28 resultados para sample preparation

em Helda - Digital Repository of University of Helsinki


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The growing interest for sequencing with higher throughput in the last decade has led to the development of new sequencing applications. This thesis concentrates on optimizing DNA library preparation for Illumina Genome Analyzer II sequencer. The library preparation steps that were optimized include fragmentation, PCR purification and quantification. DNA fragmentation was performed with focused sonication in different concentrations and durations. Two column based PCR purification method, gel matrix method and magnetic bead based method were compared. Quantitative PCR and gel electrophoresis in a chip were compared for DNA quantification. The magnetic bead purification was found to be the most efficient and flexible purification method. The fragmentation protocol was changed to produce longer fragments to be compatible with longer sequencing reads. Quantitative PCR correlates better with the cluster number and should thus be considered to be the default quantification method for sequencing. As a result of this study more data have been acquired from sequencing with lower costs and troubleshooting has become easier as qualification steps have been added to the protocol. New sequencing instruments and applications will create a demand for further optimizations in future.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

In this study, novel methodologies for the determination of antioxidative compounds in herbs and beverages were developed. Antioxidants are compounds that can reduce, delay or inhibit oxidative events. They are a part of the human defense system and are obtained through the diet. Antioxidants are naturally present in several types of foods, e.g. in fruits, beverages, vegetables and herbs. Antioxidants can also be added to foods during manufacturing to suppress lipid oxidation and formation of free radicals under conditions of cooking or storage and to reduce the concentration of free radicals in vivo after food ingestion. There is growing interest in natural antioxidants, and effective compounds have already been identified from antioxidant classes such as carotenoids, essential oils, flavonoids and phenolic acids. The wide variety of sample matrices and analytes presents quite a challenge for the development of analytical techniques. Growing demands have been placed on sample pretreatment. In this study, three novel extraction techniques, namely supercritical fluid extraction (SFE), pressurised hot water extraction (PHWE) and dynamic sonication-assisted extraction (DSAE) were studied. SFE was used for the extraction of lycopene from tomato skins and PHWE was used in the extraction of phenolic compounds from sage. DSAE was applied to the extraction of phenolic acids from Lamiaceae herbs. In the development of extraction methodologies, the main parameters of the extraction were studied and the recoveries were compared to those achieved by conventional extraction techniques. In addition, the stability of lycopene was also followed under different storage conditions. For the separation of the antioxidative compounds in the extracts, liquid chromatographic methods (LC) were utilised. Two novel LC techniques, namely ultra performance liquid chromatography (UPLC) and comprehensive two-dimensional liquid chromatography (LCxLC) were studied and compared with conventional high performance liquid chromatography (HPLC) for the separation of antioxidants in beverages and Lamiaceae herbs. In LCxLC, the selection of LC mode, column dimensions and flow rates were studied and optimised to obtain efficient separation of the target compounds. In addition, the separation powers of HPLC, UPLC, HPLCxHPLC and HPLCxUPLC were compared. To exploit the benefits of an integrated system, in which sample preparation and final separation are performed in a closed unit, dynamic sonication-assisted extraction was coupled on-line to a liquid chromatograph via a solid-phase trap. The increased sensitivity was utilised in the extraction of phenolic acids from Lamiaceae herbs. The results were compared to those of achieved by the LCxLC system.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Miniaturization of analytical instrumentation is attracting growing interest in response to the explosive demand for rapid, yet sensitive analytical methods and low-cost, highly automated instruments for pharmaceutical and bioanalyses and environmental monitoring. Microfabrication technology in particular, has enabled fabrication of low-cost microdevices with a high degree of integrated functions, such as sample preparation, chemical reaction, separation, and detection, on a single microchip. These miniaturized total chemical analysis systems (microTAS or lab-on-a-chip) can also be arrayed for parallel analyses in order to accelerate the sample throughput. Other motivations include reduced sample consumption and waste production as well as increased speed of analysis. One of the most promising hyphenated techniques in analytical chemistry is the combination of a microfluidic separation chip and mass spectrometer (MS). In this work, the emerging polymer microfabrication techniques, ultraviolet lithography in particular, were exploited to develop a capillary electrophoresis (CE) separation chip which incorporates a monolithically integrated electrospray ionization (ESI) emitter for efficient coupling with MS. An epoxy photoresist SU-8 was adopted as structural material and characterized with respect to its physicochemical properties relevant to chip-based CE and ESI/MS, namely