998 resultados para scales (weighing devices)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents material and gas sensing properties of Pt/SnO2 nanowires/SiC metal oxide semiconductor devices towards hydrogen. The SnO2 nanowires were deposited onto the SiC substrates by vapour-liquid-solid growth mechanism. The material properties of the sensors were investigated using scanning electron microscopy, transmission electron microscopy and X-ray photoelectron spectroscopy. The current-voltage characteristics have been analysed. The effective change in the barrier height for 1% hydrogen was found to be 142.91 meV. The dynamic response of the sensors towards hydrogen at different temperatures has also been studied. At 530°C, voltage shift of 310 mV for 1% hydrogen was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we present an investigation on Pt/graphene/GaN devices for hydrogen gas sensing applications. The graphene layer was deposited on GaN substrate using a chemical vapour deposition (CVD) technique and was characterised via Raman and X-ray photoelectron spectroscopy. The current-voltage (I-V) and dynamic response of the developed devices were investigated in forward and reverse bias operation at an optimum temperature of 160°C. Voltage shifts of 661.1 and 484.9 mV were recorded towards 1% hydrogen at forward and reverse constant bias current of 1 mA, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim To provide an overview of key governance matters relating to medical device trials and practical advice for nurses wishing to initiate or lead them. Background Medical device trials, which are formal research studies that examine the benefits and risks of therapeutic, non-drug treatment medical devices, have traditionally been the purview of physicians and scientists. The role of nurses in medical device trials historically has been as data collectors or co-ordinators rather than as principal investigators. Nurses more recently play an increasing role in initiating and leading medical device trials. Review Methods A review article of nurse-led trials of medical devices. Discussion Central to the quality and safety of all clinical trials is adherence to the International Conference on Harmonization Guidelines for Good Clinical Practice, which is the internationally-agreed standard for the ethically- and scientifically-sound design, conduct and monitoring of a medical device trial, as well as the analysis, reporting and verification of the data derived from that trial. Key considerations include the class of the medical device, type of medical device trial, regulatory status of the device, implementation of standard operating procedures, obligations of the trial sponsor, indemnity of relevant parties, scrutiny of the trial conduct, trial registration, and reporting and publication of the results. Conclusion Nurse-led trials of medical devices are demanding but rewarding research enterprises. As nursing practice and research increasingly embrace technical interventions, it is vital that nurse researchers contemplating such trials understand and implement the principles of Good Clinical Practice to protect both study participants and the research team.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background A large animal model is required for assessment of minimally invasive, tissue engineering based approaches to thoracic spine fusion, with relevance to deformity correction surgery for human adolescent idiopathic scoliosis. Here we develop a novel open mini–thoracotomy approach in an ovine model of thoracic interbody fusion which allows assessment of various fusion constructs, with a focus on novel, tissue engineering based interventions. Methods The open mini-thoracotomy surgical approach was developed through a series of mock surgeries, and then applied in a live sheep study. Customized scaffolds were manufactured to conform with intervertebral disc space clearances required of the study. Twelve male Merino sheep aged 4 to 6 years and weighing 35 – 45 kg underwent the abovementioned procedure and were divided into two groups of six sheep at survival timelines of 6 and 12 months. Each sheep underwent a 3-level discectomy (T6/7, T8/9 and T10/11) with randomly allocated implantation of a different graft substitute at each of the three levels; (i) polycaprolactone (PCL) based scaffold plus 0.54μg rhBMP-2, (ii) PCL-based scaffold alone or (iii) autograft. The sheep were closely monitored post- operatively for signs of pain (i.e. gait abnormalities/ teeth gnawing/ social isolation). Fusion assessments were conducted post-sacrifice using Computed Tomography and hard-tissue histology. All scientific work was undertaken in accordance with the study protocol has been approved by the Institute's committee on animal research. Results. All twelve sheep were successfully operated on and reached the allotted survival timelines, thereby demonstrating the feasibility of the surgical procedure and post-operative care. There were no significant complications and during the post-operative period the animals did not exhibit marked signs of distress according to the described assessment criteria. Computed Tomographic scanning demonstrated higher fusion grades in the rhBMP-2 plus PCL-based scaffold group in comparison to either PCL-based scaffold alone or autograft. These results were supported by histological evaluation of the respective groups. Conclusion. This novel open mini-thoracotomy surgical approach to the ovine thoracic spine represents a safe surgical method which can reproducibly form the platform for research into various spine tissue engineered constructs (TEC) and their fusion promoting properties.