19 resultados para NRD


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Over-expression of the c-myb gene and expression of activated forms of myb are known to transform haemopoietic cells, particularly cells of the myeloid lineage. Truncations or mutations that disrupt the negative regulatory domain (NRD) of the Myb protein confer an increased ability to transform cells. Although it has proved difficult to link mutations in c-MYB to human leukaemia, no studies investigating the presence of mutations within the c-MYB NRD have been reported. Therefore, we have performed mutational analysis of this region, using polymerase chain reaction-single-stranded conformation polymorphism and sequence analysis, in 26 patients with acute or chronic myeloid leukaemia, No mutations were detected, indicating that mutation of this region of the Myb protein is not common in the pathogenesis or progression of these diseases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Em Portugal não são conhecidos estudos publicados que identifiquem com clareza as distribuições típicas dos valores associados aos parâmetros técnicos de exposição utilizados nos exames radiológicos mais comuns. Este estudo tem como objectivos identificar os parâmetros técnicos utilizados em exames radiológicos convencionais na região de Lisboa e comparar os dados com a referência europeia CEC. Os resultados obtidos evidenciam que nas projecções estudadas existe uma predominância para o uso de termos de exposição acima da recomendação CEC e de valores de potencial da ampola (kV) abaixo da recomendação. Esta investigação sugere a necessidade de fixar os NRD nacionais, e/ou locais, e efectuar as respectivas medições, dado que a optimização da exposição é um mecanismo de controlo fundamental para limitar as exposições desnecessárias dos pacientes às radiações ionizantes. Conclui-se que a nível local (região da Grande Lisboa) existe um desconhecimento da prática radiológica enquadrada nos referenciais europeus de boa prática radiológica. Desconhecendo-se a situação a nível nacional, sugerem-se estudos no sentido de identificar os padrões de prática radiológica a nível do País e de promover a optimização dos procedimentos em radiologia convencional. ABSTRACT - Typical distribution of exposure parameters in plain radiography is unknown in Portugal. This study aims to identify exposure parameters that are being used in plain radiography in Lisbon area and to compare collected data with European references (CEC guidelines). Results show that in the four anatomic regions there is a strong tendency of using exposure times above the European recommendation. We also found that x-ray tube potential values (kV) are below the recommended values from CEC guidelines. This study shows that at a local level (Lisbon region) radiographic practice does not fit with CEC guidelines concerning exposure techniques. We suggest continuing national/local studies with the objective to improve exposure optimization and technical procedures in plain radiography. This study also suggests the need to establish national/local DRL’s and to proceed to effective measurements for exposure optimization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Actualmente a Tomografia Computorizada (TC) é um dos métodos de diagnóstico por imagem que tem uma maior contribuição para a dose de radiação X recebida pelos pacientes. Pretende-se com este estudo avaliar as doses praticadas em TC e contribuir para o estabelecimento de Níveis de Referência de Diagnóstico (NRD) na região da Grande Lisboa, Portugal. Foram efectuadas medições de dose em 5 equipamentos de TC multidetectores, considerando o abdómen como área anatómica de interesse. Recorreu-se a uma câmara de ionização e a um fantoma para obter o índice de dose de TC (CTDI) e o produto dose-comprimento (DLP), que permitem determinar os NRD. Estes valores foram comparados com os NRD propostos pela Guideline Europeia e com os estudos desenvolvidos em outros países, como o Reino Unido, Grécia e Taiwan. Os resultados revelaram que os valores de NRD obtidos neste estudo (16,7 mGy para o CTDIvol e 436,5 mGy·cm para o DLP) são discrepantes relativamente à Guideline Europeia (±50%), mas muito próximos relativamente aos NRD estabelecidos nos países considerados. Estes valores podem ser eventualmente explicados pelos equipamentos em análise e pela utilização de protocolos de exame adoptados pelos profissionais de Radiologia nas instituições analisadas. ABSTRACT - Nowadays Computed Tomography (CT) is one of the imaging techniques which have a large contribution to radiation dose received by patients. The purpose of this study is to evaluate CT doses and