surface charge, surface interactions, heat transfer, and solvent compatibility. As a result, SU-8 was found to be a favorable material to substitute for the more commonly used glass and silicon in microfluidic applications. In addition, an infrared (IR) thermography was introduced as direct, non-intrusive method to examine the heat transfer and thermal gradients during microchip-CE. The IR data was validated through numerical modeling. The analytical performance of SU-8-based microchips was established for qualitative and quantitative CE-ESI/MS analysis of small drug compounds, peptides, and proteins. The CE separation efficiency was found to be similar to that of commercial glass microchips and conventional CE systems. Typical analysis times were only 30-90 s per sample indicating feasibility for high-throughput analysis. Moreover, a mass detection limit at the low-attomole level, as low as 10E+5 molecules, was achieved utilizing MS detection. The SU-8 microchips developed in this work could also be mass produced at low cost and with nearly identical performance from chip to chip. Until this work, the attempts to combine CE separation with ESI in a chip-based system, amenable to batch fabrication and capable of high, reproducible analytical performance, have not been successful. Thus, the CE-ESI chip developed in this work is a substantial step toward lab-on-a-chip technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The feasibility of different modern analytical techniques for the mass spectrometric detection of anabolic androgenic steroids (AAS) in human urine was examined in order to enhance the prevalent analytics and to find reasonable strategies for effective sports drug testing. A comparative study of the sensitivity and specificity between gas chromatography (GC) combined with low (LRMS) and high resolution mass spectrometry (HRMS) in screening of AAS was carried out with four metabolites of methandienone. Measurements were done in selected ion monitoring mode with HRMS using a mass resolution of 5000. With HRMS the detection limits were considerably lower than with LRMS, enabling detection of steroids at low 0.2-0.5 ng/ml levels. However, also with HRMS, the biological background hampered the detection of some steroids. The applicability of liquid-phase microextraction (LPME) was studied with metabolites of fluoxymesterone, 4-chlorodehydromethyltestosterone, stanozolol and danazol. Factors affecting the extraction process were studied and a novel LPME method with in-fiber silylation was developed and validated for GC/MS analysis of the danazol metabolite. The method allowed precise, selective and sensitive analysis of the metabolite and enabled simultaneous filtration, extraction, enrichment and derivatization of the analyte from urine without any other steps in sample preparation. Liquid chromatographic/tandem mass spectrometric (LC/MS/MS) methods utilizing electrospray ionization (ESI), atmospheric pressure chemical ionization (APCI) and atmospheric pressure photoionization (APPI) were developed and applied for detection of oxandrolone and metabolites of stanozolol and 4-chlorodehydromethyltestosterone in urine. All methods exhibited high sensitivity and specificity. ESI showed, however, the best applicability, and a LC/ESI-MS/MS method for routine screening of nine 17-alkyl-substituted AAS was thus developed enabling fast and precise measurement of all analytes with detection limits below 2 ng/ml. The potential of chemometrics to resolve complex GC/MS data was demonstrated with samples prepared for AAS screening. Acquired full scan spectral data (m/z 40-700) were processed by the OSCAR algorithm (Optimization by Stepwise Constraints of Alternating Regression). The deconvolution process was able to dig out from a GC/MS run more than the double number of components as compared with the number of visible chromatographic peaks. Severely overlapping components, as well as components hidden in the chromatographic background could be isolated successfully. All studied techniques proved to be useful analytical tools to improve detection of AAS in urine. Superiority of different procedures is, however, compound-dependent and different techniques complement each other.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Many active pharmaceutical ingredients (APIs) have both anhydrate and hydrate forms. Due to the different physicochemical properties of solid forms, the changes in solid-state may result in therapeutic, pharmaceutical, legal and commercial problems. In order to obtain good solid dosage form quality and performance, there is a constant need to understand and control these phase transitions during manufacturing and storage. Thus it is important to detect and also quantify the possible transitions between the different forms. In recent years, vibrational spectroscopy has become an increasingly popular tool to characterise the solid-state forms and their phase transitions. It offers several advantages over other characterisation techniques including an ability to obtain molecular level information, minimal sample preparation, and the possibility of monitoring changes non-destructively in-line. Dehydration is the phase transition of hydrates which is frequently encountered during the dosage form production and storage. The aim of the present thesis was to investigate the dehydration behaviour of diverse pharmaceutical hydrates by near infrared (NIR), Raman and terahertz pulsed spectroscopic (TPS) monitoring together with multivariate data analysis. The goal was to reveal new perspectives for investigation of the dehydration at the molecular level. Solid-state transformations