897 resultados para Agreement error


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Summary : Forensic science - both as a source of and as a remedy for error potentially leading to judicial error - has been studied empirically in this research. A comprehensive literature review, experimental tests on the influence of observational biases in fingermark comparison, and semistructured interviews with heads of forensic science laboratories/units in Switzerland and abroad were the tools used. For the literature review, some of the areas studied are: the quality of forensic science work in general, the complex interaction between science and law, and specific propositions as to error sources not directly related to the interaction between law and science. A list of potential error sources all the way from the crime scene to the writing of the report has been established as well. For the empirical tests, the ACE-V (Analysis, Comparison, Evaluation, and Verification) process of fingermark comparison was selected as an area of special interest for the study of observational biases, due to its heavy reliance on visual observation and recent cases of misidentifications. Results of the tests performed with forensic science students tend to show that decision-making stages are the most vulnerable to stimuli inducing observational biases. For the semi-structured interviews, eleven senior forensic scientists answered questions on several subjects, for example on potential and existing error sources in their work, of the limitations of what can be done with forensic science, and of the possibilities and tools to minimise errors. Training and education to augment the quality of forensic science have been discussed together with possible solutions to minimise the risk of errors in forensic science. In addition, the time that samples of physical evidence are kept has been determined as well. Results tend to show considerable agreement on most subjects among the international participants. Their opinions on possible explanations for the occurrence of such problems and the relative weight of such errors in the three stages of crime scene, laboratory, and report writing, disagree, however, with opinions widely represented in existing literature. Through the present research it was therefore possible to obtain a better view of the interaction of forensic science and judicial error to propose practical recommendations to minimise their occurrence. Résumé : Les sciences forensiques - considérés aussi bien comme source de que comme remède à l'erreur judiciaire - ont été étudiées empiriquement dans cette recherche. Une revue complète de littérature, des tests expérimentaux sur l'influence du biais de l'observation dans l'individualisation de traces digitales et des entretiens semi-directifs avec des responsables de laboratoires et unités de sciences forensiques en Suisse et à l'étranger étaient les outils utilisés. Pour la revue de littérature, quelques éléments étudies comprennent: la qualité du travail en sciences forensiques en général, l'interaction complexe entre la science et le droit, et des propositions spécifiques quant aux sources d'erreur pas directement liées à l'interaction entre droit et science. Une liste des sources potentielles d'erreur tout le long du processus de la scène de crime à la rédaction du rapport a également été établie. Pour les tests empiriques, le processus d'ACE-V (analyse, comparaison, évaluation et vérification) de l'individualisation de traces digitales a été choisi comme un sujet d'intérêt spécial pour l'étude des effets d'observation, due à son fort recours à l'observation visuelle et dû à des cas récents d'identification erronée. Les résultats des tests avec des étudiants tendent à prouver que les étapes de prise de décision sont les plus vulnérables aux stimuli induisant des biais d'observation. Pour les entretiens semi-structurés, onze forensiciens ont répondu à des questions sur des sujets variés, par exemple sur des sources potentielles et existantes d'erreur dans leur travail, des limitations de ce qui peut être fait en sciences forensiques, et des possibilités et des outils pour réduire au minimum ses erreurs. La formation et l'éducation pour augmenter la qualité des sciences forensiques ont été discutées ainsi que les solutions possibles pour réduire au minimum le risque d'erreurs en sciences forensiques. Le temps que des échantillons sont gardés a été également déterminé. En général, les résultats tendent à montrer un grand accord sur la plupart des sujets abordés pour les divers participants internationaux. Leur avis sur des explications possibles pour l'occurrence