Eine Depolarisation in den kurzen, wegen der Zeitauflösung auf 2,5ps begrenzten, Elektronenpulsen konnte aber nachgewiesen werden. Weiterhin wurde gezeigt, dass der Polarisationsverlust der emittierten Elektronen bei dünnen Schichten im Wesentlichen auf eine energiekorrelierte Depolarisation beim Durchqueren der Bandbiegungszone zurückzuführen ist. Als weiteres Resultat wird, für die GaAsP-Photokathoden mit einer Schichtdicke von 150nm, eine Obergrenze für die mittlere Emissionszeit von ≤1,25ps angegeben. Daraus ergibt sich nach dem hier verwendeten Diffusionsmodell eine Untergrenze für die Oberflächenrekombinationsgeschwindigkeit an der Bandbiegungszone von S≥1,2·10^7 cm/s.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die freien Endigungen von Spinalganglienneuronen sind für die Detektion schmerzhafter Reize verantwortlich. Dabei rufen thermische, chemische oder mechanische Reize Ionenströme über die Membran und dadurch Membranpotentialänderungen hervor. Diese noxisch induzierten Ströme sind in großem Ausmaß durch chemische Substanzen und andere Reize modulierbar. Der Ionenkanal TRPV1 ist für die Detektion zahlreicher chemischer Reize und zumindest eines Teils der noxischen Hitzereize verantwortlich. Im Rahmen dieser Arbeit wurden einige der Mechanismen geklärt, die zur schnellen Sensibilisierung hitzeevozierter Ionenströme führen. Hierfür wurden akut dissoziierte Spinalganglienneurone der Ratte als Modell ihrer peripheren Endigung verwendet und mittels Ganzzellableitung in der patch-clamp-Technik untersucht. Die Verwendung von Trypsin während der Präparation von Spinalganglienneuronen hat keinen funktionellen Einfluss auf hitze- oder capsaicininduzierte Ströme, verbessert aber die Untersuchungsbedingungen für das patch-clamp-Verfahren. Bei 144 akut dissoziierten Spinalganglienneuronen wurden die Stromantworten auf drei im Abstand von 40 s durch Überspülen mit 45,3 bis 46,3°C heißer Extrazellularlösung applizierte einsekündige Hitzereize gemessen. Dabei ließen sich repetitiv reproduzierbare hitzeinduzierte Einwärtsströme von etwa 160 pA erzielen; es konnte keine Tachyphylaxie und nahezu keine Inaktivierung beobachtet werden. Direkt vor dem zweiten Hitzereiz wurden die Neurone für zwei Sekunden mit Extrazellularlösung überspült, die Kontrolllösung, 0,5 μM Capsaicin, 10 μM Natriumnitroprussid oder 10 μM YC-1 enthielt. Es fand sich kein Hinweis, dass Stickstoffmonoxid oder die Guanylatzyklase einen signifikanten Beitrag zur Sensibilisierung von hitzeinduzierten Strömen in Spinalganglienneuronen leisten, wobei ein durch den Versuchsaufbau bedingtes Auswaschen zytosolischer Faktoren, die für den Signalweg notwendig sind, nicht ausgeschlossen werden kann. Bei einer Konzentration von 0,5 μM löst Capsaicin für zwei Sekunden einen sehr kleinen Einwärtsstrom von etwa 33 pA aus und führt innerhalb von zwei Sekunden zu einer schnell reversiblen Sensibilisierung von hitzeinduzierten Einwärtsströmen in Spinalganglienneuronen (p<0,01). Das Ausmaß der Sensibilisierung ist proportional zur Größe des capsaicininduzierten Stromes (r=−0,7, p<0,001). Konstant halten der intrazellulären Calciumkonzentration mittels des Calciumchelators BAPTA verhindert die capsaicininduzierte Sensibilisierung hitzeinduzierter Ströme an Spinalganglienneuronen. Demzufolge beruht die capsaicininduzierte Sensibilisierung trotz der schnellen Kinetik nicht auf einer synergistischen Wirkung der beiden Agonisten Capsaicin und Hitze auf ihren gemeinsamen Rezeptor; vielmehr ist sie von einer Erhöhung der intrazellulären freien Calciumkonzentration abhängig. Funktionelle Änderungen der zellulären Funktion werden häufig durch Proteinkinasen vermittelt. Die zur Gruppe der MAP-Kinasen gehörende ERK (extracellular signal related kinase) wird bei Membrandepolarisation und Calciumeinstrom in die Zelle durch MEK (MAPK/extracellular signal related kinase kinase) aktiviert. Blockade der MEK/ERK-Kaskade durch den spezifischen MEK-Hemmstoff U0126 führt ebenfalls zu einer Aufhebung der Sensibilisierung der Hitzeantworten durch Capsaicin. Applikation von Capsaicin führt innerhalb von zwei Sekunden zu einer schnell reversiblen Sensibilisierung hitzeevozierter Ionenströme an nozizeptiven Spinalganglienneuronen. Diese Sensibilisierung wird durch einen Calciumeinstrom in die Zelle und die dadurch eintretende Aktivierung von Proteinkinasen hervorgerufen. Die MEK/ERK-Kaskade ist ein sehr schnell (deutlich unter 2 s) aktivierbares intrazelluläres Signalsystem, welches bei der Regulation der Empfindlichkeit nozizeptiver Spinalganglienneurone eine entscheidende Rolle spielt; die schnelle Kinetik ist dabei nur durch eine membranständige oder zumindest membrannahe Lokalisation dieser Proteinkinasen erklärbar. Durch Applikation zehnsekündiger Hitzereize lässt sich ebenfalls eine Sensibilisierung hitzeevozierter Ionenströme auslösen, die ebenso ausgeprägt