983 resultados para resistance exercises


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This series of research vignettes is aimed at sharing current and interesting research findings from our team of international entrepreneurship researchers. This vignette, written by Professor Per Davidsson, reports findings on how the onset of the Global Financial Crisis affected “nascent ventures”, i.e., on-going business start-up efforts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cold water immersion (CWI) and active recovery (ACT) are frequently used as post-exercise recovery strategies. However, the physiological effects of CWI and ACT after resistance exercise are not well characterized. We examined the effects of CWI and ACT on cardiac output (Q), muscle oxygenation (SmO2) and blood volume (tHb), muscle temperature (Tmuscle ) and isometric strength after resistance exercise. On separate days, 10 men performed resistance exercise, followed by 10 min CWI at 10°C or 10 min ACT (low-intensity cycling). Q (7.9±2.7 l) and Tmuscle (2.2±0.8ºC) increased, whereas SmO2 (-21.5±8.8%) and tHb (-10.1±7.7 μM) decreased after exercise (p<0.05). During CWI, Q ̇(-1.1±0.7 l) and Tmuscle (-6.6±5.3ºC) decreased, while tHb (121±77 μM) increased (p<0.05). In the hour after CWI, Q ̇and Tmuscle remained low, while tHb also decreased (p<0.05). By contrast, during ACT, Q ̇(3.9±2.3 l), Tmuscle (2.2±0.5ºC), SmO2 (17.1±5.7%) and tHb (91±66 μM) all increased (p<0.05). In the hour after ACT, Tmuscle and tHb remained high (p<0.05). Peak isometric strength during 10 s maximum voluntary contractions (MVCs) did not change significantly after CWI, whereas it decreased after ACT (-30 to -45 Nm; p<0.05). Muscle deoxygenation time during MVCs increased after ACT (p<0.05), but not after CWI. Muscle reoxygenation time after MVCs tended to increase after CWI (p=0.052). These findings suggest firstly that hemodynamics and muscle temperature after resistance exercise are dependent on ambient temperature and metabolic demands with skeletal muscle, and secondly, that recovery of strength after resistance exercise is independent of changes in hemodynamics and muscle temperature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The centrality of knowledge sharing to organizations’ sustainability has been established. This research explores and illustrates the influences for individual professionals and paraprofessionals – specifically civil engineers and design drafters – to share their deep, personally constructed knowledge, in a public sector provider of railways infrastructure. It investigates the extent to which: (i) knowledge sharing will be positively influenced by the professional identity, values and knowledge culture to achieve organizational and project goals, and; (ii) sharing of deep personal expertise will be influenced by the quality of relational capital among individuals and individual perspectives. It finds that knowledge sharing develops within frameworks established through the alignment among sector, profession and organization values. However, individual behavior is found to be most strongly influenced by the presence and quality of relational capital and individuals’ personal perspectives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose We determined the effect of reduced muscle glycogen availability on cellular pathways regulating mitochondrial biogenesis and substrate utilization after a bout of resistance exercise. Methods Eight young, recreationally trained men undertook a glycogen depletion protocol of one-leg cycling to fatigue (LOW), while the contralateral (control) leg rested (CONT). Following an overnight fast, subjects completed 8 sets of 5 unilateral leg press repetitions (REX) at 80 % 1 Repetition Maximum (1RM) on each leg. Subjects consumed 500 mL protein/CHO beverage (20 g whey + 40 g maltodextrin) upon completion of REX and 2 h later. Muscle biopsies were obtained at rest and 1 and 4 h after REX in both legs. Results Resting muscle glycogen was higher in the CONT than LOW leg (~384 ± 114 vs 184 ± 36 mmol kg−1 dry wt; P < 0.05), and 1 h and 4 h post-exercise (P < 0.05). Phosphorylation of p53Ser15 increased 1 h post-exercise in LOW (~115 %, P < 0.05) and was higher than CONT at this time point (~87 %, P < 0.05). p38MAPKThr180/Tyr182 phosphorylation increased 1 h post-exercise in both CONT and LOW (~800–900 %; P < 0.05) but remained above rest at 4 h only in CONT (~585 %, P < 0.05; different between legs P < 0.05). Peroxisome proliferator-activated receptor gamma coactivator-1α (PGC-1α) mRNA was elevated 4 h post-exercise in LOW (~200 %, P < 0.05; different between legs P < 0.05). There were no changes in Fibronectin type III domain-containing protein 5 (FNDC5) mRNA for CONT or LOW legs post-exercise. Conclusion Undertaking resistance exercise with low glycogen availability may enhance mitochondrial-related adaptations through p53 and PGC-1α-mediated signalling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Target-tilted room temperature sputtering of aluminium doped zinc oxide (AZO) provides transparent conducting electrodes with sheet resistances of <10 Ω □-1 and average transmittance in the visible region of up to 84%. The properties of the AZO electrode are found to be strongly dependent on the target-tilting angle and film thickness. The AZO electrodes showed comparable performance to commercial indium tin oxide (ITO) electrodes in organic photovoltaic (OPV) devices. OPV devices containing a bulk heterojunction active layer comprised of poly(3-n-hexylthiophene) (P3HT):phenyl-C61-butyric acid methyl ester (PCBM) and an AZO transparent conducting electrode had a power conversion efficiency (PCE) of up to 2.5% with those containing ITO giving a PCE of 2.6%. These results demonstrate that AZO films are a good alternative to ITO for transparent conducting electrodes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel protective covering with a layered and staggered structure was proposed to protect concrete against projectile impact. Experimental study was conducted to investigate the ballistic behaviour of the concrete targets against 12.7 mm armour-piercing incendiary projectile at velocities ranging from 537.7 to 596.5 m/s. The results showed that the concrete targets with protective covering exhibited superior integrity with no damage on the distal surface, whereas the concrete targets without protective covering were fractured with penetrating cracks throughout the thickness of the target. Moreover, the protected concrete targets displayed significantly reduced penetration depth compared with the concrete targets without protective covering. The protective covering with epoxy adhesive interlayers had a bigger protection factor than that with silicone sealant interlayers, but the former suffered more severe damage than the latter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

