967 resultados para Analytical performance
Resumo:
Poly(pyrrole) (PPY) coating was prepared on a stainless-steel (SS) wire for solid-phase microextraction (SPME) by electrochemical deposition (cyclic voltammetric). The PPY was evaluated by analyzing new-generation antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine, and sertraline) in plasma sample by SPME and liquid chromatography with UV detection (LC-UV). The effect of electrolyte Solution (lithium perchlorate or tetrabutylammonium perchlorate) and the number of cycles (50, 100 or 200) applied during the polymerization process on the SPME performance was evaluated. Important factors in the optimization of SPME efficiency such as extraction time, temperature, pH, influence of plasma proteins on sorption mechanisms, and desorption conditions are discussed. The SPME-PPY/LC method showed to be linear in concentrations ranging from the limit of quantification (LOQ) to 1200 ng mL(-1). The LOQ values range from 16 to 25 ng mL-1. The inter-day precision of the SPME-PPY/LC method presented coefficient of variation (CV) lower than 15%. Based on analytical validation results, the SPME-PPY/LC methodology showed to be adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the SPME-PPY/LC method was applied to the analysis of plasma samples from elderly depressed patients. (c) 2009 Elsevier B.V. All rights reserved,
Resumo:
Larval quality may be capable of explaining much of the variation in the recruitment and subsequent population dynamics of benthic marine invertebrates. Whilst the effects of larval nutritional condition on adult performance have received the most attention, recent work has shown that larval size may also be an important and ubiquitous source of variation in larval quality. We examined the effects of variation in larval size on the post-metamorphic survival and growth of Watersipora subtorquata in 2 very different habitats - experimental substrata and pier pilings. We found strong effects of larval size on colony performance, although these varied among experiments. For colonies on experimental substrata, larval size positively affected adult survival and, initially, growth. However, after 3 wk in the field, there was no relationship between larval size and colony size, possibly because colonies were completely surrounded by newly settled organisms. Larval size also positively affected post-metamorphic growth of colonies on pier pilings, but, surprisingly, colonies that came from larger larvae had lower survival than colonies from smaller larvae. Overall, variation in larval size will strongly affect the recruitment and subsequent performance of adults in this species, although this may vary among different habitats. This study highlights the importance of examining the effects of larval quality on adult performance in as realistic conditions as possible, because of the strong interaction between larval size effects and the environment.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high-performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of carbamazepine, carbamazepine-10,11-epoxide, phenytoin and phenobarbital in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. Important factors in the optimization of SBSE efficiency such as pH, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) assured recoveries ranging from 72 to 86%, except for phenytoin (62%). Separation was obtained using a reverse phase C-18 column with UV detection (210 nm). The mobile phase consisted of water: acetonitrile (78:22, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.08-40.0 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125-40.0 mu g mL(-1) for phenytoin, The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.0, 4.0 and 20.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 8.8% and all inter-CVs were less than 10%. Limits of quantification were 0.08 mu g mL(-1) for carbamazepine, carbamazepine-10,11-epoxide and phenobarbital and 0.125 mu g mL(-1) for phenytoin. No interference of the drugs normally associated with antiepileptic drugs was observed. Based on figures of merit results, the SBSE/HPLC-UV proved adequate for antiepileptic drugs analyses from therapeutic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (c) 2008 Elsevier B.V. All rights reserved.
Resumo:
Recent advances in the control of molecular engineering architectures have allowed unprecedented ability of molecular recognition in biosensing, with a promising impact for clinical diagnosis and environment control. The availability of large amounts of data from electrical, optical, or electrochemical measurements requires, however, sophisticated data treatment in order to optimize sensing performance. In this study, we show how an information visualization system based on projections, referred to as Projection Explorer (PEx), can be used to achieve high performance for biosensors made with nanostructured films containing immobilized antigens. As a proof of concept, various visualizations were obtained with impedance spectroscopy data from an array of sensors whose electrical response could be specific toward a given antibody (analyte) owing to molecular recognition processes. In addition to discussing the distinct methods for projection and normalization of the data, we demonstrate that an excellent distinction can be made between real samples tested positive for Chagas disease and Leishmaniasis, which could not be achieved with conventional statistical methods. Such high performance probably arose from the possibility of treating the data in the whole frequency range. Through a systematic analysis, it was inferred that Sammon`s mapping with standardization to normalize the data gives the best results, where distinction could be made of blood serum samples containing 10(-7) mg/mL of the antibody. The method inherent in PEx and the procedures for analyzing the impedance data are entirely generic and can be extended to optimize any type of sensor or biosensor.