contribute to the establishment of Diagnostic Reference Levels (DRL) in Lisbon, Portugal. Dose measurements on 5 multidetector CT scanners have been performed, considering the abdomen as the anatomic region of interest. All measurements were performed using an ionization chamber and a phantom to obtain the index CT dose (CTDI) and the dose-length product (DLP), which are used to determine DRL. These values were compared not only with European reference dose values but also with DRL studies developed in other countries like United Kingdom, Greece and Taiwan. The results revealed that DRL values obtained in this study (CTDIvol is 16,7 mGy and DLP is 436,5 mGy·cm) have a higher discrepancy to European Guideline (±50%), while the DRL´s of other countries are nearest to values obtained in this study. Those differences may be eventually explained by the type of the evaluated equipments but also by the exam protocols used by the Radiology professionals on the analyzed institutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Níveis de exposição em exames de mamografia: 1) os NRD permitem a orientação em relação às doses a utilizar num exame radiológico específico para um doente padrão; 2) não representam um limite de dose; 3) são normalmente definidos pelo valor que engloba 75% das doses mais baixas da população alvo, para um determinado exame; 4) permitem uma triagem dos resultados observados, com o fim de evitar exposições injustificadamente altas ou baixas; 5) promover a utilização de uma pequena gama de valores que representem uma boa prática para uma imagem médica específica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Biomédica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUMO - A preocupação com os conhecimentos, atitudes, crenças e práticas, no que concerne à utilização de radiações ionizantes para fins de diagnóstico, e a sensibilização de todos os agentes envolvidos, médicos, técnicos, físicos, utentes e responsáveis pela Saúde Publica, relativamente aos níveis de radiação emitida nos exames de Tomografia Computorizada (TC), assume particular importância no domínio da Saúde Pública, na medida em que é necessário influenciar o desenvolvimento de práticas que promovam, auditem e garantam a prestação do controlo da qualidade radiológica e dosimétrica nos serviços de Radiologia a nível Nacional. Para tal, e no âmbito da publicação de estudos já realizados ao nível da União Europeia, ―Orientações Europeias dos Critérios de Qualidade para a Tomografia Computorizada (1999) ‖, é proposto estabelecer orientações na realização de estudos que permitam, numa primeira fase, estabelecer a comparação com os resultados obtidos pelos mecanismos de Controlo da Qualidade (CQ), analisar e proceder aos ajustes (se necessário) e, numa segunda fase, implementar uma moldura sistemática de avaliação periódica dos níveis de dose de radiação por exame TC e que permita a monitorização dos dados. Nesse sentido, propõe-se a realização de um Estudo Nacional que envolva a rede hospitalar pública, privada e universitária, partindo da metodologia utilizada em estudos prévios noutros países da Europa, como seja, selecção do equipamento de TC existente na Instituição Hospitalar, onde serão reunidas informações através do preenchimento de questionários relativos ao equipamento a utilizar. Serão recolhidos dados relativos ao utente, ao equipamento e parâmetros de aquisição de imagem, que permitam identificar os níveis de referência de diagnóstico (NRD) em TC, na realidade Portuguesa. Foi efectuado um estudo piloto numa instituição EPE e os valores obtidos não são significativos, nem podem assumir valor preditivo dado o reduzido tamanho da amostra. Apesar disso, sugerem a existência de parâmetros que podem ser alterados e com isso podem fazer variar a dose de radiação utilizada. ENSP/UNL Maria de Fátima Vaz de Carvalho 5 Espera-se obter com este estudo, como foi referido, a base do estabelecimento dos NRD em TC em Portugal. ----------------- ABSTRACT - The purpose of this study, in an empirical point of view, emerges from concern with the knowledge, attitudes, beliefs and practices regarding the use of ionizing radiation for diagnostic purposes and awareness of all actors involved, medical physical, technical, and responsible public health for the development of practices that promote, audited and ensure the provision of radiological quality control and dosing in radiology service at national level. In view of the complexity and characteristics involved in relation to ionizing radiation, all assume their part in protecting the physical integrity of each user and a global perspective, to ensure the safeguarding of public health, while