While virulence factors and the biofilm-forming capabilities of microbes are the key regulators of the wound healing process, the host immune response may also contribute in the events following wound closure or exacerbation of non-closure. We examined samples from diabetic and non-diabetic foot ulcers/wounds for microbial association and tested the microbes for their antibiotic susceptibility and ability to produce biofilms. A total of 1074 bacterial strains were obtained with staphylococci, Pseudomonas, Citrobacter and enterococci as major colonizers in diabetic samples. Though non-diabetic samples had a similar assemblage, the frequency of occurrence of different groups of bacteria was different. Gram-negative bacteria were found to be more prevalent in the diabetic wound environment while Gram-positive bacteria were predominant in non-diabetic ulcers. A higher frequency of monomicrobial infection was observed in samples from non-diabetic individuals when compared to samples from diabetic patients. The prevalence of different groups of bacteria varied when the samples were stratified according to age and sex of the individuals. Several multidrug-resistant strains were observed among the samples tested and most of these strains produced moderate to high levels of biofilms. The weakened immune response in diabetic individuals and synergism among pathogenic micro-organisms may be the critical factors that determine the delicate balance of the wound healing process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pervasive use of the World Wide Web by the general population has created a cultural shift in “our living world”. It has enabled more people to share more information about more events and issues in the world than was possible before its general use. As a consequence, it has transformed traditional news media’s approach to almost every aspect of journalism, with many organisations restructuring their philosophy and practice to include a variety of participatory spaces/forums where people are free to engage in deliberative dialogue about matters of public importance. Moreover, while news media were the traditional gatekeepers of information, today many organisations allow, to different degrees, the general public and other independent journalism entities to participate in the news production process, which may include agenda setting and content production. This paper draws from an international collective case study that showcases various approaches to networked online news journalism. It examines the ways in which different traditional news media models use digital tools and technologies for participatory communication of information about matters of public interest. The research finds differences between the ways in which public service, commercial and independent news media give voice to the public and ultimately their approach to journalism’s role as the Fourth Estate––one of the key institutions of democracy. The work is framed by the notion that journalism in democratic societies has a key role in ensuring citizens are informed and engaged with public affairs. An examination of four media models, the British Broadcasting Corporation (BBC), the Guardian, News Limited and OhmyNews, showcases the various approaches to networked online news journalism and how each provides different avenues for citizen empowerment. The cases are described and analysed in the context of their own social, political and economic setting. Semi-structured in-depth interviews with key senior journalists and editors provide specific information on comparisons between the distinctive practices of their own organisation. In particular these show how the ideal of democracy can be used as a tool of persuasion as much as a method of deliberation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Emerging evidence has shown that the extracellular vesicles (EVs) regulate various biological processes and can control cell proliferation and survival, as well as being involved in normal cell development and diseases such as cancers. In cancer treatment, development of acquired drug resistance phenotype is a serious issue. Recently it has been shown that the presence of multidrug resistance proteins such as Pgp-1 and enrichment of the lipid ceramide in EVs could have a role in mediating drug resistance. EVs could also mediate multidrug resistance through uptake of drugs in vesicles and thus limit the bioavailability of drugs to treat cancer cells. In this review, we discussed the emerging evidence of the role EVs play in mediating drug resistance in cancers and in particular the role of EVs mediating drug resistance in advanced prostate cancer. The role of EV-associated multidrug resistance proteins, miRNA, mRNA, and lipid as well as the potential interaction(s) among these factors was probed. Lastly, we provide an overview of the current available treatments for advanced prostate cancer, considering where EVs may mediate the development of resistance against these drugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The success of orthotopic liver transplantation as treatment for end-stage liver disease has prompted investigation of strategies to maintain or improve nutrition and growth in children awaiting transplantation, because malnutrition is an adverse prognostic factor. The purpose of this study was to evaluate the effect of recombinant human growth hormone therapy on body composition and indices of liver function in patients awaiting transplant. Methods: The study was designed as a placebo- controlled, double-blind, crossover trial. Patients received 0.2 U/kg growth hormone, subcutaneously, or placebo daily for 28 days during two treatment periods, separated by a 2-week washout period. Ten patients (mean age, 3.06 ± 1.15 years; range, 0.51-11.65 years, five men), with extrahepatic biliary atresia (n = 8) or two with Alagille's syndrome (n = 2), with end-stage liver disease, completed the trial while awaiting orthotopic liver transplantation. Height, weight, total body potassium, total body fat, resting energy expenditure, respiratory quotient, hematologic and multiple biochemical profile, number of albumin infusions, insulin-like growth factor-1 and 1, growth hormone binding protein (GHBP), and insulin-like growth factor binding protein-1 (IGFBP-1) and insulin-like growth factor binding protein (IGFBP-3) were measured at the beginning and end of each treatment period. Results: Growth hormone treatment was associated with a significant decline in serum bilirubin (-34.6 ± 16.5 μmol/l vs. 18.2 ± 11.59 μmol/l; p < 0.02) but there was no significant effect on any anthropometric or body composition measurements, or on any biochemical or hematologic parameters. Conclusions: These children with end-stage liver disease displayed growth hormone resistance, particularly in relation to the somatomedin axis. Exogenous growth hormone administration may be of limited value in these patients