ist, wie die Sensibilisierung durch 0,5 μM Capsaicin (p<0,005). Durch das immer größere Verständnis der Funktionsweise des nozizeptiven Systems ergeben sich ständig neue Ansätze für die Entwicklung neuer Analgetika. So könnte durch Modulation spezifischer intrazellulärer Proteinkinasen der Phosphorylierungszustand und damit die Aktivierbarkeit von Ionenkanälen, die der Transduktion noxischer Reize dienen, positiv beeinflusst werden. Neuere, noch spezifischere Inhibitoren der MEK können der Forschung und später auch der Therapie neue Möglichkeiten eröffnen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die diffusionsgewichtete Magnetresonanztomographie (MRT) mit dem hyperpolarisierten Edelgas-Isotop 3He ist ein neues Verfahren zur Untersuchung von Erkrankungen der Atem-wege und der Lunge. Die Diffusionsbewegung der 3He-Atome in den Luftwegen der Lunge wird durch deren Wände begrenzt, wobei diese Einschränkung sowohl von den Dimensionen der Atemwege als auch von den Messparametern abhängt. Man misst daher einen scheinbaren Diffusionskoeffizienten (Apparent Diffusion Coefficient, ADC) der kleiner ist als der Diffusionskoeffizient bei freier Diffusion. Der ADC gestattet somit eine qualitative Abschät-zung der Größe der Luftwege und deren krankhafte Veränderung, ohne eine direkte Abbil-dung der Luftwege selbst. Eine dreidimensionale Abbildung der räumlichen Verteilung von Lungenschädigungen wird dadurch möglich. Ziel der vorliegenden Arbeit war es, ein tieferes physikalisch fundiertes Verständnis der 3He-Diffusionsmessung zu ermöglichen und die Methode der diffusionsgewichteten 3He-MRT hin zur Erfassung des kompletten 3He-Diffusionstensors weiterzuentwickeln. Dazu wurde systematisch im Rahmen von Phantom- und tierexperimentellen Studien sowie Patientenmes-sungen untersucht, inwieweit unterschiedliche Einflussfaktoren das Ergebnis der ADC-Messung beeinflussen. So konnte beispielsweise nachgewiesen werden, dass residuale Luftströmungen am Ende der Einatmung keinen Einfluss auf den ADC-Wert haben. Durch Simulationsrechnungen konnte gezeigt werden, in welchem Maße sich die durch den Anregungspuls hervorgerufene Abnah-me der Polarisation des 3He-Gases auf den gemessenen ADC-Wert auswirkt. In einer Studie an lungengesunden Probanden und Patienten konnte die Wiederholbarkeit der ADC-Messung untersucht werden, aber auch der Einfluss von Gravitationseffekten. Diese Ergebnisse ermöglichen genauere Angaben über systematische und statistische Messfehler, sowie über Grenzwerte zwischen normalem und krankhaft verändertem Lungengewebe. Im Rahmen dieser Arbeit wurde die bestehende diffusionsgewichtete Bildgebung methodisch zur Erfassung des kompletten Diffusionstensors von 3He in der Lunge weiterentwickelt. Dies war wichtig, da entlang der Luftwege weitestgehend freie Diffusion vorherrscht, während senkrecht zu den Luftwegen die Diffusion eingeschränkt ist. Mit Hilfe von Simulationsrech-nungen wurde der kritische Einfluss von Rauschen in den MRT-Bildern auf die Qualität der Messergebnisse untersucht. Diese neue Methodik wurde zunächst an einem Phantom beste-hend aus einem Bündel aus Glaskapillaren, deren innerer Durchmesser mit dem des mensch-lichen Azinus übereinstimmt, validiert. Es ergab sich eine gute Übereinstimmung zwischen theoretischen Berechnungen und experimentellen Ergebnissen. In ersten Messungen am Menschen konnten so unterschiedliche Anisotropiewerte zwischen lungengesunden Proban-den und Patienten gefunden werden. Es zeigte sich eine Tendenz zu isotroper Diffusion bei Patienten mit einem Lungenemphysem. Zusammenfassend tragen die Ergebnisse der vorliegenden Arbeit zu einem besseren Ver-ständnis der ADC-Messmethode bei und helfen zukünftige Studien aufgrund des tieferen Verständnisses der die 3He Messung beeinflussenden Faktoren besser zu planen.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die vorliegende Dissertation beschreibt die Realisation des neuartigen Konzepts der Laserionenquellenfalle für die on-line Produktion exotischer Nuklide und für den Nachweis von Spurenisotopen in Proben mit starken Isobarenkontaminationen. Ziel dieser Entwicklung ist eine wesentliche Steigerung der Isobarenselektivität einer herkömmlichen Laserionenquelle, sowie die Erzeugung zeitlich kontrollierter Ionenpulse mit hervorragender Strahlqualität. Es konnte die prizipielle Funktionsfähigkeit des Systems in Kombination mit einem Titan:Saphir-Lasersystem für die Elemente Gallium, Calcium und Nickel demonstriert und Ionenpulse mit einer minimalen Pulslänge von 1 µs erzeugt werden. Nach ersten Abschätzungen ist die Effizienz des Systems etwa einen Faktor 2500 geringer als die einer herkömmlichen Laserionenquelle. Der zweite Teil der Arbeit beschäftigt sich mit dem spurenanalytischen Nachweis von 99-Tc, mit dem Ziel, das Verhalten von 99-Tc in der Umgebung eines möglichen Endlagers für nukleare Abfälle studieren