130 resultados para Microwave-assisted hydrothermal method


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The effect of inorganic salts on the hydrolysis of starch in a microwave field was investigated and it was found that some inorganic salts can effectively accelerate the acid hydrolysis of starch. The yield of D-glucose reached 111 wt% (equal to the theoretical yield). (C) 2001 Published by Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This article reported the NaA zeolite membranes with high permeance synthesized with microwave heating method under different conditions: (1) on a macroporous substrate in gel, (11) on a mesoporous/macroporous (top-mesoporous-layer-modified macroporous) substrate in gel, and (111) on a mesoporous/macroporous substrate in sol. In general, the H-2 permeance of the NaA membranes by microwave heating in gel was usually at the level of 10(-6) mol s(-1) m(-2) Pa-1, much higher than that by the conventional hydrothermal synthesis. At similar H-2/C3H8 permselectivity. On the substrate modified mesoporous top layer, the H-2 permeance of the NaA membranes by microwave heating in gel or sol was further enhanced, while maintaining comparable H-2/C3H8 permselectivity, due to the prevention of penetration of the reagent into the pores of the macroporous substrate. Meanwhile, the synthesis took less time in sol than in gel on the mesoporous/macroporous substrate. The NaA membranes synthesized in sol had larger permeance than those in gel and underwent transformation in shorter time. The permeation of C3H8 suggested that there existed unwanted intercrystalline pores or defects in the membranes. © 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper, cooperative self-assembly (CSA) of colloidal spheres with different sizes was studied. It was found that a complicated jamming effect makes it difficult to achieve an optimal self-assembling condition for construction of a well-ordered stacking of colloidal spheres in a relatively short growth time by CSA. Through the use of a characteristic infrared (IR) technique to significantly accelerate local evaporation on the growing interface without changing the bulk growing environment, a concise three-parameter (temperature, pressure, and IR intensity) CSA method to effectively overcome the jamming effect has been developed. Mono- and multiscale inverse opals in a large range of lattice scales can be prepared within a growth time (15-30 min) that is remarkably shorter than the growth times of several hours for previous methods. Scanning electron microscopy images and transmittance spectra demonstrated the superior crystalline and optical qualities of the resulting materials. More importantly, the new method enables optimal conditions for CSA without limitations on sizes and materials of multiple colloids. This strategy not only makes a meaningful advance in the applicability and universality of colloidal crystals and ordered porous materials but also can be an inspiration to the self-assembly systems widely used in many other fields, such as nanotechnology and molecular bioengineering.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Linear stability analysis was performed to study the mechanism of transition of thermocapillary convection in liquid bridges with liquid volume ratios ranging from 0.4 to 1.2, aspect ratio of 0.75 and Prandtl number of 100. 2-D governing equations were solved to obtain the steady axi-symmetric basic flow and temperature distributions. 3-D perturbation equations were discretized at the collocation grid points using the Chebyshev-collocation method. Eigenvalues and eigenfunctions were obtained by using the Q-R. method. The predicted critical Marangoni numbers and critical frequencies were compared with data from space experiments. The disturbance of the temperature distribution on the free surface causes the onset of oscillatory convection. It is shown that the origin of instability is related to the hydrothermal origin for convections in large-Prandtl-number liquid bridges. (C) 2007 COSPAR. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a novel method that applies pressure-assisted field-amplified sample injection with reverse migrating micelles (PA-FASI-RMM) for the online concentration of neutral analytes in MEKC with a low-pH BGE. After injection of a plug of water into the separation capillary, negative voltage and positive pressure were simultaneously applied to initialize PA-FASI-RMM injection. The hydrodynamic flow generated by the positive pressure compensated the reverse EOF in the water plug and allowed the water plug to remain in the capillary during FASI with reverse migrating micelles (FASI-RMM) to obtain a much longer injection time than usual, which improved stacking efficiency greatly. Equations describing this injection mode were introduced and were supported by experimental results. For a 450-s online PA-FASI-RMM injection, three orders of magnitude sample enhancement in terms of peak area could be observed for the steroids and an achievement of detection limits was between 1 and 10 ng/mL.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The properties of electron states in the presence of microwave irradiation play a key role in understanding the oscillations of longitudinal resistance and the zero-resistance states in a high-mobility two-dimensional electron gas(2DEG) in low magnetic field. The properties of electron states in a high-mobility and low-density GaAs/Al0.35Ga0.65As 2DEG in the presence of Ka-band microwave irradiation were studied by reflectance-based optically detected cyclotron resonance(RODCR). The influences of the direction of microwave alternating electronic field, wavelength of the laser, and temperature on RODCR results were discussed. The results show that RODCR measurements provide a convenient and powerful method for studying electron states in 2DEG.