46 resultados para DOSES
Resumo:
Organic anion-transporting polypeptide 1B1 (OATP1B1), encoded by the SLCO1B1 gene, is an influx transporter expressed on the sinusoidal membrane of human hepatocytes. The common c.521T>C (p.Val174Ala) single-nucleotide polymorphism (SNP) of the SLCO1B1 gene has been associated with reduced OATP1B1 transport activity in vitro and increased plasma concentrations of several of its substrate drugs in vivo in humans. Another common SNP of the SLCO1B1 gene, c.388A>G (p.Asn130Asp), defining the SLCO1B1*1B (c.388G-c.521T) haplotype, has been associated with increased OATP1B1 transport activity in vitro. The aim of this thesis was to investigate the role of SLCO1B1 polymorphism in the pharmacokinetics of the oral antidiabetic drugs repaglinide, nateglinide, rosiglitazone, and pioglitazone. Furthermore, the effect of the SLCO1B1 c.521T>C SNP on the extent of interaction between gemfibrozil and repaglinide as well as the role of the SLCO1B1 c.521T>C SNP in the potential interaction between atorvastatin and repaglinide were evaluated. Five crossover studies with 2-4 phases were carried out, with 20-32 healthy volunteers in each study. The effects of the SLCO1B1 c.521T>C SNP on single doses of repaglinide, nateglinide, rosiglitazone, and pioglitazone were investigated in Studies I and V. In Study II, the effects of the c.521T>C SNP on repaglinide pharmacokinetics were investigated in a dose-escalation study, with repaglinide doses ranging from 0.25 to 2 mg. The effects of the SLCO1B1*1B/*1B genotype on repaglinide and nateglinide pharmacokinetics were investigated in Study III. In Study IV, the interactions of gemfibrozil and atorvastatin with repaglinide were evaluated in relation to the c.521T>C SNP. Plasma samples were collected for drug concentration determinations. The pharmacodynamics of repaglinide and nateglinide was assessed by measuring blood glucose concentrations. The mean area under the plasma repaglinide concentration-time curve (AUC) was ~70% larger in SLCO1B1 c.521CC participants than in c.521TT participants (P ≤ 0.001), but no differences existed in the pharmacokinetics of nateglinide, rosiglitazone, and pioglitazone between the two genotype groups. In the dose-escalation study, the AUC of repaglinide was 60-110% (P ≤ 0.001) larger in c.521CC participants than in c.521TT participants after different repaglinide doses. Moreover, the AUC of repaglinide increased linearly with repaglinide dose in both genotype groups (r > 0.88, P 0.001). The AUC of repaglinide was ~30% lower in SLCO1B1*1B/*1B participants than in SLCO1B1*1A/*1A (c.388AA-c.521TT) participants (P = 0.007), but no differences existed in the AUC of nateglinide between the two genotype groups. In the drug-drug interaction study, the mean increase in the repaglinide AUC by gemfibrozil was ~50% (P = 0.002) larger in c.521CC participants than in c.521TT participants, but the relative (7-8-fold) increases in the repaglinide AUC did not differ significantly between the genotype groups. In c.521TT participants, atorvastatin increased repaglinide peak plasma concentration and AUC by ~40% (P = 0.001) and ~20% (P = 0.033), respectively. In each study, after repaglinide administration, there was a tendency towards lower blood glucose concentrations in c.521CC participants than in c.521TT participants. In conclusion, the SLCO1B1 c.521CC genotype is associated with increased and the SLCO1B1*1B/*1B genotype with decreased plasma concentrations of repaglinide, consistent with reduced and enhanced hepatic uptake, respectively. Inhibition of OATP1B1 plays a limited role in the interaction between gemfibrozil and repaglinide. Atorvastatin slightly raises plasma repaglinide concentrations, probably by inhibiting OATP1B1. The findings on the effect of SLCO1B1 polymorphism on the pharmacokinetics of the drugs studied suggest that in vivo in humans OATP1B1 significantly contributes to the hepatic uptake of repaglinide, but not to that of nateglinide, rosiglitazone, or pioglitazone. SLCO1B1 polymorphism may be associated with clinically significant differences in blood glucose-lowering response to repaglinide, but probably has no effect on the response to nateglinide, rosiglitazone, or pioglitazone.
