105 resultados para Precision ranching


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main analytical variables of a modified Folin-Ciocalteu method were studied by UV-Vis and gradient HPLC-PDA methods, using purified (PC) and technical grade (TGC) casein. Rutin and an aqueous extract of Psidium guajava L. leaves were used as models. The best results were ascribed to TGC. Certainly PC bonds the polyphenols of the P. guajava extract better than TGC, but TGC afforded better precision. A lack of specificity occurred when rutin was analyzed together with the P guajava extract. Additional analyses performed with the flavonoid fraction of P. guajava extract by HPLC-PDA had confirmed that casein was able to bind catechin, gallic acid and P. guajava flavonoids in a non-specific way.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cleaning solutions containing EDTA are widely employed to remove incrustation despite of the costs involved. The free content of EDTA in commercial solutions may be determined by mixing an aliquot to ammonium oxalate and using a standard calcium solution as titrant. The end-point is detected by the formation of insoluble calcium oxalate after all EDTA is complexed. A system for turbidimetric detection of the end-point was envisaged to substitute the visual detection, which impaired the analyses of dark samples. The proposed method was tested with real samples and good accuracy and precision was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to develop and validate a dissolution test for glibenclamide tablets. Optimal conditions to carry out the dissolution test are 500 mL of phosphate buffer at pH 8.0, paddles at 75 rpm stirring speed, time test set to 60 min and using equipment with six vessels. The derivative UV spectrophotometric method for determination of glibenclamide released was developed, validated and compared with the HPLC method. The UVDS method presents linearity (r² = 0.9999) in the concentration range of 5-14 µg/mL. Precision and recoveries were 0.42% and 100.25%, respectively. The method was applied to three products commercially available on the Brazilian market.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An HPLC method was validated to assay lamivudine and zidovudine combined in tablets. The chromatographic separation was carried out using methanol and acetate buffer pH 6.5 (50:50 v/v) and a RP-18 column, as mobile and stationary phase, respectively. The UV detection was at 270 nm. The method was linear in the range of 24 - 36 µg/mL (lamivudine) and 48 - 72 µg/mL (zidovudine). The recovery (accuracy) ranged from 101.35% to 103.04% and the precision (repeatability and intermediate precision) was less than 2%. The method can be also applied to the quantification of these drugs in the dissolution test of tablets containing both drugs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The analytical method developed to evaluate tamoxifen in dog plasma samples was precise, accurate, robust and linear in the range of 5-200 ng/mL. The limits of detection and quantification were 0.981 ng/mL and 2.97 ng/mL, respectively. Besides, the intra-day precision and accuracy variations were 8.78 and 10.16%, respectively. Tamoxifen concentrations were analyzed by combined reversed phase liquid chromatography and UV detection (lambda=280 nm). The study was conducted using an open randomized 2-period crossover balanced design with a 1-week washout period between the doses. This simple, rapid and selective method is suitable for pharmacokinetic, bioavailability and bioequivalence studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Harmane has been proposed for the treatment of epilepsy, AIDS and leshmaniosis. Its room-temperature phosphorescence was induced using either AgNO3 or TlNO3, enabling absolute limits of detection of 0.12 and 2.4 ng respectively, with linear dynamic ranges extending up to 456 ng (AgNO3) and 911 ng (TlNO3). Relative standard deviations around 3% were observed for substrates containing 46 ng of harmane. Such sensitivity and precision are needed because harmane intake must be strictly controlled to achieve proper therapeutic response. Interference studies were performed using thalidomide, reserpine and yohimbine. Recovery of 104±6% was achieved using solid surface room-temperature phosphorimetry. The result was comparable to the one obtained by micellar electrokinetic chromatography.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chemical reactions in the solid state are often not included in undergraduate chemistry curricula, due to requirements for special laboratory facilities such as ovens and precision weighing balances. This work aims to describe novel and relatively simple magnetite chemical syntheses in dry medium, which could also be used as an alternative for freshmen chemistry experiments. The proposed reaction was carried out in a muffle furnace by heating (i) a sol-gel preparation and (ii) natural hematite, under nitrogen atmosphere at 400 ºC. The synthesized magnetite was characterized with powder X-ray diffraction and Mössbauer spectroscopy. Results show that magnetite samples have chemical properties as well as crystalline structure quite similar to those of standard natural magnetite.