1000 resultados para Regeneração vegetal
Resumo:
Climatic changes that affected the Northeastern Atlantic frontage are analyzed on the basis of the evolution of faunas and floras from the late Oligocene onwards. The study deals with calcareous nannoplankton, marine micro- and macrofaunas, some terrestrial vertebrates and vegetal assemblages. The climate, first tropical, underwent a progressive cooling (North-South thermic gradient). Notable climatic deteriorations (withdrawal towards the South or disappearance of taxa indicative of warm climate and appearance of "cold" taxa) are evidenced mainly during the Middle Miocene and the late Pliocene. Faunas and floras of modern pattern have regained, after the Pleistocene glaciations, a new climatic ranging of a temperate type in the northern part.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil Engenharia Ecológica
Resumo:
O sistema enzimático fenoloxidase (EC 1.10.3.1, EC 1.10.3.2) está amplamente distribuido entre os seres vivos, tendo sido descrito em diferentes espécies do reino animal e vegetal. Apesar de desempenhar um papel fundamental na formação da cápsula ou parede dos ovos de trematódeos, o sistema enzimático fenoloxidase (PO) tem sido pouco estudado nesses organismos. No presente trabalho são apresentados os resultados iniciais de imunizações de coelhos contra PO de fêmeas adultas de S. mansoni e tirosinase de cogumelo (Sigma). As análises imunológicas, realizadas através de imunodifusão dupla (teste de Ouchterlony) e imunoeletroforese, revelaram identidade imunitária parcial entre a PO de machos e fêmeas. Não se observou reação cruzada entre os antissoros de coelhos imunizados contra PO e aqueles com tirosinase, indicando que, embora os sítios catalíticos de ambas as enzimas devam ser semelhantes, já que atuam sobre os mesmos substratos, os determinantes antigênicos devem ser diferentes. Os resultados descritos no presente trabalho representam um primeiro passo no sentido da purificação das isoenzimas da fenoloxidase e sua posterior utilização ao estudo dos mecanismos moleculares envolvidos na esclerotização da parede dos ovos de S. mansoni.
Resumo:
A presente dissertação foi realizada em colaboração com o grupo empresarial Monteiro, Ribas, tendo como principal objectivo a realização de uma auditoria à gestão dos resíduos industriais produzidos pelas suas fábricas localizadas na Estrada da Circunvalação, no Porto. Para cumprir este objectivo, inicialmente foi efectuado um levantamento das obrigações legais relativas aos resíduos e foram procuradas práticas aconselhadas para a gestão interna. Para cada uma das fábricas, verificaram-se, quais os resíduos produzidos e analisaram-se os seus percursos, considerando as suas origens, os locais e modos de acondicionamento na origem, os modos de transporte interno, os locais e modos de armazenagem preliminar, e ainda, as quantidades produzidas, os transportadores, os operadores finais e as operações finais de gestão, sendo que estas quatro últimas informações são relativas ao ano 2013. De seguida procedeu-se à realização da auditoria nas diferentes unidades, verificando o cumprimento dos requisitos legais e das boas práticas em matéria de gestão de resíduos. As principais não conformidades detectadas, comuns às várias unidades fabris foram a inexistência de local/recipiente definido para acondicionamento de alguns resíduos, a falta ou insuficiente identificação de recipientes/zonas de acondicionamento, a inexistência de bacias de retenção para resíduos líquidos perigosos, o facto de no transporte interno apenas os resíduos perigosos serem cobertos e, os resíduos líquidos perigosos não serem transportados sobre bacias de retenção móveis nem com o material necessário para absorver derrames. Para cada resíduo e para cada unidade industrial foram propostas medidas correctivas e/ou de melhoria, quando aplicável. Relativamente à armazenagem preliminar, a principal inconformidade detectada foi o facto de todos os parques (quatro) possuírem resíduos perigosos no momento das auditorias, o que não é adequado. Foram propostas medidas correctivas e/ou de melhoria para cada parque. Como proposta global, tendo em conta factores económicos e de segurança, sugeriu-se que apenas o parque de resíduos perigosos possa armazenar este tipo de resíduos, pelo que os procedimentos de transporte interno devem ser melhorados, fazendo com que estes resíduos sejam transportados directamente para o parque de resíduos perigosos. Desta forma dois dos parques devem sofrer algumas remodelações, nomeadamente serem cobertos e fechados, ainda que não totalmente, e o parque de resíduos perigosos deve ser fechado, mantendo aberturas para ventilação, deve ser equipado com kit´s de contenção de derrames, fichas de segurança, procedimentos