Resumo:
Uveal melanoma is the most common primary intraocular malignancy in adults. Vision in the affected eye is threatened by both the tumor and side-effects from the treatments currently available. Poor prognosis for saving vision increases with tumor size and, consequently, enucleation has been the treatment of choice for large uveal melanomas in most centers. However, increasing evidence suggests that no survival benefit is gained (nor lost) by enucleation as compared to eye-conserving methods. The Helsinki University Eye Hospital has since 1990 offered episcleral iodine-125 plaque brachytherapy (IBT) for all patients unwilling to undergo enucleation for a large uveal melanoma. The primary aim of this study was to assess survival, local tumor recurrence and preservation of the eye and vision after IBT in a population-based series of 97 patients with uveal melanomas classified as large by the Collaborative Ocular Melanoma Study (COMS) criteria. Further aims included reporting the incidence of side-effects and assessing the role of intraocular dose distribution and clinical risk factors in their development. Finally, means to improve the current treatment were investigated by using computer models to compare existing plaques with collimating ones and by comparing the outcome of a subgroup of 54 IBT patients with very thick tumors with 33 patients with similarly-sized tumors managed with transscleral local resection (TSR) in Liverpool, United Kingdom. Kaplan-Meier estimates of all-cause and melanoma-specific survival at 5 years after IBT were 62% and 65%, respectively, and visually comparable with the survival experience of patients reported after enucleation by the COMS. Local recurrence developed in 6% of eyes and 84% of eyes were conserved at 5 years. Visual prognosis was guarded with 11% avoiding loss of 20/70 vision and 26% avoiding loss of 20/400 vision in the tumor eye at 2 years. Large tumor height and short distance from the posterior pole were independently associated with loss of vision. Using cumulative incidence analysis to account for competing risks, such as enucleation and metastatic death, the 5-year incidence of cataract after IBT was 79%, glaucoma 60%, optic neuropathy 46%, maculopathy 52%, persistent or recurring retinal detachment (RD) 25%, and vitreous hemorrhage 36%. In multivariate competing risks regression models, increasing tumor height was associated with cataract, iris neovascularization and RD. Maculopathy and optic neuropathy were associated with distance from the tumor to the respective structure. Median doses to the tumor apex, macula and optic disc were 81 Gy (range, 40-158), 79 Gy (range, 12-632), and 83 Gy (range, 10-377), respectively. Dose to the optic disc was independently associated with optic neuropathy, and both dose to the optic disc and dose to the macula predicted vision loss after IBT. Simulated treatment using collimating plaques resulted in clinically meaningful reduction in both optic disc (median reduction, 30 Gy) and macular (median reduction, 36 Gy) doses as compared to the actual treatment with standard plaques. In the subgroup of patients with uveal melanomas classified as large because of tumor height, cumulative incidence analysis revealed that while long-term preservation of 20/70 vision was rare after both IBT and TSR, preservation of 20/400 vision was better after TSR (32% vs. 5% at 5 years). In multivariate logistic regression models, TSR was independently associated with better preservation of 20/400 vision (OR 0.03 at 2 years, P=0.005) No cases of secondary glaucoma were observed after TSR and optic neuropathy was rare. However, local tumor recurrence was more common after TSR than it was after IBT (Cumulative incidence 41% vs. 7% at 5 years, respectively). In terms of survival, IBT seems to be a safe alternative to enucleation in managing large uveal melanomas. Local tumor control is no worse than with medium-sized tumors and the chances of avoiding secondary enucleation are good. Unfortunately, side-effects from radiotherapy are frequent, especially in thick tumors, and long-term prognosis of saving vision is consequently guarded. Some complications can be limited by using collimating plaques and by managing uveal melanomas that are large because of tumor height with TSR instead of IBT. However, the patient must be willing to accept a substantial risk of local tumor recurrence after TSR and it is best suited for cases in which the preservation of vision in the tumor eye is critical.
Resumo:
Intrahepatic cholestasis of pregnancy (ICP) is the most common cholestatic liver disease during pregnancy. The reported incidence varies from 0.4 to 15% of full-term pregnancies. The etiology is heterogeneous but familial clustering is known to occur. Here we have studied the genetic background, epidemiology, and long-term hepatobiliary consequences of ICP. In a register-based nation-wide study (n=1 080 310) the incidence of ICP was 0.94% during 1987-2004. A slightly higher incidence, 1.3%, was found in a hospital-based series (n=5304) among women attending the University Hospital of Helsinki in 1992-1993. Of these 16% (11/69) were familial and showed a higher (92%) recurrence rate than the sporadic (40%) cases. In the register-based epidemiological study, advanced maternal age and, to a lesser degree, parity were identified as new risk factors for ICP. The risk was 3-fold higher in women >39 years of age compared to women <30 years. Multiple pregnancy also associated with an elevated risk. In a genetic study we found no association of ICP with the genes regulating bile salt transport (ABCB4, ABCB11 and ATP8B1). The livers of postmenopausal women with a history of ICP tolerated well the short-term exposure to oral and transdermal estradiol, although the doses used were higher than those in routine clinical use. The response of serum levels of sex hormone-binding globulin (SHBG) to oral estradiol was slightly reduced in the ICP group. Transdermal estradiol had no effect on C-reactive protein (CRP) or SHBG. A number of liver and biliary diseases were found to be associated with ICP. Women with a history of ICP showed elevated risks for non-alcoholic liver cirrhosis (8.2 CI 1.9-36), cholelithiasis and cholecystitis (3.7 CI 3.2-4.2), hepatitis C (3.5 CI 1.6-7.6) and non-alcoholic pancreatitis (3.2 CI 1.7-5.7). In conclusion, ICP complicates around 1% of all full-term pregnancies in Finland and its incidence has remained unchanged since 1987. It is familial in 16% of cases with a higher recurrence rate. Although the cause remains unknown, several risk factors, namely advanced maternal age, parity and multiple pregnancies, can be identified. Both oral and transdermal regimens of postmenopausal hormone therapy (HT) are safe for women with a history of ICP when liver function is considered. Some ICP patients are at risk of other liver and biliary diseases and, contrary to what has been thought, a follow-up is warranted.