zu können. Hier wurden erste Studien mit dem kurzlebigen Isomer 99m-Tc zur Wechselwirkung von Tc(VII) mit Huminsäure und Kaolinit durchgeführt. Für den Einsatz der Laserionenquellenfalle in der Ultraspurenanalyse, wurde ein effizientes Anregungsschema für Titan:Saphir-Laser entwickelt und 99-Tc in einer herkömmlichen Ionenquelle nachgewiesen. Der letzte Teil der Arbeit beschreibt Machbarkeitsstudien zum Aufbau einer Laserionenquelle auf Basis eines Titan:Sahphir-Lasersystems, die parallel zu oben genannten Entwicklungen am Oak Ridge National Laboratory durchgeführt wurden. Im Rahmen dieser Messungen wurden Anregungsschemata für die resonante Anregung und Ionisation von Kupfer und Palladium für Titan:Saphir-Laser getestet. Dabei konnte zum ersten Mal frequenzvervierfachtes Laserlicht in einer Laserionenquelle eingesetzt werden. Am ORNL wurden Studien zur Zeitstruktur von Laserionenpulsen, sowie Emittanzmessungen von Laser- und Oberflächenionenstrahlen durchgeführt werden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In dieser Arbeit wurde die Elektronenemission von Nanopartikeln auf Oberflächen mittels spektroskopischen Photoelektronenmikroskopie untersucht. Speziell wurden metallische Nanocluster untersucht, als selbstorganisierte Ensembles auf Silizium oder Glassubstraten, sowie ferner ein Metall-Chalcogenid (MoS2) Nanoröhren-Prototyp auf Silizium. Der Hauptteil der Untersuchungen war auf die Wechselwirkung von fs-Laserstrahlung mit den Nanopartikeln konzentriert. Die Energie der Lichtquanten war kleiner als die Austrittsarbeit der untersuchten Proben, so dass Ein-Photonen-Photoemission ausgeschlossen werden konnte. Unsere Untersuchungen zeigten, dass ausgehend von einem kontinuierlichen Metallfilm bis hin zu Clusterfilmen ein anderer Emissionsmechanismus konkurrierend zur Multiphotonen-Photoemission auftritt und für kleine Cluster zu dominieren beginnt. Die Natur dieses neuen Mechanismus` wurde durch verschiedenartige Experimente untersucht. Der Übergang von einem kontinuierlichen zu einem Nanopartikelfilm ist begleitet von einer Zunahme des Emissionsstroms von mehr als eine Größenordnung. Die Photoemissions-Intensität wächst mit abnehmender zeitlicher Breite des Laserpulses, aber diese Abhängigkeit wird weniger steil mit sinkender Partikelgröße. Die experimentellen Resultate wurden durch verschiedene Elektronenemissions-Mechanismen erklärt, z.B. Multiphotonen-Photoemission (nPPE), thermionische Emission und thermisch unterstützte nPPE sowie optische Feldemission. Der erste Mechanismus überwiegt für kontinuierliche Filme und Partikel mit Größen oberhalb von mehreren zehn Nanometern, der zweite und dritte für Filme von Nanopartikeln von einer Größe von wenigen Nanometern. Die mikrospektroskopischen Messungen bestätigten den 2PPE-Emissionsmechanismus von dünnen Silberfilmen bei „blauer“ Laseranregung (hν=375-425nm). Das Einsetzen des Ferminiveaus ist relativ scharf und verschiebt sich um 2hν, wenn die Quantenenergie erhöht wird, wogegen es bei „roter“ Laseranregung (hν=750-850nm) deutlich verbreitert ist. Es zeigte sich, dass mit zunehmender Laserleistung die Ausbeute von niederenergetischen Elektronen schwächer zunimmt als die Ausbeute von höherenergetischen Elektronen nahe der Fermikante in einem Spektrum. Das ist ein klarer Hinweis auf eine Koexistenz verschiedener Emissionsmechanismen in einem Spektrum. Um die Größenabhängigkeit des Emissionsverhaltens theoretisch zu verstehen, wurde ein statistischer Zugang zur Lichtabsorption kleiner Metallpartikel abgeleitet und diskutiert. Die Elektronenemissionseigenschaften bei Laseranregung wurden in zusätzlichen Untersuchungen mit einer anderen Anregungsart verglichen, der Passage eines Tunnelstroms durch einen Metall-Clusterfilm nahe der Perkolationsschwelle. Die elektrischen und Emissionseigenschaften von stromtragenden Silberclusterfilmen, welche in einer schmalen Lücke (5-25 µm Breite) zwischen Silberkontakten auf einem Isolator hergestellt wurden, wurden zum ersten Mal mit einem Emissions-Elektronenmikroskop (EEM) untersucht. Die Elektronenemission beginnt im nicht-Ohmschen Bereich der Leitungsstrom-Spannungskurve des Clusterfilms. Wir untersuchten das Verhalten eines einzigen Emissionszentrums im EEM. Es zeigte sich, dass die Emissionszentren in einem stromleitenden Silberclusterfilm Punktquellen für Elektronen sind, welche hohe Emissions-Stromdichten (mehr als 100 A/cm2) tragen können. Die Breite der Energieverteilung der Elektronen von einem einzelnen Emissionszentrum wurde auf etwa 0.5-0.6 eV abgeschätzt. Als Emissionsmechanismus wird die thermionische Emission von dem „steady-state“ heißen Elektronengas in stromdurchflossenen metallischen Partikeln vorgeschlagen. Größenselektierte, einzelne auf Si-Substraten deponierte MoS2-Nanoröhren wurden mit einer Flugzeit-basierten Zweiphotonen-Photoemissions-Spektromikroskopie untersucht. Die