30 resultados para droplet epitaxy
Resumo:
Sulfate aerosol plays an important but uncertain role in cloud formation and radiative forcing of the climate, and is also important for acid deposition and human health. The oxidation of SO2 to sulfate is a key reaction in determining the impact of sulfate in the environment through its effect on aerosol size distribution and composition. This thesis presents a laboratory investigation of sulfur isotope fractionation during SO2 oxidation by the most important gas-phase and heterogeneous pathways occurring in the atmosphere. The fractionation factors are then used to examine the role of sulfate formation in cloud processing of aerosol particles during the HCCT campaign in Thuringia, central Germany. The fractionation factor for the oxidation of SO2 by ·OH radicals was measured by reacting SO2 gas, with a known initial isotopic composition, with ·OH radicals generated from the photolysis of water at -25, 0, 19 and 40°C (Chapter 2). The product sulfate and the residual SO2 were collected as BaSO4 and the sulfur isotopic compositions measured with the Cameca NanoSIMS 50. The measured fractionation factor for 34S/32S during gas phase oxidation is αOH = (1.0089 ± 0.0007) − ((4 ± 5) × 10−5 )T (°C). Fractionation during oxidation by major aqueous pathways was measured by bubbling the SO2 gas through a solution of H2 O2
Resumo:
Microemulsions are thermodynamically stable, macroscopically homogeneous but microscopically heterogeneous, mixtures of water and oil stabilised by surfactant molecules. They have unique properties like ultralow interfacial tension, large interfacial area and the ability to solubilise other immiscible liquids. Depending on the temperature and concentration, non-ionic surfactants self assemble to micelles, flat lamellar, hexagonal and sponge like bicontinuous morphologies. Microemulsions have three different macroscopic phases (a) 1phase- microemulsion (isotropic), (b) 2phase-microemulsion coexisting with either expelled water or oil and (c) 3phase- microemulsion coexisting with expelled water and oil.rnrnOne of the most important fundamental questions in this field is the relation between the properties of the surfactant monolayer at water-oil interface and those of microemulsion. This monolayer forms an extended interface whose local curvature determines the structure of the microemulsion. The main part of my thesis deals with the quantitative measurements of the temperature induced phase transitions of water-oil-nonionic microemulsions and their interpretation using the temperature dependent spontaneous curvature [c0(T)] of the surfactant monolayer. In a 1phase- region, conservation of the components determines the droplet (domain) size (R) whereas in 2phase-region, it is determined by the temperature dependence of c0(T). The Helfrich bending free energy density includes the dependence of the droplet size on c0(T) as
Resumo:
Die Dissertationsschrift beschäftigt sich mit der Entwicklung und Anwendung einer alternativen Probenzuführungstechnik für flüssige Proben in der Massenspektrometrie. Obwohl bereits einige Anstrengungen zur Verbesserung unternommen wurden, weisen konventionelle pneumatische Zerstäuber- und Sprühkammersysteme, die in der Elementspurenanalytik mittels induktiv gekoppeltem Plasma (ICP) standardmäßig verwendet werden, eine geringe Gesamteffizienz auf. Pneumatisch erzeugtes Aerosol ist durch eine breite Tropfengrößenverteilung gekennzeichnet, was den Einsatz einer Sprühkammer bedingt, um die Aerosolcharakteristik an die Betriebsbedingungen des ICPs anzupassen.. Die Erzeugung von Tropfen mit einer sehr engen Tropfengrößenverteilung oder sogar monodispersen Tropfen könnte die Effizienz des Probeneintrags verbessern. Ein Ziel dieser Arbeit ist daher, Tropfen, die mittels des thermischen Tintenstrahldruckverfahrens