a realizar em caso de emergência, e ainda, devido ao facto do sistema de contenção de derrames ser pequeno face ao total de armazenamento, aconselha-se o uso de bacias de retenção para alguns dos recipientes de resíduos líquidos perigosos. Ao longo deste processo e em consequência da realização da auditoria, algumas situações consideradas não conformes foram sendo corrigidas. Também foram preparadas instruções de trabalho adequadas que serão posteriormente disponibilizadas. Foi ainda elaborada uma metodologia de avaliação de processos como base de trabalho para redução dos resíduos gerados. A etapa escolhida para a aplicação da mesma foi uma etapa auxiliar do processo produtivo da Monteiro, Ribas - Revestimentos, S.A - a limpeza de cubas com solventes, por forma a tentar minimizar os resíduos de solventes produzidos nesta operação. Uma vez que a fábrica já realiza a operação tendo em consideração medidas de prevenção e reutilização, a reciclagem é neste momento a única forma de tentar minimizar os resíduos de solventes. Foram então estudadas duas opções, nomeadamente a aquisição de um equipamento de regeneração de solventes e a contratação de uma operadora que proceda à regeneração dos resíduos de solventes e faça o retorno do solvente regenerado. A primeira opção poderá permitir uma redução de cerca de 95% na produção de resíduos de solventes e na aquisição de solvente puro, estimando-se uma poupança anual de cerca de **** €, com um período de recuperação do capital de cerca de 16 meses e a segunda pode conduzir a uma redução significativa na aquisição de solvente puro, cerca de 65%, e a uma poupança anual de cerca de **** €.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil de Engenharia Ecológica
Resumo:
Dissertação apresentada para cumprimento dos requisitos necessários à obtenção do grau de Mestre em Ciências Musicais, variante de Musicologia Histórica
Resumo:
RESUMO - A exposição a formaldeído é reconhecidamente um dos mais importantes factores de risco presente nos laboratórios hospitalares de anatomia patológica. Neste contexto ocupacional, o formaldeído é utilizado em solução, designada comummente por formol. Trata-se de uma solução comercial de formaldeído, normalmente diluída a 10%, sendo pouco onerosa e, por esse motivo, a eleita para os trabalhos de rotina em anatomia patológica. A solução é utilizada como fixador e conservante do material biológico, pelo que as peças anatómicas a serem processadas são previamente impregnadas. No que concerne aos efeitos para a saúde do formaldeído, os efeitos locais parecem apresentar um papel mais importante comparativamente com os efeitos sistémicos, devido à sua reactividade e rápido metabolismo nas células da pele, tracto gastrointestinal e pulmões. Da mesma forma, a localização das lesões correspondem principalmente às zonas expostas às doses mais elevadas deste agente químico, ou seja, o desenvolvimento dos efeitos tóxicos dependerá mais da intensidade da dose externa do que da duração da exposição. O efeito do formaldeído no organismo humano mais facilmente detectável é a acção irritante, transitória e reversível sobre as mucosas dos olhos e aparelho respiratório superior (naso e orofaringe), o que acontece em geral para exposições frequentes e superiores a 1 ppm. Doses elevadas são citotóxicas e podem conduzir a degenerescência e necrose das mucosas e epitélios. No que concerne aos efeitos cancerígenos, a primeira avaliação efectuada pela International Agency for Research on Cancer data de 1981, actualizada em 1982, 1987, 1995 e 2004, considerando-o como um agente cancerígeno do grupo 2A (provavelmente carcinogénico). No entanto, a mais recente avaliação, em 2006, considera o formaldeído no Grupo 1 (agente carcinogénico) com base na evidência de que a exposição a este agente é susceptível de causar cancro nasofaríngeo em humanos. Constituiu objectivo principal deste estudo caracterizar a exposição profissional a formaldeído nos laboratórios hospitalares de anatomia patológica Portugueses. Pretendeu-se, ainda, descrever os fenómenos ambientais da contaminação ambiental por formaldeído e explorar eventuais associações entre variáveis. Considerou-se uma amostra de 10 laboratórios hospitalares de anatomia patológica, avaliada a exposição dos três grupos profissionais por comparação com os dois referenciais de exposição e, ainda, conhecidos os valores de concentração máxima em 83 actividades. Foram aplicados simultaneamente dois métodos distintos de avaliação ambiental: um dos métodos (Método 1) fez uso de um equipamento de leitura directa com o princípio de medição por Photo Ionization Detection, com uma lâmpada de 11,7 eV e, simultaneamente, realizou-se o registo da actividade. Este método disponibilizou dados para o referencial de exposição