Resumo:
This paper describes the use of the electrostatic layer-by-layer (LbL) technique for the preparation of bioanodes with potential application in ethanol/O(2) biofuel cells. More specifically, the LbL technique was employed for immobilization of dehydrogenase enzymes and polyamidoamine (PAMAM) dendrimers onto carbon paper support. Both mono (anchoring only the enzyme alcohol dehydrogenase, ADH) and bienzymatic (anchoring both ADH and aldehyde dehydrogenase, AldDH) systems were tested. The amount of ADH deposited onto the Toray (R) paper was 95 ng cm(-2) per bilayer. Kinetic studies revealed that the LbL technique enables better control of enzyme disposition on the bioanode, as compared with the results obtained with the bioanodes prepared by the passive adsorption technique. The power density values achieved for the mono-enzymatic system as a function of the enzyme load ranged from 0.02 to 0.063 mW cm(-2) for the bioanode containing 36 ADH bilayers. The bioanodes containing a gas diffusion layer (GDL) displayed enhanced performance, but their mechanical stability must be improved. The bienzymatic system generated a power density of 0.12 mW cm(-2). In conclusion, the LbL technique is a very attractive approach for enzyme immobilization onto carbon platform, since it enables strict control of enzyme disposition on the bioanode surface with very low enzyme consumption. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and reproducible method by microextraction packed sorbent and liquid chromatography with UV detection (MEPS/LC-UV) is described for the determination of new generation antidepressants (sertraline, mirtazapine, fluoxetine, citalopram and paroxetine) in human plasma samples. The MEPS variables, such as sample volume, pH, number of extraction cycles (draw-eject), and desorption conditions (solvent and solvent volume of elution) influenced the MEPS/LC efficiency significantly. Important factors in the optimization of MEPS efficiency, as well as washing steps and carryover effect are discussed. The analyses were carried out using small sample volumes (400 mu L.), and in a short time period (3 min for the entire sample preparation step). The MEPS/LC-UV method was shown to be linear at concentrations ranging from the limit of quantification (LOQ) to 1000 ng mL(-1). The LOQ values ranged from 10 to 25 ng mL(-1). The inter-day precision of the method presented coefficient of the variation ranging from 1.3% to 8.7%. On the basis of analytical validation, it is shown that the MEPS/LC-UV methodology is adequate for antidepressant analysis, from therapeutic to toxic levels. In order to evaluate the proposed method for clinical use, the MEPS/LC-UV method was applied to analysis of plasma samples from elderly depressed patients. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
A sensitive and reproducible stir bar-sorptive extraction and high performance liquid chromatography-UV detection (SBSE/HPLC-UV) method for therapeutic drug monitoring of rifampicin in plasma samples is described and compared with a liquid:liquid extraction (LLE/HPLC-UV) method. This miniaturized method can result in faster analysis, higher sample throughput, lower solvent consumption and less workload per sample while maintaining or even improving sensitivity. Important factors in the optimization of SBSE efficiency such as pH, temperature, extraction time and desorption conditions (solvents, mode magnetic stir, mode ultrasonic stir, time and number of steps) were optimized recoveries ranging from 75 to 80%. Separation was obtained using a reverse phase C(8) column with UV detection (254 nm). The mobile phase consisted of methanol:0.25 N sodium acetate buffer, pH 5.0 (58:42, v/v). The SBSE/HPLC-UV method was linear over a working range of 0.125-50.0 mu g mL(-1). The intra-assay and inter-assay precision and accuracy were studied at three concentrations (1.25, 6.25 and 25.0 mu g mL(-1)). The intra-assay coefficients of variation (CVs) for all compounds were less than 10% and all inter-CVs were less than 10%. Limits of quantification were 0.125 mu g mL(-1). Stability studies showed rifampicin was stable in plasma for 12 h after thawing; the samples were also stable for 24 h after preparation. Based on the figures of merit results, the SBSE/HPLC-UV proved to be adequate to the rifampicin analyses from therapeutic to toxic levels. This method was successfully applied to the analysis of real samples and was as effective as the LLE/HPLC-UV method. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
Modeling volatile organic compounds (voc`s) adsorption onto cup-stacked carbon nanotubes (cscnt) using the linear driving force model. Volatile organic compounds (VOC`s) are an important category of air pollutants and adsorption has been employed in the treatment (or simply concentration) of these compounds. The current study used an ordinary analytical methodology to evaluate the properties of a cup-stacked nanotube (CSCNT), a stacking morphology of truncated conical graphene, with large amounts of open edges on the outer surface and empty central channels. This work used a Carbotrap bearing a cup-stacked structure (composite); for comparison, Carbotrap was used as reference (without the nanotube). The retention and saturation capacities of both adsorbents to each concentration used (1, 5, 20 and 35 ppm of toluene and phenol) were evaluated. The composite performance was greater than Carbotrap; the saturation capacities for the composite was 67% higher than Carbotrap (average values). The Langmuir isotherm model was used to fit equilibrium data for both adsorbents, and a linear driving force model (LDF) was used to quantify intraparticle adsorption kinetics. LDF was suitable to describe the curves.