Resumo:
Cyclosporine is an immunosuppressant drug with a narrow therapeutic index and large variability in pharmacokinetics. To improve cyclosporine dose individualization in children, we used population pharmacokinetic modeling to study the effects of developmental, clinical, and genetic factors on cyclosporine pharmacokinetics in altogether 176 subjects (age range: 0.36–20.2 years) before and up to 16 years after renal transplantation. Pre-transplantation test doses of cyclosporine were given intravenously (3 mg/kg) and orally (10 mg/kg), on separate occasions, followed by blood sampling for 24 hours (n=175). After transplantation, in a total of 137 patients, cyclosporine concentration was quantified at trough, two hours post-dose, or with dose-interval curves. One-hundred-four of the studied patients were genotyped for 17 putatively functionally significant sequence variations in the ABCB1, SLCO1B1, ABCC2, CYP3A4, CYP3A5, and NR1I2 genes. Pharmacokinetic modeling was performed with the nonlinear mixed effects modeling computer program, NONMEM. A 3-compartment population pharmacokinetic model with first order absorption without lag-time was used to describe the data. The most important covariate affecting systemic clearance and distribution volume was allometrically scaled body weight i.e. body weight**3/4 for clearance and absolute body weight for volume of distribution. The clearance adjusted by absolute body weight declined with age and pre-pubertal children (< 8 years) had an approximately 25% higher clearance/body weight (L/h/kg) than did older children. Adjustment of clearance for allometric body weight removed its relationship to age after the first year of life. This finding is consistent with a gradual reduction in relative liver size towards adult values, and a relatively constant CYP3A content in the liver from about 6–12 months of age to adulthood. The other significant covariates affecting cyclosporine clearance and volume of distribution were hematocrit, plasma cholesterol, and serum creatinine, explaining up to 20%–30% of inter-individual differences before transplantation. After transplantation, their predictive role was smaller, as the variations in hematocrit, plasma cholesterol, and serum creatinine were also smaller. Before transplantation, no clinical or demographic covariates were found to affect oral bioavailability, and no systematic age-related changes in oral bioavailability were observed. After transplantation, older children receiving cyclosporine twice daily as the gelatine capsule microemulsion formulation had an about 1.25–1.3 times higher bioavailability than did the younger children receiving the liquid microemulsion formulation thrice daily. Moreover, cyclosporine oral bioavailability increased over 1.5-fold in the first month after transplantation, returning thereafter gradually to its initial value in 1–1.5 years. The largest cyclosporine doses were administered in the first 3–6 months after transplantation, and thereafter the single doses of cyclosporine were often smaller than 3 mg/kg. Thus, the results suggest that cyclosporine displays dose-dependent, saturable pre-systemic metabolism even at low single doses, whereas complete saturation of CYP3A4 and MDR1 (P-glycoprotein) renders cyclosporine pharmacokinetics dose-linear at higher doses. No significant associations were found between genetic polymorphisms and cyclosporine pharmacokinetics before transplantation in the whole population for which genetic data was available (n=104). However, in children older than eight years (n=22), heterozygous and homozygous carriers of the ABCB1 c.2677T or c.1236T alleles had an about 1.3 times or 1.6 times higher oral bioavailability, respectively, than did non-carriers. After transplantation, none of the ABCB1 SNPs or any other SNPs were found to be associated with cyclosporine clearance or oral bioavailability in the whole population, in the patients older than eight years, or in the patients younger than eight years. In the whole population, in those patients carrying the NR1I2 g.-25385C–g.-24381A–g.-205_-200GAGAAG–g.7635G–g.8055C haplotype, however, the bioavailability of cyclosporine was about one tenth lower, per allele, than in non-carriers. This effect was significant also in a subgroup of patients older than eight years. Furthermore, in patients carrying the NR1I2 g.-25385C–g.-24381A–g.-205_-200GAGAAG–g.7635G–g.8055T haplotype, the bioavailability was almost one fifth higher, per allele, than in non-carriers. It may be possible to improve individualization of cyclosporine dosing in children by accounting for the effects of developmental factors (body weight, liver size), time after transplantation, and cyclosporine dosing frequency/formulation. Further studies are required on the predictive value of genotyping for individualization of cyclosporine dosing in children.
Resumo:
Objective: Glucocorticoid therapy is used worldwide to treat various inflammatory and immune conditions, including inflammatory bowel disease (IBD). In IBD, 80% of the patients obtain a positive response to the therapy; however the development of glucocorticoid-related side-effects is common. Our aim was therefore to study the possibility of optimizing glucocorticoid therapy in children and adolescents with IBD by measuring circulating glucocorticoid bioactivity (GBA) and serum glucocorticoid-responsive biomarkers in patients receiving steroid treatment for active disease. Methods: A total of sixty-nine paediatric IBD patients from the Paediatric Outpatient Clinics of the University Hospitals of Helsinki and Tampere participated in the studies. Control patients included 101 non-IBD patients and 41 disease controls in remission. In patients with active disease, blood samples were withdrawn before the glucocorticoid therapy was started, at 2-4 weeks after the initiation of the steroid and at 1-month intervals thereafter. Clinical response to glucocorticoid treatment and the development of steroid adverse events was carefully registered. GBA was analyzed with a COS-1 cell bioassay. The measured glucocorticoid therapy-responsive biomarkers included adipocyte-derived adiponectin and leptin, bone turnover-related collagen markers amino-terminal type I procollagen propeptide (PINP) and carboxyterminal telopeptide of type I collagen (ICTP) as well as insulin-like growth factor 1 (IGF-1) and sex hormone-binding globulin (SHBG), and inflammatory marker high-sensitivity C-reactive protein (hs-CRP). Results: The most promising marker for glucocorticoid sensitivity was serum adiponectin that associated with steroid therapy–related adverse events. Serum leptin indicated a similar trend. In contrast, circulating GBA rose in all subjects receiving glucocorticoid treatment but did not associate with the clinical response to steroids or with glucocorticoid therapy-related side-effects. Of notice, young patients (<10 years) showed similar GBA levels than older patients, despite receiving higher weight-adjusted doses of glucocorticoid. Markers of bone formation were lower in children with active IBD than in the control patients, probably reflecting the suppressive effect of the active inflammation. The onset of the glucocorticoid therapy further suppressed bone turnover. Inflammatory marker hs-CRP decreased readily after the initiation of the steroid, however the decrease did not associate with the clinical response to glucocorticoids. Conclusions: This is the first study to show that adipocyte-derived adiponectin associates with steroid therapy-induced side-effects. Further studies are needed, but it is possible that the adiponectin measurement could aid the recognition of glucocorticoid-sensitive patients in the future. GBA and the other markers reflecting glucocorticoid activity in different tissues changed during the treatment, however their change did not correlate with the therapeutic response to steroids or with the development of glucocorticoid-related side effects and therefore cannot guide the therapy in these patients. Studies such as as the present one that combine clinical data with newly developed biomolecular technology are needed to step-by-step build a general picture of the glucocorticoid actions in different tissues.