global and globalizing factor. To this end, and in the context of the publication of studies already carried out at European Union level, "European guidelines for quality criteria for computed tomography", it is proposed to establish guidelines in conducting studies to initially establish the comparison with the results obtained by QC and make adjustments if necessary, and subsequently implement a systematic periodic assessment frame that allows monitoring of data. Accordingly, it is proposed to conduct a national study involving the public network, private and University hospitals, that extends from the methodology used in previous studies in other countries of Europe, as is, selection of equipment of existing CT in Hospital Institution, where information will be gathered by filling out questionnaires concerning the equipment to be used. Data will be collected for the wearer, equipment and parameters of image acquisition, identifying diagnostic reference levels (NRD) in CT in Portuguese fact. A pilot study was carried out in an institution EPE and the values obtained are not significant, nor can they take predictive value given the small sample size. Despite this, suggest the existence of parameters that can be changed and this can vary the dose of radiation used It is hoped to get with this study, as mentioned, the basis of the establishment of NRD in CT in Portugal.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Engenharia Biomédica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: Visando contribuir para o conhecimento das doses em tomografia computadorizada (TC), este trabalho teve o objetivo de quantificar grandezas dosimétricas associadas a exames do abdome em pacientes pediátricos, comparando-as com os níveis de referência em radiodiagnóstico (NRD). Materiais e métodos: O estudo foi realizado em dois hospitais, em um tomógrafo Toshiba Asteion single-slice e um GE BrightSpeed multi-slice. Medidas foram feitas com uma câmara de ionização tipo lápis e um objeto simulador de tronco de polimetilmetacrilato de 16 cm de diâmetro. Resultados: Os valores do índice ponderado de kerma no ar (CW) não apresentaram diferenças significativas, porém, para as grandezas índice de kerma no ar volumétrico (CVOL), produto kerma-comprimento (PKL,CT) e dose efetiva, as diferenças foram relevantes. Conclusão: Apenas o CW apresentou valores menores que os NRD, sugerindo que a otimização não seria necessária. Porém, os valores de PKL,CT e dose efetiva mostraram que há espaço para reduzir as doses de radiação pediátricas. Este trabalho ressalta a importância de avaliar todas as grandezas dosimétricas associadas aos exames por TC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nous avons étudié les relations anatomiques entre les systèmes de neurotransmission à substance P (SP) et à sérotonine (5-hydroxytryptamine, 5-HT) dans le noyau du raphé dorsal (NRD) du rongeur, afin de mieux comprendre les interactions entre ces systèmes durant la régulation de l’humeur. Le NRD reçoit une innervation SP provenant de l’habenula, et le blocage pharmacologique des récepteurs neurokinine-1 (rNK1) de la SP aurait des effets antidépresseurs. Chez le rongeur, le traitement par les antagonistes des rNK1 s’accompagne d’une désensibilisation des autorécepteurs 5-HT1A de la 5-HT et d’une hausse de l’activité des neurones 5-HT dans le NRD, suggérant des interactions locales entre ces deux systèmes. Dans un premier temps, nous avons démontré par doubles marquages immunocytochimiques en microscopies optique, confocale et électronique, la présence du rNK1 dans une sous-population de neurones 5-HT du NRD caudal. Lors de l’analyse en microscopie électronique, nous avons pu constater que les rNK1 étaient principalement cytoplasmiques dans les neurones 5-HT et membranaires sur les neurones non 5-HT du noyau. Grâce à d’autres doubles marquages, nous avons aussi pu identifier les neurones non-5-HT porteurs de rNK1 comme étant GABAergiques. Nous avons ensuite combiné l’immunomarquage de la SP avec celui du rNK1, dans le but d’examiner les relations entre les terminaisons (varicosités *) axonales SP et les neurones 5-HT (pourvus de rNK1 cytoplasmiques du NRD caudal. En simple marquage de la SP, nous avons pu estimer à 41% la fréquence avec laquelle les terminaisons SP font synapse. Dans le matériel doublement marqué pour la SP et son récepteur, les terminaisons SP ont été fréquemment retrouvées en contact direct ou à proximité des dendrites munies de rNK1 cytoplasmiques, mais toujours éloignées des dendrites à rNK1 membranaires. Pour tester l’hypothèse d’une internalisation soutenue des rNK1 par la SP dans les neurones 5-HT, nous avons ensuite