were monitored during dehydration of diverse hydrates on hot-stage. The results obtained from qualitative experiments were used to develop a method and perform the quantification of the solid-state forms during process induced dehydration in a fluidised bed dryer. Both in situ and in-line process monitoring and quantification was performed. This thesis demonstrated the utility of vibrational spectroscopy techniques and multivariate modelling to monitor and investigate dehydration behaviour in situ and during fluidised bed drying. All three spectroscopic methods proved complementary in the study of dehydration. NIR spectroscopy models could quantify the solid-state forms in the binary system, but were unable to quantify all the forms in the quaternary system. Raman spectroscopy models on the other hand could quantify all four solid-state forms that appeared upon isothermal dehydration. The speed of spectroscopic methods makes them applicable for monitoring dehydration and the quantification of multiple forms was performed during phase transition. Thus the solid-state structure information at the molecular level was directly obtained. TPS detected the intermolecular phonon modes and Raman spectroscopy detected mostly the changes in intramolecular vibrations. Both techniques revealed information about the crystal structure changes. NIR spectroscopy, on the other hand was more sensitive to water content and hydrogen bonding environment of water molecules. This study provides a basis for real time process monitoring using vibrational spectroscopy during pharmaceutical manufacturing.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The quantification and characterisation of soil phosphorus (P) is of agricultural and environmental importance and different extraction methods are widely used to asses the bioavailability of P and to characterize soil P reserves. However, the large variety of extractants, pre-treatments and sample preparation procedures complicate the comparison of published results. In order to improve our understanding of the behaviour and cycling of P in soil, it is crucial to know the scientific relevance of the methods used for various purposes. The knowledge of the factors affecting the analytical outcome is a prerequisite for justified interpretation of the results. The aim of this thesis was to study the effects of sample preparation procedures on soil P and to determine the dependence of the recovered P pool on the chemical nature of extractants. Sampling is a critical step in soil testing and sampling strategy is dependent on the land-use history and the purpose of sampling. This study revealed that pre-treatments changed soil properties and air-drying was found to affect soil P, particularly extractable organic P, by disrupting organic matter. This was evidenced by an increase in the water-extractable small-sized (<0.2 µm) P that, at least partly, took place at the expense of the large-sized (>0.2 µm) P. However, freezing induced only insignificant changes and thus, freezing can be taken to be a suitable method for storing soils from the boreal zone that naturally undergo periodic freezing. The results demonstrated that chemical nature of the extractant affects its sensitivity to detect changes in soil P solubility. Buffered extractants obscured the alterations in P solubility induced by pH changes; however, water extraction, though sensitive to physicochemical changes, can be used to reveal short term changes in soil P solubility. As for the organic P, the analysis was found to be sensitive to the sample preparation procedures: filtering may leave a large proportion of extractable organic P undetected, whereas the outcome of centrifugation was found to be affected by the ionic strength of the extractant. Widely used sequential fractionation procedures proved to be able to detect land-use -derived differences in the distribution of P among fractions of different solubilities. However, interpretation of the results from extraction experiments requires better understanding of the biogeochemical function of the recovered P fraction in the P cycle in differently managed soils under dissimilar climatic conditions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Comprehensive two-dimensional gas chromatography (GC×GC) offers enhanced separation efficiency, reliability in qualitative and quantitative analysis, capability to detect low quantities, and information on the whole sample and its components. These features are essential in the analysis of complex samples, in which the number of compounds may be large or the analytes of interest are present at trace level. This study involved the development of instrumentation, data analysis programs and methodologies for GC×GC and their application in studies on qualitative and quantitative aspects of GC×GC analysis. Environmental samples were used as model samples. Instrumental development comprised the construction of three versions of a semi-rotating cryogenic modulator in which modulation was based on two-step cryogenic trapping with continuously flowing carbon dioxide as coolant. Two-step trapping was achieved by rotating the nozzle spraying the carbon dioxide with a motor. The fastest rotation and highest modulation frequency were achieved with a permanent magnetic motor, and modulation was most accurate when the motor was controlled with a microcontroller containing a quartz crystal. Heated wire resistors were unnecessary for the desorption step when liquid carbon dioxide was used as coolant. With use of the modulators developed in this study, the narrowest peaks were 75 ms at base. Three data analysis programs were developed