da concentração máxima; o outro método (Método 2) traduziu-se na aplicação do método NIOSH 2541, implicando o uso de bombas de amostragem eléctricas de baixo caudal e posterior processamento analítico das amostras por cromatografia gasosa. Este método, por sua vez, facultou dados para o referencial de exposição da concentração média ponderada. As estratégias de medição de cada um dos métodos e a definição dos grupos de exposição existentes neste contexto ocupacional, designadamente os Técnicos de Anatomia Patológica, os Médicos Anatomo-Patologistas e os Auxiliares, foram possíveis através da informação disponibilizada pelas técnicas de observação da actividade da análise (ergonómica) do trabalho. Estudaram-se diversas variáveis independentes, nomeadamente a temperatura ambiente e a humidade relativa, a solução de formaldeído utilizada, as condições de ventilação existentes e o número médio de peças processadas por dia em cada laboratório. Para a recolha de informação sobre estas variáveis foi preenchida, durante a permanência nos laboratórios estudados, uma Grelha de Observação e Registo. Como variáveis dependentes seleccionaram-se três indicadores de contaminação ambiental, designadamente o valor médio das concentrações superiores a 0,3 ppm em cada laboratório, a Concentração Média Ponderada obtida para cada grupo de exposição e o Índice do Tempo de Regeneração de cada laboratório. Os indicadores foram calculados e definidos através dos dados obtidos pelos dois métodos de avaliação ambiental aplicados. Baseada no delineado pela Universidade de Queensland, foi ainda aplicada uma metodologia de avaliação do risco de cancro nasofaríngeo nas 83 actividades estudadas de modo a definir níveis semi-quantitativos de estimação do risco. Para o nível de Gravidade considerou-se a informação disponível em literatura científica que define eventos biológicos adversos, relacionados com o modo de acção do agente químico e os associa com concentrações ambientais de formaldeído. Para o nível da Probabilidade utilizou-se a informação disponibilizada pela análise (ergonómica) de trabalho que permitiu conhecer a frequência de realização de cada uma das actividades estudadas. A aplicação simultânea dos dois métodos de avaliação ambiental resultou na obtenção de resultados distintos, mas não contraditórios, no que concerne à avaliação da exposição profissional a formaldeído. Para as actividades estudadas (n=83) verificou-se que cerca de 93% dos valores são superiores ao valor limite de exposição definido para a concentração máxima (VLE-CM=0,3 ppm). O “exame macroscópico” foi a actividade mais estudada e onde se verificou a maior prevalência de resultados superiores ao valor limite (92,8%). O valor médio mais elevado da concentração máxima (2,04 ppm) verificou-se no grupo de exposição dos Técnicos de Anatomia Patológica. No entanto, a maior amplitude de resultados observou-se no grupo dos Médicos Anatomo-Patologistas (0,21 ppm a 5,02 ppm). No que respeita ao referencial da Concentração Média Ponderada, todos os valores obtidos nos 10 laboratórios estudados para os três grupos de exposição foram inferiores ao valor limite de exposição definido pela Occupational Safety and Health Administration (TLV-TWA=0,75 ppm). Verificou-se associação estatisticamente significativa entre o número médio de peças processadas por laboratório e dois dos três indicadores de contaminação ambiental utilizados, designadamente o valor médio das concentrações superiores a 0,3 ppm (p=0,009) e o Índice do Tempo de Regeneração (p=0,001). Relativamente à temperatura ambiente não se observou associação estatisticamente significativa com nenhum dos indicadores de contaminação ambiental utilizados. A humidade relativa apresentou uma associação estatisticamente significativa apenas com o indicador de contaminação ambiental da Concentração Média Ponderada de dois grupos de exposição, nomeadamente com os Médicos Anatomo-Patologistas (p=0,02) e os Técnicos de Anatomia Patológica (p=0,04). A aplicação da metodologia de avaliação do risco nas 83 actividades estudadas permitiu verificar que, em cerca de dois terços (35%), o risco foi classificado como (pelo menos) elevado e, ainda, constatar que 70% dos laboratórios apresentou pelo menos 1 actividade com a classificação de risco elevado. Da aplicação dos dois métodos de avaliação ambiental e das informações obtidas para os dois referenciais de exposição pode concluir-se que o referencial mais adequado é a Concentração Máxima por estar associado ao modo de actuação do agente químico. Acresce, ainda, que um método de avaliação ambiental, como o Método 1, que permite o estudo das concentrações de formaldeído e simultaneamente a realização do registo da actividade, disponibiliza informações pertinentes para a