997 resultados para measurement database


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCCIÓN. La mediastinitis posterior a cirugía de revascularización miocárdica es una infección infrecuente, pero potencialmente fatal. En la Fundación Cardioinfantil se ha observado una tendencia al incremento de la misma en los últimos años, obligando a un cambio en las medidas de profilaxis antimicrobiana, pasando de cefalosporinas a vancomicina – gentamicina, sin embargo no se conoce aún el impacto de estas medidas. OBJETIVO: Determinar si el cambio de la profilaxis antibiótica en pacientes sometidos a revascularización miocárdica influye en una disminución de la incidencia de mediastinitis durante los años 2012 – 2013. METODOLOGÍA: Estudio de cohortes retrospectivo, evaluando la incidencia de mediastinitis post revascularización miocárdica, en pacientes expuestos a 2 diferentes tipos de profilaxis antimicrobiana (cefalosporinas vs vancomicina-gentamicina). Se describieron los patrones de susceptibilidad y resistencia de los patógenos encontrados en mediastinitis y la mortalidad de esta patología. RESULTADOS: Los patógenos más frecuentemente aislados en la mediastinitis fueron Staphylococcus aureus y Klebsiella pneumoniae, en la mayoría monomicrobiano. Se encontraron patógenos con perfiles de resistencia como betalactamasas de espectro extendido en Gram negativos y resistencia a la meticilina en cocos Gram positivos. El RR de mediastinitis del grupo expuesto a vancomicina-gentamicina respecto al grupo de cefalosporinas fue de 0,9 con IC 95% 0,28 – 3,28. CONCLUSIÓN: la epidemiologia microbiana de la mediastinitis no difiere de la reportada en otras series. La profilaxis antimicrobiana con vancomicina - gentamicina en pacientes sometidos a revascularización miocárdica, no redujo la incidencia de mediastinitis. Se propone regresar a la terapia de profilaxis con cefalosporinas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción: el lupus eritematoso sistémico (LES) es considerado una enfermedad de alto costo. La expresión clínica de la enfermedad depende de la ubicación geografía y la etnicidad. El objetivo de este estudio fue el calcular los costos ambulatorios relacionado al LES en una cohorte colombiana, identificar los predictores de costos y comparar nuestro resultados con otras poblaciones. Métodos: Se realizó una aproximación de tipo prevalencia en 100 pacientes LES en quienes se evaluaron los costos directos médicos, directos no médicos, indirectos e intangibles. Todos los costos médicos fueron evaluados usando una metodología abajo hacia arriba. Los costos directos fueron valorados desde una perspectiva social usando una metodología de micro-costeo. Los costos indirectos se evaluaron mediante una aproximación de capital humano, y los costos intangibles calculados a partir de los años de vida ajustados por calidad (AVAC). Se analizaron los datos por medio de un análisis multivariado. Para comparaciones con otras poblaciones todos los costos fueron expresados como la razón entre los costos y producto interno bruto nacional per cápita. Resultados: La media de costos totales fue 13.031±9.215 USD (ajustados por el factor de conversión de paridad del poder adquisitivo), lo cual representa el 1,66 del PIB per capita de Colombia. Los costos directos son el 64% de los costos totales. Los costos médicos representan el 80% de los costos directos,. Los costos indirectos fueron el 10% y los costos intangibles el 25% de los costos totales. Los medicamentos representaron el 45% de los costos directos. Mayores costos se relacionaron con el estrato socioeconómico, seguro médico privado, AVAC, alopecia, micofenolato mofetilo, y terapia anticoagulante. Los costos directos ajustados de los pacientes con LES en Colombia fueron mayores que en Norte América y en Europa. Conclusiones: el LES impone una carga económica importante para la sociedad. Los costos relacionados con la atención médica y AVAC fueron los principales contribuyentes al alto costo de la enfermedad. Estos resultados pueden ser referencia para determinar políticas en salud pública así como comparar el gasto en salud de forma internacional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Examina la relación entre los niveles de actividad física (AF) de forma objetiva, la condición física (CF) y el tiempo de exposición a pantallas en niños y adolescentes de Bogotá, Colombia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCCION La hipotensión arterial por anestesia raquídea en embarazadas llevadas a cesárea es frecuente y deletérea para la madre y el feto, sin que a la fecha exista una herramienta clínicamente útil para predecirla. La variabilidad de la frecuencia cardiaca es una medida que estima la actividad del sistema nervioso autónomo y algunos estudio iniciales indican una posible utilidad como herramienta predictiva de hipotensión arterial en esta población. METODOLOGIA Se realizó un estudio observacional descriptivo para examinar el comportamiento de la variabilidad de la frecuencia cardiaca, medida como razón de Baja frecuencia/Alta frecuencia, con un punto de corte de 2.5 tomada con un reloj POLAR RS800CX, en una población de pacientes con embarazo a término llevadas a cesárea, en un hospital de tercer nivel en Bogotá- Colombia entre Febrero y Abril del 2015. RESULTADOS El estudio incluyó 82 pacientes. Se determinó que la razón Baja frecuencia/Alta frecuencia mayor a 2,5 era poco frecuente en nuestra población (15.85%), y su asociación no fue significativa. DISCUSION El presente estudio demostró que la asociación entre la presencia de hipotensión y un índice Baja frecuencia/Alta frecuencia con punto de corte de 2.5 no es significativo para nuestra población de mujeres con embarazo a término llevadas a cesárea con anestesia espinal. Según los resultados se sugieres un punto de corte de 1.6 como punto de partida para la realización de nuevos estudios que permitan validar este valor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is mainly a discussant paper on measurement criteria upon sector’s investment and capitalservices and the way these composition and measurement issues come to have an impact ongrowth figures for some major sectors of the Colombian economy. The main focus is on distinctionmatters regarding the measurement of capital stock and capital services in the productionprocess. The availability of appropriate data, widely discussed throughout the document, impliesthat major affirmations are more hypothetic than indicative or descriptive in style. Moststatements are established as a motivation device for studies on sector’s activities with a focus onconsistency with aggregate figures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducción. En Colombia, el 80% de los pacientes con enfermedad renal crónica en hemodiálisis tienen fístula arteriovenosa periférica (FAV) que asegura el flujo de sangre durante la hemodiálisis (1), la variabilidad en el flujo de sangre en el brazo de la FAV hacia la parte distal, puede afectar la lectura de la oximetría de pulso (SpO2) (2), llevando a la toma de decisiones equivocadas por el personal de salud. El objetivo de este estudio es aclarar si existe diferencia entre la SpO2 del brazo de la FAV y el brazo contralateral. Materiales y métodos. Se realizó un estudio de correlación entre los valores de SpO2 del brazo con FAV contra el brazo sin FAV, de 40 pacientes que asistieron a hemodiálisis. La recolección de los datos se llevó a cabo, con un formato que incluyó el resultado de la pulsioximetria y variables asociadas, antes, durante y después de la hemodiálisis. Se comparó la mediana de los deltas de las diferencias con pruebas estadísticas T Student – Mann Whitney, aceptando un valor significativo de p < 0,05. Resultados. No se encontraron diferencias estadísticamente significativas de la SpO2 entre el brazo con FAV y el brazo sin FAV, antes, durante y después de la diálisis, sin embargo si se apreció una correlación positiva estadísticamente significativa. Conclusiones. Se encontró correlación positiva estadísticamente significativa, donde no hubo diferencias en el resultado la pulsioximetría entre el brazo con FAV y brazo sin FAV, por lo tanto es válido tomar la pulsioximetría en cualquiera de los brazos.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Web-based tool developed to automatically correct relational database schemas is presented. This tool has been integrated into a more general e-learning platform and is used to reinforce teaching and learning on database courses. This platform assigns to each student a set of database problems selected from a common repository. The student has to design a relational database schema and enter it into the system through a user friendly interface specifically designed for it. The correction tool corrects the design and shows detected errors. The student has the chance to correct them and send a new solution. These steps can be repeated as many times as required until a correct solution is obtained. Currently, this system is being used in different introductory database courses at the University of Girona with very promising results