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in this thesis investigates the mathematical modelling of charge transport in electrolyte solutions, within the nanoporous structures of electrochemical devices. We compare two approaches found in the literature, by developing onedimensional transport models based on the Nernst-Planck and Maxwell-Stefan equations. The development of the Nernst-Planck equations relies on the assumption that the solution is infinitely dilute. However, this is typically not the case for the electrolyte solutions found within electrochemical devices. Furthermore, ionic concentrations much higher than those of the bulk concentrations can be obtained near the electrode/electrolyte interfaces due to the development of an electric double layer. Hence, multicomponent interactions which are neglected by the Nernst-Planck equations may become important. The Maxwell-Stefan equations account for these multicomponent interactions, and thus they should provide a more accurate representation of transport in electrolyte solutions. To allow for the effects of the electric double layer in both the Nernst-Planck and Maxwell-Stefan equations, we do not assume local electroneutrality in the solution. Instead, we model the electrostatic potential as a continuously varying function, by way of Poisson’s equation. Importantly, we show that for a ternary electrolyte solution at high interfacial concentrations, the Maxwell-Stefan equations predict behaviour that is not recovered from the Nernst-Planck equations. The main difficulty in the application of the Maxwell-Stefan equations to charge transport in electrolyte solutions is knowledge of the transport parameters. In this work, we apply molecular dynamics simulations to obtain the required diffusivities, and thus we are able to incorporate microscopic behaviour into a continuum scale model. This is important due to the small size scales we are concerned with, as we are still able to retain the computational efficiency of continuum modelling. This approach provides an avenue by which the microscopic behaviour may ultimately be incorporated into a full device-scale model. The one-dimensional Maxwell-Stefan model is extended to two dimensions, representing an important first step for developing a fully-coupled interfacial charge transport model for electrochemical devices. It allows us to begin investigation into ambipolar diffusion effects, where the motion of the ions in the electrolyte is affected by the transport of electrons in the electrode. As we do not consider modelling in the solid phase in this work, this is simulated by applying a time-varying potential to one interface of our two-dimensional computational domain, thus allowing a flow field to develop in the electrolyte. Our model facilitates the observation of the transport of ions near the electrode/electrolyte interface. For the simulations considered in this work, we show that while there is some motion in the direction parallel to the interface, the interfacial coupling is not sufficient for the ions in solution to be "dragged" along the interface for long distances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emotions play a significant role in people’s lives, including interactions with portable devices. The research aimed to understand the evolving emotional experience between people and portable interactive devices (PIDs). Activity Theory was the theoretical framework used to contextualise the research approach and findings. Two longitudinal experiments were conducted investigating emotional experiences with PIDs over six months. Experiment 1 focused on media / entertainment PIDs while Experiment 2 focused on medical / health PIDs. Mixed research methods consisting of diaries, interviews and codiscovery sessions were used to collect data. Results identified that more social interactions were experienced with media PIDs than medical PIDs. Different Task Categories, and their emotional responses, were also revealed including Features, Functional, Mediation and Auxiliary Categories. Functional and Mediation categories were characterised as overall positive while Features and Auxiliary Categories were characterised as overall negative. Further, the consequences of Negative Personal and Social interactions on the overall emotional experience were determined. For media PIDs, Negative Social experiences adversely impacted the evolving emotional experience. For medical PIDs, both Negative Social and Negative Personal experiences adversely impacted the evolving emotional experience. As a result of the