945 resultados para pitch contour
Resumo:
'Surfer' is a computer package used to produce contour plots. Its marine applications therefore include production of bathymetric maps from measurements of depth, as well as contour plots of how oceanographic parameters vary in space and time in the water column.
Resumo:
Students taking the 20 credit version of the course (COMP6052) will work in groups of 6 to develop and design a new social networking tool/application/website. The teams will work on their design throughout the semester, and keep a design and development blog that will act as a digital portfolio of their work. At the end of the semester they will also be asked to submit an individual reflective summary that will outline their teams objectives and progress, their part in its progress, and a critical analysis of whether or not they were successful. At the end of the course teams will be asked to pitch their ideas to an interdisciplinary Dragon's Den style panel who will expect them to not only have created something that is technical viable, but will also want to see other economic, social, legal and ethical factors taken into consideration. In this presentation we explain the structure of the group project, what is expected in the blog, and explore some potential ideas to help students understand the scope of the work required. The outcome of the group project does not have to be a fully working piece of software, instead we are looking for a well developed idea that contains enough detail to be convincing to the panel.
Resumo:
El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.
Resumo:
Introducción: una de las causas de pobre ganancia visual luego de un tratamiento exitoso de desprendimiento de retina, sin complicaciones, es el daño de los fotoreceptores, reflejada en una disrupción de la capa de la zona elipsoide y membrana limitante externa (MLE). En otras patologías se ha demostrado que la hiperautofluorescencia foveal se correlaciona con la integridad de la zona elipsoide y MLE y una mejor recuperación visual. Objetivos: evaluar la asociación entre la hiperautofluorescencia foveal, la integridad de la capa de la zona elipsoide y recuperación visual luego de desprendimiento de retina regmatógeno (DRR) exitosamente tratado. Evaluar la concordancia inter-evaluador de estos exámenes. Metodología: estudio de corte transversal de autofluorescencia foveal y tomografía óptica coherente macular de dominio espectral en 65 pacientes con DRR evaluados por 3 evaluadores independientes. La concordancia inter-evaluador se estudio mediante Kappa de Cohen y la asociación entre las diferentes variables mediante la prueba chi cuadrado y pruebas Z para comparación de proporciones. Resultados: La concordancia de la autofluorescencia fue razonable y la de la tomografía óptica coherente macular buena a muy buena. Sujetos que presentaron hiperautofluorescencia foveal asociada a integridad de la capa de la zona elipsoide tuvieron 20% más de posibilidad de recuperar agudeza visual final mejor a 20/50 que los que no cumplieron éstas características. Conclusión: Existe una asociación clínicamente importante entre la hiperautofluorescencia foveal, la integridad de la capa de zona elipsoide y la mejor agudeza visual final, sin embargo ésta no fue estadísticamente significativa (p=0.39)
Revisión sistemática de la literatura: efecto de los rellenos inyectables en la región periorbitaria
Resumo:
Introducción: El conocimiento actual de la fisiopatología del envejecimiento periorbitario justifica la aplicación de materiales de relleno inyectables, dado que se enfocan en la restauración del volumen perdido en esta zona, convirtiéndose en una excelente alternativa a procedimientos quirúrgicos que remueven el tejido excedente. Sin embargo los efectos y la seguridad de esta naciente tendencia terapéutica aún no se sustentan en una sólida base científica. El objetivo de esta revisión es identificar el material de relleno inyectable más adecuado para el manejo de los defectos volumétricos estéticos de la región periorbitaria. Metodología: Se realizó una búsqueda exhaustiva de los artículos indexados publicados del 1º de enero de 2.000 al 30 de septiembre de 2.013, en diversas bases de datos electrónicas, se seleccionaron catorce publicaciones, se extrajo la información referente a datos demográficos, la intervención, el seguimiento y los desenlaces y se realizó un análisis de 14 estudios que cumplieron los criterios. Resultados: Todos los artículos incluidos poseían un bajo nivel de evidencia y del grado de recomendación. Todos los materiales de relleno se asociaron a altos niveles de satisfacción para el paciente, adecuada mejoría de la apariencia estética y similares efectos colaterales, el ácido hialurónico fue el material de relleno inyectable más utilizado en la región periorbitaria. Discusión: Los materiales de relleno inyectable mejoran los defectos volumétricos estéticos de la región periorbitaria pero es necesaria mayor evidencia para determinar el tipo relleno más apropiado para esta condición.