de tels problèmes et sur le poids relatif de telles erreurs dans les trois étapes scène de crime;', laboratoire et rédaction de rapports est cependant en désaccord avec les avis largement représentés dans la littérature existante. Par cette recherche il était donc possible d'obtenir une meilleure vue de l'interaction des sciences forensiques et de l'erreur judiciaire afin de proposer des recommandations pratiques pour réduire au minimum leur occurrence. Zusammenfassung : Forensische Wissenschaften - als Ursache und als Hilfsmittel gegen Fehler, die möglicherweise zu Justizirrtümern führen könnten - sind hier empirisch erforscht worden. Die eingestzten Methoden waren eine Literaturübersicht, experimentelle Tests über den Einfluss von Beobachtungseffekten (observer bias) in der Individualisierung von Fingerabdrücken und halbstandardisierte Interviews mit Verantwortlichen von kriminalistischen Labors/Diensten in der Schweiz und im Ausland. Der Literaturüberblick umfasst unter anderem: die Qualität der kriminalistischen Arbeit im Allgemeinen, die komplizierte Interaktion zwischen Wissenschaft und Recht und spezifische Fehlerquellen, welche nicht direkt auf der Interaktion von Recht und Wissenschaft beruhen. Eine Liste möglicher Fehlerquellen vom Tatort zum Rapportschreiben ist zudem erstellt worden. Für die empirischen Tests wurde der ACE-V (Analyse, Vergleich, Auswertung und Überprüfung) Prozess in der Fingerabdruck-Individualisierung als speziell interessantes Fachgebiet für die Studie von Beobachtungseffekten gewählt. Gründe sind die Wichtigkeit von visuellen Beobachtungen und kürzliche Fälle von Fehlidentifizierungen. Resultate der Tests, die mit Studenten durchgeführt wurden, neigen dazu Entscheidungsphasen als die anfälligsten für Stimuli aufzuzeigen, die Beobachtungseffekte anregen könnten. Für die halbstandardisierten Interviews beantworteten elf Forensiker Fragen über Themen wie zum Beispiel mögliche und vorhandene Fehlerquellen in ihrer Arbeit, Grenzen der forensischen Wissenschaften und Möglichkeiten und Mittel um Fehler zu verringern. Wie Training und Ausbildung die Qualität der forensischen Wissenschaften verbessern können ist zusammen mit möglichen Lösungen zur Fehlervermeidung im selben Bereich diskutiert worden. Wie lange Beweismitten aufbewahrt werden wurde auch festgehalten. Resultate neigen dazu, für die meisten Themen eine grosse Übereinstimmung zwischen den verschiedenen internationalen Teilnehmern zu zeigen. Ihre Meinungen über mögliche Erklärungen für das Auftreten solcher Probleme und des relativen Gewichts solcher Fehler in den drei Phasen Tatort, Labor und Rapportschreiben gehen jedoch mit den Meinungen, welche in der Literatur vertreten werden auseinander. Durch diese Forschungsarbeit war es folglich möglich, ein besseres Verständnis der Interaktion von forensischen Wissenschaften und Justizirrtümer zu erhalten, um somit praktische Empfehlungen vorzuschlagen, welche diese verringern. Resumen : Esta investigación ha analizado de manera empírica el rol de las ciencias forenses como fuente y como remedio de potenciales errores judiciales. La metodología empleada consistió en una revisión integral de la literatura, en una serie de experimentos sobre la influencia de los sesgos de observación en la individualización de huellas dactilares y en una serie de entrevistas semiestructuradas con jefes de laboratorios o unidades de ciencias forenses en Suiza y en el extranjero. En la revisión de la literatura, algunas de las áreas estudiadas fueron: la calidad del trabajo en ciencias forenses en general, la interacción compleja entre la ciencia y el derecho, así como otras fuentes de error no relacionadas directamente con la interacción entre derecho y ciencia. También se ha establecido una lista exhaustiva de las fuentes potenciales de error desde la llegada a la escena del crimen a la redacción del informe. En el marco de los tests empíricos, al analizar los sesgos de observación dedicamos especial interés al proceso de ACE-V (análisis, comparación, evaluación y verificación) para la individualización de huellas dactilares puesto que este reposa sobre la observación visual y ha originado varios casos recientes de identificaciones erróneas. Los resultados de las experimentaciones realizadas con estudiantes sugieren que las etapas en las que deben tornarse decisiones son las más vulnerables a lös factores que pueden generar sesgos de observación. En el contexto de las entrevistas semi-estructuradas, once científicos forenses de diversos países contestaron preguntas sobre varios temas, incluyendo las fuentes potenciales y existehtes de error en su trabajo, las limitaciones propias a