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An analytical study based on extraction with methanol-water, immunoaffinity cleanup and separation, identification and quantification of aflatoxin B1 by thin-layer chromatography,in ground black and white pepper and oregano was carried out. Validation of the applied methodology was done through accuracy and precision studies. Recoveries of aflatoxin B1 and relative standard deviations, from spice samples spiked at levels from 4.86 to 97.70 µg/kg, were, respectively, higher than 72% and lower than 20%. Application to spice samples available in Minas Gerais state, purchased at popular markets, showed no contamination with aflatoxin B1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A liquid chromatography-tandem mass spectrometry method with atmospheric pressure chemical ionization (LC-APCI/MS/MS) was validated for the determination of etoricoxib in human plasma using antipyrin as internal standard, followed by on-line solid-phase extraction. The method was performed on a Luna C18 column and the mobile phase consisted of acetonitrile:water (95:5, v/v)/ammonium acetate (pH 4.0; 10 mM), run at a flow rate of 0.6 mL/min. The method was linear in the range of 1-5000 ng/mL (r²>0.99). The lower limit of quantitation was 1 ng/mL. The recoveries were within 93.72-96.18%. Moreover, method validation demonstrated acceptable results for the precision, accuracy and stability studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The water content in seafoods is very important since it affects their sensorial quality, microbiological stability, physical characteristics and shelf life. In this study, thermoanalytical techniques were employed to develop a simple and accurate method to determine water content (moisture) by thermogravimetry (TG) and water activity from moisture content values and freezing point depression using differential scanning calorimetry (DSC). The precision of the results suggests that TG is a suitable technique to determine moisture content in biological samples. The average water content values for fish samples of Lutjanus synagris and Ocyurus chrysurus species were 76.4 ± 5.7% and 63.3 ± 3.9%, respectively, while that of Ulva lactuca marine algae species was 76.0 ± 4.4%. The method presented here was also successfully applied to determine water activity in two species of fish and six species of marine algae collected in the Atlantic coastal waters of Bahia, in Brazil. Water activity determined in fish samples ranged from 0.946 - 0.960 and was consistent with values reported in the literature, i.e., 0.9 - 1.0. The water activity values determined in marine algae samples lay within the interval of 0.974 - 0.979.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports the development of a methodology for simultaneously determining As, Cd and Pb, employing GF AAS with polarized Zeeman-effect background correction. In order to make the procedure applicable, the influence of pyrolysis and atomization temperatures and the amount of chemical modifiers were studied. Factorial and central composite designs were used to optimize these variables. Precision and accuracy of the method were investigated using Natural Water Reference material, Nist SRM 1640. Results are in agreement with certified values at the 95% confidence limit when the Student t-test is used. This methodology was used for quality control of purified water for hemodialysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents Pd determinations in bovine tissue samples containing palladium prepared in the laboratory, and CCQM-P63 automotive catalyst materials of the Proficiency Test, using instrumental thermal and epithermal neutron activation analysis and energy dispersive X-ray fluorescence techniques. Solvent extraction and solid phase extraction procedures were also applied to separate Pd from interfering elements before the irradiation in the nuclear reactor. The results obtained by different techniques were compared against each other to examine sensitivity, precision and accuracy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes a simple and rapid spectrophotometric method for quantitative determination of sildenafil citrate based on its reaction with p-chloranil accelerated by hydrogen peroxide, producing a stable purple compound (λmax= 535 nm). In the absence of peroxide this reaction is very slow. The experimental conditions were optimized by using response surface methodologies. Beer's law is obeyed in a concentration range of 8.52 x 10-5 - 1.70 x 10-3 mol L-1 (r = 0.999). The detection limit was 1.96 x 10-5 mol L-1. The method was successfully applied for the determination of sildenafil citrate in medicines with good accuracy and precision.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two spectrophotometric methods are described for the simultaneous determination of ezetimibe (EZE) and simvastatin (SIM) in pharmaceutical preparations. The obtained data was evaluated by using two different chemometric techniques, Principal Component Regression (PCR) and Partial Least-Squares (PLS-1). In these techniques, the concentration data matrix was prepared by using the mixtures containing these drugs in methanol. The absorbance data matrix corresponding to the concentration data matrix was obtained by the measurements of absorbances in the range of 240 - 300 nm in the intervals with Δλ = 1 nm at 61 wavelengths in their zero order spectra, then, calibration or regression was obtained by using the absorbance data matrix and concentration data matrix for the prediction of the unknown concentrations of EZE and SIM in their mixture. The procedure did not require any separation step. The linear range was found to be 5 - 20 µg mL-1 for EZE and SIM in both methods. The accuracy and precision of the methods were assessed. These methods were successfully applied to a pharmaceutical preparation, tablet; and the results were compared with each other.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biological monitoring is very important to guarantee health to workers. This method was developed for simultaneous determination of xylene, toluene, styrene and ethylbenzene metabolites. It involves only dilution and centrifugation of urine samples and improved chromatographic conditions. Analyses show recovery > 95%; r² > 0.99; intermediate precision CV% < 6% and % bias < ±10. Exposed subjects presented at least three metabolites in urine. The method proved to be feasible, reliable and important in biological monitoring, especially in exposure to organic solvent mixtures.