Dissolution test for glibenclamide tablets


Autoria(s): Gianotto,Elisabeth Aparecida dos Santos; Arantes,Renata Pires; Lara-Filho,Maurilio José; Casimiro Filho,Alexandre Cezar Saraiva; Fregonezi-Nery,Marlene Maria
Data(s)

01/10/2007

Resumo

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Formato

text/html

Identificador

http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422007000500031

Idioma(s)

en

Publicador

Sociedade Brasileira de Química

Fonte

Química Nova v.30 n.5 2007

Palavras-Chave #glibenclamide #dissolution test #ultraviolet derivative spectrophotometry
Tipo

journal article