Biometry and fetal weight estimation by two-dimensional and three-dimensional ultrasonography: an intraobserver and interobserver reliability and agreement study


Autoria(s): Lima, J. C.; Miyague, A. H.; Mauad Filho, F.; Nastri, C. O.; Martins, W. P.
Contribuinte(s)

UNIVERSIDADE DE SÃO PAULO

Data(s)

06/11/2013

06/11/2013

2012

Resumo

Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.

Identificador

ULTRASOUND IN OBSTETRICS & GYNECOLOGY, HOBOKEN, v. 40, n. 2, pp. 186-193, AUG, 2012

0960-7692

http://www.producao.usp.br/handle/BDPI/42065

10.1002/uog.10146

http://dx.doi.org/10.1002/uog.10146

Idioma(s)

eng

Publicador

WILEY-BLACKWELL

HOBOKEN

Relação

ULTRASOUND IN OBSTETRICS & GYNECOLOGY

Direitos

closedAccess

Copyright WILEY-BLACKWELL

Palavras-Chave #FETAL WEIGHT #REPRODUCIBILITY OF RESULTS #ULTRASONOGRAPHY #ULTRASOUND #REPRODUCIBILITY #GUIDELINES #THICKNESS #ACOUSTICS #OBSTETRICS & GYNECOLOGY #RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Tipo

article

original article

publishedVersion