Positional accommodative intraocular lens power error induced by the estimation of the corneal power and the effective lens position


Autoria(s): Piñero, David P.; Camps Sanchis, Vicente Jesús; Ramón, María L.; Mateo Pérez, Verónica; Pérez Cambrodí, Rafael J.
Contribuinte(s)

Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía

Grupo de Óptica y Percepción Visual (GOPV)

Data(s)

01/03/2016

01/03/2016

02/07/2015

Resumo

Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.

Identificador

Indian Journal of Ophthalmology. 2015, 63(5): 438-444. doi:10.4103/0301-4738.159882

0301-4738 (Print)

1998-3689 (Online)

http://hdl.handle.net/10045/53460

10.4103/0301-4738.159882

Idioma(s)

eng

Publicador

Wolters Kluwer - Medknow

Relação

http://dx.doi.org/10.4103/0301-4738.159882

Direitos

© Indian Journal of Ophthalmology. This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

info:eu-repo/semantics/openAccess

Palavras-Chave #Accommodating intraocular lenses #Crystalens HD #Effective lens position #Intraocular lenses power #Keratometry #Óptica
Tipo

info:eu-repo/semantics/article