988 resultados para Sustainability measurement
Resumo:
Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus.
Resumo:
We describe in detail the theory underpinning the measurement of density matrices of a pair of quantum two-level systems (qubits). Our particular emphasis is on qubits realized by the two polarization degrees of freedom of a pair of entangled photons generated in a down-conversion experiment; however, the discussion applies in general, regardless of the actual physical realization. Two techniques are discussed, namely, a tomographic reconstruction (in which the density matrix is linearly related to a set of measured quantities) and a maximum likelihood technique which requires numerical optimization (but has the advantage of producing density matrices that are always non-negative definite). In addition, a detailed error analysis is presented, allowing errors in quantities derived from the density matrix, such as the entropy or entanglement of formation, to be estimated. Examples based on down-conversion experiments are used to illustrate our results.
Resumo:
We present the conditional quantum dynamics of an electron tunneling between two quantum dots subject to a measurement using a low transparency point contact or tunnel junction. The double dot system forms a single qubit and the measurement corresponds to a continuous in time readout of the occupancy of the quantum dot. We illustrate the difference between conditional and unconditional dynamics of the qubit. The conditional dynamics is discussed in two regimes depending on the rate of tunneling through the point contact: quantum jumps, in which individual electron tunneling current events can be distinguished, and a diffusive dynamics in which individual events are ignored, and the time-averaged current is considered as a continuous diffusive variable. We include the effect of inefficient measurement and the influence of the relative phase between the two tunneling amplitudes of the double dot/point contact system.
Resumo:
The use of gate-to-drain capacitance (C-gd) measurement as a tool to characterize hot-carrier-induced charge centers in submicron n- and p-MOSFET's has been reviewed and demonstrated. By analyzing the change in C-gd measured at room and cryogenic temperature before and after high gate-to-drain transverse field (high field) and maximum substrate current (I-bmax) stress, it is concluded that the degradation was found to be mostly due to trapping of majority carriers and generation of interface states. These interface states were found to be acceptor states at top half of band gap for n-MOSFETs and donor states at bottom half of band gap for p-MOSFETs. In general, hot electrons are more likely to be trapped in gate oxide as compared to hot holes while the presence of hot holes generates more interface states. Also, we have demonstrated a new method for extracting the spatial distribution of oxide trapped charge, Q(ot), through gate-to-substrate capacitance (C-gb) measurement. This method is simple to implement and does not require additional information from simulation or detailed knowledge of the device's structure. (C) 2001 Elsevier Science Ltd. All rights reserved.
Resumo:
A new method to extract MOSFET's threshold voltage VT by measurement of the gate-to-substrate capacitance C-gb of the transistor is presented. Unlike existing extraction methods based on I-V data, the measurement of C-gb does not require de drain current to now between drain and source thus eliminating the effects of source and drain series resistance R-S/D, and at the same time, retains a symmetrical potential profile across the channel. Experimental and simulation results on devices with different sizes are presented to justify the proposed method.
Resumo:
Economic globalisation is seen by many as a driving force for global economic growth. Yet opinion is divided about the benefits of this process, as highlighted by the WTO meeting in Seattle in late 1999. Proponents of economic globalisation view it as a positive force for environmental improvement and as a major factor increasing the likelihood of sustainable development through its likely boost to global investment. These proponents mostly appeal to analysis based on the environmental Kuznets curve (EKC) to support their views about environmental improvement. But EKC-analysis has significant deficiencies. Furthermore, it is impossible to be confident that the process of economic globalisation will result in sustainable development, if 'weak conditions' only are satisfied. 'Strong conditions' probably need to be satisfied to achieve sustainable development, and given current global institutional arrangements, these are likely to be violated by the economic globalisation process. Global political action seems to be needed-to avert a deterioration in the global environment and to prevent unsustainability of development. This exposition demonstrates the limitations of EKC-analysis, identifies positive and negative effects of economic globalisation on pollution levels, and highlights connections between globalisation and the debate about whether strong or weak conditions are required for sustainable development. The article concludes with a short discussion of the position of WTO in relation to trade and the environment and the seemingly de facto endorsement of WTO of weak conditions for sustainable development. It suggests that WTO's relative neglect of environmental concerns is no longer politically tenable and needs to be reassessed in the light of recent developments in economic analysis. The skew of economic growth, e.g. in favour of developing countries, is shown to be extremely important from a global environmental perspective. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Use of chemical inputs such as pesticides has increased agricultural production and productivity. However, negative externalities from such use have increased too. These externalities include damage to agricultural land, fisheries, fauna and flora. Another major externality is the unintentional destruction of beneficial predators of pests thereby increasing the virulence of many species of agricultural pests. Furthermore, increased mortality and morbidity of humans due to exposure to pesticides are recorded especially in developing countries. The costs from these externalities are large and affect farmers' returns. However, despite these high costs, farmers continue to use pesticides and in most countries in increasing quantities. In this paper, we examine this paradox and show why farmers continue to use pesticides despite the increasing costs. We also emphasize 'lock-in' aspects of pesticide use. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Lateral ventricular volumes based on segmented brain MR images can be significantly underestimated if partial volume effects are not considered. This is because a group of voxels in the neighborhood of lateral ventricles is often mis-classified as gray matter voxels due to partial volume effects. This group of voxels is actually a mixture of ventricular cerebro-spinal fluid and the white matter and therefore, a portion of it should be included as part of the lateral ventricular structure. In this note, we describe an automated method for the measurement of lateral ventricular volumes on segmented brain MR images. Image segmentation was carried in combination of intensity correction and thresholding. The method is featured with a procedure for addressing mis-classified voxels in the surrounding of lateral ventricles. A detailed analysis showed that lateral ventricular volumes could be underestimated by 10 to 30% depending upon the size of the lateral ventricular structure, if mis-classified voxels were not included. Validation of the method was done through comparison with the averaged manually traced volumes. Finally, the merit of the method is demonstrated in the evaluation of the rate of lateral ventricular enlargement. (C) 2001 Elsevier Science Inc. All rights reserved.
Resumo:
A two-dimensional numerical simulation model of interface states in scanning capacitance microscopy (SCM) measurements of p-n junctions is presented-In the model, amphoteric interface states with two transition energies in the Si band gap are represented as fixed charges to account for their behavior in SCM measurements. The interface states are shown to cause a stretch-out-and a parallel shift of the capacitance-voltage characteristics in the depletion. and neutral regions of p-n junctions, respectively. This explains the discrepancy between - the SCM measurement and simulation near p-n junctions, and thus modeling interface states is crucial for SCM dopant profiling of p-n junctions. (C) 2002 American Institute of Physics.