findings the Designing for Evolving Emotional Experience framework was developed, outlining principles to promote positive, and avoid negative, emotional experiences with PIDs. Contributions to knowledge from the research include methodological contributions, advancing understanding of emotional experiences with PIDs, expanding the taxonomy of emotional interactions with PIDs and broadening emotion design theory and principles. The thesis concludes with an outline of implications to design research, design and related fields, future research potentials, as well as the positive contributions to designing for meaningful and enjoyable experiences in everyday life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiovascular diseases are a leading cause of death throughout the developed world. With the demand for donor hearts far exceeding the supply, a bridge-to-transplant or permanent solution is required. This is currently achieved with ventricular assist devices (VADs), which can be used to assist the left ventricle (LVAD), right ventricle (RVAD), or both ventricles simultaneously (BiVAD). Earlier generation VADs were large, volume-displacement devices designed for temporary support until a donor heart was found. The latest generation of VADs use rotary blood pump technology which improves device lifetime and the quality of life for end stage heart failure patients. VADs are connected to the heart and greater vessels of the patient through specially designed tubes called cannulae. The inflow cannulae, which supply blood to the VAD, are usually attached to the left atrium or ventricle for LVAD support, and the right atrium or ventricle for RVAD support. Few studies have characterized the haemodynamic difference between the two cannulation sites, particularly with respect to rotary RVAD support. Inflow cannulae are usually made of metal or a semi-rigid polymer to prevent collapse with negative pressures. However suction, and subsequent collapse, of the cannulated heart chamber can be a frequent occurrence, particularly with the relatively preload insensitive rotary blood pumps. Suction events may be associated with endocardial damage, pump flow stoppages and ventricular arrhythmias. While several VAD control strategies are under development, these usually rely on potentially inaccurate sensors or somewhat unreliable inferred data to estimate preload. Fixation of the inflow cannula is usually achieved through suturing the cannula, often via a felt sewing ring, to the cannulated chamber. This technique extends the time on cardiopulmonary bypass which is associated with several postoperative complications. The overall objective of this thesis was to improve the placement and design of rotary LVAD and RVAD inflow cannulae to achieve enhanced haemodynamic performance, reduced incidence of suction events, reduced levels of postoperative bleeding and a faster implantation procedure. Specific objectives were: * in-vitro evaluation of LVAD and RVAD inflow cannula placement, * design and in-vitro evaluation of a passive mechanism to reduce the potential for heart chamber suction, * design and in-vitro evaluation of a novel suture-less cannula fixation device. In order to complete in-vitro evaluation of VAD inflow cannulae, a mock circulation loop (MCL) was developed to accurately replicate the haemodynamics in the human systemic and pulmonary circulations. Validation of the MCL’s haemodynamic performance, including the form and magnitude of pressure, flow and volume traces was completed through comparisons of patient data and the literature. The MCL was capable of reproducing almost any healthy or pathological condition, and provided a useful tool to evaluate VAD cannulation and other cardiovascular devices. The MCL was used to evaluate inflow cannula placement for rotary VAD support. Left and right atrial and ventricular cannulation sites were evaluated under conditions of mild and severe heart failure. With a view to long term LVAD support in the severe left heart failure condition, left ventricular inflow cannulation was preferred due to improved LVAD efficiency and reduced potential for thrombus formation. In the mild left heart failure condition, left atrial cannulation was preferred to provide an improved platform for myocardial recovery. Similar trends were observed with RVAD support, however to a lesser degree due to a smaller difference in right atrial and ventricular pressures. A compliant inflow cannula to prevent suction events was then developed and evaluated in the MCL. As rotary LVAD or RVAD preload was reduced, suction events occurred in all instances with a rigid inflow cannula. Addition of the compliant segment eliminated suction events in all instances. This was due to passive restriction of the compliant segment as preload dropped, thus increasing the VAD circuit resistance and decreasing the VAD flow rate. Therefore, the compliant inflow cannula acted as a passive flow control / anti-suction system in LVAD and RVAD support. A novel suture-less inflow cannula fixation device was then developed to reduce implantation time and postoperative bleeding. The