intervenção preventiva da exposição por permitir identificar as actividades com a exposição mais elevada, bem como as variáveis que a condicionam. As peças anatómicas apresentaram-se como a principal fonte de contaminação ambiental por formaldeído neste contexto ocupacional. Aspecto de particular interesse, na medida que a actividade desenvolvida neste contexto ocupacional e, em particular na sala de entradas, é centrada no processamento das peças anatómicas. Dado não se perspectivar a curto prazo a eliminação do formaldeído, devido ao grande número de actividades que envolvem ainda a utilização da sua solução comercial (formol), pode concluir-se que a exposição a este agente neste contexto ocupacional específico é preocupante, carecendo de uma intervenção rápida com o objectivo de minimizar a exposição e prevenir os potenciais efeitos para a saúde dos trabalhadores expostos. ---------------- ABSTRACT - Exposure to formaldehyde is recognized as one of the most important risk factors present in anatomy and pathology laboratories from hospital settings. In this occupational setting, formaldehyde is used in solution, typically diluted to 10%, and is an inexpensive product. Because of that, is used in routine work in anatomy and pathology laboratories. The solution is applied as a fixative and preservative of biological material. Regarding formaldehyde health effects, local effects appear to have a more important role compared with systemic effects, due to his reactivity and rapid metabolism in skin, gastrointestinal tract and lungs cells. Likewise, lesions location correspond mainly to areas exposed to higher doses and toxic effects development depend more on external dose intensity than exposure duration. Human body formaldehyde effect more easily detectable is the irritating action, transient and reversible on eyes and upper respiratory tract (nasal and throat) membranes, which happen in general for frequent exposure to concentrations higher than 1 ppm. High doses are cytotoxic and can lead to degeneration, and also to mucous membranes and epithelia necrosis. With regard to carcinogenic effects, first assessment performed by International Agency for Research on Cancer in 1981, updated in 1982, 1987, 1995 and 2004, classified formaldehyde in Group 2A (probably carcinogenic). However, most recent evaluation in 2006, classifies formaldehyde carcinogenic (Group 1), based on evidence that exposure to this agent is likely to cause nasopharyngeal cancer in humans. This study principal objective was to characterize occupational exposure to formaldehyde in anatomy and pathology hospital laboratories, as well to describe formaldehyde environmental contamination phenomena and explore possible associations between variables. It was considered a sample of 10 hospital pathology laboratories, assessed exposure of three professional groups for comparison with two exposure metrics, and also knows ceiling concentrations in 83 activities. Were applied, simultaneously, two different environmental assessment methods: one method (Method 1) using direct reading equipment that perform measure by Photo Ionization Detection, with 11,7 eV lamps and, simultaneously, make activity description and film. This method provided data for ceiling concentrations for each activity study (TLV-C). In the other applied method (Method 2), air sampling and formaldehyde analysis were performed according to NIOSH method (2541). This method provided data average exposure concentration (TLV-TWA). Measuring and sampling strategies of each methods and exposure groups definition (Technicians, Pathologists and Assistants) was possible by information provided by activities (ergonomic) analysis. Several independent variables were studied, including temperature and relative humidity, formaldehyde solution used, ventilation conditions, and also anatomic pieces mean value processed per day in each laboratory. To register information about these variables was completed an Observation and Registration Grid. Three environmental contamination indicators were selected has dependent variables namely: mean value from concentrations exceeding 0,3 ppm in each laboratory, weighted average concentration obtained for each exposure group, as well each laboratory Time Regeneration Index. These indicators were calculated and determined through data obtained by the two environmental assessment methods. Based on Queensland University proposal, was also applied a methodology for assessing nasopharyngeal cancer risk in 83 activities studied in order to obtain risk levels (semi-quantitative estimation). For Severity level was considered available information in scientific literature that defines biological adverse events related to the chemical agent action mode, and associated with