Resumo:
Introducción: La simpatectomía es el tratamiento de la hiperhidrosis palmar y consiste en denervación simpática de miembros superiores que produce un efecto en el flujo sanguíneo al impactar la respuesta vasoconstrictora. El cambio en el flujo sanguíneo se puede evaluar a través de la onda fotopletismográfica. Metodología: Se realizaron 2 sesiones (presimpatectomía y postsimpatectomía) de 10 minutos en cada miembro superior en 28 pacientes obteniendo 79 señales fotopletismográficas distribuidas así: 37 presimpatectomía y 42 señales postsimpatectomía. De cada señal se analizó 1.5 minutos donde se tienen 80 ondas de fotopletismografía y se miden 6 variables: 1. Componente AC (componente pulsátil), 2. Componente DC (componente no pulsátil), 3. Relación entre AC/DC (índice de perfusión), 4. Area bajo la curva (AUC), 5. Tiempo entre el inicio de la onda y pico sistólico (T_DA) y 6. Tiempo entre cada onda de pulso (T_DD). Resultados: Aumentó 120% el componente AC y disminuyó 78% en DC del miembro superior derecho (MSD) con 99% de confiabilidad (p<0.001) entre presimpatectomía (n=18) y postsimpatectomía (n=21). AC/DC aumentó 55% con 95% de confiabilidad entre presimpatectomía (n=19) y postsimpatectomía (n=21) en el miembro superior izquierdo (p<0.05). No se encontró diferencia para T_DA, T_DD ni AUC. Discusión y Conclusión: La simpatectomía en pacientes con hiperhidrosis palmar produce un cambio en el flujo sanguíneo de los miembros superiores evidenciado por los cambios en el componente no pulsátil (DC) y pulsátil (AC) que es secundario a la vasodilatación consecuencia del bloqueo simpático por la denervación quirúrgica de los ganglios simpáticos torácicos.
Resumo:
INTRODUCCIÓN. El ultrasonido es fundamental en la medicina de emergencias, no se conoce cual debería ser la curva de aprendizaje para obtener las competencias técnicas y operativas; ACEP recomienda por cada ventana ecográfica realizar 25 repeticiones. No existe una curva de aprendizaje para ventana de VCI en la población de residentes colombianos. OBJETIVO: Determinar la curva de aprendizaje necesaria para obtener una proporción mayor al 80% de éxitos en la toma de la ventana ecográfica de la VCI, usando la escala de calificación para el aseguramiento de la calidad sugerida por ACEP, en residentes de I a III año de medicina de emergencias. METODOLOGÍA: Estudio experimental no comparativo, que evaluó la proporción de éxito en función del las tomas repetidas de la VCI por ultrasonido, mediciones que se tomaron luego de participar en una capacitación teórica y demostrativa de la técnica propuesta; se calificaron los videos según la escala publicada por ACEP. El análisis estadístico se realizó con un modelo logístico multinivel para la proporción del éxito, agrupado por repetición y agrupado por sujeto. RESULTADOS: Se obtuvo información de 8 residentes, cada uno realizo 25 repeticiones a 3 modelos sanos con asignación aleatoria. Se realizó la curva de aprendizaje obteniendo en 11 repeticiones una proporción de 0.80 (rango 0.54 a 0.92) y en 21 repeticiones una proporción de 0.9 (rango 0.75 a 0.96), datos ajustados por numero de repetición y residente. CONCLUSIÓN: La curva de aprendizaje para la ventana ecográfica de la VCI es de 11 y 21 repeticiones para obtener el 80% y 90% de éxito en residentes de medicina de emergencias de I a III año de la universidad del rosario.