erzeugt werden, zum Probeneintrag in der Elementmassenspektrometrie einzusetzen. Das thermische Tintenstrahldruckverfahren konnte in der analytischen Chemie im Bereich der Oberflächenanalytik mittels TXRF oder Laserablation bisher zur gezielten, reproduzierbaren Deposition von Tropfen auf Oberflächen eingesetzt werden. Um eine kontinuierliche Tropfenerzeugung zu ermöglichen, wurde ein elektronischer Mikrokontroller entwickelt, der eine Dosiereinheit unabhängig von der Hard- und Software des Druckers steuern kann. Dabei sind alle zur Tropfenerzeugung relevanten Parameter (Frequenz, Heizpulsenergie) unabhängig voneinander einstellbar. Die Dosiereinheit, der "drop-on-demand" Aerosolgenerator (DOD), wurde auf eine Aerosoltransportkammer montiert, welche die erzeugten Tropfen in die Ionisationsquelle befördert. Im Bereich der anorganischen Spurenanalytik konnten durch die Kombination des DOD mit einem automatischen Probengeber 53 Elemente untersucht und die erzielbare Empfindlichkeiten sowie exemplarisch für 15 Elemente die Nachweisgrenzen und die Untergrundäquivalentkonzentrationen ermittelt werden. Damit die Vorteile komfortabel genutzt werden können, wurde eine Kopplung des DOD-Systems mit der miniaturisierten Fließinjektionsanalyse (FIA) sowie miniaturisierten Trenntechniken wie der µHPLC entwickelt. Die Fließinjektionsmethode wurde mit einem zertifizierten Referenzmaterial validiert, wobei für Vanadium und Cadmium die zertifizierten Werte gut reproduziert werden konnten. Transiente Signale konnten bei der Kopplung des Dosiersystems in Verbindung mit der ICP-MS an eine µHPLC abgebildet werden. Die Modifikation der Dosiereinheit zum Ankoppeln an einen kontinuierlichen Probenfluss bedarf noch einer weiteren Reduzierung des verbleibenden Totvolumens. Dazu ist die Unabhängigkeit von den bisher verwendeten, kommerziell erhältlichen Druckerpatronen anzustreben, indem die Dosiereinheit selbst gefertigt wird. Die Vielseitigkeit des Dosiersystems wurde mit der Kopplung an eine kürzlich neu entwickelte Atmosphärendruck-Ionisationsmethode, die "flowing atmospheric-pressure afterglow" Desorptions/Ionisations Ionenquelle (FAPA), aufgezeigt. Ein direkter Eintrag von flüssigen Proben in diese Quelle war bislang nicht möglich, es konnte lediglich eine Desorption von eingetrockneten Rückständen oder direkt von der Flüssigkeitsoberfläche erfolgen. Die Präzision der Analyse ist dabei durch die variable Probenposition eingeschränkt. Mit dem Einsatz des DOD-Systems können flüssige Proben nun direkt in die FAPA eingetragen, was ebenfalls das Kalibrieren bei quantitativen Analysen organischer Verbindungen ermöglicht. Neben illegalen Drogen und deren Metaboliten konnten auch frei verkäufliche Medikamente und ein Sprengstoffanalogon in entsprechend präpariertem reinem Lösungsmittel nachgewiesen werden. Ebenso gelang dies in Urinproben, die mit Drogen und Drogenmetaboliten versetzt wurden. Dabei ist hervorzuheben, dass keinerlei Probenvorbereitung notwendig war und zur Ermittlung der NWG der einzelnen Spezies keine interne oder isotopenmarkierte Standards verwendet wurden. Dennoch sind die ermittelten NWG deutlich niedriger, als die mit der bisherigen Prozedur zur Analyse flüssiger Proben erreichbaren. Um im Vergleich zu der bisher verwendeten "pin-to-plate" Geometrie der FAPA die Lösungsmittelverdampfung zu beschleunigen, wurde eine alternative Elektrodenanordnung entwickelt, bei der die Probe länger in Kontakt mit der "afterglow"-Zone steht. Diese Glimmentladungsquelle ist ringförmig und erlaubt einen Probeneintrag mittels eines zentralen Gasflusses. Wegen der ringförmigen Entladung wird der Name "halo-FAPA" (h-FAPA) für diese Entladungsgeometrie verwendet. Eine grundlegende physikalische und spektroskopische Charakterisierung zeigte, dass es sich tatsächlich um eine FAPA Desorptions/Ionisationsquelle handelt.