allowing basic, comparison and identification operations. Basic operations enabled the visualisation of two-dimensional plots and the determination of retention times, peak heights and volumes. The overlaying feature in the comparison program allowed easy comparison of 2D plots. An automated identification procedure based on mass spectra and retention parameters allowed the qualitative analysis of data obtained by GC×GC and time-of-flight mass spectrometry. In the methodological development, sample preparation (extraction and clean-up) and GC×GC methods were developed for the analysis of atmospheric aerosol and sediment samples. Dynamic sonication assisted extraction was well suited for atmospheric aerosols collected on a filter. A clean-up procedure utilising normal phase liquid chromatography with ultra violet detection worked well in the removal of aliphatic hydrocarbons from a sediment extract. GC×GC with flame ionisation detection or quadrupole mass spectrometry provided good reliability in the qualitative analysis of target analytes. However, GC×GC with time-of-flight mass spectrometry was needed in the analysis of unknowns. The automated identification procedure that was developed was efficient in the analysis of large data files, but manual search and analyst knowledge are invaluable as well. Quantitative analysis was examined in terms of calibration procedures and the effect of matrix compounds on GC×GC separation. In addition to calibration in GC×GC with summed peak areas or peak volumes, simplified area calibration based on normal GC signal can be used to quantify compounds in samples analysed by GC×GC so long as certain qualitative and quantitative prerequisites are met. In a study of the effect of matrix compounds on GC×GC separation, it was shown that quality of the separation of PAHs is not significantly disturbed by the amount of matrix and quantitativeness suffers only slightly in the presence of matrix and when the amount of target compounds is low. The benefits of GC×GC in the analysis of complex samples easily overcome some minor drawbacks of the technique. The developed instrumentation and methodologies performed well for environmental samples, but they could also be applied for other complex samples.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

During the past ten years, large-scale transcript analysis using microarrays has become a powerful tool to identify and predict functions for new genes. It allows simultaneous monitoring of the expression of thousands of genes and has become a routinely used tool in laboratories worldwide. Microarray analysis will, together with other functional genomics tools, take us closer to understanding the functions of all genes in genomes of living organisms. Flower development is a genetically regulated process which has mostly been studied in the traditional model species Arabidopsis thaliana, Antirrhinum majus and Petunia hybrida. The molecular mechanisms behind flower development in them are partly applicable in other plant systems. However, not all biological phenomena can be approached with just a few model systems. In order to understand and apply the knowledge to ecologically and economically important plants, other species also need to be studied. Sequencing of 17 000 ESTs from nine different cDNA libraries of the ornamental plant Gerbera hybrida made it possible to construct a cDNA microarray with 9000 probes. The probes of the microarray represent all different ESTs in the database. From the gerbera ESTs 20% were unique to gerbera while 373 were specific to the Asteraceae family of flowering plants. Gerbera has composite inflorescences with three different types of flowers that vary from each other morphologically. The marginal ray flowers are large, often pigmented and female, while the central disc flowers are smaller and more radially symmetrical perfect flowers. Intermediate trans flowers are similar to ray flowers but smaller in size. This feature together with the molecular tools applied to gerbera, make gerbera a unique system in comparison to the common model plants with only a single kind of flowers in their inflorescence. In the first part of this thesis, conditions for gerbera microarray analysis were optimised including experimental design, sample preparation and hybridization, as well as data analysis and verification. Moreover, in the first study, the flower and flower organ-specific genes were identified. After the reliability and reproducibility of the method were confirmed, the microarrays were utilized to investigate transcriptional differences between ray and disc flowers. This study revealed novel information about the morphological development as well as the transcriptional regulation of early stages of development in various flower types of gerbera. The most interesting finding was differential expression of MADS-box genes, suggesting the existence of flower type-specific regulatory complexes in the specification of different types of flowers. The gerbera microarray was further used to profile changes in expression during petal development. Gerbera ray flower petals are large, which makes them an ideal model to study organogenesis. Six different stages were compared and specifically analysed. Expression profiles of genes related to cell structure and growth implied that during stage two, cells divide, a process which is marked by expression of histones, cyclins and tubulins. Stage 4 was found to be a transition stage between cell division and expansion and by stage 6 cells had stopped division and instead underwent expansion. Interestingly, at the last analysed stage, stage 9, when cells did not grow any more, the highest number of upregulated genes was detected. The gerbera microarray is a fully-functioning tool for large-scale studies of flower development and correlation with real-time RT-PCR results show that it is also highly sensitive and reliable. Gene expression data presented here will be a source for gene expression mining or marker gene discovery in the future studies that will be performed in the Gerbera Laboratory. The publicly available data will also serve the plant research community world-wide.