958 resultados para reliability measurement
Resumo:
Aims:This study was carried out to evaluate the feasibility of two different methods to determine free flap perfusion in cancer patients undergoing major reconstructive surgery. The hypotheses was that low perfusion in the flap is associated with flap complications. Patients and methods: Between August 2002 and June 2008 at the Department of Otorhinolaryngology – Head and Neck Surgery, Department of Surgery, and at the PET Centre, Turku, 30 consecutive patients with 32 free flaps were included in this study. The perfusion of the free microvascular flaps was assessed with positron emission tomography (PET) and radioactive water ([15O] H2O) in 40 radiowater injections in 33 PET studies. Furthermore, 24 free flaps were monitored with a continuous tissue oxygen measurement using flexible polarographic catheters for an average of three postoperative days. Results: Of the 17 patients operated on for head and neck (HN) cancer and reconstructed with 18 free flaps, three re-operations were carried out due to poor tissue oxygenation as indicated by ptiO2 monitoring results and three other patients were reoperated on for postoperative hematomas in the operated area. Blood perfusion assessed with PET (BFPET) was above 2.0 mL / min / 100 g in all flaps and a low flap-to-muscle BFPET ratio appeared to correlate with poor survival of the flap. Survival in this group of HN cancer patients was 9.0 months (median, range 2.4-34.2) after a median follow-up of 11.9 months (range 1.0-61.0 months). Seven HN patients of this group are alive without any sign of recurrence and one patient has died of other causes. All of the 13 breast reconstruction patients included in the study are alive and free of disease at a median follow-up time of 27.4 months (range 13.9-35.7 months). Re-explorations were carried out in three patients due data provided by ptiO2 monitoring and one re-exploration was avoided on the basis of adequate blood perfusion assessed with PET. Two patients had donorsite morbidity and 3 patients had partial flap necrosis or fat necrosis. There were no total flap losses. Conclusions: PtiO2 monitoring is a feasible method of free flap monitoring when flap temperature is monitored and maintained close to the core temperature. When other monitoring methods give controversial results or are unavailable, [15O] H2O PET technique is feasible in the evaluation of the perfusion of the newly reconstructed free flaps.
Resumo:
Various strength properties of paper are measured to tell how well it resists breaks in a paper machine or in printing presses. The most often measured properties are dry tensile strength and dry tear strength. However, in many situations where paper breaks, it is not dry. For example, in web breaks after the wet pressing the dry matter content can be around 45%. Thus, wet-web strength is often a more critical paper property than dry strength. Both wet and dry strength properties of the samples were measured with a L&W tensile tester. Originally this device was not designed for the measurement of the wet web tensile strength, thus a new procedure to handle the wet samples was developed. The method was tested with Pine Kraft (never dried). The effect of different strength additives on the wet-web and dry paper tensile strength was studied. The polymers used in this experiment were aqueous solution of a cationic polyamidoamine-epichlorohydrin resin (PAE), cationic hydrophilised polyisocyanate and cationic polyvinylamine (PVAm). From all three used chemicals only Cationic PAE considerably increased the wet web strength. However it was noticed that at constant solids content all chemicals decreased the wet web tensile strength. So, since all chemicals enhanced solid content it can be concluded that they work as drainage aids, not as wet web strength additives. From all chemicals only PVAm increased the dry strength and two other chemicals even decreased the strength. As chemicals were used in strong diluted forms and were injected into the pulp slurry, not on the surface of the papersheets, changes in samples densities did not happen. Also it has to be noted that all these chemicals are mainly used to improve the wet strength after the drying of the web.