Resumo:
Die pneumatische Zerstäubung ist die häufigste Methode der Probenzuführung von Flüssigkeiten in der Plasmaspektrometrie. Trotz der bekannten Limitierungen dieser Systeme, wie die hohen Probenverluste, finden diese Zerstäuber aufgrund ihrer guten Robustheit eine breite Anwendung. Die flussratenabhängige Aerosolcharakteristik und pumpenbasierte Signalschwankungen limitieren bisher Weiterentwicklungen. Diese Probleme werden umso gravierender, je weiter die notwendige Miniaturisierung dieser Systeme fortschreitet. Der neuartige Ansatz dieser Arbeit basiert auf dem Einsatz modifizierter Inkjet-Druckerpatronen für die Dosierung von pL-Tropfen. Ein selbst entwickelter Mikrokontroller ermöglicht den Betrieb von matrixkodierten Patronen des Typs HP45 mit vollem Zugriff auf alle essentiellen Betriebsparameter. Durch die neuartige Aerosoltransportkammer gelang die effiziente Kopplung des Tropfenerzeugungssystems an ein ICP-MS. Das so aufgebaute drop-on-demand-System (DOD) zeigt im Vergleich zu herkömmlichen und miniaturisierten Zerstäubern eine deutlich gesteigerte Empfindlichkeit (8 - 18x, elementabhängig) bei leicht erhöhtem, aber im Grunde vergleichbarem Signalrauschen. Darüber hinaus ist die Flexibilität durch die große Zahl an Freiheitsgraden des Systems überragend. So ist die Flussrate über einen großen Bereich variabel (5 nL - 12,5 µL min-1), ohne dabei die primäre Aerosolcharakteristik zu beeinflussen, welche vom Nutzer durch Wahl der elektrischen Parameter bestimmt wird. Das entwickelte Probenzuführungssystem ist verglichen mit dem pneumatischen Referenzsystem weniger anfällig gegenüber Matrixeffekten beim Einsatz von realen Proben mit hohen Anteilen gelöster Substanzen. So gelingt die richtige Quantifizierung von fünf Metallen im Spurenkonzentrationsbereich (Li, Sr, Mo, Sb und Cs) in nur 12 µL Urin-Referenzmaterial mittels externer Kalibrierung ohne Matrixanpassung. Wohingegen beim pneumatischen Referenzsystem die aufwändigere Standardadditionsmethode sowie über 250 µL Probenvolumen für eine akkurate Bestimmung der Analyten nötig sind. Darüber hinaus wird basierend auf der Dosierfrequenz eines dualen DOD-Systems eine neuartige Kalibrierstrategie vorgestellt. Bei diesem Ansatz werden nur eine Standard- und eine Blindlösung anstelle einer Reihe unterschiedlich konzentrierter Standards benötigt, um eine lineare Kalibrierfunktion zu erzeugen. Zusätzlich wurde mittels selbst entwickelter, zeitlich aufgelöster ICP-MS umfangreiche Rauschspektren aufgenommen. Aus diesen gelang die Ermittlung der Ursache des erhöhten Signalrauschens des DOD, welches maßgeblich durch das zeitlich nicht äquidistante Eintreffen der Tropfen am Detektor verursacht wird. Diese Messtechnik erlaubt auch die Detektion einzeln zugeführter Tropfen, wodurch ein Vergleich der Volumenverteilung der mittels ICP-MS detektierten, gegenüber den generierten und auf optischem Wege charakterisierten Tropfen möglich wurde. Dieses Werkzeug ist für diagnostische Untersuchungen äußerst hilfreich. So konnte aus diesen Studien neben der Aufklärung von Aerosoltransportprozessen die Transporteffizienz des DOD ermittelt werden, welche bis zu 94 Vol.-% beträgt.
Resumo:
Die Analyse optischer Spektren liefert einen kernmodellunabhängigen Zugang zur Bestimmung der Kernspins, Ladungsradien und elektromagnetischen Momente von Atomkernen im Grundzustand und von langlebigen Isomeren. Eine der vielseitigsten Methoden zur optischen Spektroskopie an kurzlebigen Isotopen ist die kollineare Laserspektroskopie. Im Rahmen dieser Arbeit wurde zum einen die TRIGA-LASER Strahlstrecke am Institut für Kernchemie der Universität Mainz durch die Implementierung einer neuen offline Oberflächenionenquelle für hohe Verdampfungstemperaturen und eines Strahlanalysesystems weiterentwickelt. Zum anderen wurde kollineare Laserspektroskopie an kurzlebigen Praseodym- und Cadmiumisotopen an ISOLDE/CERN durchgeführt. Die neue Ionenquelle ermöglichte dabei den Test der kollinearen Laserspektroskopie an Praseodymionen am TRIGA-LASER Experiment. Die Spektroskopie der Prasdeodymionen motivierte sich aus der Beobachtung einer zeitlichen Modulation der EC-Zerfallsrate von wasserstoffähnlichem 140Pr58+. Für die Erklärung dieser sogenannten GSI Oszillationen wird unter anderem das magnetische Moment des Kerns benötigt, welches bislang noch nicht experimentell bestimmt wurde. Zudem wurde für wasserstoffähnliches 140Pr58+ überraschenderweise eine kleinere EC-Zerfallskonstante gemessen als für heliumähnliches 140Pr57+. Die Erklärung dieses Phänomens setzt ein positives magnetisches Moment voraus. Bei der Spektroskopie am COLLAPS Experiment wurden erstmals die magnetischen Momente von 135Pr, 136Pr und 137Pr vermessen. Aufgrund zu geringer Produktionsraten war die Spektroskopie des gewünschten Isotops 140Pr jedoch nicht erfolgreich. Die Untersuchung der Cadmiumisotope ist kernphysikalisch motiviert. In der Zinnregion erstrecken sich die Isotope über die beiden magischen Zahlen N=50 und N=82 bei gleichzeitiger Nähe des Z=50 Schalenabschlusses. Hier können verschiedene Kernmodelle getestet werden, die sich beispielsweise hinsichtlich der Stärke des N=82 Schalenabschlusses