environment formaldehyde concentrations. For Probability level was used information provided by (ergonomic) work analysis that helped identifies activity frequency. Environmental assessment methods provide different results, but not contradictory, regarding formaldehyde occupational exposure evaluation. In the studied activities (n=83), about 93% of the values were above exposure limit value set for ceiling concentration in Portugal (VLE-CM = 0,3 ppm). "Macroscopic exam" was the most studied activity, and obtained the higher prevalence of results superior than 0,3 ppm (92,8%). The highest ceiling concentration mean value (2,04 ppm) was obtain in Technicians exposure group, but a result wider range was observed in Pathologists group (0,21 ppm to 5,02 ppm). Concerning Method 2, results from the three exposure groups, were all lower than limit value set by Occupational Safety and Health Administration (TLV-TWA=0,75ppm). There was a statistically significant association between anatomic pieces mean value processed by each laboratory per day, and two of the three environmental contamination indicators used, namely average concentrations exceeding 0,3 ppm (p=0,009) and Time Regeneration Index (p=0,001). Temperature was not statistically associated with any environmental contamination used indicators. Relative humidity had a statistically significant association only with one environmental contamination indicator, namely weighted average concentration, particularly with Pathologists group (p=0,02) and Technicians group (p=0,04). Risk assessment performed in the 83 studied activities showed that around two thirds (35%) were classified as (at least) high, and also noted that 70% of laboratories had at least 1 activity with high risk rating. The two environmental assessment methods application, as well information obtained from two exposure metrics, allowed to conclude that most appropriate exposure metric is ceiling concentration, because is associated with formaldehyde action mode. Moreover, an environmental method, like Method 1, which allows study formaldehyde concentrations and relates them with activity, provides relevant information for preventive information, since identifies the activity with higher exposure, as well variables that promote exposure. Anatomic pieces represent formaldehyde contamination main source in this occupational setting, and this is of particular interest because all activities are focused on anatomic pieces processing. Since there is no prospect, in short term, for formaldehyde use elimination due to large number of activities that still involve solution use, it can be concluded that exposure to this agent, in this particular occupational setting, is preoccupant, requiring an rapid intervention in order to minimize exposure and prevent potential health effects in exposed workers.
Resumo:
Tendo em consideração o estado de degradação do parque habitacional nacional é necessário promover a sua regeneração dado o efeito nocivo com que este se repercute na nossa sociedade. É de referir a existência em Portugal de uma cultura reativa, por vezes tardia, de resolução de problemas dos edifícios, devendo-se, de certo modo, à existência de uma legislação generalista e claramente insuficiente, de uma fiscalização inoperante e à inexistência, durante décadas, de políticas de incentivo à manutenção. Torna-se imperativo a necessidade da implementação de medidas preventivas que evitem o aparecimento do mesmo cenário de deterioração. A presente dissertação insere-se no âmbito da reabilitação de edifícios pelo facto de esta atividade ter uma importância fundamental no desempenho do parque edificado, o que reflete a situação socioeconómica do país e no desenvolvimento sustentável das sociedades. Neste contexto, desenvolve-se o objeto de investigação deste trabalho, que se relaciona com manifestações patológicas de edifícios antigos da baixa portuense, procurando o estudo de fenómenos anómalos ao nível das fachadas das edificações. A reabilitação surge como uma medida possível e desejável de correcção das anomalias que se verificam na generalidade dos edifícios, principalmente nos mais antigos. O processo de reabilitação no presente tempo deve ser realizado de forma sustentável, de modo a minimizar desperdícios de recursos, custos e proporcionar o máximo bem-estar aos utilizadores. O estudo destes fenómenos desenvolve-se para a recuperação das fachadas ao seu estado inicial, procurando enquadrar e incentivar para uma posterior estratégia de manutenção condicionada, baseada em inspeções e numa perspetiva preventiva de atuação, ou seja, intervindo na origem dos problemas e evitando o seu desenvolvimento, com o objetivo principal de otimizar a vida útil e os custos diferidos dos respetivos edifícios.