las ciencias forenses, las posibilidades de reducir al mínimo los errores y las herramientas que podrían ser utilizadas para ello. Se han sugerido diversas soluciones para alcanzar este objetivo, incluyendo el entrenamiento y la educación para aumentar la calidad de las ciencias forenses. Además, se ha establecido el periodo de conservación de las muestras judiciales. Los resultados apuntan a un elevado grado de consenso entre los entrevistados en la mayoría de los temas. Sin embargo, sus opiniones sobre las posibles causas de estos errores y su importancia relativa en las tres etapas de la investigación -la escena del crimen, el laboratorio y la redacción de informe- discrepan con las que predominan ampliamente en la literatura actual. De este modo, esta investigación nos ha permitido obtener una mejor imagen de la interacción entre ciencias forenses y errores judiciales, y comenzar a formular una serie de recomendaciones prácticas para reducirlos al minimo.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background: The analysis of the Auditory Brainstem Response (ABR) is of fundamental importance to the investigation of the auditory system behaviour, though its interpretation has a subjective nature because of the manual process employed in its study and the clinical experience required for its analysis. When analysing the ABR, clinicians are often interested in the identification of ABR signal components referred to as Jewett waves. In particular, the detection and study of the time when these waves occur (i.e., the wave latency) is a practical tool for the diagnosis of disorders affecting the auditory system. Significant differences in inter-examiner results may lead to completely distinct clinical interpretations of the state of the auditory system. In this context, the aim of this research was to evaluate the inter-examiner agreement and variability in the manual classification of ABR. Methods: A total of 160 ABR data samples were collected, for four different stimulus intensity (80dBHL, 60dBHL, 40dBHL and 20dBHL), from 10 normal-hearing subjects (5 men and 5 women, from 20 to 52 years). Four examiners with expertise in the manual classification of ABR components participated in the study. The Bland-Altman statistical method was employed for the assessment of inter-examiner agreement and variability. The mean, standard deviation and error for the bias, which is the difference between examiners’ annotations, were estimated for each pair of examiners. Scatter plots and histograms were employed for data visualization and analysis. Results: In most comparisons the differences between examiner’s annotations were below 0.1 ms, which is clinically acceptable. In four cases, it was found a large error and standard deviation (>0.1 ms) that indicate the presence of outliers and thus, discrepancies between examiners. Conclusions: Our results quantify the inter-examiner agreement and variability of the manual analysis of ABR data, and they also allows for the determination of different patterns of manual ABR analysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study has been carried out to assess the importance of radiosonde corrections in improving the agreement between satellite and radiosonde measurements of upper-tropospheric humidity. Infrared [High Resolution Infrared Radiation Sounder (HIRS)-12] and microwave [Advanced Microwave Sounding Unit (AMSU)-18] measurements from the NOAA-17 satellite were used for this purpose. The agreement was assessed by comparing the satellite measurements against simulated measurements using collocated radiosonde profiles of the Atmospheric Radiation Measurement (ARM) Program undertaken at tropical and midlatitude sites. The Atmospheric Radiative Transfer Simulator (ARTS) was used to simulate the satellite radiances. The comparisons have been done under clear-sky conditions, separately for daytime and nighttime soundings. Only Vaisala RS92 radiosonde sensors were used and an empirical correction (EC) was applied to the radiosonde measurements. The EC includes correction for mean calibration bias and for solar radiation error, and it removes radiosonde bias relative to three instruments of known accuracy. For the nighttime dataset, the EC significantly reduces the bias from 0.63 to 20.10 K in AMSU-18 and from 1.26 to 0.35 K in HIRS-12. The EC has an even greater impact on the daytime dataset with a bias reduction from 2.38 to 0.28 K in AMSU-18 and from 2.51 to 0.59 K in HIRS-12. The present study promises a more accurate approach in future radiosonde-based studies in the upper troposphere.