Estimation of the Central Corneal Power in Keratoconus: Theoretical and Clinical Assessment of the Error of the Keratometric Approach


Autoria(s): Piñero, David P.; Camps Sanchis, Vicente Jesús; Caravaca Arens, Esteban; Pérez Cambrodí, Rafael J.; Artola, Alberto
Contribuinte(s)

Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía

Grupo de Óptica y Percepción Visual (GOPV)

Data(s)

04/05/2015

04/05/2015

01/03/2014

Resumo

Purpose: The aim of this study was to analyze theoretically the errors in the central corneal power calculation in eyes with keratoconus when a keratometric index (nk) is used and to clinically confirm the errors induced by this approach. Methods: Differences (DPc) between central corneal power estimation with the classical nk (Pk) and with the Gaussian equation (PGauss c ) in eyes with keratoconus were simulated and evaluated theoretically, considering the potential range of variation of the central radius of curvature of the anterior (r1c) and posterior (r2c) corneal surfaces. Further, these differences were also studied in a clinical sample including 44 keratoconic eyes (27 patients, age range: 14–73 years). The clinical agreement between Pk and PGauss c (true net power) obtained with a Scheimpflug photography–based topographer was evaluated in such eyes. Results: For nk = 1.3375, an overestimation was observed in most cases in the theoretical simulations, with DPc ranging from an underestimation of 20.1 diopters (D) (r1c = 7.9 mm and r2c = 8.2 mm) to an overestimation of 4.3 D (r1c = 4.7 mm and r2c = 3.1 mm). Clinically, Pk always overestimated the PGauss c given by the topography system in a range between 0.5 and 2.5 D (P , 0.01). The mean clinical DPc was 1.48 D, with limits of agreement of 0.71 and 2.25 D. A very strong statistically significant correlation was found between DPc and r2c (r = 20.93, P , 0.01). Conclusions: The use of a single value for nk for the calculation of corneal power is imprecise in keratoconus and can lead to significant clinical errors.

Identificador

Cornea. 2014, 33(3): 274-279. doi:10.1097/ICO.0000000000000048

0277-3740 (Print)

1536-4798 (Online)

http://hdl.handle.net/10045/46556

10.1097/ICO.0000000000000048

Idioma(s)

eng

Publicador

Lippincott, Williams & Wilkins

Relação

http://dx.doi.org/10.1097/ICO.0000000000000048

Direitos

© 2014 by Lippincott Williams & Wilkins

info:eu-repo/semantics/restrictedAccess

Palavras-Chave #Keratoconus #Corneal power #Scheimpflug photography #Keratometry #Óptica
Tipo

info:eu-repo/semantics/article