259 resultados para Electron ion collisions
Resumo:
The. total electron emission yields following the interaction of slow highly charged ions (SHCI) O4+ with different material surfaces (W, Au, Si and SiO2) have been measured. It is found that the electron emission yield gamma increases proportionally with the projectile velocity v ranging from 5.36 x 10(5)m/s to 10.7 x 10(5)m/s. The total emission yield is dependent on the target materials, and it turns out to follow the relationship gamma(Au) > gamma(Si)> gamma(W). The result shows that the electron emission yields are mainly determined by the electron stopping power of the target when the projectile potential energy is taken as a constant, which is in good agreement with the former studies
Resumo:
In order to expand the solid angle for imaging of electrons in ion-atom collisions, we designed a complex Helmholtz coils composed of four single coils. Theoretical simulations were carried out to optimize the arrangement of the coils. The complex is constructed according to the theoretical analysis, and the magnetic fields were measured for interested regions. The measured results show that the relative uniformity of the magnetic fields is +/- 0.6%, which satisfies the requirements of collision experiments.
Resumo:
The multi-electron processes are investigated for 17.9-120keV/u C1+, 30-323 keV/u C2+, 120-438 keV/u C3+, 287-480keV/u C4+ incident on a helium target. The cross-section ratios of double electron (DE) process to the total of the single electron (SE) and the double electron process (i.e. SE+DE), the direct double electron (DDI) to the direct single ionization (DSI) as well as the contributions of DDI to DE and of TI to DE are measured using coincidence techniques. The energy and charge state dependences of the measured cross-section ratios are studied and discussed.
Resumo:
The cross-section ratios of double-, triple-, quadruple-, and the total multi-electron processes to the single electron capture process sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC)) as well as the relative ratios among reaction channels in double-electron active, triple-electron active and quadruple- electron active are measured in C-13(6+) -Ne collision in the energy region of 4.15-11.08 keV/u by employing position-sensitive and time-of-flight coincident techniques. It is determined that the cross-section ratios sigma(DE)/sigma(SC), sigma(TE)/sigma(SC), sigma(QE)/sigma(SC) and sigma(ME)/sigma(SC) are approximately the constants of 0.20 +/- 0.03, 0.16 +/- 0.04, 0.06 +/- 0.02 and 0.42 +/- 0.05. These values are obviously smaller than the predictions of the molecular Coulomb over-the-barrier model (MCBM) [J. Phys. B 23 (1990) 4293], the extended classical over-the-barrier model (ECBM) [J. Phys. B 19 (1986) 2925] and the semiempirical scaling laws (SL) [Phys. Rev. A 54 (1996) 4127]. However, the relative ratios among partial processes of DE, TE and QE are found to depend on collision energy, which suggests that the collision dynamics depends on the collision velocity. The limitation of velocity-independent character of ECBM, MCBM and SL is undoubtedly shown.
Resumo:
There has been increasing demand to provide higher beam intensity and high enough beam energy for heavy ion accelerator and some other applications, which has driven electron cyclotron resonance (ECR) ion source to produce higher charge state ions with higher beam intensity. One of development trends for highly charged ECR ion source is to build new generation ECR sources by utilization of superconducting magnet technology. SECRAL (superconducting ECR ion source with advanced design in Lanzhou) was successfully built to produce intense beams of highly charged ion for Heavy Ion Research Facility in Lanzhou (HIRFL). The ion source has been optimized to be operated at 28 GHz for its maximum performance. The superconducting magnet confinement configuration of the ion source consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamping. An innovative design of SECRAL is that the three axial solenoid coils are located inside of the sextupole bore in order to reduce the interaction forces between the sextupole coils and the solenoid coils. For 28 GHz operation, the magnet assembly can produce peak mirror fields on axis of 3.6 T at injection, 2.2 T at extraction, and a radial sextupole field of 2.0 T at plasma chamber wall. During the commissioning phase at 18 GHz with a stainless steel chamber, tests with various gases and some metals have been conducted with microwave power less than 3.5 kW by two 18 GHz rf generators. It demonstrates the performance is very promising. Some record ion beam intensities have been produced, for instance, 810 e mu A of O7+, 505 e mu A of Xe20+ 306 e mu A of Xe27+, and so on. The effect of the magnetic field configuration on the ion source performance has been studied experimentally. SECRAL has been put into operation to provide highly charged ion beams for HIRFL facility since May 2007.
Resumo:
The processes of transfer ionization in He2+ -He collisions at energies ranging from 20 to 40 keV have been studied experimentally by means of cold target recoil ions momentum spectroscopy. From the longitudinal momentum spectra of recoil ions, different mechanisms of transfer ionization have been obtained. The results show that one of the electrons of helium atom being captured into the ground state of projectile ion He2+ and the other one emitted to the continuum state of projectile or target are the dominant mechanisms of transfer ionization. The autoionization cross section of projectile after two-electron capture into a double excited state is small. Transfer ionization for one target electron capture into ground state and the other one into the continuum of projectile mainly occurs at large impact parameter collisions.
Resumo:
We experimentally investigate the shell effect on the stabilization processes following the multi-electron transfer in slow collisions of Arq+-Ar (q = 6-9, It) The relative cross-section ratios of multi-electron transfer and of the subsequent stabilization with respect to single-electron capture are measured meanwhile compared with the theoretical results predicted by the classical over-barrier model. Our result indicates that the multi-electron transfer is dominant when the projectile charge is large and the subsequent stabilization shows a dramatic variation if the projectile L-shell configuration becomes open. It shows that the subsequent stabilization processes of multiply excited scattering ions have a strong dependence on the projectile shell. (C) 2010 Elsevier BV All rights reserved.