Resumo:
The methods for estimating patient exposure in x-ray imaging are based on the measurement of radiation incident on the patient. In digital imaging, the useful dose range of the detector is large and excessive doses may remain undetected. Therefore, real-time monitoring of radiation exposure is important. According to international recommendations, the measurement uncertainty should be lower than 7% (confidence level 95%). The kerma-area product (KAP) is a measurement quantity used for monitoring patient exposure to radiation. A field KAP meter is typically attached to an x-ray device, and it is important to recognize the effect of this measurement geometry on the response of the meter. In a tandem calibration method, introduced in this study, a field KAP meter is used in its clinical position and calibration is performed with a reference KAP meter. This method provides a practical way to calibrate field KAP meters. However, the reference KAP meters require comprehensive calibration. In the calibration laboratory it is recommended to use standard radiation qualities. These qualities do not entirely correspond to the large range of clinical radiation qualities. In this work, the energy dependence of the response of different KAP meter types was examined. According to our findings, the recommended accuracy in KAP measurements is difficult to achieve with conventional KAP meters because of their strong energy dependence. The energy dependence of the response of a novel large KAP meter was found out to be much lower than with a conventional KAP meter. The accuracy of the tandem method can be improved by using this meter type as a reference meter. A KAP meter cannot be used to determine the radiation exposure of patients in mammography, in which part of the radiation beam is always aimed directly at the detector without attenuation produced by the tissue. This work assessed whether pixel values from this detector area could be used to monitor the radiation beam incident on the patient. The results were congruent with the tube output calculation, which is the method generally used for this purpose. The recommended accuracy can be achieved with the studied method. New optimization of radiation qualities and dose level is needed when other detector types are introduced. In this work, the optimal selections were examined with one direct digital detector type. For this device, the use of radiation qualities with higher energies was recommended and appropriate image quality was achieved by increasing the low dose level of the system.
Resumo:
Solar flares were first observed by plain eye in white light by William Carrington in England in 1859. Since then these eruptions in the solar corona have intrigued scientists. It is known that flares influence the space weather experienced by the planets in a multitude of ways, for example by causing aurora borealis. Understanding flares is at the epicentre of human survival in space, as astronauts cannot survive the highly energetic particles associated with large flares in high doses without contracting serious radiation disease symptoms, unless they shield themselves effectively during space missions. Flares may be at the epicentre of man s survival in the past as well: it has been suggested that giant flares might have played a role in exterminating many of the large species on Earth, including dinosaurs. Having said that prebiotic synthesis studies have shown lightning to be a decisive requirement for amino acid synthesis on the primordial Earth. Increased lightning activity could be attributed to space weather, and flares. This thesis studies flares in two ways: in the spectral and the spatial domain. We have extracted solar spectra using three different instruments, namely GOES (Geostationary Operational Environmental Satellite), RHESSI (Reuven Ramaty High Energy Solar Spectroscopic Imager) and XSM (X-ray Solar Monitor) for the same flares. The GOES spectra are low resolution obtained with a gas proportional counter, the RHESSI spectra are higher resolution obtained with Germanium detectors and the XSM spectra are very high resolution observed with a silicon detector. It turns out that the detector technology and response influence the spectra we see substantially, and are important to understanding what conclusions to draw from the data. With imaging data, there was not such a luxury of choice available. We used RHESSI imaging data to observe the spatial size of solar flares. In the present work the focus was primarily on current solar flares. However, we did make use of our improved understanding of solar flares to observe young suns in NGC 2547. The same techniques used with solar monitors were applied with XMM-Newton, a stellar X-ray monitor, and coupled with ground based Halpha observations these techniques yielded estimates for flare parameters in young suns. The material in this thesis is therefore structured from technology to application, covering the full processing path from raw data and detector responses to concrete physical parameter results, such as the first measurement of the length of plasma flare loops in young suns.
