Bioequivalence and pharmacokinetics of two zidovudine formulations in healthy Brazilian volunteers: An open-label, randomized, single-dose, two-way crossover study
Contribuinte(s) |
UNIVERSIDADE DE SÃO PAULO |
---|---|
Data(s) |
19/10/2012
19/10/2012
2008
|
Resumo |
Background: Zidovudine is a thymidine nucleoside reverse transcriptase inhibitor with activity against HIV type 1. Some (similar to 8) generic formulations of zidovudine are available in Brazil; however, based on a literature search, information concerning their bioavailability and pharmacokinetic properties in the Brazilian population has not been reported. Objective: The aim of this study was to compare the bioavailability and pharmacokinetic properties of 2 capsule formulations of zidovudine 100 mg in healthy Brazilian volunteers. Methods: This open-label, randomized, 2-way crossover study utilized a 1-week washout period between doses. Blood samples were collected for 8 hours after a single dose of zidovudine 100-mg test (Zidovudina, Fundaqdo para o Remedio Popular, Sao Paulo, Brazil) or reference formulation (Retrovir (R), GlaxoSmithKline, Philadelphia, Pennsylvania). Plasma zidovudine concentrations were determined using a validated high-performance liquid chromatography method with ultraviolet detection at 265 nm. C-max, T-max, AUC(0-t), AUC(0-infinity), t(1/2), and the elimination constant (k(e)) were determined using noncompartmental analysis. The formulations were considered bioequivalent if the 90% CIS for C-max, AUC(0-t), and AUC(0-infinity) fell within the interval of 80 % to 125 %, the regulatory definition set by the US Food and Drug Administration (FDA). Results: Twenty-four healthy volunteers (12 males, 12 females; mean age, 27 years; weight, 60 kg; height, 167 cm) were enrolled and completed the study. The 90% CIs of the treatment ratios for the logarithmic-transformed values of C-max, AUC(0-t), and AUC(0-infinity) were 80.0% to 113.6%, 93.9% to 109.7%, and 93.6% to 110.1 %, respectively. The values for the test and reference formulations were within the FDA bioequivalence definition intervals of 80% to 125%. Conclusions: In this small study in healthy subjects, no statistically significant differences in C-max, AUC(0-t), and AUC(0-)infinity were found between the test and reference formulations of zidovudine 100-mg capsules. The 90% CIs for the mean ratio values for the test and reference formulations of AUC(0-t), AUC(0-infinity), and C-max indicated that the reported data were entirely within the bioequivalence acceptance range proposed by the FDA of 80% to 125% (using log-transformed data). |
Identificador |
CLINICAL THERAPEUTICS, v.30, n.5, p.902-908, 2008 0149-2918 http://producao.usp.br/handle/BDPI/19890 10.1016/j.clinthera.2008.05.003 |
Idioma(s) |
eng |
Publicador |
ELSEVIER |
Relação |
Clinical Therapeutics |
Direitos |
restrictedAccess Copyright ELSEVIER |
Palavras-Chave | #zidovudine #bioequivalence #pharmacokinetic #human plasma #high-performance liquid chromatography #LAMIVUDINE #TABLET #DRUGS #BIOAVAILABILITY #ABSORPTION #THERAPY #ACCESS #MEAL #FOOD #AIDS #Pharmacology & Pharmacy |
Tipo |
article original article publishedVersion |