Nanoröhren-Spektren wiesen bei fs-Laser Anregung eine erstaunlich hohe Emissionsintensität auf, deutlich höher als die SiOx Substratoberfläche. Dagegen waren die Röhren unsichtbar bei VUV-Anregung bei hν=21.2 eV. Eine ab-initio-Rechnung für einen MoS2-Slab erklärt die hohe Intensität durch eine hohe Dichte freier intermediärer Zustände beim Zweiphotonen-Übergang bei hν=3.1 eV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Untersuchung zum Einfluss der ACD-CPR (Aktive Kompressions- Dekompressions-Reanimation) mit während der Dekompressionsphase blockiertem Gasfluss (Impedance-Threshold-Device) im Vergleich zur Standardreanimationsrechnik auf die Kurzzeit-Überlebensrate von Patienten mit präklinisch aufgetretenem Herzkreislaufstillstand. Die Studie vergleicht die ACD-ITD-CPR gegen die Standard-CPR bei Patienten mit präklinischem Herkreislaufstillstand. Primär untersuchter Parameter war die Ein-Stunden-Überlebensrate nach Krankenhausaufnahme. Sekundär wurden die Tastbarkeit eines Pulses unter CPR, die Wiederkehr des Spontankreislaufs (ROSC), die Rate an Krankenhausaufnahmen, 24-Stunden-Überleben und Krankenhausentlassungen untersucht. Außerdem wurde das neurologische Outcome evaluiert. Die Studie fand in Mainz statt; Mainz bietet sich für die Durchführung notfallmedizinischer Studien in besonderem Maße an. Der Rettungsdienst der Stadt arbeitet nach dem in Deutschland üblichen zweigliedrigen System mit RA/RS auf RTWs und NA auf NAW/NEF. Die Studie wurde nach einer fünfmonatigen Pilotphase und extensivem Training beider Verfahren durchgeführt. Zusätzlich bestanden bei einigen der Beteiligten schon Erfahrungen mit ACD-CPR. Es ergaben sich signifikante Vorteile der ACD-ITD-CPR gegenüber der Standard-CPR hinsichtlich des primär untersuchten Parameters (51% vs. 32% p=0,006), außerdem statistisch auffällige Vorteile hinsichtlich der Pulstastbarkeit unter CPR (85% vs. 69%, p=0,008), der Wiederkehr des Spontankreislaufs (55% vs. 37%, p=0,016), der Rate der Krankenhausaufnahmen (52% vs. 36%, p=0.023) und des 24-Stunden-Überlebens (37% vs. 22%, p=0,033). Es ergaben sich keine statistisch auffälligen Unterschiede hinsichtlich der Rate an Krankenhausentlassungen und im neurologischen Outcome. Die Ergebnisse lassen den Schluss zu, dass die ACD-ITD die Kurzzeitüberlebensrate der Patienten mit außerklinischem Herzkreislaufstillstand verbessern kann. Eine Voraussetzung hierfür ist eine ausreichende und andauernde Ausbildung der beteiligten Helfer und/oder die Verfügbarkeit technisch verbesserter Lösungen. Weitere Untersuchungen zum Einfluss auf die Langzeitüberlebensraten und das neurologische Outcome scheinen angezeigt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The PhD thesis at hand consists of three parts and describes the petrogenetic evolution of Uralian-Alaskan-type mafic ultramafic complexes in the Ural Mountains, Russia. Uralian-Alaskan-type mafic-ultramafic complexes are recognized as a distinct class of intrusions. Characteristic petrologic features are the concentric zonation of a central dunite body grading outward into wehrlite, clinopyroxenite and gabbro, the absence of orthopyroxene and frequently occurring platinum group element (PGE) mineralization. In addition, the presence of ferric iron-rich spinel discriminates Uralian-Alaskan-type complexes from most other mafic ultramafic rock assemblages. The studied Uralian-Alaskan-type complexes (Nizhnii Tagil, Kytlym and Svetley Bor) belong to the southern part of a 900 km long, N–S-trending chain of similar intrusions between the Main Uralian Fault to the west and the Serov-Mauk Fault to the east. The first chapter of this thesis studies the evolution of the ultramafic rocks tracing the compositional variations of rock forming and accessory minerals. The comparison of the chemical composition of olivine, clinopyroxene and chromian spinel from the Urals with data from other localities indicates that they are unique intrusions having a characteristic spinel and clinopyroxene chemistry. Laser ablation-ICPMS (LA-ICPMS ) analyses of trace element concentrations in clinopyroxene are used to calculate the composition of their parental melt which is characterized by enriched LREE (0.5-5.2 prim. mantle) and other highly incompatible elements (U, Th, Ba, Rb) relative to the HREE (0.25-2.0 prim. mantle). A subduction-related geotectonic setting is indicated by a positive anomaly for Sr and negative anomalies for Ti, Zr and Hf. The mineral compositions monitor the evolution of the parental magmas and decipher differences between the studied complexes. In addition, the observed variation in LREE/HREE (for example La/Lu = 2-24) can be best explained with the model of an episodically replenished and erupted open magma chamber system with the extensive fractionation of olivine, spinel and clinopyroxene. The data also show that ankaramites in a