Resumo:
Teaching the measurement of blood pressure for both nursing and public health nursing students The purpose of this two-phase study was to develop the teaching of blood pressure measurement within the nursing degree programmes of the Universities of Applied Sciences. The first survey phase described what and how blood pressure measurement was taught within nursing degree programmes. The second intervention phase (2004-2005) evaluated first academic year nursing and public health nursing students’ knowledge and skills results for blood pressure measurement. Additionally, the effect on the Taitoviikko experimental group students’ blood pressure measurement knowledge and skills level. A further objective was to construct models for an instrument (RRmittTest) to evaluate nursing students measurement of blood pressure (2003-2009). The research data for the survey phase were collected from teachers (total sampling, N=107, response rate 77%) using a specially developed RRmittopetus-questionnaire. Quasi-experimental study data on the RRmittTest-instrument was collected from students (purposive sampling, experimental group, n=29, control group, n=44). The RRmittTest consisted of a test of knowledge (Tietotesti) and simulation-based test (TaitoSimkäsi and Taitovideo) of skills. Measurements were made immediately after the teaching and in clinical practice. Statistical methods were used to analyse the results and responses to open-ended questions were organised and classified. Due to the small amount of materials involved and the results of distribution tests of the variables, non-parametric analytic methods were mainly used. Experimental group and control group similar knowledge and skills teaching was based on the results of the national survey phase (RRmittopetus) questionnaire results. Experimental group teaching includes the supervised Taitoviikko teaching method. During Taitoviikko students studied blood pressure measurement at the municipal hospital in a real nursing environment, guided by a teacher and a clinical nursing professional. In order to evaluate both learning and teaching the processes and components of blood pressure measurement were clearly defined as follows: the reliability of measurement instruments, activities preceding blood pressure measurement, technical execution of the measurement, recording, lifestyle guidance and measurement at home (self-monitoring). According to the survey study, blood pressure measurement is most often taught at Universities of Applied Sciences, separately, as knowledge (teaching of theory, 2 hours) and skills (classroom practice, 4 hours). The teaching was implemented largely in a classroom and was based mainly on a textbook. In the intervention phase the students had good knowledge of blood pressure measurement. However, their blood pressure measurement skills were deficient and the control group students, in particular, were highly deficient. Following in clinical practice the experimental group and control group students’ blood pressure measurement recording knowledge improve and experimental groups declined lifestyle guidance. Skills did not improve within any of the components analysed. The control groups` skills on the whole, declined statistically.There was a significant decline amongst the experimental group although only in one component measured. The results describe the learning results for first academic year students and no parallel conclusions should be drawn when considering any learning results for graduating students. The results support the use and further development of the Taitoviiko teaching method. The RRmittTest developed for the study should be assessed and the results seen from a negative perspective. This evaluation tool needs to be developed and retested.
Resumo:
The objective of the thesis was to create a performance measurement system for the logistics process of a company. In addition, one goal was to make suggestions for improvements based on description and analysis of the process and current measures. The logistics process was described in detail, and the objectives for it were derived from the company strategy and goals. Suggestions for performance measurement system and process improvement were made based on current state analysis. As a result of the thesis, three new performance measures were decided to take into use. In addition, several improvements were suggested to the ERP system to make process smoother. Some of the improvements have already been added to the system and the rest will be added in the near future.
Resumo:
Tämän tutkielman tarkoituksena on tehostaa toimitusketjua kehittämällä palvelutasosopimusta ja parantamalla toimitusvarmuutta toimittajan ja oy Shell ab:n välillä. Työssä perehdytään näiden kahden yrityksen väliseen sopimukseen ja toimitusvarmuutta kuvaavaan mittariin nimeltä Supplier OTIF. Nykytila arvioidaan molempien osalta ja mahdollisia parantavia toimenpiteitä tuodaan esille. Tämä tutkimus perustuu yrityksessä työskentelyn ohella haastatteluihin, kyselyihin sekä omiin havaintoihin eri osastoilla. Työn teoriaosuudessa tarkastellaan ostosopimuksen yleisintä kaupallista sisältöä. Lisäksi paneudutaan palveluyrityksen käytäntöihin, tulkitaan palveluyrityksen suorituskykyä ja sen mittaamista tunnuslukujen avulla. Tutkimus osoittaa, että niin palvelutasosopimus kuin toimitusvarmuuskin eivät ole riittävällä tasolla case-yrityksessä. Erityisesti osapuolien välistä yhteistyötä ja tiedonjakoa on parannettava tavoitteiden saavuttamiseksi. Työssä esiteltyjen kehitys- ja parannusehdotusten osittainen käyttöönotto aikaansai toimitusketjun tehokkaamman toiminnan. Case-yrityksen tuleekin harkita lisätoimenpiteiden käyttöönottoa. Toiminnan sekä yhteistyön parantaminen yhä edelleen jää case-yrityksen ja toimittajien yhteisesti tulevaisuudessa tehtävien ratkaisujen varaan.
