986 resultados para First-derivative UV spectrophotometry


Relevância:

100.00% 100.00%

Publicador:

Resumo:

High performance liquid chromatographic (HPLC) and UV derivative spectrophotometric (UVDS) methods were developed and validated for the quantitative determination of sotalol hydrochloride in tablets. The HPLC method was performed on a C18 column with fluorescence detection. The excitation and emission wavelengths were 235 and 310nm, respectively. The mobile phase was composed of acetonitrile-water containing 0.1% trietylamine (7:93v/v) and pH adjusted to 4.6 with formic acid. The UVDS method was performed taking a signal at 239.1nm in the first derivative. The correlation coefficients (r) obtained were 0.9998 and 0.9997 for HPLC and UVDS methods, respectively. The proposed methods are simple and adaptable to routine analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

New rapid first-derivative spectrophotometric (UVDS) and a stability-indicating high performance liquid chromatographic (HPLC) methods were developed, validated and successfully applied in the analysis of loratadine (LT) in tablets and syrups. In the UVDS method, 0.1 M HCl was used as solvent. The measurements were made at 312.4 nm in the first order derivative spectra. The HPLC method was carried out on a RP-18 column with a mobile phase composed of methanol-water-tetrahydrofuran (50:30:20, v/v/v). UV detection was made at 247 nm. For HPLC methods the total analysis time was <3min, adequate for routine quality control of tablets and syrups containing loratadine.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A derivative UV spectrophotometric method for determination of estradiol valerate in tablets was validated. The parameters specificity, linearity, precision, accuracy, limit of detection and limit of quantitation were studied according to validation guidelines. The first-order derivative spectra were obtained at N = 5, Δλ = 4.0 nm, and determinations were made at 270 nm. The method showed specificity and linearity in the concentration range of 0.20 to 0.40 mg mL-1. The intra and interday precision data demonstrated the method has good reproducibility. Accuracy was also evaluated and results were satisfactory. The proposed method was successfully applied to a pharmaceutical formulation.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quzintification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity. precision, accuracy, recovery. detection (LOD) and quantification (LOQ) Inuits were established for method validation. First-derivative it 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging front 1.25 to 40.0 mu g/mL. (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD) was 0.08 mu g/mL and LOQ. 0.25 mu g/mL. Thus. the proposed method proved to be easy. low cost. and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A derivative spectrophotometric method was validated for quantification of acyclovir in poly (n-butylcyanoacrylate) (PBCA) nanoparticles. Specificity, linearity, precision, accuracy, recovery, detection (LOD) and quantification (LOQ) limits were established for method validation. First-derivative at 295.2 nm eliminated interferences from nanoparticle ingredients and presented linearity for acyclovir concentrations ranging from 1.25 to 40.0 µg/mL (r = 0.9999). Precision and accuracy data demonstrated good reproducibility. Recovery ranged from 99.3 to 101.2. LOD was 0.08 µg/mL and LOQ, 0.25 µg/mL. Thus, the proposed method proved to be easy, low cost, and accurate, and therefore, an useful alternative to quantify acyclovir in nanoparticles.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Ernst Mach observed that light or dark bands could be seen at abrupt changes of luminance gradient in the absence of peaks or troughs in luminance. Many models of feature detection share the idea that bars, lines, and Mach bands are found at peaks and troughs in the output of even-symmetric spatial filters. Our experiments assessed the appearance of Mach bands (position and width) and the probability of seeing them on a novel set of generalized Gaussian edges. Mach band probability was mainly determined by the shape of the luminance profile and increased with the sharpness of its corners, controlled by a single parameter (n). Doubling or halving the size of the images had no significant effect. Variations in contrast (20%-80%) and duration (50-300 ms) had relatively minor effects. These results rule out the idea that Mach bands depend simply on the amplitude of the second derivative, but a multiscale model, based on Gaussian-smoothed first- and second-derivative filtering, can account accurately for the probability and perceived spatial layout of the bands. A key idea is that Mach band visibility depends on the ratio of second- to first-derivative responses at peaks in the second-derivative scale-space map. This ratio is approximately scale-invariant and increases with the sharpness of the corners of the luminance ramp, as observed. The edges of Mach bands pose a surprisingly difficult challenge for models of edge detection, but a nonlinear third-derivative operation is shown to predict the locations of Mach band edges strikingly well. Mach bands thus shed new light on the role of multiscale filtering systems in feature coding. © 2012 ARVO.