subduction-related geotectonic setting could represent parental magmas of Uralian-Alaskan-type complexes. The second chapter of the thesis discusses the chemical variation of major and trace elements in rock-forming minerals of the mafic rocks. Electron microprobe and LA-ICPMS analyses are used to quantitatively describe the petrogenetic relationship between the different gabbroic lithologies and their genetic link to the ultramafic rocks. The composition of clinopyroxene identifies the presence of melts with different trace element abundances on the scale of a thin section and suggests the presence of open system crustal magma chambers. Even on a regional scale the large variation of trace element concentrations and ratios in clinopyroxene (e.g. La/Lu = 3-55) is best explained by the interaction of at least two fundamentally different magma types at various stages of fractionation. This requires the existence of a complex magma chamber system fed with multiple pulses of magmas from at least two different coeval sources in a subduction-related environment. One source produces silica saturated Island arc tholeiitic melts. The second source produces silica undersaturated, ultra-calcic, alkaline melts. Taken these data collectively, the mixing of the two different parental magmas is the dominant petrogenetic process explaining the observed chemical variations. The results further imply that this is an intrinsic feature of Uralian-Alaskan-type complexes and probably of many similar mafic-ultramafic complexes world-wide. In the third chapter of this thesis the major element composition of homogeneous and exsolved spinel is used as a petrogenetic indicator. Homogeneous chromian spinel in dunites and wehrlites monitors the fractionation during the early stages of the magma chamber and the onset of clinopyroxene fractionation as well as the reaction of spinel with interstitial liquid. Exsolved spinel is present in mafic and ultramafic rocks from all three studied complexes. Its composition lies along a solvus curve which defines an equilibrium temperature of 600°C, given that spinel coexists with olivine. This temperature is considered to be close to the temperature of the host rocks into which the studied Uralian-Alaskan-type complexes intruded. The similarity of the exsolution temperatures in the different complexes over a distance of several hundred kilometres implies a regional tectonic event that terminated the exsolution process. This event is potentially associated with the final exhumation of the Uralian-Alaskan-type complexes along the Main Uralian Fault and the Serov-Mauk Fault in the Uralian fold belt.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Key technology applications like magnetoresistive sensors or the Magnetic Random Access Memory (MRAM) require reproducible magnetic switching mechanisms. i.e. predefined remanent states. At the same time advanced magnetic recording schemes push the magnetic switching time into the gyromagnetic regime. According to the Landau-Lifschitz-Gilbert formalism, relevant questions herein are associated with magnetic excitations (eigenmodes) and damping processes in confined magnetic thin film structures.rnObjects of study in this thesis are antiparallel pinned synthetic spin valves as they are extensively used as read heads in today’s magnetic storage devices. In such devices a ferromagnetic layer of high coercivity is stabilized via an exchange bias field by an antiferromagnet. A second hard magnetic layer, separated by a non-magnetic spacer of defined thickness, aligns antiparallel to the first. The orientation of the magnetization vector in the third ferromagnetic NiFe layer of low coercivity - the freelayer - is then sensed by the Giant MagnetoResistance (GMR) effect. This thesis reports results of element specific Time Resolved Photo-Emission Electron Microscopy (TR-PEEM) to image the magnetization dynamics of the free layer alone via X-ray Circular Dichroism (XMCD) at the Ni-L3 X-ray absorption edge.rnThe ferromagnetic systems, i.e. micron-sized spin valve stacks of typically deltaR/R = 15% and Permalloy single layers, were deposited onto the pulse leading centre stripe of coplanar wave guides, built in thin film wafer technology. The ferromagnetic platelets have been applied with varying geometry (rectangles, ellipses and squares), lateral dimension (in the range of several micrometers) and orientation to the magnetic field pulse to study the magnetization behaviour in dependence of these magnitudes. The observation of magnetic switching processes in the gigahertz range became only possible due to the joined effort of producing ultra-short X-ray pulses at the synchrotron source BESSY II (operated in the so-called low-alpha mode) and optimizing the wave guide design of the samples for high frequency electromagnetic excitation (FWHM typically