973 resultados para Open Channel Flow Controls


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was the development of miniaturized structures useful for retention and/or selection of particles and viscous substances from a liquid flow. The proposed low costs structures are similar to macroscopic wastewater treatment systems, named baffles, and allow disassemble. They were simulated using FEMLAB 3.2b package and manufactured in acrylic with conventional tools. Tests for retention or selection of particles in water or air and viscous fluids in water were carried out. Either in air or water particles with 50 mu m diameter will be retained but not with 13 mu m diameter. In aqueous flow, it is also possible the retention of viscous samples, such as silicone 350 cSt. The simulated results showed good agreement with experimental measurements. These miniaturized structures can be useful in sample pretreatment for chemical analysis and microorganism manipulation. (C) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work aims at proposing the use of the evolutionary computation methodology in order to jointly solve the multiuser channel estimation (MuChE) and detection problems at its maximum-likelihood, both related to the direct sequence code division multiple access (DS/CDMA). The effectiveness of the proposed heuristic approach is proven by comparing performance and complexity merit figures with that obtained by traditional methods found in literature. Simulation results considering genetic algorithm (GA) applied to multipath, DS/CDMA and MuChE and multi-user detection (MuD) show that the proposed genetic algorithm multi-user channel estimation (GAMuChE) yields a normalized mean square error estimation (nMSE) inferior to 11%, under slowly varying multipath fading channels, large range of Doppler frequencies and medium system load, it exhibits lower complexity when compared to both maximum likelihood multi-user channel estimation (MLMuChE) and gradient descent method (GrdDsc). A near-optimum multi-user detector (MuD) based on the genetic algorithm (GAMuD), also proposed in this work, provides a significant reduction in the computational complexity when compared to the optimum multi-user detector (OMuD). In addition, the complexity of the GAMuChE and GAMuD algorithms were (jointly) analyzed in terms of number of operations necessary to reach the convergence, and compared to other jointly MuChE and MuD strategies. The joint GAMuChE-GAMuD scheme can be regarded as a promising alternative for implementing third-generation (3G) and fourth-generation (4G) wireless systems in the near future. Copyright (C) 2010 John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new digital computer mock circulatory system has been developed in order to replicate the physiologic and pathophysiologic characteristics of the human cardiovascular system. The computer performs the acquisition of pressure, flow, and temperature in an open loop system. A computer program has been developed in Labview programing environment to evaluate all these physical parameters. The acquisition system was composed of pressure, flow, and temperature sensors and also signal conditioning modules. In this study, some results of flow, cardiac frequencies, pressures, and temperature were evaluated according to physiologic ventricular states. The results were compared with literature data. In further works, performance investigations will be conducted on a ventricular assist device and endoprosthesis. Also, this device should allow for evaluation of several kinds of vascular diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents results of preliminary studies concerning application of magnetic bearing in a ventricular assist device (VAD) being developed by Dante Pazzanese Institute of Cardiology-IDPC (Sao Paulo, Brazil). The VAD-IDPC has a novel architecture that distinguishes from other known VADs. In this, the rotor has a conical geometry with spiral impellers, showing characteristics that are intermediate between a centrifugal VAD and an axial VAD. The effectiveness of this new type of blood pumping principle was showed by tests and by using it in heart surgery for external blood circulation. However, the developed VAD uses a combination of ball bearings and mechanical seals, limiting the life for some 10 h, making impossible its long-term use or its use as an implantable VAD. As a part of development of an implantable VAD, this work aims at the replacement of ball bearings by a magnetic bearing. The most important magnetic bearing principles are studied and the magnetic bearing developed by Escola Politecnica of Sao Paulo University (EPUSP-MB) is elected because of its very simple architecture. Besides presenting the principle of the EPUSP-MB, this work presents one possible alternative for applying the EPUSP-MB in the IDPC-VAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work studies the operation of source-follower buffers implemented with standard and graded-channel (GC) fully depleted (FD) SCI nMOSFETs at low temperatures. The analysis is performed by comparing the voltage gain of buffers implemented