Resumo:
Solar UV radiation is harmful for life on planet Earth, but fortunately the atmospheric oxygen and ozone absorb almost entirely the most energetic UVC radiation photons. However, part of the UVB radiation and much of the UVA radiation reaches the surface of the Earth, and affect human health, environment, materials and drive atmospheric and aquatic photochemical processes. In order to quantify these effects and processes there is a need for ground-based UV measurements and radiative transfer modeling to estimate the amounts of UV radiation reaching the biosphere. Satellite measurements with their near-global spatial coverage and long-term data conti-nuity offer an attractive option for estimation of the surface UV radiation. This work focuses on radiative transfer theory based methods used for estimation of the UV radiation reaching the surface of the Earth. The objectives of the thesis were to implement the surface UV algorithm originally developed at NASA Goddard Space Flight Center for estimation of the surface UV irradiance from the meas-urements of the Dutch-Finnish built Ozone Monitoring Instrument (OMI), to improve the original surface UV algorithm especially in relation with snow cover, to validate the OMI-derived daily surface UV doses against ground-based measurements, and to demonstrate how the satellite-derived surface UV data can be used to study the effects of the UV radiation. The thesis consists of seven original papers and a summary. The summary includes an introduction of the OMI instrument, a review of the methods used for modeling of the surface UV using satellite data as well as the con-clusions of the main results of the original papers. The first two papers describe the algorithm used for estimation of the surface UV amounts from the OMI measurements as well as the unique Very Fast Delivery processing system developed for processing of the OMI data received at the Sodankylä satellite data centre. The third and the fourth papers present algorithm improvements related to the surface UV albedo of the snow-covered land. Fifth paper presents the results of the comparison of the OMI-derived daily erythemal doses with those calculated from the ground-based measurement data. It gives an estimate of the expected accuracy of the OMI-derived sur-face UV doses for various atmospheric and other conditions, and discusses the causes of the differences between the satellite-derived and ground-based data. The last two papers demonstrate the use of the satellite-derived sur-face UV data. Sixth paper presents an assessment of the photochemical decomposition rates in aquatic environment. Seventh paper presents use of satellite-derived daily surface UV doses for planning of the outdoor material weathering tests.
Resumo:
Silicon strip detectors are fast, cost-effective and have an excellent spatial resolution. They are widely used in many high-energy physics experiments. Modern high energy physics experiments impose harsh operation conditions on the detectors, e.g., of LHC experiments. The high radiation doses cause the detectors to eventually fail as a result of excessive radiation damage. This has led to a need to study radiation tolerance using various techniques. At the same time, a need to operate sensors approaching the end their lifetimes has arisen. The goal of this work is to demonstrate that novel detectors can survive the environment that is foreseen for future high-energy physics experiments. To reach this goal, measurement apparatuses are built. The devices are then used to measure the properties of irradiated detectors. The measurement data are analyzed, and conclusions are drawn. Three measurement apparatuses built as a part of this work are described: two telescopes measuring the tracks of the beam of a particle accelerator and one telescope measuring the tracks of cosmic particles. The telescopes comprise layers of reference detectors providing the reference track, slots for the devices under test, the supporting mechanics, electronics, software, and the trigger system. All three devices work. The differences between these devices are discussed. The reconstruction of the reference tracks and analysis of the device under test are presented. Traditionally, silicon detectors have produced a very clear response to the particles being measured. In the case of detectors nearing the end of their lifefimes, this is no longer true. A new method benefitting from the reference tracks to form clusters is presented. The method provides less biased results compared to the traditional analysis, especially when studying the response of heavily irradiated detectors. Means to avoid false results in demonstrating the particle-finding capabilities of a detector are also discussed. The devices and analysis methods are primarily used to study strip detectors made of Magnetic Czochralski silicon. The detectors studied were irradiated to various fluences prior to measurement. The results show that Magnetic Czochralski silicon has a good radiation tolerance and is suitable for future high-energy physics experiments.
Resumo:
Dioxins are organic toxicants that are known to impair tooth development, especially dental hard tissue formation. The most toxic dioxin congener is 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD). Further, clinical studies suggest that maternal smoking during pregnancy can affect child s tooth development. One of the main components of tobacco smoke is the group of non-halogenated polycyclic aromatic hydrocarbons (PAHs), a representative of which is 7,12-dimethylbenz[a]anthracene (DMBA). Tributyltin (TBT), an organic tin compound, has been shown to impair bone mineralization in experimental animals. In addition to exposure to organic toxicants, a well-established cause for enamel hypomineralization is excess fluoride intake. The principal aim of this thesis project was to examine in vitro if, in addition to dioxins, other organic environmental toxicants, like PAHs and organic tin compounds, have adverse effects on tooth development, specifically on formation and mineralization of the major dental hard tissues, the dentin and the enamel. The second aim was to investigate in vitro if fluoride could intensify the manifestation of the detrimental developmental dental effects elicited by TCDD. The study was conducted by culturing mandibular first and second molar tooth germs of E18 NMRI mouse embryos in a Trowell-type organ culture and exposing them to DMBA, TBT, and sodium fluoride (NaF) and/or TCDD at various concentrations during the secretory and mineralization stages of development. Specific methods used were HE-staining for studying cell and tissue morphology, BrdU-staining for cell proliferation, TUNEL-staining for apoptosis, and QPCR, in situ hybridization and immunohistochemistry for the expressions of selected genes associated with mineralization. This thesis work showed that DMBA, TBT, TCDD and NaF interfere with dentin and enamel formation of embryonic mouse tooth in vitro, and that fluoride can potentiate the harmful effect of TCDD. The results suggested that adverse effects of TBT involve altered expression of genes associated with mineralization, and that DMBA and TBT as well as NaF and TCDD together primarily affect dentin mineralization. Since amelogenesis does not start until mineralization of dentin begins, impaired enamel matrix secretion could be a secondary effect. Dioxins, PAHs and organotins are all liposoluble and can be transferred to the infant by breast-feeding. Since doses are usually very low, developmental toxicity on most of the organs is difficult to indentify clinically. However, tooth may act as an indicator of exposure, since the major dental hard tissues, the dentin and the enamel, are not replaced once they have been formed. Thus, disturbed dental hard tissue formation raises the question of more extensive developmental toxicity.