several 100 ps). Space and time resolution of the experiment could be reduced to d = 100 nm and deltat = 15 ps, respectively.rnIn conclusion, it could be shown that the magnetization dynamics of the free layer of a synthetic GMR spin valve stack deviates significantly from a simple phase coherent rotation. In fact, the dynamic response of the free layer is a superposition of an averaged critically damped precessional motion and localized higher order spin wave modes. In a square platelet a standing spin wave with a period of 600 ps (1.7 GHz) was observed. At a first glance, the damping coefficient was found to be independent of the shape of the spin-valve element, thus favouring the model of homogeneous rotation and damping. Only by building the difference in the magnetic rotation between the central region and the outer rim of the platelet, the spin wave becomes visible. As they provide an additional efficient channel for energy dissipation, spin waves contribute to a higher effective damping coefficient (alpha = 0.01). Damping and magnetic switching behaviour in spin valves thus depend on the geometry of the element. Micromagnetic simulations reproduce the observed higher-order spin wave mode.rnBesides the short-run behaviour of the magnetization of spin valves Permalloy single layers with thicknesses ranging from 3 to 40 nm have been studied. The phase velocity of a spin wave in a 3 nm thick ellipse could be determined to 8.100 m/s. In a rectangular structure exhibiting a Landau-Lifschitz like domain pattern, the speed of the field pulse induced displacement of a 90°-Néel wall has been determined to 15.000 m/s.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cytochrom c Oxidase (CcO), der Komplex IV der Atmungskette, ist eine der Häm-Kupfer enthaltenden Oxidasen und hat eine wichtige Funktion im Zellmetabolismus. Das Enzym enthält vier prosthetische Gruppen und befindet sich in der inneren Membran von Mitochondrien und in der Zellmembran einiger aerober Bakterien. Die CcO katalysiert den Elektronentransfer (ET) von Cytochrom c zu O2, wobei die eigentliche Reaktion am binuklearen Zentrum (CuB-Häm a3) erfolgt. Bei der Reduktion von O2 zu zwei H2O werden vier Protonen verbraucht. Zudem werden vier Protonen über die Membran transportiert, wodurch eine elektrochemische Potentialdifferenz dieser Ionen zwischen Matrix und Intermembranphase entsteht. Trotz ihrer Wichtigkeit sind Membranproteine wie die CcO noch wenig untersucht, weshalb auch der Mechanismus der Atmungskette noch nicht vollständig aufgeklärt ist. Das Ziel dieser Arbeit ist, einen Beitrag zum Verständnis der Funktion der CcO zu leisten. Hierzu wurde die CcO aus Rhodobacter sphaeroides über einen His-Anker, der am C-Terminus der Untereinheit II angebracht wurde, an eine funktionalisierte Metallelektrode in definierter Orientierung gebunden. Der erste Elektronenakzeptor, das CuA, liegt dabei am nächsten zur Metalloberfläche. Dann wurde eine Doppelschicht aus Lipiden insitu zwischen die gebundenen Proteine eingefügt, was zur sog. proteingebundenen Lipid-Doppelschicht Membran (ptBLM) führt. Dabei musste die optimale Oberflächenkonzentration der gebundenen Proteine herausgefunden werden. Elektrochemische Impedanzspektroskopie(EIS), Oberflächenplasmonenresonanzspektroskopie (SPR) und zyklische Voltammetrie (CV) wurden angewandt um die Aktivität der CcO als Funktion der Packungsdichte zu charakterisieren. Der Hauptteil der Arbeit betrifft die Untersuchung des direkten ET zur CcO unter anaeroben Bedingungen. Die Kombination aus zeitaufgelöster oberflächenverstärkter Infrarot-Absorptionsspektroskopie (tr-SEIRAS) und Elektrochemie hat sich dafür als besonders geeignet erwiesen. In einer ersten Studie wurde der ET mit Hilfe von fast scan CV untersucht, wobei CVs von nicht-aktivierter sowie aktivierter CcO mit verschiedenen Vorschubgeschwindigkeiten gemessen wurden. Die aktivierte Form wurde nach dem katalytischen Umsatz des Proteins in Anwesenheit von O2 erhalten. Ein vier-ET-modell wurde entwickelt um die CVs zu analysieren. Die Methode erlaubt zwischen dem Mechanismus des sequentiellen und des unabhängigen ET zu den vier Zentren CuA, Häm a, Häm a3 und CuB zu unterscheiden. Zudem lassen sich die Standardredoxpotentiale und die kinetischen Koeffizienten des ET bestimmen. In einer zweiten Studie wurde tr-SEIRAS im step scan Modus angewandt. Dafür wurden Rechteckpulse an die CcO angelegt und SEIRAS im ART-Modus verwendet um Spektren bei definierten Zeitscheiben aufzunehmen. Aus diesen Spektren wurden einzelne Banden isoliert, die Veränderungen von Vibrationsmoden der Aminosäuren und Peptidgruppen in Abhängigkeit des Redoxzustands der Zentren zeigen. Aufgrund von Zuordnungen aus der Literatur, die durch potentiometrische Titration der CcO ermittelt wurden, konnten die Banden versuchsweise den Redoxzentren zugeordnet werden. Die Bandenflächen gegen die Zeit aufgetragen geben dann die Redox-Kinetik der Zentren wieder und wurden wiederum mit dem vier-ET-Modell ausgewertet. Die Ergebnisse beider Studien erlauben die Schlussfolgerung, dass der ET zur CcO in einer ptBLM mit größter Wahrscheinlichkeit dem sequentiellen Mechanismus folgt, was dem natürlichen ET von Cytochrom c zur CcO entspricht.