Resumo:
The objective of this study is to create measurement system that is capable to measure performance in basic industry’s service centers. First it is examined what is performance and how it can be measured. The study also introduces commonly known measurement frameworks. After theory the study investigates how companies in the field of basic industry measure their operations in practise. The investigation is done examining three case examples and by analyzing survey results from basic industry companies. On the survey results focus is on what meters and measurement systems companies use. It is also viewed what measurement problems companies have faced. In the applied part of the study harmonized performance measurement system is created. The framework of the measurement system is introduced and measurement system for the target company is created. The target company felt that the harmonized performance measurement system has good potential and continues to develop it further.
Resumo:
Supersonic axial turbine stages typically exhibit lower efficiencies than subsonic axial turbine stages. One reason for the lower efficiency is the occurrence of shock waves. With higher pressure ratios the flow inside the turbine becomes relatively easily supersonic if there is only one turbine stage. Supersonic axial turbines can be designed in smaller physical size compared to subsonic axial turbines of same power. This makes them good candidates for turbochargers in large diesel engines, where space can be a limiting factor. Also the production costs are lower for a supersonic axial turbine stage than for two subsonic stages. Since supersonic axial turbines are typically low reaction turbines, they also create lower axial forces to be compensated with bearings compared to high reaction turbines. The effect of changing the stator-rotor axial gap in a small high (rotational) speed supersonic axial flow turbine is studied in design and off-design conditions. Also the effect of using pulsatile mass flow at the supersonic stator inlet is studied. Five axial gaps (axial space between stator and rotor) are modeled using threedimensional computational fluid dynamics at the design and three axial gaps at the off-design conditions. Numerical reliability is studied in three independent studies. An additional measurement is made with the design turbine geometry at intermediate off-design conditions and is used to increase the reliability of the modelling. All numerical modelling is made with the Navier-Stokes solver Finflo employing Chien’s k ¡ ² turbulence model. The modelling of the turbine at the design and off-design conditions shows that the total-to-static efficiency of the turbine decreases when the axial gap is increased in both design and off-design conditions. The efficiency drops almost linearily at the off-design conditions, whereas the efficiency drop accelerates with increasing axial gap at the design conditions. The modelling of the turbine stator with pulsatile inlet flow reveals that the mass flow pulsation amplitude is decreased at the stator throat. The stator efficiency and pressure ratio have sinusoidal shapes as a function of time. A hysteresis-like behaviour is detected for stator efficiency and pressure ratio as a function of inlet mass flow, over one pulse period. This behaviour arises from the pulsatile inlet flow. It is important to have the smallest possible axial gap in the studied turbine type in order to maximize the efficiency. The results for the whole turbine can also be applied to some extent in similar turbines operating for example in space rocket engines. The use of a supersonic stator in a pulsatile inlet flow is shown to be possible.