Resumo:
Congenital long QT syndrome (LQTS) is a familial disorder characterized by ventricular repolarization that makes carriers vulnerable to malignant ventricular tachycardia and sudden cardiac death. The three main subtypes (LQT1, LQT2 and LQT3) constitute 95% of cases. The disorder is characterized by a prolonged QT interval in electrocardiograms (ECG), but a considerable portion are silent carriers presenting normal (QTc < 440 ms) or borderline (QTc < 470 ms) QT interval. Genetic testing is available only for 60-70% of patients. A number of pharmaceutical compounds also affect ventricular repolarization, causing a clinically similar disorder called acquired long QT syndrome. LQTS carriers - who already have impaired ventricular repolarization - are especially vulnerable. In this thesis, asymptomatic genotyped LQTS mutation carriers with non-diagnostic resting ECG were studied. The body surface potential mapping (BSPM) system was utilized for ECG recording, and signals were analyzed with an automated analysis program. QT interval length, and the end part of the T wave, the Tpe interval, was studied during exercise stress testing and an epinephrine bolus test. In the latter, T wave morphology was also analyzed. The effect of cetirizine was studied in LQTS carriers and also with supra- therapeutic dose in healthy volunteers. At rest, LQTS mutation carriers had a slightly longer heart rate adjusted QTc interval than healthy subjects (427 ± 31 ms and 379 ± 26 ms; p<0.001), but significant overlapping existed. LQT2 mutation carriers had a conspicuously long Tpe-interval (113 ± 24 ms; compared to 79 ± 11 ms in LQT1, 81 ± 17 ms in LQT3 and 78 ± 10 ms in controls; p<0.001). In exercise stress tests, LQT1 mutation carriers exhibit a long QT interval at high heart rates and during recovery, whereas LQT2 mutation carriers have a long Tpe interval at the beginning of exercise and at the end of recovery at low heart rates. LQT3 mutation carriers exhibit prominent shortening of both QT and Tpe intervals during exercise. A small epinephrine bolus revealed disturbed repolarization, especially in LQT2 mutation carriers, who developed prolonged Tpe intervals. A higher epinephrine bolus caused abnormal T waves with a different T wave profile in LQTS mutation carriers compared to healthy controls. These effects were seen in LQT3 as well, a group that may easily escape other provocative tests. In the cetirizine test, the QT and Tpe intervals were not prolonged in LQTS mutation carriers or in healthy controls. Subtype-specific findings in exercise test and epinephrine bolus test help to diagnose silent LQTS mutation carriers and to guide subtype-specific treatments. The Tpe interval, which signifies the repolarization process, seems to be a sensitive marker of disturbed repolarization along with the QT interval, which signifies the end of repolarization. This method may be used in studying compounds that are suspected to affect repolarization. Cetirizine did not adversely alter ventricular repolarization and would not be pro-arrhythmic in common LQT1 and LQT2 subtypes when used at its recommended doses.
Resumo:
Using 58 audio recorded sessions of psychoanalysis (coming from two analysts and three patients) as data and conversation analysis as method, this paper shows how psychoanalysts deal with patients’ responses to interpretations. After the analyst offers an interpretation, the patient responds: at that point (in the “third position”), the analysts recurrently modify the tenor of the description from what it was in the patients’ responses. They intensify the emotional valence of the description, or they reveal layers of the patients’ experience other than those that the patient reported. Both are usually accomplished in an implicit, non-marked way, and they discreetly index possible opportunities for the patients to modify their understandings of the initial interpretation. Although the patients usually do not fully endorse these modifications, the data available suggests that during the sessions that follow, the participants do work with the aspects of patients’ experience that the analyst highlighted. In discussion, it is suggested that actions that the psychoanalysts produce in therapy, such as choices of turn design in third position, may be informed by working understanding of the minds and mental conflicts of individual patients, alongside the more general therapeutic model of mind they hold to.