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An improved peak power method for measuring frequency responses of photodetectors in a self-heterodyne system consisting of a distributed Bragg reflector laser is proposed. The time-resolved spectrum technique is used to measure the peak power of the beat signal and the intrinsic linewidth of heat signal for calibration. The experimental results show that the impact of the thermal-induced frequency drift, which is the main reason for producing an error in measurement by conventional peak power method and spectrum power method, can be removed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The error theory of linear equation system has been applied to the calibration procedure of microwave network analyser in this article. A new explanation for the choice of the linear calibration equations is proposed and a general principle for choosing calibration equations is presented. The method can also be used to predict the occurrence of the problem of frequency limitation at some periodic frequencies. This principle is employed to the thru-short-delay (TSD) method and the solution using the chosen equations gives the most accurate results. A good agreement between the theory and the experiment has been obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We propose a scheme to generate maximally entangled states (MESs) of multiple three-level atoms in microwave cavity QED based on the resonant atom-cavity interaction. In the scheme, multiple three-level atoms initially in their ground states are sequently sent through two suitably prepared cavities. After a process of appropriate atom-cavity interaction, a subsequent measurement on the second cavity field projects the atoms onto the MESs. The practical feasibility of this method is also discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of frequency limitation arising from the calibration of asymmetric and symmetric test fixtures has been investigated. For asymmetric test fixtures, a new algorithm based on the thru-short-match (TSM) method is outlined. It is found that the conventional TSM method does not have any inherent frequency limitation, but using the same procedure with an unknown match may lead to the said problem. This limitation can be avoided by using a different algorithm. The various calibration methods for symmetric test fixtures using known standards are also discussed and the origin of the frequency limitation is identified. Several ways in avoiding the problem are proposed. There is good agreement between the theories and experimental data.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Based on the conventional through-short-match (TSM) method, an improved TSM method has been proposed in this Letter. This method gives an analytical solution and has almost all the advantages of conventional TSM methods. For example, it has no phase uncertainty and no bandwidth limitation. The experimental results show that the accuracy can be significantly improved with this method. The proposed theory can be applied to the through-open-match (TOM) method. (C) 2002 Wiley Periodicals. Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We derive the generalized rate equation for the coupled quantum-dot (QD) system irradiated by a microwave field in the presence of a quantum point contact. It is shown that when a microwave field is tuned in resonance with the energy difference between the ground states of two QD's, the photon-assisted tunneling occurs and, as a result, the coupled QD system may be used as the single qubit. Furthermore, we show that the oscillating current through the detector decays drastically as the dephasing rate increases, indicating clearly the influence of the dephasing effect induced by the quantum point contact used as a detecting device.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The problem of phase uncertainty arising in calibration of the test fixtures is investigated in this paper, It is shown that the problem exists no matter what kinds of calibration standards are used. It is also found that there is no need to determine the individual S-parameters of the test fixtures. In order to eliminate the problem of phase uncertainty, three different precise (known) reflection standards or one known reflection standard plus one known transmission standard should be used to calibrate symmetrical test fixtures. For the asymmetrical cases, three known standards, including at least one transmission standard, should be used. The thru-open-match (TOM) and thru-short-match (TSM) techniques are the simplest methods, and they have no bandwidth limitation. When the standards are imprecise (unknown), it is recommended to use any suitable technique, such as the thru-reflect-line, line-reflect-line, thru-short-delay, thru-open-delay,line-reflect-match, line-reflect-reflect-match, or multiline methods, to accurately determine the values of the required calibration terms and, in addition, to use the TOM or TSM method with the same imprecise standards to resolve the phase uncertainty.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Room-temperature microwave (MW) oscillations are observed in GaAs/AlAs (10 nm/2 nm) doped weakly coupled superlattices (SLs) in the first plateau of the I-V curve. Oscillations induced by sequential resonant tunneling are detected in a temperature range from 15 to 300 K by applying DC bias on the Si, diodes. The temperature dependence of current at small fixed bias voltage is also measured. Through analysis, it is found that the dominant transport mechanisms are sequential resonant tunneling and phonon-assisted tunneling when the temperature is below 300 K. The low bias voltage at which oscillations are realized is helpful to restrain thermionic emission through the X valley of AlAs barriers in the room-temperature transport. (C) 1999 Published by Elsevier Science B.V. All rights reserved.