Resumo:
Esta investigación se centra en la Fédération Internationale de Football Association (FIFA) como organización política. Intenta responder dos interrogantes primordiales: 1) ¿cómo la FIFA ha constituido el poder que tiene actualmente y, así, hacerse del monopolio indiscutido del fútbol? Y 2) ¿cómo ha cambiado en el tiempo la política interna de FIFA y su vínculo con la política internacional? Para lograr esto, se realiza un estudio histórico, basado principalmente en documentos, que intenta caracterizar y analizar los cambios de la organización en el tiempo. Se enfatizan las últimas dos presidencias de FIFA, de João Havelange y Joseph Blatter, como casos de estudio.
Resumo:
The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density
Resumo:
The human visual ability to perceive depth looks like a puzzle. We perceive three-dimensional spatial information quickly and efficiently by using the binocular stereopsis of our eyes and, what is mote important the learning of the most common objects which we achieved through living. Nowadays, modelling the behaviour of our brain is a fiction, that is why the huge problem of 3D perception and further, interpretation is split into a sequence of easier problems. A lot of research is involved in robot vision in order to obtain 3D information of the surrounded scene. Most of this research is based on modelling the stereopsis of humans by using two cameras as if they were two eyes. This method is known as stereo vision and has been widely studied in the past and is being studied at present, and a lot of work will be surely done in the future. This fact allows us to affirm that this topic is one of the most interesting ones in computer vision. The stereo vision principle is based on obtaining the three dimensional position of an object point from the position of its projective points in both camera image planes. However, before inferring 3D information, the mathematical models of both cameras have to be known. This step is known as camera calibration and is broadly describes in the thesis. Perhaps the most important problem in stereo vision is the determination of the pair of homologue points in the two images, known as the correspondence problem, and it is also one of the most difficult problems to be solved which is currently investigated by a lot of researchers. The epipolar geometry allows us to reduce the correspondence problem. An approach to the epipolar geometry is describes in the thesis. Nevertheless, it does not solve it at all as a lot of considerations have to be taken into account. As an example we have to consider points without correspondence due to a surface occlusion or simply due to a projection out of the camera scope. The interest of the thesis is focused on structured light which has been considered as one of the most frequently used techniques in order to reduce the problems related lo stereo vision. Structured light is based on the relationship between a projected light pattern its projection and an image sensor. The deformations between the pattern projected into the scene and the one captured by the camera, permits to obtain three dimensional information of the illuminated scene. This technique has been widely used in such applications as: 3D object reconstruction, robot navigation, quality control, and so on. Although the projection of regular patterns solve the problem of points without match, it does not solve the problem of multiple matching, which leads us to use hard computing algorithms in order to search the correct matches. In recent years, another structured light technique has increased in importance. This technique is based on the codification of the light projected on the scene in order to be used as a tool to obtain an unique match. Each token of light is imaged by the camera, we have to read the label (decode the pattern) in order to solve the correspondence problem. The advantages and disadvantages of stereo vision against structured light and a survey on coded structured light are related and discussed. The work carried out in the frame of this thesis has permitted to present a new coded structured light pattern which solves the correspondence problem uniquely and robust. Unique, as each token of light is coded by a different word which removes the problem of multiple matching. Robust, since the pattern has been coded using the position of each token of light with respect to both co-ordinate axis. Algorithms and experimental results are included in the thesis. The reader can see examples 3D measurement of static objects, and the more complicated measurement of moving objects. The technique can be used in both cases as the pattern is coded by a single projection shot. Then it can be used in several applications of robot vision. Our interest is focused on the mathematical study of the camera and pattern projector models. We are also interested in how these models can be obtained by calibration, and how they can be used to obtained three dimensional information from two correspondence points. Furthermore, we have studied structured light and coded structured light, and we have presented a new coded structured light pattern. However, in this thesis we started from the assumption that the correspondence points could be well-segmented from the captured image. Computer vision constitutes a huge problem and a lot of work is being done at all levels of human vision modelling, starting from a)image acquisition; b) further image enhancement, filtering and processing, c) image segmentation which involves thresholding, thinning, contour detection, texture and colour analysis, and so on. The interest of this thesis starts in the next step, usually known as depth perception or 3D measurement.