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Statistical analysis of data is crucial in cephalometric investigations. There are certainly excellent examples of good statistical practice in the field, but some articles published worldwide have carried out inappropriate analyses. Objective: The purpose of this study was to show that when the double records of each patient are traced on the same occasion, a control chart for differences between readings needs to be drawn, and limits of agreement and coefficients of repeatability must be calculated. Material and methods: Data from a well-known paper in Orthodontics were used for showing common statistical practices in cephalometric investigations and for proposing a new technique of analysis. Results: A scatter plot of the two radiograph readings and the two model readings with the respective regression lines are shown. Also, a control chart for the mean of the differences between radiograph readings was obtained and a coefficient of repeatability was calculated. Conclusions: A standard error assuming that mean differences are zero, which is referred to in Orthodontics and Facial Orthopedics as the Dahlberg error, can be calculated only for estimating precision if accuracy is already proven. When double readings are collected, limits of agreement and coefficients of repeatability must be calculated. A graph with differences of readings should be presented and outliers discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Estimates of evapotranspiration on a local scale is important information for agricultural and hydrological practices. However, equations to estimate potential evapotranspiration based only on temperature data, which are simple to use, are usually less trustworthy than the Food and Agriculture Organization (FAO)Penman-Monteith standard method. The present work describes two correction procedures for potential evapotranspiration estimates by temperature, making the results more reliable. Initially, the standard FAO-Penman-Monteith method was evaluated with a complete climatologic data set for the period between 2002 and 2006. Then temperature-based estimates by Camargo and Jensen-Haise methods have been adjusted by error autocorrelation evaluated in biweekly and monthly periods. In a second adjustment, simple linear regression was applied. The adjusted equations have been validated with climatic data available for the Year 2001. Both proposed methodologies showed good agreement with the standard method indicating that the methodology can be used for local potential evapotranspiration estimates.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Intensity modulated radiation therapy (IMRT) is a technique that delivers a highly conformal dose distribution to a target volume while attempting to maximally spare the surrounding normal tissues. IMRT is a common treatment modality used for treating head and neck (H&N) cancers, and the presence of many critical structures in this region requires accurate treatment delivery. The Radiological Physics Center (RPC) acts as both a remote and on-site quality assurance agency that credentials institutions participating in clinical trials. To date, about 30% of all IMRT participants have failed the RPC’s remote audit using the IMRT H&N phantom. The purpose of this project is to evaluate possible causes of H&N IMRT delivery errors observed by the RPC, specifically IMRT treatment plan complexity and the use of improper dosimetry data from machines that were thought to be matched but in reality were not. Eight H&N IMRT plans with a range of complexity defined by total MU (1460-3466), number of segments (54-225), and modulation complexity scores (MCS) (0.181-0.609) were created in Pinnacle v.8m. These plans were delivered to the RPC’s H&N phantom on a single Varian Clinac. One of the IMRT plans (1851 MU, 88 segments, and MCS=0.469) was equivalent to the median H&N plan from 130 previous RPC H&N phantom irradiations. This average IMRT plan was also delivered on four matched Varian Clinac machines and the dose distribution calculated using a different 6MV beam model. Radiochromic film and TLD within the phantom were used to analyze the dose profiles and absolute doses, respectively. The measured and calculated were compared to evaluate the dosimetric accuracy. All deliveries met the RPC acceptance criteria of ±7% absolute dose difference and 4 mm distance-to-agreement (DTA). Additionally, gamma index analysis was performed for all deliveries using a ±7%/4mm and ±5%/3mm criteria. Increasing the treatment plan complexity by varying the MU, number of segments, or varying the MCS resulted in no clear trend toward an increase in dosimetric error determined by the absolute dose difference, DTA, or gamma index. Varying the delivery machines as well as the beam model (use of a Clinac 6EX 6MV beam model vs. Clinac 21EX 6MV model), also did not show any clear trend towards an increased dosimetric error using the same criteria indicated above.