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Compositional data, also called multiplicative ipsative data, are common in survey research instruments in areas such as time use, budget expenditure and social networks. Compositional data are usually expressed as proportions of a total, whose sum can only be 1. Owing to their constrained nature, statistical analysis in general, and estimation of measurement quality with a confirmatory factor analysis model for multitrait-multimethod (MTMM) designs in particular are challenging tasks. Compositional data are highly non-normal, as they range within the 0-1 interval. One component can only increase if some other(s) decrease, which results in spurious negative correlations among components which cannot be accounted for by the MTMM model parameters. In this article we show how researchers can use the correlated uniqueness model for MTMM designs in order to evaluate measurement quality of compositional indicators. We suggest using the additive log ratio transformation of the data, discuss several approaches to deal with zero components and explain how the interpretation of MTMM designs di ers from the application to standard unconstrained data. We show an illustration of the method on data of social network composition expressed in percentages of partner, family, friends and other members in which we conclude that the faceto-face collection mode is generally superior to the telephone mode, although primacy e ects are higher in the face-to-face mode. Compositions of strong ties (such as partner) are measured with higher quality than those of weaker ties (such as other network members)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'objectiu d'aquest article és presentar l'estructura de la base de dades relacional que inclou tota la informació sintictica continguda en el Diccionario Critico Etimológico Castellano e Hispánico de J. Corominas i J. A. Pascual. Tot i que aquest diccionari conté un ampli ventall d'informacions històriques de cadascun dels temes, aquestes no es mostren de forma estructurada, per la qual cosa ha estat necessari estudiar i classificar tots aquells elements relacionats amb aspectes sintàctics. És a partir d'aquest estudi previ que s'han elaborat els diferents camps de la base de dades, els quals s'agrupen en cinc blocs temàtics: informació lemàtica; gramatical; sintàctica; altres aspectes relacionats; i observacions o comentaris rellevants fets per l'investigador. Aquesta base de dades no només reprodueix els continguts del diccionari, sinó que inclou diferents camps interpretatius. Per aquesta raó, Syntax. dbf representa una eina de treball fonamental per a tots aquells investigadors interessats en la sintaxi diacrònica de l'espanyol