widersprechen. Diese Arbeit berichtet über erste Ergebnisse der Spektroskopie an Cadmiumatomen, die sich über die Isotope 106−124,126Cd sowie die zugehörigen langlebigen I=11/2− Isomere erstreckt. Die zuvor experimentell bekannten oder aus dem erweiterten Schalenmodell abgeleiteten Kernspins konnten für alle Isotope bis auf 119Cd bestätigt werden. Der Kernspin von 119Cd wurde eindeutig zu I=1/2 bestimmt. Die elektrischen Quadrupolmomente der Isomere zeigen ein bemerkenswert lineares Verhalten in Abhängigkeit von der Neutronenzahl und dies über die eigentliche Kapazität der 1h11/2 Unterschale hinaus. Die Änderungen der mittleren quadratischen Ladungsradien zeigen den auch an Indium- und Zinnisotopen beobachteten stetigen Verlauf. Der lineare Anteil passt sehr gut zu den Berechnung des Tröpfchenmodells in der Parametrisierung nach Berchidevsky und Tondeur. Die Differenzen der mittleren quadratischen Ladungsradien zwischen Grund- und isomeren Zustand der ungeraden Cadmiumisotope zeigen einen interessanten parabolischen Verlauf mit einem Minimum zwischen A=117 und A=119.
Resumo:
In this thesis, different complex colloids were prepared by the process of solvent evaporation from emulsion droplets (SEED). The term “complex” is used to include both an addressable functionality as well as the heterogeneous nature of the colloids.Firstly, as the SEED process was used throughout the thesis, its mechanism especially in regard to coalescence was investigated,. A wide variety of different techniques was employed to study the coalescence of nanodroplets during the evaporation of the solvent. Techniques such as DLS or FCS turned out not to be suitable methods to determine droplet coalescence because of their dependence on dilution. Thus, other methods were developed. TEM measurements were conducted on mixed polymeric emulsions with the results pointing to an absence of coalescence. However, these results were not quantifiable. FRET measurements on mixed polymeric emulsions also indicated an absence of coalescence. Again the results were not quantifiable. The amount of coalescence taking place was then quantified by the application of DC-FCCS. This method also allowed for measuring coalescence in other processes such as the miniemulsion polymerization or the polycondensation reaction on the interface of the droplets. By simulations it was shown that coalescence is not responsible for the usually observed broad size distribution of the produced particles. Therefore, the process itself, especially the emulsification step, needs to be improved to generate monodisperse colloids.rnThe Janus morphology is probably the best known among the different complex morphologies of nanoparticles. With the help of functional polymers, it was possible to marry click-chemistry to Janus particles. A large library of functional polymers was prepared by copolymerization and subsequent post-functionalization or by ATRP. The polymers were then used to generate Janus particles by the SEED process. Both dually functionalized Janus particles and particles with one functionalized face could be obtained. The latter were used for the quantification of functional groups on the surface of the Janus particles. For this, clickable fluorescent dyes were synthesized. The degree of functionality of the polymers was found to be closely mirrored in the degree of functionality of the surface. Thus, the marriage of click-chemistry to Janus particles was successful.Another complex morphology besides Janus particles are nanocapsules. Stimulus-responsive nanocapsules that show triggered release are a highly demanding and interesting system, as nanocapsules have promising applications in drug delivery and in self-healing materials. To achieve heterogeneity in the polymer shell, the stimulus-responsive block copolymer PVFc-b-PMMA was employed for the preparation of the capsules. The phase separation of the two blocks in the shell of the capsules led to a patchy morphology. These patches could then be oxidized resulting in morphology changes. In addition, swelling occurred because of the hydrophobic to hydrophilic transition of the patches induced by the oxidation. Due to the swelling, an encapsulated payload could diffuse out of the capsules, hence release was achieved.The concept of using block copolymers responsive to one stimulus for the preparation of stimulus-responsive capsules was extended to block copolymers responsive to more than one stimulus. Here, a block copolymer responsive to oxidation and a pH change as well as a block copolymer responsive to a pH change and temperature were studied in detail. The release from the nanocapsules could be regulated by tuning the different stimuli. In addition, by encapsulating stimuli-responsive payloads it was possible to selectively release a payload upon one stimulus but not upon the other one.In conclusion, the approaches taken in the course of this thesis demonstrate the broad applicability and usefulness of the SEED process to generate complex colloids. In addition, the experimental techniques established such as DC-FCCS will provide further insight into other research areas as well.