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In der vorliegenden Arbeit wurden Untersuchungen zum Mechanismus, der Dynamik und der Kontrolle des elektronischen Energietransfers in multichromophoren Modellsystemen durchgeführt. Als Untersuchungsmethoden wurden hauptsächlich die konfokale Einzelmolekülspektroskopie und die Quantenchemie eingesetzt. Der Aufbau des Einzelmolekülmikroskops wurde bezüglich der Anregungs- und Detektionskomponenten variiert, um die unterschiedlichen Experimente durchzuführen. Die quantenchemischen Rechnungen wurden auf Dichtefunktional- und Coupled-Cluster-Niveau durchgeführt. Die aus den Rechnungen erhaltenen zusätzlichen Informationen über experimentell zum Teil schwer zugängliche Eigenschaften der Farbstoffe unterstützten die Interpretation der experimentellen Befunde. rnIn früheren Untersuchungen der AG Basché wurden die Energietransfer-Raten von Donor-Akzeptor-Systemen gemessen, die erhebliche Abweichungen von nach der Förster-Theorie berechneten Raten zeigten. Daher war ein Ziel der vorliegenden Arbeit, diese Abweichungen zu erklären. Zu diesem Zweck wurde die Geometrie der Diaden experimentell untersucht, sowie die elektronische Kopplung zwischen den Chromophoren quantenchemisch berechnet. Die relative Orientierung der Chromophore in den Diaden wurde in einem Einzelmolekül-Experiment mit rotierender Anregungspolarisation abgefragt. Die erhaltenen Winkelverteilungen konnten schließlich eindeutig auf die Flexibilität der die Chromophore verbrückenden Oligophenyl-Einheiten zurückgeführt werden. Die Unterschiede der gemessenen Energietransfer-Raten zu den nach der Förster-Theorie ermittelten Werten konnten jedoch nicht über die molekulare Flexibilität der Systeme erklärt werden. Aufklärung über die Diskrepanzen zur Förster-Theorie ergaben die quantenchemischen Rechnungen. In Rahmen dieser Arbeit wurde zum ersten Mal die Coupled-Cluster-Theorie zur Berechnung der elektronischen Kopplung eingesetzt. Die Betrachtung der isolierten Chromophore reichte aber nicht aus, um die gemessenen Abweichungen von der Förster-Theorie zu erklären. Erst über die Berücksichtigung der molekularen Brücke konnten die gefunden Abweichungen erklärt werden. Die deutliche Verstärkung der elektronischen Kopplung ist auf die Polarisierbarkeit der Brücke zurückzuführen.rnNach diesen Betrachtungen stand die Kontrolle des Energietransfers im Fokus der weiteren Untersuchungen. In den durchgeführten Einzelmolekülexperimenten wurden die Chromophore der Donor-Akzeptor-Systeme selektiv mit zwei Laserpulsen unterschiedlicher Wellenlänge angeregt. Beim gleichzeitigen Anregen beider Chromophore wurde Singulett-Singulett-Annihilation (SSA) induziert, ein Energietransferprozess, bei dem die Anregungsenergie vom vorigen Akzeptor zum vorigen Donor übertragen wird. Da über SSA Fluoreszenzphotonen gelöscht wurden, konnte über den Abstand der Laserpulse die Fluoreszenzintensität des einzelnen Moleküls moduliert werden. Konzeptionell verwandte Einzelmolekülexperimente wurden an einem weiteren molekularen System durchgeführt, das aus einem Kern und einer Peripherie bestand. Fluoreszenzauszeiten des Gesamtsystems bei selektiver Anregung des Kerns wurden auf die Population eines Triplett-Zustandes zurückgeführt, der die Fluoreszenz der Peripherie löschte. rnAbschließend wurde der SSA-Prozess zwischen zwei gleichartigen Chromophoren untersucht. Es wurde eine Methode entwickelt, die es zum ersten Mal erlaubte, die SSA-Zeitkonstante individueller Moleküle zu bestimmen. Hierfür wurden die Daten der gemessenen Photonen-Koinzidenzhistogramme mittels eines im Rahmen dieser Arbeit hergeleiteten analytischen Zusammenhangs ausgewertet, der über Monte-Carlo-Simulationen bestätigt wurde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A field of computational neuroscience develops mathematical models to describe neuronal systems. The aim is to better understand the nervous system. Historically, the integrate-and-fire model, developed by Lapique in 1907, was the first model describing a neuron. In 1952 Hodgkin and Huxley [8] described the so called Hodgkin-Huxley model in the article “A Quantitative Description of Membrane Current and Its Application to Conduction and Excitation in Nerve”. The Hodgkin-Huxley model is one of the most successful and widely-used biological neuron models. Based on experimental data from the squid giant axon, Hodgkin and Huxley developed their mathematical model as a four-dimensional system of first-order ordinary differential equations. One