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Väärinkäytettyjen aineiden seulontaan käytetyn menetelmän tulee olla herkkä, selektiivinen, yksinkertainen, nopea ja toistettava. Työn tavoitteena oli kehittää yksinkertainen, mutta herkkä, esikäsittelymenetelmä bentsodiatsepiinien ja amfetamiinijohdannaisten kvalitatiiviseen seulomiseen virtsasta mikropilarisähkösumutussirun (μPESI) avulla, mikä tarjoaisi vaihtoehdon seulonnassa käytetyille immunologisille menetelmille, joiden herkkyys ja selektiivisyys ovat puutteellisia. Tavoitteena oli samalla tarkastella mikropilarisähkösumutussirun toimivuutta biologisten näytteiden analyysissa. Esikäsittely optimoitiin erikseen bentsodiatsepiineille ja amfetamiinijohdannaisille. Käytettyjä esikäsittelymenetelmiä olivat neste-nesteuutto, kiinteäfaasiuutto Oasis HLB-patruunalla ja ZipTip®-pipetinkärjellä sekä laimennus ja suodatus ilman uuttoa. Mittausten perusteella keskityttiin optimoimaan ZipTip®-uuttoa. Optimoinnissa tutkittavia yhdisteitä spiikattiin 0-virtsaan niiden ennaltamääritetyn raja-arvon verran, bentsodiatsepiineja 200 ng/ml ja amfetamiinijohdannaisia 300 ng/ml. Bentsodiatsepiinien kohdalla optimoitiin kutakin uuton vaihetta ja optimoinnin tuloksena näytteen pH säädettiin arvoon 5, faasi kunnostettiin asetonitriililla, tasapainotettiin ja pestiin veden (pH 5) ja asetonitriilin (10 % v/v) seoksella ja eluoitiin asetonitriilin, muurahaishapon ja veden (95:1:4 v/v/v) seoksella. Amfetamiinijohdannaisten uutossa optimoitiin näytteen ja liuottimien pH-arvoja ja tuloksena näytteen pH säädettiin arvoon 10, faasi kunnostettiin veden ja ammoniumvetykarbonaatin(pH 10, 1:1 v/v) seoksella, tasapainotettiin ja pestiin asetonitriilin ja veden (1:5 v/v) seoksella ja eluoitiin metanolilla. Optimoituja uuttoja testattiin Yhtyneet Medix Laboratorioista toimitetuilla autenttisilla virtsanäytteillä ja saatuja tuloksia verrattiin kvantitatiivisen GC/MS-analyysin tuloksiin. Bentsodiatsepiininäytteet hydrolysoitiin ennen uuttoa herkkyyden parantamiseksi. Autenttiset näytteet analysoitiin Q-TOF-laitteella Viikissä. Lisäksi hydrolysoidut bentsodiatsepiininäytteet mitattiin Yhtyneet Medix Laboratorioiden TOF-laitteella. Kehitetty menetelmä vaatii tulosten perusteella lisää optimointia toimiakseen. Ongelmana oli etenkin toistoissa ilmennyt tulosten hajonta. Manuaalista näytteensyöttöä tulisi kehittää toistettavammaksi. Autenttisten bentsodiatsepiininäytteiden analyysissa ongelmana olivat virheelliset negatiiviset tulokset ja amfetamiinijohdannaisten analyysissa virheelliset positiiviset tulokset. Virheellisiä negatiivisia tuloksia selittää menetelmän herkkyyden puute ja virheellisiä positiivisia tuloksia mittalaitteen, sirujen tai liuottimien likaantuminen.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

FTIR-spektroskopia (Fourier-muunnosinfrapunaspektroskopia) on nopea analyysimenetelmä. Fourier-laitteissa interferometrin käyttäminen mahdollistaa koko infrapunataajuusalueen mittaamisen muutamassa sekunnissa. ATR-liitännäisellä varustetun FTIR-spektrometrin käyttö ei edellytä juuri näytteen valmistusta ja siksi menetelmä on käytössä myös helppo. ATR-liitännäinen mahdollistaa myös monien erilaisten näytteiden analysoinnin. Infrapunaspektrin mittaaminen onnistuu myös sellaisista näytteistä, joille perinteisiä näytteenvalmistusmenetelmiä ei voida käyttää. FTIR-spektroskopian avulla saatu tieto yhdistetään usein tilastollisiin monimuuttuja-analyyseihin. Klusterianalyysin avulla voidaan spektreistä saatu tieto ryhmitellä samanlaisuuteen perustuen. Hierarkkisessa klusterianalyysissa objektien välinen samanlaisuus määritetään laskemalla niiden välinen etäisyys. Pääkomponenttianalyysin avulla vähennetään datan ulotteisuutta ja luodaan uusia korreloimattomia pääkomponentteja. Pääkomponenttien tulee säilyttää mahdollisimman suuri määrä alkuperäisen datan variaatiosta. FTIR-spektroskopian ja monimuuttujamenetelmien sovellusmahdollisuuksia on tutkittu paljon. Elintarviketeollisuudessa sen soveltuvuutta esimerkiksi laadun valvontaan on tutkittu. Menetelmää on käytetty myös haihtuvien öljyjen kemiallisten koostumusten tunnistukseen sekä öljykasvien kemotyyppien havaitsemiseen. Tässä tutkimuksessa arvioitiin menetelmän käyttöä suoputken uutenäytteiden luokittelussa. Tutkimuksessa suoputken eri kasvinosien uutenäytteiden FTIR-spektrejä vertailtiin valikoiduista puhdasaineista mitattuihin FTIR-spektreihin. Puhdasaineiden FTIR-spektreistä tunnistettiin niiden tyypilliset absorptiovyöhykkeet. Furanokumariinien spektrien intensiivisten vyöhykkeiden aaltolukualueet valittiin monimuuttuja-analyyseihin. Monimuuttuja-analyysit tehtiin myös IR-spektrin sormenjälkialueelta aaltolukualueelta 1785-725 cm-1. Uutenäytteitä pyrittiin luokittelemaan niiden keräyspaikan ja kumariinipitoisuuden mukaan. Keräyspaikan mukaan ryhmittymistä oli havaittavissa, mikä selittyi vyöhykkeiden aaltolukualueiden mukaan tehdyissä analyyseissa pääosin kumariinipitoisuuksilla. Näissä analyyseissa uutenäytteet pääosin ryhmittyivät ja erottuivat kokonaiskumariinipitoisuuksien mukaan. Myös aaltolukualueen 1785-725 cm-1 analyyseissa havaittiin keräyspaikan mukaan ryhmittymistä, mitä kumariinipitoisuudet eivät kuitenkaan selittäneet. Näihin ryhmittymisiin vaikuttivat mahdollisesti muiden yhdisteiden samanlaiset pitoisuudet näytteissä. Analyyseissa käytettiin myös muita aaltolukualueita, mutta tulokset eivät juuri poikenneet aiemmista. 