Resumo:
Polare Stratosphärenwolken (PSC), die unterhalb einer Temperatur von etwa -78 °C in polaren Regionen auftreten, üben einen starken Einfluss auf die stratosphärische Ozonschicht aus. Dieser Einfluss erfolgt größtenteils über heterogene chemische Reaktionen, die auf den Oberflächen von Wolkenpartikeln stattfinden. Chemische Reaktionen die dabei ablaufen sind eine Voraussetzung für den späteren Ozonabbau. Des Weiteren verändert die Sedimentation der Wolkenpartikel die chemische Zusammensetzung bzw. die vertikale Verteilung der Spurengase in der Stratosphäre. Für die Ozonchemie spielt dabei die Beseitigung von reaktivem Stickstoff durch Sedimentation Salpetersäure-haltiger Wolkenpartikeln (Denitrifizierung) eine wichtige Rolle. Durch gleichen Sedimentationsprozess von PSC Elementen wird der Stratosphäre des weiteren Wasserdampf entzogen (Dehydrierung). Beide Prozesse begünstigen einen länger andauernden stratosphärischen Ozonabbau im polaren Frühling.rnGerade im Hinblick auf die Denitrifikation durch Sedimentation größerer PSC-Partikel werden in dieser Arbeit neue Resultate von in-situ Messungen vorgestellt, die im Rahmen der RECONCILE-Kampagne im Winter des Jahres 2010 an Bord des Höhenforschungs-Flugzeugs M-55 Geophysica durchgeführt wurden. Dabei wurden in fünf Flügen Partikelgrößenverteilungen in einem Größenbereich zwischen 0,5 und 35 µm mittels auf der Lichtstreuung basierender Wolkenpartikel-Spektrometer gemessen. Da polare Stratosphärenwolken in Höhen zwischen 17 und 30 km auftreten, sind in-situ Messungen vergleichsweise selten, so dass noch einige offene Fragen bestehen bleiben. Gerade Partikel mit optischen Durchmessern von bis zu 35µm, die während der neuen Messungen detektiert wurden, müssen mit theoretischen Einschränkungen in Einklang gebracht werden. Die Größe der Partikel wird dabei durch die Verfügbarkeit der beteiligten Spurenstoffe (Wasserdampf und Salpetersäure), die Sedimentationsgeschwindigkeit, Zeit zum Anwachsen und von der Umgebungstemperatur begrenzt. Diese Faktoren werden in der vorliegenden Arbeit diskutiert. Aus dem gemessenen Partikelvolumen wird beispielsweise unter der Annahme der NAT-Zusammensetzung (Nitric Acid Trihydrate) die äquivalente Konzentration des HNO 3 der Gasphase berechnet. Im Ergebnis wird die verfügbare Konzentration von Salpetersäure der Stratosphäre überschritten. Anschließend werden Hypothesen diskutiert, wodurch das gemessene Partikelvolumen überschätzt worden sein könnte, was z.B. im Fall einer starken Asphärizität der Partikel möglich wäre. Weiterhin wurde eine Partikelmode unterhalb von 2-3µm im Durchmesser aufgrund des Temperaturverhaltens als STS (Supercooled Ternary Solution droplets) identifiziert.rnUm die Konzentration der Wolkenpartikel anhand der Messung möglichst genau berechnen zu können, muss das Messvolumen bzw. die effektive Messfläche der Instrumente bekannt sein. Zum Vermessen dieser Messfläche wurde ein Tröpfchengenerator aufgebaut und zum Kalibrieren von drei Instrumenten benutzt. Die Kalibration mittels des Tröpfchengenerators konzentrierte sich auf die Cloud Combination Probe (CCP). Neben der Messfläche und der Größenbestimmung der Partikel werden in der Arbeit unter Zuhilfenahme von Messungen in troposphärischen Wolken und an einer Wolkensimulationskammer auch weitere Fehlerquellen der Messung untersucht. Dazu wurde unter anderem die statistische Betrachtung von Intervallzeiten einzelner Messereignisse, die in neueren Sonden aufgezeichnet werden, herangezogen. Letzteres ermöglicht es, Messartefakte wie Rauschen, Koinzidenzfehler oder „Shattering“ zu identifizieren.rn
Resumo:
Understanding and controlling the mechanism of the diffusion of small molecules, macromolecules and nanoparticles in heterogeneous environments is of paramount fundamental and technological importance. The aim of the thesis is to show, how by studying the tracer diffusion in complex systems, one can obtain information about the tracer itself, and the system where the tracer is diffusing. rnIn the first part of my thesis I will introduce the Fluorescence Correlation Spectroscopy (FCS) which is a powerful tool to investigate the diffusion of fluorescent species in various environments. By using the main advantage of FCS namely the very small probing volume (<1µm3) I was able to track the kinetics of phase separation in polymer blends at late stages by looking on the molecular tracer diffusion in individual domains of the heterogeneous structure of the blend. The