Resumo:
Ketoprofeeni on yleisesti käytetty ei-steroidinen tulehduskipulääke (NSAID) lampaiden ja sikojen kivunlievityksessä. Tietoa ketoprofeenin oikeista annosmääristä eri eläinlajeilla on saatavilla rajallisesti. Oikeaa lääkeainemäärää ei voida luotettavasti ekstrapoloida toisten eläinlajien tai ihmisten perusteella. Epäillyissä tulehduskipulääkemyrkytyksissä ongelmana on tietää, oliko eläimen saama lääkeannos toksinen. Lampailla tehdyn tutkimuksen tavoitteena oli selvittää, muuttuuko ketoprofeenin kinetiikka kymmenkertaisella yliannoksella, tutkia yliannoksen vaikutusta munuaisiin ja löytää yksinkertainen tapa diagnosoida yliannos virtsasta. Sioilla tehdyn tutkimuksen tavoitteena oli selvittää ketoprofeenin biologista käytettävyyttä ja ketoprofeenin farmakokinetiikkaa sioilla intravaskulaarisella, intramuskulaarisella ja peroraalisella annolla. Keskeiset tutkimuksessa määritettävät muuttujat olivat AUC0-_, Cmax ja tmax. Hyötyosuus laskettiin i.v. -annon perusteella. Kuudelle lampaalle annettiin 30 mg/kg i.v. -ketoprofeenia. Ketoprofeenin pitoisuuksia seurattiin 24 tunnin ajan plasmanäytteillä, joiden perusteella määritettiin farmakokineettiset parametrit. Veri- ja virtsanäytteistä tutkittiin muun muassa mahdollisesta munuaisvauriosta kertovia entsyymejä. 24 tunnin kuluttua lääkkeenannosta lampaat lopetettiin ja munuaiset tutkittiin histologisesti. Tutkittaville kahdeksalle sialle annosteltiin 3 mg/kg intravaskulaarista, intramuskulaarista ja oraalista ketoprofeenia sekä 6 mg/kg oraalista ketoprofeenia. Tutkimus suoritettiin satunnaistettuna vaihtovuorotutkimuksena. Ketoprofeenin pitoisuuksia seurattiin plasmanäytteillä 48 tunnin ajan lääkkeenannosta ja kaikille antotavoille laskettiin farmakokineettiset parametrit. Lisäksi tutkittiin valmisteiden biologinen samanarvoisuus. Molempien tutkimusten in vivo -kokeet suoritettiin Eläinlääketieteellisessä tiedekunnassa. Samoin munuaisten histologinen tutkimus ja virtsasta ja verestä tehdyt määritykset, lukuun ottamatta ketoprofeeninpitoisuuden analysointia. Plasman ketoprofeenipitoisuus analysoitiin korkean erotuskyvyn nestekromatografialla (HPLC). Ketoprofeenimääritykset ja farmakokineettinen analyysi suoritettiin Farmasian tiedekunnassa. Lampaiden kymmenkertainen ketoprofeeniyliannos oli toksinen. Seerumin urea- ja kreatiniinipitoisuus nousivat ja histologisissa näytteissä näkyi akuutti munuaistiehyen vaurio. Useiden entsyymien pitoisuus nousi virtsassa. Selvimmin ja nopeimmin nousi virtsan laktaattidehydrogenaasipitoisuus, jonka määrittäminen vaikuttaa potentiaaliselta tavalta diagnosoida ketoprofeenin toksinen annos. Ketoprofeenin eliminaation puoliintumisaika toksisella annoksella oli samaa suuruusluokkaa kuin aiemmissa tutkimuksissa terapeuttisella annoksella, joten yliannos ei muuttanut ketoprofeenin kinetiikkaa. AUC- ja Cmax -arvot olivat suhteessa suurempia kuin terapeuttisella annoksella, joten tutkimuksen perusteella kyseiset arvot eivät nousseet lineaarisesti annoksen noustessa toksiseksi. Sioille annetut ketoprofeenivalmisteet eivät olleet biologisesti samanarvoisia keskenään. Hyötyosuus oli erittäin hyvä kaikilla antotavoilla. tmax oli kaikilla antotavoilla hieman yli tunnin kuluttua lääkkeenannosta. Oraalisen 3 mg/kg -annoksen Cmax oli 5,1 mg/l ja AUC 32 mg l-1 h ja intramuskulaarisen vastaavat arvot olivat 7,6 mg/l ja 37 mg l-1 h. Oraalisen ketoprofeenin annostasojen AUC- ja Cmax -arvot korreloivat keskenään, joten ketoprofeenin kinetiikka oli lineaarista. Intravaskulaarisen ja oraalisen annon puoliintumisajoissa oli tilastollisesti merkitsevä ero. Ketoprofeenin jakautumistilavuudessa ja puhdistumassa ei ollut tilastollisesti merkitsevää eroa eri antotapojen välillä.
Resumo:
Kirjallisuusosa: Alzheimerin taudin hoitoon olisi tarvetta uusille taudinkulkuun vaikuttaville lääkeaineille. Niiden kehittämiseksi tarvitaan eläinmalleja, joissa esiintyy taudin patofysiologisia piirteitä. Rottamalleista vanhemmat skopolamiini- tai MK-801-häirintä sekä ikääntyneiden rottien käyttö eivät kovin hyvin vastaa taudin patofysiologiaa, vaikka niissä eläimen muisti käyttäytymiskokeissa onkin heikentynyt. Uudemmat transgeeniset rottamallit ja mallit, joissa annetaan Aβ:a aivoihin, ilmentävät huomattavasti paremmin Alzheimerin taudin kaltaista tilaa aivoissa ainakin Aβ:n osalta. Taupatofysiologiaa ei silti kummassakaan näistä malleista juuri esiinny. Toisaalta Aβ:lla näyttäisi olevan huomattavasti tau:ta suurempi rooli taudissa, joten sen ilmeneminen mallissa onkin keskeisempi tekijä. Nämä mallit ilmentävät melko suurelti osin yhtä hyvin Alzheimerin taudin patofysiologiaa. Aβ:n antaminen on hieman yksinkertaisempi suorittaa käytännössä, sillä siinä ei tarvitse luoda transgeenista kantaa. Toisaalta transgeenisessa mallissa Aβ-patofysiologia syntyy enemmän Alzheimerin taudin kaltaisesti solujen sisällä eikä valmiita aggregoituvia Aβ-peptidejä anneta ulkopuolelta aivoihin. Molemmat mallit ovat kuitenkin käyttökelpoisia, ja soveltuvat erityisesti Aβ:an vaikuttavien lääkeaineiden kehittämiseen. Kokeellinen osa: Kokeen tarkoituksena oli validoida kohotettu ristikko-sokkelo (elevated