2. kertaluvun derivaattaspektrien monimuuttuja-analyysit sormenjälkialueelta eivät myöskään muuttaneet tuloksia havaittavasti. Jatkotutkimuksissa nyt käytettyä menetelmää on mahdollista edelleen kehittää esimerkiksi tutkimalla monimuuttuja-analyyseissa 2. kertaluvun derivaattaspektreistä suppeampia, tarkkaan valittuja aaltolukualueita.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tiivistelmä ReferatAbstract Metabolomics is a rapidly growing research field that studies the response of biological systems to environmental factors, disease states and genetic modifications. It aims at measuring the complete set of endogenous metabolites, i.e. the metabolome, in a biological sample such as plasma or cells. Because metabolites are the intermediates and end products of biochemical reactions, metabolite compositions and metabolite levels in biological samples can provide a wealth of information on on-going processes in a living system. Due to the complexity of the metabolome, metabolomic analysis poses a challenge to analytical chemistry. Adequate sample preparation is critical to accurate and reproducible analysis, and the analytical techniques must have high resolution and sensitivity to allow detection of as many metabolites as possible. Furthermore, as the information contained in the metabolome is immense, the data set collected from metabolomic studies is very large. In order to extract the relevant information from such large data sets, efficient data processing and multivariate data analysis methods are needed. In the research presented in this thesis, metabolomics was used to study mechanisms of polymeric gene delivery to retinal pigment epithelial (RPE) cells. The aim of the study was to detect differences in metabolomic fingerprints between transfected cells and non-transfected controls, and thereafter to identify metabolites responsible for the discrimination. The plasmid pCMV-β was introduced into RPE cells using the vector polyethyleneimine (PEI). The samples were analyzed using high performance liquid chromatography (HPLC) and ultra performance liquid chromatography (UPLC) coupled to a triple quadrupole (QqQ) mass spectrometer (MS). The software MZmine was used for raw data processing and principal component analysis (PCA) was used in statistical data analysis. The results revealed differences in metabolomic fingerprints between transfected cells and non-transfected controls. However, reliable fingerprinting data could not be obtained because of low analysis repeatability. Therefore, no attempts were made to identify metabolites responsible for discrimination between sample groups. Repeatability and accuracy of analyses can be influenced by protocol optimization. However, in this study, optimization of analytical methods was hindered by the very small number of samples available for analysis. In conclusion, this study demonstrates that obtaining reliable fingerprinting data is technically demanding, and the protocols need to be thoroughly optimized in order to approach the goals of gaining information on mechanisms of gene delivery.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Human sport doping control analysis is a complex and challenging task for anti-doping laboratories. The List of Prohibited Substances and Methods, updated annually by World Anti-Doping Agency (WADA), consists of hundreds of chemically and pharmacologically different low and high molecular weight compounds. This poses a considerable challenge for laboratories to analyze for them all in a limited amount of time from a limited sample aliquot. The continuous expansion of the Prohibited List obliges laboratories to keep their analytical methods updated and to research new available methodologies. In this thesis, an accurate mass-based analysis employing liquid chromatography - time-of-flight mass spectrometry (LC-TOFMS) was developed and validated to improve the power of doping control analysis. New analytical methods were developed utilizing the high mass accuracy and high information content obtained by TOFMS to generate comprehensive and generic screening procedures. The suitability of LC-TOFMS for comprehensive screening was demonstrated for the first time in the field with mass accuracies better than 1 mDa. Further attention was given to generic sample preparation, an essential part of screening analysis, to rationalize the whole work flow and minimize the need for several separate sample preparation methods. Utilizing both positive and negative ionization allowed the detection of almost 200 prohibited substances. Automatic data processing produced a Microsoft Excel based report highlighting the entries fulfilling the criteria of the reverse data base search (retention time (RT), mass accuracy, isotope match). The quantitative performance of LC-TOFMS was demonstrated with morphine, codeine and their intact glucuronide conjugates. After a straightforward sample preparation the compounds were analyzed directly without the need for hydrolysis, solvent transfer, evaporation or reconstitution. The hydrophilic interaction technique (HILIC) provided good chromatographic separation, which was critical for the morphine glucuronide isomers. A wide linear range (50-5000 ng/ml) with good precision (RSD<10%) and accuracy (±10%) was obtained, showing comparable or better performance to other methods used. In-source collision-induced dissociation (ISCID) allowed confirmation