Resumo:
We report the measurements of relative cross sections for single capture (SC), double capture (DC), single ionization (SI), double ionization (DI), and transfer ionization (TI) in collisions of Xe23+ ions with helium atoms in the velocity range of 0.65-1.32 a.u. The relative cross sections show a weak velocity dependence. The cross-section ratio of double-(DE) to single-electron (SE) removal from He, sigma(DE)/sigma(SE), is about 0.45. Single capture is the dominant reaction channel which is followed by transfer ionization, while only very small probabilities are found for pure ionization and double capture. The present experimental data are in satisfactory agreement with the estimations by the extended classical over-barrier (ECB) model..
Resumo:
This paper calculates the electron impact excitation rate coefficients from the ground term 2s(2)2p(2) P-3 to the excited terms of the 2s(2)2p(2), 2s2p(3), 2s(2)2p3s, 2s(2)2p3p, and 2s(2)2p3d configurations of N II. In the calculations, rnulticonfiguration Dirac-Fork wave functions have been applied to describe the target-ion states and relativistic distorted-wave calculation has been performed to generate fine-structure collision strengths. The collision strengths are then averaged over a Maxwellian distribution of electron velocities in order to generate the effective collision strengths. The calculated rate coefficients are compared with available experimental and theoretical data, and some good agreements are found for the outer shell electron excitations. But for the inner shell electron excitations there are still some differences between the present calculations and available experiments.
Resumo:
Influence of core property on multi-electron process in the collisions of q = 6-9 and 11 isocharged sequence ions with Ne is investigated in the keV/u region The cross-section ratios of double-, triple-, quadruple- and total multi-electron processes to the single electron capture process as well as the partial ratios of different reaction channels to the relevant multi-electron process are measured by using position-sensitive and time-of-flight techniques The experimental data are compared with the theoretical predictions including the extended classical over-barrier model, the molecular Columbic barrier model and the semi-empirical scaling law Results show a core effect on multi-electron process of isocharge ions colliding with Neon, which is consistent with the results of Helium we obtained previously
New development of advanced superconducting electron cyclotron resonance ion source SECRAL (invited)
Resumo:
Superconducting electron cyclotron resonance ion source with advance design in Lanzhou (SECRAL) is an 18-28 GHz fully superconducting electron cyclotron resonance (ECR) ion source dedicated for highly charged heavy ion beam production. SECRAL, with an innovative superconducting magnet structure of solenoid-inside-sextupole and at lower frequency and lower rf power operation, may open a new way for developing compact and reliable high performance superconducting ECR ion source. One of the recent highlights achieved at SECRAL is that some new record beam currents for very high charge states were produced by 18 GHz or 18+14.5 GHz double frequency heating, such as 1 e mu A of Xe-129(43+), 22 e mu A of Bi-209(41+), and 1.5 e mu A of Bi-209(50+). To further enhance the performance of SECRAL, a 24 GHz/7 kW gyrotron microwave generator was installed and SECRAL was tested at 24 GHz. Some promising and exciting results at 24 GHz with new record highly charged ion beam intensities were produced, such as 455 e mu A of Xe-129(27+) and 152 e mu A of Xe-129(30+), although the commissioning time was limited within 3-4 weeks and rf power only 3-4 kW. Bremsstrahlung measurements at 24 GHz show that x-ray is much stronger with higher rf frequency, higher rf power. and higher minimum mirror magnetic field (minimum B). Preliminary emittance measurements indicate that SECRAL emittance at 24 GHz is slightly higher that at 18 GHz. SECRAL has been put into routine operation at 18 GHz for heavy ion research facility in Lanzhou (HIRFL) accelerator complex since May 2007. The total operation beam time from SECRAL for HIRFL accelerator has been more than 2000 h, and Xe-129(27+), Kr-78(19+), Bi-209(31+), and Ni-58(19+) beams were delivered. All of these new developments, the latest results, and long-term operation for the accelerator have again demonstrated that SECRAL is one of the best in the performance of ECR ion source for highly charged heavy ion beam production. Finally the future development of SECRAL will be presented.
Resumo:
Collision cross sections are calculated using the R-matrix method for excitations between the three lowest LS states for Na-like Cu ion. The complex resonance structures are investigated. The collision rate coefficients have been calculated assuming a Maxwellian distribution of electron-impact energies. The results of the collision cross sections are in good agreement with those of the other theory.
Resumo:
Using a refined two-dimensional hybrid-model with self-consistent microwave absorption, we have investigated the change of plasma parameters such as plasma density and ionization rate with the operating conditions. The dependence of the ion current density and ion energy and angle distribution function at the substrate surface vs. the radial position, pressure and microwave power were discussed. Results of our simulation can be compared qualitatively with many experimental measurements.
Resumo:
Ion beam etching technique was used to reveal the metallograhpic microstructure and interface morphology of electroplating chromium coating, in particular, whose substrate surface layer was treated in advance by laser quenching. Chemical etchings were, also conducted for comparison. The reveal microstructures were observed and analyzed by scanning electron microscopy. The results show that ion beam etching can reveal well the whole microstructures of composite coating-substrate materials.
Resumo:
The Ga1-xMnxSb samples were fabricated by the implantation of Mn ions into GaSb (1 0 0) substrate with mass-analyzed low-energy dual ion beam deposition system, and post-annealing. Auger electron spectroscopy depth profile of the Ga1-xMnxSb samples showed