Resumo:
O instável mas tendencialmente crescente preço dos combustíveis associado a preocupações ambientais cada vez mais enraizadas nas sociedades, têm vindo a despoletar uma maior atenção à procura de combustíveis alternativos. Por outro lado, várias projecções indicam um aumento muito acentuado do consumo energético global no curto prazo, fruto do aumento da população e do nível de industrialização das sociedades. Neste contexto, o biodiesel (ésteres de ácidos gordos) obtido através da transesterificação de triglicerídeos de origem vegetal ou animal, surge como a alternativa “verde” mais viável para utilização em equipamentos de combustão. A reacção de transesterificação é catalisada, por norma com recurso a catalisadores homogéneos alcalinos (NaOH ou KOH). Este tipo de processo, o único actualmente com expressão a nível industrial, apresenta algumas desvantagens que, para além de aumentarem o custo do produto final, contribuem para reduzir a benignidade do mesmo: a impossibilidade de reutilização do catalisador, o aumento do número e complexidade das etapas de separação e a produção de efluentes resultantes das referidas etapas. Com o intuito de minimizar ou eliminar estes problemas, vários catalisadores heterogéneos têm vindo a ser estudados para esta reacção. Apesar de muitos apresentarem resultados promissores, a grande maioria não tem viabilidade para aplicação industrial seja devido ao seu próprio custo, seja devido aos pré-tratamentos necessários à sua utilização. Entre estes catalisadores, o óxido de cálcio é talvez o que apresenta resultados mais promissores. O crescente número de estudos envolvendo este catalisador em detrimento de outros, é por si mesmo prova do potencial do CaO. A realização deste trabalho pretendia atingir os seguintes objectivos principais: • Avaliar a elegibilidade do óxido de cálcio enquanto catalisador da reacção de transesterificação de óleos alimentares usados com metanol; • Avaliar qual a sua influência nas características dos produtos finais; • Avaliar as diferenças de performance entre o óxido de cálcio activado em atmosfera inerte (N2) e em ar, enquanto catalisadores da reacção de transesterificação de óleos alimentares usados com metanol; • Optimizar as condições da reacção com recurso às ferramentas matemáticas disponibilizadas pelo planeamento factorial, através da variação de quatro factores chave de influência: temperatura, tempo, relação metanol / óleo e massa de catalisador utilizado. O CaO utlizado foi obtido a partir de carbonato de cálcio calcinado numa mufla a 750 °C durante 3 h. Foi posteriormente activado a 900 °C durante 2h, em atmosferas diferentes: azoto (CaO-N2) e ar (CaO-Ar). Avaliaram-se algumas propriedades dos catalisadores assim preparados, força básica, concentração de centros activos e áreas específicas, tendo-se obtido uma força básica situada entre 12 e 14 para ambos os catalisadores, uma concentração de centros activos de 0,0698 mmol/g e 0,0629 mmol/g e áreas específicas de 10 m2/g e 11 m2/g respectivamente para o CaO-N2 e CaO-Ar. Efectuou-se a transesterificação, com catálise homogénea, da mistura de óleos usados utilizada neste trabalho com o objectivo de determinar os limites para o teor de FAME’s (abreviatura do Inglês de Fatty Acid Methyl Esters’) que se poderiam obter. Foi este o parâmetro avaliado em cada uma das amostras obtidas por catálise heterogénea. Os planos factoriais realizados tiveram como objectivo maximizar a sua quantidade recorrendo à relação ideal entre tempo de reacção, temperatura, massa de catalisador e quantidade de metanol. Verificou-se que o valor máximo de FAME’s obtidos a partir deste óleo estava situado ligeiramente acima dos 95 % (m/m). Realizaram-se três planos factoriais com cada um dos catalisadores de CaO até à obtenção das condições óptimas para a reacção. Não se verificou influência significativa da relação entre a quantidade de metanol e a massa de óleo na gama de valores estudada, pelo que se fixou o valor deste factor em 35 ml de metanol / 85g de óleo (relação molar aproximada de 8:1). Verificou-se a elegibilidade do CaO enquanto catalisador para a reacção estudada, não se tendo observado diferenças significativas entre a performance do CaO-N2 e do CaO-Ar. Identificaram-se as condições óptimas para a reacção como sendo os valores de 59 °C para a temperatura, 3h para o tempo e 1,4 % de massa de catalisador relativamente à massa de óleo. Nas referidas condições, obtiveram-se produtos com um teor de FAME’s de 95,7 % na catálise com CaO-N2 e 95,3 % na catálise com CaO-Ar. Alguns autores de estudos consultados no desenvolvimento do presente trabalho, referiam como principal problema da utilização do CaO, a lixiviação de cálcio para os produtos obtidos. Este facto foi confirmado no presente trabalho e na tentativa de o contornar, tentou-se promover a carbonatação do cálcio com a passagem de ar comprimido através dos produtos e subsequente filtração. Após a realização deste tratamento, não mais se observaram alterações nas suas propriedades (aparecimento de turvação ou precipitados), no entanto, nos produtos obtidos nas condições óptimas, a concentração de cálcio determinada foi de 527 mg/kg no produto da reacção catalisada com CaO-N2 e 475 mg/kg com CaO-A. O óxido de cálcio apresentou-se como um excelente catalisador na transesterificação da mistura de óleos alimentares usados utilizada no presente trabalho, apresentando uma performance ao nível da obtida por catálise homogénea básica. Não se observaram diferenças significativas de performance entre o CaO-N2 e o CaO-Ar, sendo possível obter nas mesmas condições reaccionais produtos com teores de FAME’s superiores a 95 % utilizando qualquer um deles como catalisador. O elevado teor de cálcio lixiviado observado nos produtos, apresenta-se como o principal obstáculo à aplicação a nível industrial do óxido de cálcio como catalisador para a transesterificação de óleos.