with GC and standard SOI nMOS transistors considering devices with the same mask channel length and same effective channel length. It is shown that the use of GC devices allows for achieving improved gain in all inversion levels in a wide range of temperatures. In addition, this improvement increases as temperature is reduced. It is shown that GC transistors can provide virtually constant gain, while for standard devices, the gain departs from the maximum value depending on the temperature and inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to study the reasons for the enhanced gain of GC MOSFETs at low temperatures. (C) 2009 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a rheological investigation of pure gypsum (PG) and a commercial gypsum-lime-filler plaster (CP) using the modified Vicat apparatus and squeeze flow method. The samples were tested at several different intervals after manual or mechanical mixing. The results confirmed squeeze flow to be more sensitive in determining fresh paste behavior than the modified Vicat apparatus. PG set faster when prepared in mechanical mixer than when manually mixed. Conversely, the CP composition presented longer setting when mixed mechanically. The study also included the analysis of two ready-to-use polymer-based products for leveling and rendering (drywall joint compound - DJC; acrylic putty - AP) measured by squeeze flow and compared to the commercial composition. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work the performance of graded-channel (CC) SOI MOSFETs operating as source-follower buffers is presented. The experimental analysis is performed by comparing the gain and linearity of buffers implemented with CC and standard SOI MOS devices considering the same mask dimensions. It is shown that by using CC devices, buffer gain very close to the theoretical limit can be achieved, with improved linearity, while for standard devices the gain departs from the theoretical value depending on the inversion level imposed by the bias current and input voltage. Two-dimensional numerical simulations were performed in order to confirm some hypotheses proposed to explain the gain behavior observed in the experimental data. By using numerical simulations the channel length has been varied, showing that the gain of buffers implemented with CC devices remains close to the theoretical limit even when short-channel devices are adopted. It has also been shown that the length of a source-follower buffer using CC devices can be reduced by a factor of 5, in comparison with a standard Sol MOSFET, without gain loss or linearity degradation. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work we present an analysis of harmonic distortion (HD) in graded-channel (GC) gate-all-a round (GAA) devices operating in saturation region for analog applications. The study has been performed through device characterization and two-dimensional process and device simulations. The overall study has been done on the total and third order HDs. When applied in the saturation regime as an amplifier, the GC outperforms conventional GAA transistors presenting simultaneously higher transconductance, lower drain output conductance and more than 15 dB improved linearity. The influence of channel length reduction on the H D is also analyzed. Although slight linearity degradation is observed in both the conventional and the GC devices when reducing the channel length, the HD presented by the GC transistor is significantly lower than the one showed by conventional device for any Studied channel length. This allows AC input signal amplitude up to 20 times higher than the conventional GAA for a same specified distortion level. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Riparian forests are important for the structure and functioning of stream ecosystems, providing structural components such as large woody debris (LWD). Changes in these forests will cause modifications in the LWD input to streams, affecting their structure. In order to assess the influence of riparian forests changes in LWD supply, 15 catchments (third and fourth order) with riparian forests at different conservation levels were selected for sampling. In each catchment we quantified the abundance, volume and diameter of LWD in stream channels; the number, area and volume of pools formed by LWD and basal area and tree diameter of riparian forest. We found that riparian forests were at a secondary successional stage with predominantly young trees (diameter at breast height < 10 cm) in all studied streams. Results showed that basal area and diameter of riparian forest differed between the stream groups (forested and non-forested), but tree density did not differ between groups. Differences were also observed in LWD abundance, volume, frequency of LWD pools with subunits and area and volume of LWD pools. LWD diameter, LWD that form pools diameter and frequency of LWD pools without subunits did not differ between stream groups. Regression analyses showed that LWD abundance and volume, and frequency of LWD pools (with and without subunits) were positively related with the proportion of