Relevância:

20.00% 20.00%

Publicador:

Resumo:

En les últimes dècades, l'increment dels nivells de radiació solar ultraviolada (UVR) que arriba a la Terra (principalment degut a la disminució d'ozó estratosfèric) juntament amb l'augment detectat en malalties relacionades amb l'exposició a la UVR, ha portat a un gran volum d'investigacions sobre la radiació solar en aquesta banda i els seus efectes en els humans. L'índex ultraviolat (UVI), que ha estat adoptat internacionalment, va ser definit amb el propòsit d'informar al públic general sobre els riscos d'exposar el cos nu a la UVR i per tal d'enviar missatges preventius. L'UVI es va definir inicialment com el valor màxim diari. No obstant, el seu ús actual s'ha ampliat i té sentit referir-se a un valor instantani o a una evolució diària del valor d'UVI mesurat, modelitzat o predit. El valor concret d'UVI està afectat per la geometria Sol-Terra, els núvols, l'ozó, els aerosols, l'altitud i l'albedo superficial. Les mesures d'UVI d'alta qualitat són essencials com a referència i per estudiar tendències a llarg termini; es necessiten també tècniques acurades de modelització per tal d'entendre els factors que afecten la UVR, per predir l'UVI i com a control de qualitat de les mesures. És d'esperar que les mesures més acurades d'UVI s'obtinguin amb espectroradiòmetres. No obstant, com que els costs d'aquests dispositius són elevats, és més habitual trobar dades d'UVI de radiòmetres eritemàtics (de fet, la majoria de les xarxes d'UVI estan equipades amb aquest tipus de sensors). Els millors resultats en modelització s'obtenen amb models de transferència radiativa de dispersió múltiple quan es coneix bé la informació d'entrada. No obstant, habitualment no es coneix informació d'entrada, com per exemple les propietats òptiques dels aerosols, la qual cosa pot portar a importants incerteses en la modelització. Sovint, s'utilitzen models més simples per aplicacions com ara la predicció d'UVI o l'elaboració de mapes d'UVI, ja que aquests són més ràpids i requereixen menys paràmetres d'entrada. Tenint en compte aquest marc de treball, l'objectiu general d'aquest estudi és analitzar l'acord al qual es pot arribar entre la mesura i la modelització d'UVI per condicions de cel sense núvols. D'aquesta manera, en aquest estudi es presenten comparacions model-mesura per diferents tècniques de modelització, diferents opcions d'entrada i per mesures d'UVI tant de radiòmetres eritemàtics com d'espectroradiòmeters. Com a conclusió general, es pot afirmar que la comparació model-mesura és molt útil per detectar limitacions i estimar incerteses tant en les modelitzacions com en les mesures. Pel que fa a la modelització, les principals limitacions que s'han trobat és la falta de coneixement de la informació d'aerosols considerada com a entrada dels models. També, s'han trobat importants diferències entre l'ozó mesurat des de satèl·lit i des de la superfície terrestre, la qual cosa pot portar a diferències importants en l'UVI modelitzat. PTUV, una nova i simple parametrització pel càlcul ràpid d'UVI per condicions de cel serens, ha estat desenvolupada en base a càlculs de transferència radiativa. La parametrització mostra una bona execució tant respecte el model base com en comparació amb diverses mesures d'UVI. PTUV ha demostrat la seva utilitat per aplicacions particulars com ara l'estudi de l'evolució anual de l'UVI per un cert lloc (Girona) i la composició de mapes d'alta resolució de valors d'UVI típics per un territori concret (Catalunya). En relació a les mesures, es constata que és molt important saber la resposta espectral dels radiòmetres eritemàtics per tal d'evitar grans incerteses a la mesura d'UVI. Aquest instruments, si estan ben caracteritzats, mostren una bona comparació amb els espectroradiòmetres d'alta qualitat en la mesura d'UVI. Les qüestions més importants respecte les mesures són la calibració i estabilitat a llarg termini. També, s'ha observat un efecte de temperatura en el PTFE, un material utilitzat en els difusors en alguns instruments, cosa que potencialment podria tenir implicacions importants en el camp experimental. Finalment, i pel que fa a les comparacions model-mesura, el millor acord s'ha trobat quan es consideren mesures d'UVI d'espectroradiòmetres d'alta qualitat i s'usen models de transferència radiativa que consideren les millors dades disponibles pel que fa als paràmetres òptics d'ozó i aerosols i els seus canvis en el temps. D'aquesta manera, l'acord pot ser tan alt dins un 0.1º% en UVI, i típicament entre menys d'un 3%. Aquest acord es veu altament deteriorat si s'ignora la informació d'aerosols i depèn de manera important del valor d'albedo de dispersió simple dels aerosols. Altres dades d'entrada del model, com ara l'albedo superficial i els perfils d'ozó i temperatura introdueixen una incertesa menor en els resultats de modelització.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a review of a study on distortion product emissions in normal hearing chinchillas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper is a review of a study to determine whether the use of otoscopic examination and middle ear impedance measurement are feasible tools for use by an audiologist during a screening program.