The measurement of Pitot pressure in high enthalpy expansion tubes
Contribuinte(s) |
C. Tropea |
---|---|
Data(s) |
01/01/2001
|
Resumo |
Expansion tubes operating at total flow enthalpies of 100 MJ kg(-1) or more have characteristical test times of 30-50 mus. Under these conditions, the response time of the Pitot pressure measuring device is critical when performing flow calibration studies. The conventional technique of using a commercial pressure transducer protected by shielding has not always proven to be effective, due to the relatively large (and variable) response time caused by the shielding. A device called the stress wave bar gauge has been designed and calibrated and shown to be an effective way to measure the Pitot pressure with a response time of only 2-3 mus. |
Identificador | |
Idioma(s) |
eng |
Publicador |
IOP Publishing Ltd |
Palavras-Chave | #Engineering, Multidisciplinary #Instruments & Instrumentation #Pitot Pressure #Expansion Tube #Bar Gauge #Flow Calibration #Impulse Facility #C1 #290299 Aerospace Engineering not elsewhere classified #690302 Space transport |
Tipo |
Journal Article |