fixation device was evaluated for LVAD and RVAD support in cadaveric animal and human hearts attached to a MCL. LVAD inflow cannulation was achieved in under two minutes with the suture-less fixation device. No leakage through the suture-less fixation device – myocardial interface was noted. Continued development and in-vivo evaluation of this device may result in an improved inflow cannulation technique with the potential for off-bypass insertion. Continued development of this research, in particular the compliant inflow cannula and suture-less inflow cannulation device, will result in improved postoperative outcomes, life span and quality of life for end-stage heart failure patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Achenbach child behaviour checklist (CBCL/YSR) is a widely used screening tool for affective problems. Several studies report good association between the checklists and psychiatric diagnoses; although with varying degrees of agreement. Most are cross-sectional studies involving adolescents referred to mental health services. This paper aims to evaluate the performance of the youth self report (YSR) empirical and DSM-oriented internalising scales in predicting later depressive disorders in young adults. Methods Sample was 2431 young adults from an Australian birth cohort study. The strength of association between the empirical and DSM-oriented scales assessed at 14 and 21 years and structured-interview derived depression in young adulthood (18 to 22 years) were tested using odds ratios, ROC analyses and related diagnostic efficiency tests (sensitivity, specificity, positive and negative predictive values). Results Adolescents with internalising symptoms were twice (OR 2.3, 95%CI 1.7 to 3.1) as likely to be diagnosed with DSM-IV depression by age 21. Use of DSM-oriented depressive scales did not improve the concordance between the internalising behaviour and DSM-IV diagnosed depression at age 14 (ORs ranged from 1.9 to 2.5). Limitations Some loss to follow-up over the 7-year gap between the two waves of follow-up. Conclusion DSM-oriented scales perform no better than the standard internalising or anxious/depressed scales in identifying young adults with later DSM-IV depressive disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background The Achenbach problem behaviour scales (CBCL/YSR) are widely used. The DSM-oriented anxiety and depression scales have been created to improve concordance between Achenbach’s internalising scales and DSM-IV depression and anxiety. To date no study has examined the concurrent utility of the young adult (YASR) internalising scales, either the empirical or newly developed DSM-oriented depressive or anxiety scales. Methods A sample of 2,551 young adults, aged 18–23 years, from an Australian cohort study. The association between the empirical and DSM-oriented anxiety and depression scales were individually assessed against DSMIV depression and anxiety diagnoses derived from structured interview. Odds ratios, ROC analyses and diagnostic efficiency tests (sensitivity, specificity, positive and negative predictive values) were used to report findings. Results YASR empirical internalising scale predicted DSM-IV mood disorders (depression OR = 6.9, 95% CI 5.0–9.5; anxiety OR = 5.1, 95% CI 3.8–6.7) in the previous 12 months. DSM-oriented depressive or anxiety scales did not appear to improve the concordance with DSM-IV diagnosed depression or anxiety. The internalising scales were much more effective at identifying those with comorbid depression and anxiety, with Ors between 10.1 and 21.7 depending on the internalising scale used. Conclusion DSM-oriented scales perform no better than the standard internalising in identifying young adults with DSM-IV mood or anxiety disorder.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The invention relates to a method for monitoring user activity on a mobile device, comprising an input and an output unit, comprising the following steps preferably in the following order: detecting and / or logging user activity on said input unit, identifying a foreground running application, hashing of a user-interface-element management list of the foreground running application, and creating a screenshot comprising items displayed on said input unit. The invention also relates to a method for analyzing user activity at a server, comprising the following step: obtaining at least one of an information about detected and / or logged user activity, an information about a foreground running application, a hashed user-interface-element management list and a screenshot from a mobile device. Further, a computer program product is provided, comprising one or more computer readable media having computer executable instructions for performing the steps of at least one of the aforementioned methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a risk model for estimating the likelihood of collisions at low-exposure railway level crossings, demonstrating the effect that differences in safety integrity can have on the likelihood of a collision. The model facilitates the comparison of safety benefits between level crossings with passive controls (stop or give-way signs) and level crossings that have been hypothetically upgraded with conventional or low-cost warning devices. The scenario presented illustrates how treatment of a cross-section of level crossings with low cost devices can provide a greater safety benefit compared to treatment with conventional warning devices for the same budget.