Resumo:
Tutkimuksen tavoitteena oli arvioida, miten tuottavuustietoa voidaan hyödyntää johtamisen tukena ja kuinka tuottavuustietoa tällä hetkellä hyödynnetään Etelä-Karjalan keskussairaalassa (EKKS). Tuottavuuden mittaamisessa hyödynnetään Terveyden- ja hyvinvoinnin laitoksen (THL) vuosittain julkaisemassa Hoito-toiminnan tuottavuus -tilastossa käytettävää tuottavuuden mittaamismenetelmää, jossa panoksina ovat sairaalan tai erikoisalan hoitotoiminnasta aiheutuneet kustannukset ja tuotoksina NordDRG-ryhmittelijän avulla painotetut hoitojaksot ja käynnit. Tutkimuksessa arvioitiin tuottavuuden mittaamiseen liittyvien mahdollisten virhetekijöiden vaikutusta sairaalan tuottavuuteen EKKS:n tapauksessa ja tämän perusteella tunnistettiin, miten THL:n julkaisemaa tuottavuustilastoa ja sisäistä tuottavuustietoa voidaan hyödyntää sairaalan johtamisen tukena. Pääasiallisena aineistona työssä käytettiin EKKS:n henkilöstön haastatteluja ja sairaalan taloudellisia raportteja sekä THL:n julkista ja julkaisematonta aineistoa. THL:n kehittämän hoitotoiminnan tuottavuuden mittaamismenetelmän havaittiin soveltuvan yksittäisen sairaalan käyttöön tietyin muutoksin. Vaadittavien muutosten lisäksi tutkimuksessa tunnistettiin taustatekijät, jotka THL:n tuottavuustilaston ja sisäisen tuottavuustiedon tulkitsijan tulee ottaa huomioon. EKKS:n tuottavuustietojen keruussa havaittiin kehittämiskohteita, joita paran-tamalla tuottavuustiedon luotettavuutta ja hyödynnettävyyttä voidaan edelleen kehittää. Tuottavuustiedon hyödyntämistä voidaan niin ikään edelleen kehittää EKKS:ssa.
Resumo:
In recent years, the network vulnerability to natural hazards has been noticed. Moreover, operating on the limits of the network transmission capabilities have resulted in major outages during the past decade. One of the reasons for operating on these limits is that the network has become outdated. Therefore, new technical solutions are studied that could provide more reliable and more energy efficient power distributionand also a better profitability for the network owner. It is the development and price of power electronics that have made the DC distribution an attractive alternative again. In this doctoral thesis, one type of a low-voltage DC distribution system is investigated. Morespecifically, it is studied which current technological solutions, used at the customer-end, could provide better power quality for the customer when compared with the current system. To study the effect of a DC network on the customer-end power quality, a bipolar DC network model is derived. The model can also be used to identify the supply parameters when the V/kW ratio is approximately known. Although the model provides knowledge of the average behavior, it is shown that the instantaneous DC voltage ripple should be limited. The guidelines to choose an appropriate capacitance value for the capacitor located at the input DC terminals of the customer-end are given. Also the structure of the customer-end is considered. A comparison between the most common solutions is made based on their cost, energy efficiency, and reliability. In the comparison, special attention is paid to the passive filtering solutions since the filter is considered a crucial element when the lifetime expenses are determined. It is found out that the filter topology most commonly used today, namely the LC filter, does not provide economical advantage over the hybrid filter structure. Finally, some of the typical control system solutions are introduced and their shortcomings are presented. As a solution to the customer-end voltage regulation problem, an observer-based control scheme is proposed. It is shown how different control system structures affect the performance. The performance meeting the requirements is achieved by using only one output measurement, when operating in a rigid network. Similar performance can be achieved in a weak grid by DC voltage measurement. An additional improvement can be achieved when an adaptive gain scheduling-based control is introduced. As a conclusion, the final power quality is determined by a sum of various factors, and the thesis provides the guidelines for designing the system that improves the power quality experienced by the customer.
Resumo:
The main objective of this research is creating a performance measurement system for accounting services of a large paper industry company. In this thesis there are compared different performance measurement system and then selected two systems, which are presented and compared more detailed. Performance Prism system is the used framework in this research. Performance Prism using success maps to determining objectives. Model‟s target areas are divided into five groups: stakeholder satisfaction, stakeholder contribution, strategy, processes and capabilities. The measurement system creation began by identifying stakeholders and defining their objectives. Based on the objectives are created success map. Measures are created based on the objectives and success map. Then is defined needed data for measures. In the final measurement system, there are total just over 40 measures. Each measure is defined specific target level and ownership. Number of measures is fairly large, but this is the first version of the measurement system, so the amount is acceptable.