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Uncertainty information for global leaf area index (LAI) products is important for global modeling studies but usually difficult to systematically obtain at a global scale. Here, we present a new method that cross-validates existing global LAI products and produces consistent uncertainty information. The method is based on a triple collocation error model (TCEM) that assumes errors among LAI products are not correlated. Global monthly absolute and relative uncertainties, in 0.05° spatial resolutions, were generated for MODIS, CYCLOPES, and GLOBCARBON LAI products, with reasonable agreement in terms of spatial patterns and biome types. CYCLOPES shows the lowest absolute and relative uncertainties, followed by GLOBCARBON and MODIS. Grasses, crops, shrubs, and savannas usually have lower uncertainties than forests in association with the relatively larger forest LAI. With their densely vegetated canopies, tropical regions exhibit the highest absolute uncertainties but the lowest relative uncertainties, the latter of which tend to increase with higher latitudes. The estimated uncertainties of CYCLOPES generally meet the quality requirements (± 0.5) proposed by the Global Climate Observing System (GCOS), whereas for MODIS and GLOBCARBON only non-forest biome types have met the requirement. Nevertheless, none of the products seems to be within a relative uncertainty requirements of 20%. Further independent validation and comparative studies are expected to provide a fair assessment of uncertainties derived from TCEM. Overall, the proposed TCEM is straightforward and could be automated for the systematic processing of real time remote sensing observations to provide theoretical uncertainty information for a wider range of land products.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To calculate theoretically the errors in the estimation of corneal power when using the keratometric index (nk) in eyes that underwent laser refractive surgery for the correction of myopia and to define and validate clinically an algorithm for minimizing such errors. Methods: Differences between corneal power estimation by using the classical nk and by using the Gaussian equation in eyes that underwent laser myopic refractive surgery were simulated and evaluated theoretically. Additionally, an adjusted keratometric index (nkadj) model dependent on r1c was developed for minimizing these differences. The model was validated clinically by retrospectively using the data from 32 myopic eyes [range, −1.00 to −6.00 diopters (D)] that had undergone laser in situ keratomileusis using a solid-state laser platform. The agreement between Gaussian (PGaussc) and adjusted keratometric (Pkadj) corneal powers in such eyes was evaluated. Results: It was found that overestimations of corneal power up to 3.5 D were possible for nk = 1.3375 according to our simulations. The nk value to avoid the keratometric error ranged between 1.2984 and 1.3297. The following nkadj models were obtained: nkadj= −0.0064286r1c + 1.37688 (Gullstrand eye model) and nkadj = −0.0063804r1c + 1.37806 (Le Grand). The mean difference between Pkadj and PGaussc was 0.00 D, with limits of agreement of −0.45 and +0.46 D. This difference correlated significantly with the posterior corneal radius (r = −0.94, P < 0.01). Conclusions: The use of a single nk for estimating the corneal power in eyes that underwent a laser myopic refractive surgery can lead to significant errors. These errors can be minimized by using a variable nk dependent on r1c.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A variation of low-density parity check (LDPC) error-correcting codes defined over Galois fields (GF(q)) is investigated using statistical physics. A code of this type is characterised by a sparse random parity check matrix composed of C non-zero elements per column. We examine the dependence of the code performance on the value of q, for finite and infinite C values, both in terms of the thermodynamical transition point and the practical decoding phase characterised by the existence of a unique (ferromagnetic) solution. We find different q-dependence in the cases of C = 2 and C ≥ 3; the analytical solutions are in agreement with simulation results, providing a quantitative measure to the improvement in performance obtained using non-binary alphabets.