Relevância:

20.00% 20.00%

Publicador:

Resumo:

D.C. electrical conductivity of polyaniline (33%,40%) blended with PMMA was measured from 5K to 300mK. The conductivity behaviour is consistent with fluctuation induced tunneling. Magneto-resistance (MR) was measured between 300K and 2K. From 20K to 2K, a large positive MR was observed. At 2K, for low magnetic fields (<1 Tesla), a deviation from the normal H-2 behaviour was observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines and quantifies the effect of adding polyelectrolytes to cellulose nanofibre suspensions on the gel point of cellulose nanofibre suspensions, which is the lowest solids concentration at which the suspension forms a continuous network. The lower the gel point, the faster the drainage time to produce a sheet and the higher the porosity of the final sheet formed. Two new techniques were designed to measure the dynamic compressibility and the drainability of nanocellulose–polyelectrolyte suspensions. We developed a master curve which showed that the independent variable controlling the behaviour of nanocellulose suspensions and its composite is the structure of the flocculated suspension which is best quantified as the gel point. This was independent of the type of polyelectrolyte used. At an addition level of 2 mg/g of nanofibre, a reduction in gel point over 50 % was achieved using either a high molecular weight (13 MDa) linear cationic polyacrylamide (CPAM, 40 % charge), a dendrimer polyethylenimine of high molecular weight of 750,000 Da (HPEI) or even a low molecular weight of 2000 Da (LPEI). There was no significant difference in the minimum gel point achieved, despite the difference in polyelectrolyte morphology and molecular weight. In this paper, we show that the gel point controls the flow through the fibre suspension, even when comparing fibre suspensions with solids content above the gel point. A lower gel point makes it easier for water to drain through the fibre network,reducing the pressure required to achieve a given dewatering rate and reducing the filtering time required to form a wet laid sheet. We further show that the lower gel point partially controls the structure of the wet laid sheet after it is dried. Halving the gel point increased the air permeability of the dry sheet by 37, 46 and 25 %, when using CPAM, HPEI and LPEI, respectively. The resistance to liquid flow was reduced by 74 and 90 %, when using CPAM and LPEI. Analysing the paper formed shows that sheet forming process and final sheet properties can be engineered and controlled by adding polyelectrolytes to the nanofibre suspension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate that the low-frequency resistance uctuations, or noise, in bilayer graphene is strongly connected to its band structure, and displays a minimum when the gap between the conduction and valence band is zero. Using double-gated bilayer graphene devices we have tuned the zero gap and charge neutrality points independently, which oers a versatile mechanism to investigate the low-energy band structure, charge localization and screening properties of bilayer graphene.