examiné la localisation subcellulaire du récepteur chez le rat traité avec un antagoniste du rNK1, le RP67580. La densité du marquage des rNK1 a été mesurée dans le cytoplasme et sur la membrane des deux types de dendrites (5-HT: rNK1 cytoplasmiques; non 5-HT: rNK1 membranaires). Une heure après une injection unique de l’antagoniste, la distribution du rNK1 est apparue inchangée dans les deux types de neurones (5-HT et non 5-HT). Par contre, après un traitement quotidien de 7 ou 21 jours avec l’antagoniste, nous avons mesuré une augmentation significative des densités cytoplasmique et membranaire du rNK1 dans les neurones 5-HT, sans aucun changement dans les neurones non 5-HT. Ces traitements ont aussi augmenté l’expression du gène rNK1 dans le NRD. Enfin, nous avons mesuré une hausse de la densité membranaire du rNK1 dans les neurones 5-HT, sans hausse de densité cytoplasmique, par suite d’une lésion bilatérale de l’habenula. Ces résultats confortent l’hypothèse d’une activation et d’une internalisation soutenues des rNK1 par la SP dans les neurones 5-HT du NRD caudal. Ils suggèrent aussi que le trafic des rNK1 dans les neurones 5-HT du NRD représente un mécanisme cellulaire en contrôle de l’activation du système 5-HT par les afférences SP en provenance de l’habenula.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho tem como objectivo avaliar se os valores de dose recebida pelos doentes que realizam exames de Tomografia Computorizada (TC) Abdómen-pélvicos em dois hospitais da grande Lisboa estão de acordo com os Níveis de Referência de Diagnóstico Europeus (NRD). Foram comparadas também as unidades dosimétricas de exames realizados com corrente modelada e de exames realizados com corrente contínua em ambos os hospitais. O estudo consistiu na recolha de dados de 200 exames de TC Abdómen-pélvicos, 100 em cada hospital. No Hospital A, a média dos valores de DLPfoi 562,34 mGy.cm e a média dos valores de CTDIvol foi 12,06 mGy. No Hospital B, a média dos valores DLPe CTDIvol foi 767,14 mGy.cm e 15,02 mGy, respectivamente. No total da nossa amostra, concluiu-se que em nenhum exame os valores de unidades dosimétricas ultrapassam os valores dos NRD. Verificou-se também que os exames realizados no Hospital B implicam em média uma maior dose de radiação ionizante para o doente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este estudo teve como objetivo avaliar e comparar as doses de radiação recolhidas numa amostra de 69 pacientes, em dois hospitais, com diferentes métodos de aquisição de imagem digital, direta e indireta, que realizaram radiografia de tórax, em projeção postero-anterior (PA). Para os dois hospitais, a dose à entrada da pele (DEP) e efectiva (E), foram medidas usando o software PCXMC para comparação entre si e com referências internacionais. No Hospital A, com aquisição digital direta, a média de DEP foi de 0,089 mGy e a média de E foi 0,013 mSv. No Hospital B, com aquisição digital de indireta, a média de DEP foi de 0.151 mGy e a média de E foi 0.030mSv. Em ambos os hospitais, as doses médias não ultrapassaram os limites recomendados por lei (0,3 mGy). Para a radiografia de tórax PA, o nível de referência diagnostico (NRD) local calculado foi 0.107 mGy, para o Hospital A e 0.164 mGy, para o Hospital B. Na radiografia de tórax PA, a utilização de um sistema de aquisição direta implicou uma redução de dose de 41 %, concordante com as referências disponíveis que apontam para a redução da dose de cerca de 50 % entre os dois sistemas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Blend films (free-standing) containing 20% in volume of polyaniline (PANI) in 80% of natural rubber (NR) were fabricated by casting in three different ways: (1) adding PANI-EB (emeraldine base) dissolved in N-methyl-2-pyrrolidone (NMP) to the latex (NRL), (2) adding PANI-EB dissolved in in-cresol to NR dissolved in xylol (NRD), (3) overlaying the surface of a pure NR cast film with a PANI layer grown by in situ polymerization (NRO). All the films were immersed into HCl solution to achieve the primary doping (protonation) of PANI before the characterization. The main goal here was to investigate the elastomeric and electrical conductivity properties for each blend, which may be applied as pressure and deformation sensors in the future. The characterization was carried out by optical microscopy, dc conductivity, vibrational spectroscopy (infrared absorption and Raman scattering), thermogravimetry analysis (TGA), differential scanning calorimetry (DSC), dynamic mechanical thermal analysis (DMTA), and tensile stress-strain curves. The results suggest that the NRL blend is the most suitable in terms of mechanical and