analysis with three diagnostic ions with a median mass accuracy of 1.08 mDa and repeatable ion ratios fulfilling WADA s identification criteria. The suitability of LC-TOFMS for screening of high molecular weight doping agents was demonstrated with plasma volume expanders (PVE), namely dextran and hydroxyethylstarch (HES). Specificity of the assay was improved, since interfering matrix compounds were removed by size exclusion chromatography (SEC). ISCID produced three characteristic ions with an excellent mean mass accuracy of 0.82 mDa at physiological concentration levels. In summary, by combining TOFMS with a proper sample preparation and chromatographic separation, the technique can be utilized extensively in doping control laboratories for comprehensive screening of chemically different low and high molecular weight compounds, for quantification of threshold substances and even for confirmation. LC-TOFMS rationalized the work flow in doping control laboratories by simplifying the screening scheme, expediting reporting and minimizing the analysis costs. Therefore LC-TOFMS can be exploited widely in doping control, and the need for several separate analysis techniques is reduced.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tutkimuksen tarkoituksena oli selvittää desorptio/fotoionisaatio ilmanpaineessa tekniikan (engl. desorption atmospheric pressure photoionization, DAPPI) soveltuvuutta rikosteknisen laboratorion näytteiden analysointiin. DAPPI on nopea massaspektrometrinen ionisaatiotekniikka, jolla voidaan tutkia yhdisteitä suoraan erilaisilta pinnoilta. DAPPI:ssa käytetään lämmitettyä mikrosirua, joka suihkuttaa höyrystynyttä liuotin- ja kaasuvirtausta kohti näytettä. Näytteen pinnan komponentit desorboituvat lämmön vaikutuksesta, jonka jälkeen ionisoituminen tapahtuu VUV-lampun emittoimien fotonien avulla.DAPPI:lla tutkittiin takavarikoituja huumausaineita, anabolisia steroideja ja räjähdysaineita sekä niiden jäämiä erilaisilta pinnoilta. Lisäksi kartoitettiin DAPPI:n mahdollisuuksia ja rajoituksia erilaisille näytematriiseille ilman näytteiden esikäsittelyä. Takavarikoitujen huumausaineiden tutkimuksessa analysoitiin erilaisia tabletteja, jauheita, kasvirouheita, huumekasveja (khat, oopium, kannabis) ja sieniä. Anabolisia steroideja tunnistettiin tableteista sekä ampulleista, jotka sisälsivät öljymäistä nestettä. Jauheet ripoteltiin kaksipuoliselle teipille ja analysoitiin siltä. Muut näytteet analysoitiin sellaisenaan ilman minkäänlaista esikäsittelyä, paitsi nestemäisten näytteiden kohdalla näyte pipetoitiin talouspaperille, joka analysoitiin DAPPI:lla. DAPPI osoittautui nopeaksi ja yksinkertaiseksi menetelmäksi takavarikoitujen huumausaineiden ja steroidien analysoimisessa. Se soveltui hyvin rikoslaboratorion erityyppisten näytteiden rutiiniseulontaan ja helpotti erityisesti huumekasvien ja öljymäisten steroidiliuosten tutkimusta. Massaspektrometrin likaantuminen pystyttiin ehkäisemään säätämällä näytteen etäisyyttä sen suuaukosta. Likaantumista ei havaittu huolimatta näytteiden korkeista konsentraatioista ja useita kuukausia jatkuneista mittauksista. Räjähdysaineiden tutkimuksessa keskityttiin seitsemän eri räjähdysaineen DAPPI-MS-menetelmän kehitykseen; trinitrotolueeni (TNT), nitroglykoli (NK), nitroglyseriini (NG), pentriitti (PETN), heksogeeni (RDX), oktogeeni (HMX) ja pikriinihappoä Nämä orgaaniset räjähteet ovat nitraattiyhdisteitä, jotka voidaan jakaa rakenteen puolesta nitroamiineihin (RDX ja HMX), nitroaromaatteihin (TNT ja pikriinihappo) sekä nitraattiestereihin (PETN, NG ja NK). Menetelmäkehityksessä räjähdysainelaimennokset pipetoitiin polymetyylimetakrylaatin (PMMA) päälle ja analysoitiin siitä. DAPPI:lla tutkittiin myäs autenttisia räjähdysainejäämiä erilaisista matriiseista. DAPPI:lla optimoitiin jokaiselle räjähdysaineelle sopiva menetelmä ja yhdisteet saatiin näkymään puhdasaineina. Räjähdysainejäämien analysoiminen erilaisista rikospaikkamateriaaleista osoittautui haastavammaksi tehtäväksi, koska matriisit aiheuttivat itsessään korkean taustan spektriin, josta räjähdysaineiden piikit eivät useimmiten erottuneet tarpeeksi. Muut desorptioionisaatiotekniikat saattavat soveltua paremmin haastavien räjähdysainejäämien havaitsemiseksi.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Lipidit ovat rasvaliukoisia kudoksesta peräisin olevia yhdisteitä, joilla on monia eri fysiologisia tehtäviä. Lipidien analyysimenetelmien kehittämien on tärkeää, sillä niiden esiintymistä elimistössä voidaan käyttää biomarkkerina sairauksien diagnostiikassa ja apuna sairauksien kehittymismekanismien tutkimisessa. Lipideihin kuuluu polaarisuudeltaan ja rakenteeltaan hyvin erilaisia yhdisteitä. Niiden massaspektrometria-analytiikassa on aikaisemmin käytetty useita erilaisia ionisaatiomenetelmiä, jotka vaativat näytteen esikäsittelyn ennen analyysia. Desorptiosähkösumutusionisaatio-massaspektrometria (DESI-MS) ja desorptio-ilmanpainefotoionisaatio-massaspektrometria (DAPPI-MS) ovat uusia ionisaatio-menetelmiä, jotka mahdollistavat yhdisteiden analysoinnin suoraan eri matriiseista, kuten kudosnäytteistä, usein ilman esikäsittelyä. DESI-MS soveltuu parhaiten suhteellisen polaaristen yhdisteiden analytiikkaan, kun taas DAPPI:lla voidaan ionisoida myös poolittomia yhdisteitä. DESI-MS:lla on jo aikaisemmin analysoitu erilaisia lipidejä, kun taas DAPPI-MS:lla on aikaisemmin analysoitu vain steroideja. DAPPI- ja DESI-MS:lla tutkittiin erilaisten lipidien (fosfolipidit, triglyseridit, rasvahapot, rasvaliukoiset vitamiinit ja steroidit) ionisoitumista. Molemmilla menetelmillä optimoitiin standardiyhdisteille mittausolosuhteet. Lipidejä analysoitiin myös suoraan farmaseuttisista valmisteista. DAPPI:n