riparian forest. LWD diameter was not correlated to riparian tree diameter. The frequency of LWD pools was correlated to the abundance and volume of LWD, but characteristics of these pools (area and volume) were not correlated to the diameter of LWD that formed the pools. These results show that alterations in riparian forest cause modifications in the LWD abundance and volume in the stream channel, affecting mainly the structural complexity of these ecosystems (reduction in the number and structural characteristics of LWD pools). Our results also demonstrate that riparian forest conservation actions must consider not only its extension, but also successional stage to guarantee the quantity and quality of LWD necessary to enable the structuring of stream channels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Due to the rapid depletion of water resources, water must be used more efficiently in agriculture to maintain current levels of yield in irrigated areas. The efficiency of irrigation systems can be increased by adjusting the amount of water applied to specific conditions of soil and crop, which may vary in a field. Taking into account spatial and temporal variability, it is evident that an equipment capable of providing different irrigation levels is necessary to meet the water requirement of the soil. This work aims to develop and evaluate a flow rate sprinkler to be used in center pivots or linear moving irrigation systems, with potential for utilization in irrigation scheduling. A prototype was developed by duplicating its calibrations, and discharge coefficient adjustment was carried out in the laboratory. To predict the flow rate, a successful model that represented the operation of the flow rate sprinkler was established. The calibration of the flow rate sprinkler prototype showed satisfactory statistical and technical results. Automation of the prototype was achieved by driving a step motor using communication from the parallel port of a microcomputer, which was controlled by a software developed for this purpose. The results were satisfactory and technically feasible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bulk milk was collected from 100 farms throughout the year and analysed after storage for either 24, 48 or 72 h, using flow cytometry. The total bacterial counts obtained by two methods - flow cytometry and standard plate count were compared and the conversion relationship between them was assessed: the results showed no effect of the age of the samples relationship between these two methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides insights into liquid free water dynamics in wood vessels based on Lattice Boltzmann experiments. The anatomy of real wood samples was reconstructed from systematic 3-D analyses of the vessel contours derived from successive microscopic images. This virtual vascular system was then used to supply fluid-solid boundary conditions to a two-phase Lattice Boltzmann scheme and investigate capillary invasion of this hydrophilic porous medium. Behavior of the liquid phase was strongly dependent on anatomical features, especially vessel bifurcations and reconnections. Various parameters were examined in numerical experiments with ideal vessel bifurcations, to clarify our interpretation of these features. (c) 2010 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

P>Background: We aimed to evaluate the ascorbic acid concentration in secondary aqueous humour (AH) from glaucomatous patients and to compare it with primary AH from primary open-angle glaucoma patients and non-glaucomatous patients. Methods: Primary AH samples were prospectively obtained from clinically uncontrolled primary open-angle glaucoma patients and senile cataract patients (controls) prior to trabeculectomy and cataract surgery. Secondary AH samples were obtained from eyes with previous intraocular surgery, prior to trabeculectomy or cataract surgery. AH (0.1 mL) was aspirated by inserting a 26-gauge needle into the anterior chamber just before surgery and then immediately stored at -80 degrees C. The ascorbic acid concentration was determined in a masked fashion by high-pressure liquid chromatography. Results: A total of 18 patients with senile cataract, 16 glaucomatous patients with primary AH (no previous intraocular surgery) and 11 glaucomatous patients with secondary AH (previous intraocular surgery) were included. There was no difference in mean age between groups (P = 0.15). The mean +/- standard deviation concentration of ascorbic acid in the secondary AH from glaucomatous patients (504 +/- 213 mu mol/L [95% confidence interval {CI}, 383-624]) was significantly lower than the concentration of ascorbic acid found in the primary aqueous of primary open-angle glaucoma (919 +/- 427 mu mol/L [95% CI, 709-1128]) and control patients (1049 +/- 433 mu mol/L [95% CI, 848-1249]; P < 0.01, Kruskal-Wallis test). Conclusions: The ascorbic acid concentration in secondary AH of glaucomatous patients was approximately twofold lower in comparison with primary AH of glaucomatous and cataract patients. The implications of a reduced concentration of ascorbic