electrical properties required for applications in pressure and deformation sensors: a gain of conductivity without losing the elastomeric property of the rubber. (c) 2005 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Die vorliegende Arbeit behandelt den fluid-kristallinen Phasenübergang sowie den Glasübergang anhand von kolloidalen Hart-Kugel(HK)-Modellsystemen. Die Untersuchungen erfolgen dabei im Wesentlichen mit unterschiedlichen Lichtstreumethoden und daher im reziproken Raum. rnDie Analyse der Kristallisationskinetik zeigt, dass es bei der Kristallisation zu signifikanten Abweichungen vom Bild der klassischen Nukleationstheorie (CNT) kommt. Diese geht von einem einstufigen Nukleationsprozess aus, wohingegen bei den hier durchgeführten Experimenten ein mehrstufiger Prozess beobachtet wird. Vor der eigentlichen Kristallisation kommt es zunächst zur Nukleation einer metastabilen Zwischenphase, sogenannter Precursor. In einer zweiten Stufe erfolgt innerhalb der Precursor die eigentliche Nukleation der Kristallite. rnDurch weitere Analyse und den Vergleich des Kristallisations- und Verglasungsszenarios konnte das Konzept der Precursornukleation auf den Vorgang der Verglasung erweitert werden. Während die Kristallnukleation oberhalb des Glasübergangspunktes zum Erliegen kommt, bleibt der Prozess der Precursornukleation auch bei verglasenden Proben erhalten. Ein Glas erstarrt somit in einem amorphen Zustand mit lokalen Precursorstrukturen. Die Korrelation der gemessenen zeitlichen Entwicklung der strukturellen sowie der dynamischen Eigenschaften zeigt darüber hinaus, dass das bisher unverstandene Ageing-Phänomen von HK-Gläsern mit der Nukleation von Precursorn zusammenhängt.rnEin solches mehrstufiges Szenario wurde bereits in früheren Veröffentlichungen beobachtet. Die im Rahmen dieser Arbeit durchgeführten Messungen ermöglichten erstmals die Bestimmung von Kristallnukleationsratendichten (Kristall-NRD) und Ratendichten für die Precursornukleation bis über den Glasübergangspunkt hinaus. Die Kristall-NRD bestätigen die Resultate aus anderen experimentellen Arbeiten. Die weiteren Analysen der Kristall-NRD belegen, dass die fluid-kristalline Grenzflächenspannung bei der Nukleation entgegen den Annahmen der CNT nicht konstant ist, sondern mit ansteigendem Volumenbruch linear zunimmt. Die Erweiterung der CNT um eine linear zunehmende Grenzflächenspannung ermöglichte eine quantitative Beschreibung der gemessenen Kristall- sowie der Precursor-NRD, was den Schluss zulässt, dass es sich in beiden Fällen um einen Boltzmann-aktivierten Prozess handelt. rnUm die beobachteten Abweichungen des Nukleationsprozesses vom Bild der CNT näher zu untersuchen, wurden die kollektiven Partikeldynamiken in stabilen Fluiden und metastabilen Schmelzen analysiert. Im klassischen Bild wird angenommen, dass die kollektive Partikeldynamik beim Vorgang der Nukleation keine Rolle spielt. Anhand der Resultate zeigen sich Abweichungen in der Dynamik stabiler Fluide und metastabiler Schmelzen. Während die kollektive Partikeldynamik in der stabilen Schmelze von der Struktur entkoppelt ist, tritt oberhalb des Phasenübergangspunktes eine Kopplung von Struktur und Dynamik auf. Dabei treten die Abweichungen zunächst in der Umgebung des ersten Strukturfaktormaximums und somit bei den am stärksten besetzten Moden auf. Mit steigender Unterkühlung nehmen die Anzahl der abweichenden Moden sowie die Stärke der Abweichungen zu. Dieses Phänomen könnte einen signifikanten Einfluss auf den Nukleationsprozess und somit auf die Kristallisationskinetik haben. Die Analyse der Dynamik im stabilen Fluid zeigt darüber hinaus Hinweise auf eine Singularität bei Annäherung an den fluid-kristallinen Phasenübergangspunkt.rnDes Weiteren wurden im Rahmen der vorliegenden Arbeit erstmals Ratendichten für die heterogene Nukleation eines HK-Systems an einer flachen Wand mittels statischer Lichtstreuung (SLS) bestimmt. Die Ergebnisse der Messung zeigen, dass die Nukleationsbarriere der heterogenen Nukleation annähernd Null ist und folglich eine vollständige Benetzung der Wand mit einer kristallinen Monolage vorliegt. Die Erweiterung der Untersuchungen auf gekrümmte Oberflächen in Form von sphärischen Partikeln (Seeds) stellt die erste experimentelle Arbeit dar, die den Einfluss eines Ensembles von Seeds auf die Kristallisationskinetik in HK-Systemen untersucht. Die Kristallisationskinetik und die Mikrostruktur werden abhängig von Größe und Anzahldichte der Seed-Partikel signifikant beeinflusst. In Übereinstimmung mit konfokalmikroskopischen Experimenten und Simulationen spielt dabei das Radienverhältnis der Majoritäts- zur Minoritätskomponente eine entscheidende Rolle.