Resumo:
Centrifugal pumps are widely used in industrial and municipal applications, and they are an important end-use application of electric energy. However, in many cases centrifugal pumps operate with a significantly lower energy efficiency than they actually could, which typically has an increasing effect on the pump energy consumption and the resulting energy costs. Typical reasons for this are the incorrect dimensioning of the pumping system components and inefficiency of the applied pump control method. Besides the increase in energy costs, an inefficient operation may increase the risk of a pump failure and thereby the maintenance costs. In the worst case, a pump failure may lead to a process shutdown accruing additional costs. Nowadays, centrifugal pumps are often controlled by adjusting their rotational speed, which affects the resulting flow rate and output pressure of the pumped fluid. Typically, the speed control is realised with a frequency converter that allows the control of the rotational speed of an induction motor. Since a frequency converter can estimate the motor rotational speed and shaft torque without external measurement sensors on the motor shaft, it also allows the development and use of sensorless methods for the estimation of the pump operation. Still today, the monitoring of pump operation is based on additional measurements and visual check-ups, which may not be applicable to determine the energy efficiency of the pump operation. This doctoral thesis concentrates on the methods that allow the use of a frequency converter as a monitoring and analysis device for a centrifugal pump. Firstly, the determination of energy-efficiency- and reliability-based limits for the recommendable operating region of a variable-speed-driven centrifugal pump is discussed with a case study for the laboratory pumping system. Then, three model-based estimation methods for the pump operating location are studied, and their accuracy is determined by laboratory tests. In addition, a novel method to detect the occurrence of cavitation or flow recirculation in a centrifugal pump by a frequency converter is introduced. Its sensitivity compared with known cavitation detection methods is evaluated, and its applicability is verified by laboratory measurements for three different pumps and by using two different frequency converters. The main focus of this thesis is on the radial flow end-suction centrifugal pumps, but the studied methods can also be feasible with mixed and axial flow centrifugal pumps, if allowed by their characteristics.
Resumo:
The objective of the study is to find out how sales performance should be measured and how should sales be steered in a multinational company. The beginning of the study concentrates on the literature regarding sales, performance measurement, sales performance measurement, and sales steering. The empirical part of the study is a case study, in which the information was acquired from interviews with the key personnel of the company. The results of the interviews and the revealed problems were analyzed, and comparison for possible solutions was performed. When measuring sales performance, it is important to discover the specific needs and objectives for such a system. Specific needs should be highlighted in the design of the system. The system should be versatile and the structure of the system should be in line with the organizational structure. The role of the sales performance measurement system was seen to be important in helping sales steering. However, the importance of personal management and especially conversations were seen as really critical issue in the steering. Sales performance measurement could be based on the following perspectives: financial, market, customer, people, and future. That way the sales department could react to the environmental changes more rapidly.
Resumo:
Solar radiation is an important factor for plant growth, being its availability to understory crops strongly modified by trees in an Agroforestry System (AFS). Coffee trees (Coffea arabica - cv. Obatã IAC 1669-20) were planted at a 3.4 x 0.9 m spacing inside and aside rows of monocrops of 12 year-old rubber trees (Hevea spp.), in Piracicaba-SP, Brazil (22º42'30" S, 47º38'00" W - altitude: 546m). One-year-old coffee plants exposed to 25; 30; 35; 40; 45; 80; 90; 95 and 100% of the total solar radiation were evaluated according to its biophysical parameters of solar radiation interception and capture. The Goudriaan (1977) adapted by Bernardes et al. (1998) model for radiation attenuation fit well to the measured data. Coffee plants tolerate a decrease in solar radiation availability to 50% without undergoing a reduction on growth and LAI, which was approximately 2m².m-2 under this condition. Further reductions on the availability of solar radiation caused a reduction in LAI (1.5m².m-2), thus poor land cover and solar radiation interception, resulting in growth reduction.