acid in the secondary AH deserve further investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Tramadol is a well tolerated and effective analgesic used to treat moderate to severe pain. Several generic formulations of tramadol are available in Brazil; however, published information regarding their bioequivalence in the Brazilian population is not available. A study was designed for Brazilian regulatory authorities to allow marketing of a generic formulation. Objective: The purpose of this study was to compare the bioequivalence of 2 commercial tablet preparations containing tramadol 100 mg marketed for use in Brazil. Methods: A randomized, open-label, 2 x 2 crossover study was performed in healthy Brazilian volunteers under fasting conditions with a washout period of 12 days. Two tablet formulations of tramadol 100 mg (test and reference formulations) were administered as a single oral dose, and blood samples were collected over 24 hours. Tramadol plasma concentrations were quantified using a validated HPLC method. A plasma concentration time profile was generated for each volunteer and then mean values were determined, from which C(max), T(max), AUC(0-t), AUC(0-infinity), k(e), and t(1/2) were calculated using a noncompartmental model. Bioequivalence between the products was determined by calculating 90% CIs for the ratios of C(max), AUC(0-t), and AUC(0-infinity) values for the test and reference products using log-transformed data. Tolerability was assessed by monitoring vital signs (temperature, blood pressure, heart rate), laboratory tests (hematology, blood biochemistry, hepatic function, urinalysis), and interviews with the volunteers before medication administration and every 2 hours during the study. Results: Twenty-six healthy volunteers (13 men, 13 women) were enrolled in and completed the study. Mean (SD) age was 30 (6.8) years (range, 21-44 years), mean weight was 64 (8.3) kg (range, 53-79 kg), and mean height was 166 (6.4) cm (range, 155-178 cm). The 90% CIs for the ratios of C(max) (1.01-1.17), AUC(0-t) (1.00-1.13), and AUC(0-infinity) (1.00-1.14) values for the test and reference products fell within the interval of 0.80 to 1.25 proposed by most regulatory agencies, including the Brazilian regulatory body. No clinically important adverse effects were reported; only mild somnolence was reported by 4 volunteers and mild headaches by 5 volunteers, and there was no need to use medication to treat these symptoms. Conclusion: Pharmacokinetic analysis in these healthy Brazilian volunteers suggested that the test and reference formulations of tramadol 100-mg tablets met the regulatory requirements to assume bio-equivalence based on the Brazilian regulatory definition. (Clin Ther 2010;32:758-765) (C) 2010 Excerpta Medica Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Zidovudine is a thymidine nucleoside reverse transcriptase inhibitor with activity against HIV type 1. Some (similar to 8) generic formulations of zidovudine are available in Brazil; however, based on a literature search, information concerning their bioavailability and pharmacokinetic properties in the Brazilian population has not been reported. Objective: The aim of this study was to compare the bioavailability and pharmacokinetic properties of 2 capsule formulations of zidovudine 100 mg in healthy Brazilian volunteers. Methods: This open-label, randomized, 2-way crossover study utilized a 1-week washout period between doses. Blood samples were collected for 8 hours after a single dose of zidovudine 100-mg test (Zidovudina, Fundaqdo para o Remedio Popular, Sao Paulo, Brazil) or reference formulation (Retrovir (R), GlaxoSmithKline, Philadelphia, Pennsylvania). Plasma zidovudine concentrations were determined using a validated high-performance liquid chromatography method with ultraviolet detection at 265 nm. C-max, T-max, AUC(0-t), AUC(0-infinity), t(1/2), and the elimination constant (k(e)) were determined using noncompartmental analysis. The formulations were considered bioequivalent if the 90% CIS for C-max, AUC(0-t), and AUC(0-infinity) fell within the interval of 80 % to 125 %, the regulatory definition set by the US Food and Drug Administration (FDA). Results: Twenty-four healthy volunteers (12 males, 12 females; mean age, 27 years; weight, 60 kg; height, 167 cm) were enrolled and completed the study. The 90% CIs of the treatment ratios for the logarithmic-transformed values of C-max, AUC(0-t), and AUC(0-infinity) were 80.0% to 113.6%, 93.9% to 109.7%, and 93.6% to 110.1 %, respectively. The values for the test and reference formulations were within the FDA bioequivalence definition intervals of 80% to 125%. Conclusions: In this small study in healthy subjects, no statistically significant differences in C-max, AUC(0-t), and AUC(0-)infinity were found between the test and reference formulations of zidovudine 100-mg capsules. The 90% CIs for the mean ratio values for the test and reference formulations of AUC(0-t), AUC(0-infinity), and C-max indicated that the reported data were entirely within the bioequivalence acceptance range proposed by the FDA of 80% to 125% (using log-transformed data).