Resumo:
Aquesta tesi està emmarcada dins la detecció precoç de masses, un dels símptomes més clars del càncer de mama, en imatges mamogràfiques. Primerament, s'ha fet un anàlisi extensiu dels diferents mètodes de la literatura, concloent que aquests mètodes són dependents de diferent paràmetres: el tamany i la forma de la massa i la densitat de la mama. Així, l'objectiu de la tesi és analitzar, dissenyar i implementar un mètode de detecció robust i independent d'aquests tres paràmetres. Per a tal fi, s'ha construït un patró deformable de la massa a partir de l'anàlisi de masses reals i, a continuació, aquest model és buscat en les imatges seguint un esquema probabilístic, obtenint una sèrie de regions sospitoses. Fent servir l'anàlisi 2DPCA, s'ha construït un algorisme capaç de discernir aquestes regions són realment una massa o no. La densitat de la mama és un paràmetre que s'introdueix de forma natural dins l'algorisme.
Resumo:
La miniaturització de la industria microelectrònica és un fet del tot inqüestionables i la tecnologia CMOS no n'és una excepció. En conseqüència la comunitat científica s'ha plantejat dos grans reptes: En primer lloc portar la tecnologia CMOS el més lluny possible ('Beyond CMOS') tot desenvolupant sistemes d'altes prestacions com microprocessadors, micro - nanosistemes o bé sistemes de píxels. I en segon lloc encetar una nova generació electrònica basada en tecnologies totalment diferents dins l'àmbit de les Nanotecnologies. Tots aquests avanços exigeixen una recerca i innovació constant en la resta d'àrees complementaries com són les d'encapsulat. L'encapsulat ha de satisfer bàsicament tres funcions: Interfície elèctrica del sistema amb l'exterior, Proporcionar un suport mecànic al sistema i Proporcionar un camí de dissipació de calor. Per tant, si tenim en compte que la majoria d'aquests dispositius d'altes prestacions demanden un alt nombre d'entrades i sortides, els mòduls multixip (MCMs) i la tecnologia flip chip es presenten com una solució molt interessant per aquests tipus de dispositiu. L'objectiu d'aquesta tesi és la de desenvolupar una tecnologia de mòduls multixip basada en interconnexions flip chip per a la integració de detectors de píxels híbrids, que inclou: 1) El desenvolupament d'una tecnologia de bumping basada en bumps de soldadura Sn/Ag eutèctics dipositats per electrodeposició amb un pitch de 50µm, i 2) El desenvolupament d'una tecnologia de vies d'or en silici que permet interconnectar i apilar xips verticalment (3D packaging) amb un pitch de 100µm. Finalment aquesta alta capacitat d'interconnexió dels encapsulats flip chip ha permès que sistemes de píxels tradicionalment monolítics puguin evolucionar cap a sistemes híbrids més compactes i complexes, i que en aquesta tesi s'ha vist reflectit transferint la tecnologia desenvolupada al camp de la física d'altes energies, en concret implantant el sistema de bump bonding d'un mamògraf digital. Addicionalment s'ha implantat també un dispositiu detector híbrid modular per a la reconstrucció d'imatges 3D en temps real, que ha donat lloc a una patent.
Resumo:
This paper reviews a study of tonal precepts such as pitch and timbre as a means of facilitating auditory discrimination tasks.
Resumo:
This paper investigates the use of data assimilation in coastal area morphodynamic modelling using Morecambe Bay as a study site. A simple model of the bay has been enhanced with a data assimilation scheme to better predict large-scale changes in bathymetry observed in the bay over a 3-year period. The 2DH decoupled morphodynamic model developed for the work is described, as is the optimal interpolation scheme used to assimilate waterline observations into the model run. Each waterline was acquired from a SAR satellite image and is essentially a contour of the bathymetry at some level within the inter-tidal zone of the bay. For model parameters calibrated against validation observations, model performance is good, even without data assimilation. However the use of data assimilation successfully compensates for a particular failing of the model, and helps to keep the model bathymetry on track. It also improves the ability of the model to predict future bathymetry. Although the benefits of data assimilation are demonstrated using waterline observations, any observations of morphology could potentially be used. These results suggest that data assimilation should be considered for use in future coastal area morphodynamic models.