plus-maze, EPM) hiirillä kognitiomallina. Kokeessa käytettiin kahden koekerran (trial, T) menetelmää, jossa koekertojen pituus oli viisi minuuttia. Näin saatiin useita oppimista kuvaavia parametreja. Hiirille yritettiin saada muistihäiriö aikaviiveen avulla (koekertojen väli 1-18 vrk) tai antamalla muskariinireseptoriantagonistia skopolamiinia (0,1-0,8 mg/kg i.p.) 30 minuuttia ennen T1:tä. Nämä kokeet suoritettiin sekä C57BL/6J- että ICR:(CD-1)-hiirillä. Aikaviivekokeissa ainut ryhmä, jolla oli viitettä unohtamisesta, oli ICR:(CD-1)-hiirien 18 vrk:n ryhmä. Tämän perusteella tutkittiin vielä 21 vuorokauden aikaväli, mutta selvää muistihäiriötä ei esiintynyt. Skopolamiini ei häirinnyt muistia ICR:(CD-1)-hiirillä, mutta C57BL/6J-hiirillä 0,2 mg/kg:n annoksesta ylöspäin merkitsevä muistihäiriö esiintyi. Näin ollen jatkokokeissa käytettäväksi valittiin skopolamiinin annos 0,2 mg/kg C57BL/6J-hiirillä, ja siinä tutkittiin donepetsiilin (0,3, 0,8 ja 1,5 mg/kg s.c), memantiinin (5,0 ja 10,0 mg/kg s.c) ja kokeellisen 5-HT6-antagonistin SB742457:n (1,5 ja 6,0 mg/kg s.c) muistia parantavia vaikutuksia. Tutkittavat lääkeaineet annettiin 40 minuuttia ennen T1:tä ja skopolamiini 30 minuuttia ennen. Memantiinilla (5,0 mg/kg) oli selkeä skopolamiinin heikentämää kognitiota parantava vaikutus ja donepetsiilillakin (1,5 mg/kg) suuntaus tähän. Tulosten perusteella malli näyttäisi soveltuvan muisti- ja oppimisvaikutusten tutkimiseen käytettäväksi malliksi.
Resumo:
The proportion of patients over 75 years of age, receiving all different types of healthcare, is constantly increasing. The elderly undergo surgery and anaesthetic procedures more often than middle-aged patients. Poor pain management in the elderly is still an issue. Although the elderly consumes the greatest proportion of prescribed medicines in Western Europe, most clinical pharmacological studies have been performed in healthy volunteers or middle-aged patients. The aim of this study was to investigate pain measurement and management in cognitively impaired patients in long term hospital care and in cognitively normal elderly patients after cardiac surgery. This thesis incorporated 366 patients, including 86 home-dwelling or hospitalized elderly with chronic pain and 280 patients undergoing cardiac surgery with acute pain. The mean age of patients was 77 (SD ± 8) years and approximately 8400 pain measurements were performed with four pain scales: Verbal Rating Scale (VRS), the Visual Analogue Scale (VAS), the Red Wedge Scale (RWS), and the Facial Pain Scale (FPS). Cognitive function, depression, functional ability in daily life, postoperative sedation and postoperative confusion were assessed with MMSE, GDS, Barthel Index, RASS, and CAM-ICU, respectively. The effects and plasma concentrations of fentanyl and oxycodone were measured in elderly (≥ 75 years) and middle-aged patients (≤ 60 years) and the opioid-sparing effect of pregabalin was studied after cardiac surgery. The VRS pain scores after movement correlated with the Barthel Index. The VRS was most successful in the groups of demented patients (MMSE 17-23, 11-16 and ≤ 10) and in elderly patients on the first day after cardiac surgery. The elderly had a higher plasma concentration of fentanyl at the end of surgery than younger patients. The plasma concentrations of oxycodone were comparable between the groups. Pain intensity on the VRS was lower and the sedation scores were higher in the elderly. Total oxycodone consumption during five postoperative days was reduced by 48% and the CAM-ICU scores were higher on the first postoperative day in the pregabalin group. The incidence of postoperative pain during movement was lower in the pregabalin group three months after surgery. This investigation demonstrates that chronic pain did not seem to impair daily activities in home-dwelling Finnish elderly. The VRS appeared to be applicable for elderly patients with clear cognitive dysfunction (MMSE ≤17) and it was the most feasible pain scale for the early postoperative period after cardiac surgery. After cardiac surgery, plasma concentrations of fentanyl in elderly were elevated, although oxycodone concentrations were at similar level compared to middle-aged patients. The elderly had less pain and were more sedated after doses of oxycodone. Therefore, particular attention must be given to individual dosing of the opioids in elderly surgical patients, who often need a smaller amount for adequate analgesia than middle-aged patients. The administration of pregabalin reduced postoperative oxycodone consumption after cardiac surgery. Pregabalin-treated patients had less confusion, and additionally to less postoperative pain on the first postoperative day and during movement at three months post-surgery. Pregabalin might be a new alternative as analgesic for acute postoperative and chronic pain management in the elderly. Its clinical role and safety remains to be verified in large-scale randomized and controlled studies. In the future, many clinical trials in the older category of patients will be needed to facilitate improvements in health care methods.