Loading compliance of static load bearing exercises performed by transfemoral amputees fitted with an osseointegrated implant
| Data(s) |
2015
|
|---|---|
| Resumo |
Background To date bone-anchored prostheses are used to alleviate the concerns caused by socket suspended prostheses and to improve the quality of life of transfemoral amputees (TFA). Currently, two implants are commercially available (i.e., OPRA (Integrum AB, Sweden), ILP (Orthodynamics GmbH, Germany)). [1-17]The success of the OPRA technique is codetermined by the rehabilitation program. TFA fitted with an osseointegrated implant perform progressive mechanical loading (i.e. static load bearing exercises (LBE)) to facilitate bone remodelling around the implant.[18, 19] Aim This study investigated the trustworthiness of monitoring the load prescribed (LP) during experimental static LBEs using the vertical force provided by a mechanical bathroom scale that is considered a surrogate of the actual load applied. Method Eleven unilateral TFAs fitted with an OPRA implant performed five trials in four loading conditions. The forces and moments on the three axes of the implant were measured directly with an instrumented pylon including a six-channel transducer. The “axial” and “vectorial” comparisons corresponding to the difference between the force applied on the long axis of the fixation and LP as well as the resultant of the three components of the load applied and LP, respectively were analysed Results For each loading condition, Wilcoxon One-Sample Signed Rank Tests were used to investigate if significant differences (p<0.05) could be demonstrated between the force applied on the long axis and LP, and between the resultant of the force and LP. The results demonstrated that the raw axial and vectorial differences were significantly different from zero in all conditions (p<0.05), except for the vectorial difference for the 40 kg loading condition (p=0.182). The raw axial difference was negative for all the participants in every loading condition, except for TFA03 in the 10 kg condition (11.17 N). Discussion & Conclusion This study showed a significant lack of axial compliance. The load applied on the long axis was significantly smaller than LP in every loading condition. This led to a systematic underloading of the long axis of the implant during the proposed experimental LBE. Monitoring the vertical force might be only partially reflective of the actual load applied, particularly on the long axis of the implant. |
| Formato |
application/pdf |
| Identificador | |
| Relação |
http://eprints.qut.edu.au/89033/1/Abs-ISPO%20Lyon-SV-LBE%20and%20load%20compliance-ePrint%2001.pdf DOI:10.1177/0309364615591101 Vertriest, Sofie, Coorevits, Pascal, Hagberg, Kerstin, Branemark, Rickard, Haggstrom, Eva, Vanderstraeten, Guy, & Frossard, Laurent (2015) Loading compliance of static load bearing exercises performed by transfemoral amputees fitted with an osseointegrated implant. In XV World Congress of the International Society for Prosthetics and Orthotics (ISPO), 22-25 June 2015, Lyon, France. |
| Direitos |
Copyright 2015 [please consult the authors] |
| Fonte |
Faculty of Health; Institute of Health and Biomedical Innovation; School of Exercise & Nutrition Sciences |
| Palavras-Chave | #090305 Rehabilitation Engineering #Osseointegration #Bone-anchored prosthesis #Implant #Amputation #Rehabiliation |
| Tipo |
Conference Paper |