Resumo:
Analytical and bioanalytical methods of high-performance liquid chromatography with fluorescence detection (HPLC-FLD) were developed and validated for the determination of chloroaluminum phthalocyanine in different formulations of polymeric nanocapsules, plasma and livers of mice. Plasma and homogenized liver samples were extracted with ethyl acetate, and zinc phthalocyanine was used as internal standard. The results indicated that the methods were linear and selective for all matrices studied. Analysis of accuracy and precision showed adequate values, with variations lower than 10% in biological samples and lower than 2% in analytical samples. The recoveries were as high as 96% and 99% in the plasma and livers, respectively. The quantification limit of the analytical method was 1.12 ng/ml, and the limits of quantification of the bioanalytical method were 15 ng/ml and 75 ng/g for plasma and liver samples, respectively. The bioanalytical method developed was sensitive in the ranges of 15-100 ng/ml in plasma and 75-500 ng/g in liver samples and was applied to studies of biodistribution and pharmacokinetics of AlClPc. (C) 2011 Elsevier B.V. All rights reserved.
Resumo:
Malnourished rats since birth (mothers fed on 6% of protein) or controlled ones (16% of protein), half of each group received environmental stimulation (ES) from the age of 0-35th day, were studied. The performance in the elevated plus maze (EPM) was assessed on the last day. ES increased time spent and also the entries into open arms of EPM, but malnourished non-stimulated rats visited more segments near the central area than the distant ones. Data suggests an anxiolytic effect of ES which is less evident in malnourished rats. (C) 2009 Elsevier B.V. All rights reserved.
Resumo:
We discuss the expectation propagation (EP) algorithm for approximate Bayesian inference using a factorizing posterior approximation. For neural network models, we use a central limit theorem argument to make EP tractable when the number of parameters is large. For two types of models, we show that EP can achieve optimal generalization performance when data are drawn from a simple distribution.
Resumo:
Based on a self-similar array model, we systematically investigated the axial Young's modulus (Y-axis) of single-walled carbon nanotube (SWNT) arrays with diameters from nanometer to meter scales by an analytical approach. The results show that the Y-axis of SWNT arrays decreases dramatically with the increases of their hierarchy number (s) and is not sensitive to the specific size and constitution when s is the same, and the specific Young's modulus Y-axis(s) is independent of the packing configuration of SWNTs. Our calculations also show that the Y-axis of SWNT arrays with diameters of several micrometers is close to that of commercial high performance carbon fibers (CFs), but the Y-axis(s) of SWNT arrays is much better than that of high performance CFs. (C) 2005 American Institute of Physics.
Health promotion in general practice: A framework for identifying factors that influence performance
Resumo:
Background: The accuracy of multidetector computed tomographic (CT) angiography involving 64 detectors has not been well established. Methods: We conducted a multicenter study to examine the accuracy of 64-row, 0.5-mm multidetector CT angiography as compared with conventional coronary angiography in patients with suspected coronary artery disease. Nine centers enrolled patients who underwent calcium scoring and multidetector CT angiography before conventional coronary angiography. In 291 patients with calcium scores of 600 or less, segments 1.5 mm or more in diameter were analyzed by means of CT and conventional angiography at independent core laboratories. Stenoses of 50% or more were considered obstructive. The area under the receiver-operating-characteristic curve (AUC) was used to evaluate diagnostic accuracy relative to that of conventional angiography and subsequent revascularization status, whereas disease severity was assessed with the use of the modified Duke Coronary Artery Disease Index. Results: A total of 56% of patients had obstructive coronary artery disease. The patient-based diagnostic accuracy of quantitative CT angiography for detecting or ruling out stenoses of 50% or more according to conventional angiography revealed an AUC of 0.93 (95% confidence interval [CI], 0.90 to 0.96), with a sensitivity of 85% (95% CI, 79 to 90), a specificity of 90% (95% CI, 83 to 94), a positive predictive value of 91% (95% CI, 86 to 95), and a negative predictive value of 83% (95% CI, 75 to 89). CT angiography was similar to conventional angiography in its ability to identify patients who subsequently underwent revascularization: the AUC was 0.84 (95% CI, 0.79 to 0.88) for multidetector CT angiography and 0.82 (95% CI, 0.77 to 0.86) for conventional angiography. A per-vessel analysis of 866 vessels yielded an AUC of 0.91 (95% CI, 0.88 to 0.93). Disease severity ascertained by CT and conventional angiography was well correlated (r=0.81; 95% CI, 0.76 to 0.84). Two patients had important reactions to contrast medium after CT angiography. Conclusions: Multidetector CT angiography accurately identifies the presence and severity of obstructive coronary artery disease and subsequent revascularization in symptomatic patients. The negative and positive predictive values indicate that multidetector CT angiography cannot replace conventional coronary angiography at present. (ClinicalTrials.gov number, NCT00738218.).
Resumo:
OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.