ja DESI:n soveltuvuudessa erilaisten lipidien ionisoimiseen oli jonkin verran eroja. DAPPI toimi hyvin varsinkin poolittomampien lipidien, eli triglyseridien, steroidien, vitamiinien ja rasvahappojen ionisaatiossa, mutta huonosti hieman polaarisempien ja herkästi hajoavien fosfolipidien ionisaatiossa. Fosfolipidit fragmentoituivat DAPPI-ionisaatiossa, eikä moolimassatiedon sisältävää ionia saatu näkyviin. DESI puolestaan toimii hyvin fosfolipidien ionisoimisessa ja melko hyvin myös muiden tutkittavien lipidien ionisoimisessa, lukuunottamatta kaikkein poolittomimpia lipidejä. Uutta tietoa tutkimuksessa saatiin varsinkin DAPPI:n soveltuvuudesta erilaisten lipidien analytiikkaan. Tulosten perusteella voidaan sanoa, että DAPPI toimii yhtä hyvin tai jopa DESI:a paremmin useiden eri lipidien analytiikkassa. Menetelmää tulisi kuitenkin kehittää edelleen, jotta fosfolipidien, jotka ovat elimistön tärkeä lipidiryhmä, analysointi onnistuisi DAPPI:lla. Työssä ei analysoitu lipidejä suoraan kudosnäytteestä, joten DAPPI:n soveltuvuudesta lipidien analysointiin suoraan kudosnäytteistä ei voida tehdä johtopäätöksiä tämän työn perusteella.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Various reasons, such as ethical issues in maintaining blood resources, growing costs, and strict requirements for safe blood, have increased the pressure for efficient use of resources in blood banking. The competence of blood establishments can be characterized by their ability to predict the volume of blood collection to be able to provide cellular blood components in a timely manner as dictated by hospital demand. The stochastically varying clinical need for platelets (PLTs) sets a specific challenge for balancing supply with requests. Labour has been proven a primary cost-driver and should be managed efficiently. International comparisons of blood banking could recognize inefficiencies and allow reallocation of resources. Seventeen blood centres from 10 countries in continental Europe, Great Britain, and Scandinavia participated in this study. The centres were national institutes (5), parts of the local Red Cross organisation (5), or integrated into university hospitals (7). This study focused on the departments of blood component preparation of the centres. The data were obtained retrospectively by computerized questionnaires completed via Internet for the years 2000-2002. The data were used in four original articles (numbered I through IV) that form the basis of this thesis. Non-parametric data envelopment analysis (DEA, II-IV) was applied to evaluate and compare the relative efficiency of blood component preparation. Several models were created using different input and output combinations. The focus of comparisons was on the technical efficiency (II-III) and the labour efficiency (I, IV). An empirical cost model was tested to evaluate the cost efficiency (IV). Purchasing power parities (PPP, IV) were used to adjust the costs of the working hours and to make the costs comparable among countries. The total annual number of whole blood (WB) collections varied from 8,880 to 290,352 in the centres (I). Significant variation was also observed in the annual volume of produced red blood cells (RBCs) and PLTs. The annual number of PLTs produced by any method varied from 2,788 to 104,622 units. In 2002, 73% of all PLTs were produced by the buffy coat (BC) method, 23% by aphaeresis and 4% by the platelet-rich plasma (PRP) method. The annual discard rate of PLTs varied from 3.9% to 31%. The mean discard rate (13%) remained in the same range throughout the study period and demonstrated similar levels and variation in 2003-2004 according to a specific follow-up question (14%, range 3.8%-24%). The annual PLT discard rates were, to some extent, associated with production volumes. The mean RBC discard rate was 4.5% (range 0.2%-7.7%). Technical efficiency showed marked variation (median 60%, range 41%-100%) among the centres (II). Compared to the efficient departments, the inefficient departments used excess labour resources (and probably) production equipment to produce RBCs and PLTs. Technical efficiency tended to be higher when the (theoretical) proportion of lost WB collections (total RBC+PLT loss) from all collections was low (III). The labour efficiency varied remarkably, from 25% to 100% (median 47%) when working hours were the only input (IV). Using the estimated total costs as the input (cost efficiency) revealed an even greater variation (13%-100%) and overall lower efficiency level compared to labour only as the input. In cost efficiency only, the savings potential (observed inefficiency) was more than 50% in 10 departments, whereas labour and cost savings potentials were both more than 50% in six departments. The association between department size and efficiency (scale efficiency) could not be verified statistically in the small sample. In conclusion, international evaluation of the technical efficiency in component preparation departments revealed remarkable variation. A suboptimal combination of manpower and production output levels was the major cause of inefficiency, and the efficiency did not directly relate to production volume. Evaluation of the reasons for discarding components may offer a novel approach to study efficiency. DEA was proven applicable in analyses including various factors as inputs and outputs. This study suggests that analytical models can be developed to serve as indicators of technical efficiency and promote improvements in the management of limited resources. The work also demonstrates the importance of integrating efficiency analysis into international comparisons of blood banking.