Error induced by the estimation of the corneal power and the effective lens position with a rotationally asymmetric refractive multifocal intraocular lens


Autoria(s): Piñero, David P.; Camps Sanchis, Vicente Jesús; Ramón, María L.; Mateo Pérez, Verónica; Pérez Cambrodí, Rafael J.
Contribuinte(s)

Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía

Grupo de Óptica y Percepción Visual (GOPV)

Data(s)

26/06/2015

26/06/2015

18/06/2015

Resumo

AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.

Identificador

International Journal of Ophthalmology. 2015, 8(3): 501-507. doi:10.3980/j.issn.2222-3959.2015.03.12

2222-3959 (Print)

2227-4898 (Online)

http://hdl.handle.net/10045/47850

10.3980/j.issn.2222-3959.2015.03.12

Idioma(s)

eng

Publicador

IJO Press

Relação

http://dx.doi.org/10.3980/j.issn.2222-3959.2015.03.12

Direitos

© IJO Press Co., Limited

info:eu-repo/semantics/openAccess

Palavras-Chave #Mplus #Multifocal intraocular lens #Keratometry #Effective lens position #Intraocular lens power #Óptica
Tipo

info:eu-repo/semantics/article