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Using a direct binding assay based on photoaffinity labeling, we have studied the interaction of an antigenic peptide with MHC class I molecules and the TCR on living cells. Two photoreactive derivatives of the H-2Kd (Kd) restricted Plasmodium berghei circumsporozoite (PbCS) peptide 253-260 (YIPSAEKI) were used. The first derivative contained an N-terminal photoreactive iodo, 4-azido salicyloyl (IASA) group and biotin on the TCR contact residue Lys259 [IASA-YIPSAEK(biotin)I]. As previously described, this derivative selectively bound to and labeled the Kd molecule. The second photoreactive compound, the isomeric biotin-YIPSAEK(IASA)I, also efficiently bound to the Kd molecule, but failed to label this protein. A CTL clone derived from a mouse immunized with this derivative recognized this conjugate but not the parental P. berghei circumsporozoite peptide or the [IASA-YIPSAEK-(biotin)I] derivative in an Kd-restricted manner. Incubation of the cloned CTL cells with biotin-YIPSAEK(IASA)I, but not its isomer, followed by UV irradiation resulted in photoaffinity labeling of the TCR-alpha chain that was dependent on the conjugate binding to the Kd molecule. The TCR labeling was partially inhibited by anti-LFA 1 and anti-ICAM1 mAb, but was increased by addition of beta 2m or soluble KdQ10. The exquisite labeling selectivity of the two photoprobes opens a new, direct approach to the molecular analysis of antigen presentation and recognition by living CTL.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Tässä työssä on tutkittu sellun kuivauskoneella koivusellua kuivattaessa esiintyvää ajettavuusongelmaa. Tähän ongelmaan on etsitty ratkaisua monimuuttujamenetelmien avulla. Työn kirjallisuusosassa on lyhyesti käyty läpi sellun kuivauskoneiden historia lieriöviirakoneista nykyaikaisiin kaksoisviirasovelluksiin. Lisäksi kirjallisuusosassa on käsitelty tässä työssä käytettyjen monimuuttujamenetelmien perusteet ja käyty esimerkin omaisesti läpi joitakin kemometrian sovelluksia puunjalostusteollisuudessa. Työn kokeellisessa osassa on haettu tiedonkeruujärjestelmästä massan ominaisuuksista ja kuivauskoneen ajoparametreistä koostuvaa dataa vuoden 1999 ajalta. Tästä datasta on tehty PCA-mallit vuoden 1999 jokaisen kuukauden datasta ja diskriminoiva PLS-malli ajettavuuden kannalta hyvästä ja huonosta jaksosta koostuvasta datasta. Kuivauskoneelta on koottu dataa myös ottamalla kiertovesi- ja selluarkkinäytteitä. Kiertovesinäytteiden analyysituloksista on tehty PCA-mallit ja lisäksi analyysitulokset on tarkasteltu yksimuuttujaisesti. Selluarkkinäytteistä on määritetty UV-spektrit ja niistä on tehty PCA-mallit, jotta spektreistä saataisiin mahdollisimman paljon informaatiota. Työssä on havaittu yhdeksi selitykseksi ajettavuusongelmalle kuivauskoneen kiertovesien likaantuminen. Kiertovesiä ja massarainan pintakemiaa tulisi kuitenkin tutkia laajemmassa mittakaavassa kuin tämän työn puitteissa on ollut mahdollista tutkia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A very simple spectrophotometric method is described for resolving binary mixture of the food colorants Sunset Yellow (INS 110) and Tartrazine Yellow (INS 102) by using the first derivative spectra with measurements at zero-crossing wavelengths. Before the spectrophotometric measurements, the dyes were sorbed onto polyurethane foam and recovered in N,N-dimethilformamide. Commercial food products (gelatine and juice powder) were analysed by using the proposed method and the HPLC technique. The results are in very good agreement and the differences between the methods is not statistically important. Therefore, the first-order derivative spectrophotometric method is accurate, precise, reliable and could be applied to the routine analysis of food samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay dexamethasone in tablets (assay and dissolution studies). The method was linear in the range between 1 and 30 µg mL-1 presenting a good correlation coefficient (r = 0.9998, n = 7). Precision and accuracy analysis showed low relative standard deviation (< 2.00%) and good percentual recoveries (95-105%). The procedure was linear, accurate, precise, and robust. The method is simple, and it has low cost. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay dexamethasone in tablets.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Spectrophotometric methods of zero order, first and second derived order had been developed for olanzapine determination in tablets using ethanol and isopropanol as solvent. The two solvents revealed to be adequate. For the three methods the calibration curve coefficient of correlation had been greater than 0.9998 with limit of detection varying from 0.068 to 0.190 mg L-1, in ethanol, and 0.026 to 0.205 mg L-1, in isopropanol. The inter-day precision was inferior to 1.1 and 1.9 mg L-1 for ethanol and isopropanol, respectively. The average recoveries varied from 98 to 101%, in ethanol and 99 to 103% in isopropanol.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work reports the validation of an analytical UV spectrophotometric method to assay acyclovir in hydrophilic matrices (assay and dissolution studies). The method was linear in the range between 2.5-20 µg mL-1, presenting a good correlation coefficient ( r = 0,9999). Precision and accuracy analysis showed low relative standart deviation (< 2.0 %) and a good recoveries percentual (98.9-100 %). The procedure was linear, accurate, and robust. The method is simple and cheap. It does not use polluting reagents and can be applied in dissolution studies, being an adequate alternative to assay acyclovir in hydrophilic matrices tablets.