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter closure of patent foramen ovale (PFO) has rapidly evolved as the preferred management strategy for the prevention of recurrent cerebrovascular events in patients with cryptogenic stroke and presumed paradoxical embolus. There is limited outcome data in patients treated with this therapy particularly for the newer devices. METHODS: Data from medical records, catheter, and echocardiography databases on 70 PFO procedures performed was collected prospectively. RESULTS: The cohort consisted of 70 patients (mean age 43.6 years, range 19 to 77 years), of whom 51% were male. The indications for closure were cryptogenic cerebrovascular accident (CVA) or transient ischemic attack (TIA) in 64 (91%) and peripheral emboli in two (2.8%) patients and cryptogenic ST-elevation myocardial infarction in one (1.4%), refractory migraine in one (1.4%), decompression sickness in one (1.4%), and orthodeoxia in one (1.4%) patient, respectively. All patients had demonstrated right-to-left shunting on bubble study. The procedures were guided by intracardiac echocardiography in 53%, transesophageal echocardiography in 39%, and the remainder by transthoracic echo alone. Devices used were the Amplatzer PFO Occluder (AGA Medical) (sizes 18-35 mm) in 49 (70%) and the Premere device (St. Jude Medical) in 21 (30%). In-hospital complications consisted of one significant groin hematoma with skin infection. Echocardiographic follow-up at 6 months revealed that most patients had no or trivial residual shunt (98.6%), while one patient (1.4%) had a mild residual shunt. At a median of 11 months' follow-up (range 1 month to 4.3 years), no patients (0%) experienced further CVA/TIAs or paradoxical embolic events during follow-up. CONCLUSION: PFO causing presumed paradoxical embolism can be closed percutaneously with a low rate of significant residual shunting and very few complications. Recurrent index events are uncommon at medium-term (up to 4 years) follow-up.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This practice-led project has two outcomes: a collection of short stories titled 'Corkscrew Section', and an exegesis. The short stories combine written narrative with visual elements such as images and typographic devices, while the exegesis analyses the function of these graphic devices within adult literary fiction. My creative writing explores a variety of genres and literary styles, but almost all of the stories are concerned with fusing verbal and visual modes of communication. The exegesis adopts the interpretive paradigm of multimodal stylistics, which aims to analyse graphic devices with the same level of detail as linguistic analysis. Within this framework, the exegesis compares and extends previous studies to develop a systematic method for analysing how the interactions between language, images and typography create meaning within multimodal literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two longitudinal experiments were conducted exploring emotional experiences with PIDs over six months including media and medial Portable Interactive Devices (PIDs). Results identifying the impact of negative social and personal interactions on the overall emotional experience as well as different task categories (Features, Functional, Mediation and Auxiliary) and their corresponding emotional responses have previously been reported [2,3,4,5]. This paper builds on these findings and presents the Designing for Evolving Emotional Experience (DE3) framework promoting positive (and deals with negative) emotional experiences with PIDs including a set of principles to better understand emotional experiences. To validate the DE3 framework a preliminary trial was conducted with five practicing industrial designers. The trial required them to consider initial design concepts using the DE3 framework followed by a questionnaire asking about their use of the framework for concept development. The trial aimed to analyse the effectiveness, efficiency and usefulness of the framework in assisting in the development of initial concepts for PIDs taking into account emotional experiences. Common themes regarding the framework are outlined including the ease of use, the effectiveness in focusing on the personal and social contexts and positive ratings regarding its use. Overall the feedback from the preliminary trial was encouraging with responses suggesting that the framework was accessible, rated highly and most importantly permitted designers to consider emotional experiences during concept development. The paper concludes with a discussion regarding the future development of the DE3 framework and the potential implications to design theory and the design discipline.