An improved TM method for full two-port calibration of the asymmetric test fixtures


Autoria(s): Zhu NH; Liu C; Pun EYB; Chung PS
Data(s)

2005

Resumo

Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.

Identificador

http://ir.semi.ac.cn/handle/172111/8750

http://www.irgrid.ac.cn/handle/1471x/63905

Idioma(s)

英语

Fonte

Zhu, NH; Liu, C; Pun, EYB; Chung, PS .An improved TM method for full two-port calibration of the asymmetric test fixtures ,MICROWAVE AND OPTICAL TECHNOLOGY LETTERS,JUN 5 2005,45 (5):438-441

Palavras-Chave #光电子学 #calibration
Tipo

期刊论文