Energy based time equivalent approach to determine the fire resistance ratings of light gauge steel frame walls exposed to realistic design fire curves


Autoria(s): Ariyanayagam, Anthony Deloge; Mahendran, Mahen
Data(s)

2015

Resumo

Structural fire safety has become one of the key considerations in the design and maintenance of the built infrastructure. Conventionally the fire resistance rating of load bearing Light gauge Steel Frame (LSF) walls is determined based on the standard time-temperature curve given in ISO 834. Recent research has shown that the true fire resistance of building elements exposed to building fires can be less than their fire resistance ratings determined based on standard fire tests. It is questionable whether the standard time-temperature curve truly represents the fuel loads in modern buildings. Therefore an equivalent fire severity approach has been used in the past to obtain fire resistance rating. This is based on the performance of a structural member exposed to a realistic design fire curve in comparison to that of standard fire time-temperature curve. This paper presents the details of research undertaken to develop an energy based time equivalent approach to obtain the fire resistance ratings of LSF walls exposed to realistic design fire curves with respect to standard fire exposure. This approach relates to the amount of energy transferred to the member. The proposed method was used to predict the fire resistance ratings of single and double layer plasterboard lined and externally insulated LSF walls. The predicted fire ratings were compared with the results from finite element analyses and fire design rules for three different wall configurations exposed to both rapid and prolonged fires. The comparison shows that the proposed energy method can be used to obtain the fire resistance ratings of LSF walls in the case of prolonged fires.

Identificador

http://eprints.qut.edu.au/87014/

Publicador

Multi-Science Publishing Co. Ltd

Relação

Ariyanayagam, Anthony Deloge & Mahendran, Mahen (2015) Energy based time equivalent approach to determine the fire resistance ratings of light gauge steel frame walls exposed to realistic design fire curves. Journal of Structural Fire Engineering. (In Press)

Direitos

Multi-Science Publishing

Fonte

School of Civil Engineering & Built Environment; Faculty of Science and Technology; Institute for Future Environments

Palavras-Chave #090500 CIVIL ENGINEERING #090502 Construction Engineering #090506 Structural Engineering #Time equivalent approach #Fire resistance ratings #Light gauge steel frame walls #Realistic design fire curves #Energy based approach
Tipo

Journal Article