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção de Grau de Mestre em Engenharia Biomédica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Civil,Perfil de Construção
Resumo:
Inaugurada em 1895 junto a Elvas, a Colónia Agrícola Correcional de Vila Fernando procurava a regeneração de jovens por meio do trabalho, buscando também acabar com as péssimas condições a que estavam sujeitos os jovens ao serem encarcerados com os adultos, nas cadeias do país. Analisaremos, no período compreendido entre finais do século XIX e início do século XX, os diferentes processos educativos presentes no quotidiano da instituição, nas práticas do trabalho, da formação profissional e do ensino escolar, procurando averiguar, numa perspetiva histórico-pedagógica, de que modo a instituição foi capaz de conciliar o carácter disciplinador do trabalho com a reintegração social.
Resumo:
Tese apresentada à Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Genética Molecular e Biomedicina
Resumo:
Enquadrado num contexto cada vez mais marcado pela necessidade imperiosa de adoção e desenvolvimento de práticas ambientais e energeticamente sustentáveis, este trabalho visa contribuir para a caracterização e otimização do consumo de energia na produção de biodiesel. O biodiesel pode ser encarado como uma boa resposta aos graves problemas que os combustíveis fósseis estão a provocar nas sociedades modernas, pois é uma fonte de energia biodegradável, não-tóxica e sintetizada a partir de várias matérias-primas. Porém, o elevado custo de produção, como consequência do elevado preço das matérias-primas, constitui o maior problema para a sua implementação e comercialização a grande escala. A produção de biodiesel é, em sua quase totalidade, conduzida por via de reação de transesterificação, usando óleo vegetal e álcool como matérias-primas. O objetivo geral deste trabalho é otimizar energeticamente um processo de produção de biodiesel, via catálise homogênea alcalina (BCHA). Para alcançar esse objetivo, um fluxograma típico de produção foi construído e analisado, tanto do ponto de vista energético como econômico. Posteriormente oportunidades de otimização do processo foram identificadas, no sentido de reduzir o consumo de utilidades, impacto ambiental e aumentar a rentabilidade econômica. A construção do processo, a caracterização da alimentação, os critérios de operacionalidade, a obtenção de resultados e demais fatores foram efetuados com auxílio de um software de simulação Aspen Plus versão 20.0 criado pela Aspen Technology products. Os resultados do trabalho revelaram que o processo BCHA produz uma corrente com 99,9 % em biodiesel, obedecendo às normas internacionais em vigor. Na parte energética, o processo BCHA base necessitou de 21.405,1 kW em utilidades quentes e 14.886,3 kW em utilidades frias. A integração energética do processo BCHA, segundo a metodologia pinch, permitiu uma redução das necessidades quentes para 10.752,3 kW (redução de 50 %) e frias para 4.233,5 kW (redução de 72 %). A temperatura no ponto de estrangulamento (PE) foi de 157,7 ºC nas correntes quentes e 147,7 ºC nas correntes frias. Em termos econômicos, o custo total é reduzido em 35% com a integração energética proposta. Essa diminuição, deve-se sobretudo à redução do custo operacional, onde as necessidades de vapor de muita alta pressão (VMAP), vapor de alta pressão (VAP) e água de resfriamento (AR) apresentaram quebras de 2 %, 92 % e 71 %, respectivamente. Como conclusão final, salienta-se que a integração do processo BCHA estudado é energética e economicamente viável.