of these equations characterizes the membrane potential as a process in time, whereas the other three equations depict the opening and closing state of sodium and potassium ion channels. The membrane potential is proportional to the sum of ionic current flowing across the membrane and an externally applied current. For various types of external input the membrane potential behaves differently. This thesis considers the following three types of input: (i) Rinzel and Miller [15] calculated an interval of amplitudes for a constant applied current, where the membrane potential is repetitively spiking; (ii) Aihara, Matsumoto and Ikegaya [1] said that dependent on the amplitude and the frequency of a periodic applied current the membrane potential responds periodically; (iii) Izhikevich [12] stated that brief pulses of positive and negative current with different amplitudes and frequencies can lead to a periodic response of the membrane potential. In chapter 1 the Hodgkin-Huxley model is introduced according to Izhikevich [12]. Besides the definition of the model, several biological and physiological notes are made, and further concepts are described by examples. Moreover, the numerical methods to solve the equations of the Hodgkin-Huxley model are presented which were used for the computer simulations in chapter 2 and chapter 3. In chapter 2 the statements for the three different inputs (i), (ii) and (iii) will be verified, and periodic behavior for the inputs (ii) and (iii) will be investigated. In chapter 3 the inputs are embedded in an Ornstein-Uhlenbeck process to see the influence of noise on the results of chapter 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plasmabasierte Röntgenlaser sind aufgrund ihrer kurzen Wellenlänge und schma-rnlen spektralen Bandbreite attraktive Diagnose-Instrumente in einer Vielzahl potentieller Anwendungen, beispielsweise in den Bereichen Spektroskopie, Mikroskopie und EUV-Lithografie. Dennoch sind Röntgenlaser zum heutigen Stand noch nicht sehr weit verbreitet, was vorwiegend auf eine zu geringe Pulsenergie und für manche Anwendungen nicht hinreichende Strahlqualität zurückzuführen ist. In diesem Zusammenhang wurden in den letzten Jahren bedeutende Fortschritte erzielt. Die gleichzeitige Weiterentwicklung von Pumplasersystemen und Pumpmechanismen ermöglichte es, kompakte Röntgenlaserquellen mit bis zu 100 Hz zu betreiben. Um gleichzeitig höhere Pulsenergien, höhere Strahlqualität und volle räumliche Kohärenz zu erhalten, wurden intensive Studien theoretischer und experimenteller Natur durchgeführt. In diesem Kontext wurde in der vorliegenden Arbeit ein experimenteller Aufbau zur Kombination von zwei Röntgenlaser-Targets entwickelt, die sogenannte Butterfly-Konfiguration. Der erste Röntgenlaser wird dabei als sogenannter Seed für das zweite, als Verstärker dienende Röntgenlasermedium verwendet (injection-seeding). Aufrndiese Weise werden störende Effekte vermieden, welche beim Entstehungsprozessrndes Röntgenlasers durch die Verstärkung von spontaner Emission zustande kom-rnmen. Unter Verwendung des ebenfalls an der GSI entwickelten Double-Pulse Gra-rnzing Incidence Pumpschemas ermöglicht das hier vorgestellte Konzept, erstmaligrnbeide Röntgenlasertargets effizient und inklusive Wanderwellenanregung zu pum-rnpen.rnBei einer ersten experimentellen Umsetzung gelang die Erzeugung verstärkter Silber-Röntgenlaserpulse von 1 µJ bei 13.9 nm Wellenlänge. Anhand der gewonnenen Daten erfolgte neben dem Nachweis der Verstärkung die Bestimmung der Lebensdauer der Besetzungsinversion zu 3 ps. In einem Nachfolgeexperiment wurden die Eigenschaften eines Molybdän-Röntgenlaserplasmas näher untersucht. Neben dem bisher an der GSI angewandten Pumpschema kam in dieser Strahlzeit noch eine weitere Technik zum Einsatz, welche auf einem zusätzlichen Pumppuls basierte. In beiden Schemata gelang neben dem Nachweis der Verstärkung die zeitliche und räumliche Charakterisierung des Verstärkermediums. Röntgenlaserpulse mit bis zu 240 nJ bei einer Wellenlänge von 18.9 nm wurden nachgewiesen. Die erreichte Brillanz der verstärkten Pulse lag ca. zwei Größenordnungen über der des ursprünglichen Seeds und mehr als eine Größenordnung über der Brillanz eines Röntgenlasers, dessen Erzeugung auf der Verwendung eines einzelnen Targets basierte. Das in dieser Arbeitrnentwickelte und experimentell verifizierte Konzept birgt somit das Potential, extrem brillante plasmabasierte Röntgenlaser mit vollständiger räumlicher und zeitlicher Kohärenz zu erzeugen.rnDie in dieser Arbeit diskutierten Ergebnisse sind ein wesentlicher Beitrag zu der Entwicklung eines Röntgenlasers, der bei spektroskopischen Untersuchungen von hochgeladenen Schwerionen eingesetzt werden soll. Diese Experimente sind amrnExperimentierspeicherring der GSI und zukünftig auch am High-Energy StoragernRing der FAIR-Anlage vorgesehen.rn