phase separation process at intermediate stages was monitored with laser scanning confocal microscopy (LSCM) in real time providing images of droplet coalescence and growth. rnIn a further project described in my thesis I will show that even when the length scale of the heterogeneities becomes smaller than the FCS probing volume one can still obtain important microscopic information by studying small tracer diffusion. To do so, I will introduce a system of star shaped polymer solutions and will demonstrate that the mobility of small molecular tracers on microscopic level is nearly not affected by the transition of the polymer system to a “glassy” macroscopic state. rnIn the last part of the thesis I will introduce and describe a new stimuli responsive system which I have developed, that combines two levels of nanoporosity. The system is based on poly-N-isopropylacrylamide (PNIPAM) and silica inverse opals (iOpals), and allows controlling the diffusion of tracer molecules. rn
Resumo:
Granular matter, also known as bulk solids, consists of discrete particles with sizes between micrometers and meters. They are present in many industrial applications as well as daily life, like in food processing, pharmaceutics or in the oil and mining industry. When handling granular matter the bulk solids are stored, mixed, conveyed or filtered. These techniques are based on observations in macroscopic experiments, i.e. rheological examinations of the bulk properties. Despite the amply investigations of bulk mechanics, the relation between single particle motion and macroscopic behavior is still not well understood. For exploring the microscopic properties on a single particle level, 3D imaging techniques are required.rnThe objective of this work was the investigation of single particle motions in a bulk system in 3D under an external mechanical load, i.e. compression and shear. During the mechanical load the structural and dynamical properties of these systems were examined with confocal microscopy. Therefor new granular model systems in the wet and dry state were designed and prepared. As the particles are solid bodies, their motion is described by six degrees of freedom. To explore their entire motion with all degrees of freedom, a technique to visualize the rotation of spherical micrometer sized particles in 3D was developed. rnOne of the foci during this dissertation was a model system for dry cohesive granular matter. In such systems the particle motion during a compression of the granular matter was investigated. In general the rotation of single particles was the more sensitive parameter compared to the translation. In regions with large structural changes the rotation had an earlier onset than the translation. In granular systems under shear, shear dilatation and shear zone formation were observed. Globally the granular sediments showed a shear behavior, which was known already from classical shear experiments, for example with Jenike cells. Locally the shear zone formation was enhanced, when near the applied load a pre-diluted region existed. In regions with constant volume fraction a mixing between the different particle layers occurred. In particular an exchange of particles between the current flowing region and the non-flowing region was observed. rnThe second focus was on model systems for wet granular matter, where an additional binding liquid is added to the particle suspension. To examine the 3D structure of the binding liquid on the micrometer scale independently from the particles, a second illumination and detection beam path was implemented. In shear and compression experiments of wet clusters and bulk systems completely different dynamics compared to dry cohesive models systems occured. In a Pickering emulsion-like system large structural changes predominantly occurred in the local environment of binding liquid droplets. These large local structural changes were due to an energy interplay between the energy stored in the binding droplet during its deformation and the binding energy of particles at the droplet interface. rnConfocal microscopy in combination with nanoindentation gave new insights into the single particle motions and dynamics of granular systems under a mechanical load. These novel experimental results can help to improve the understanding of the relationship between bulk properties of granular matter, such as volume fraction or yield stress and the dynamics on a single particle level.rnrn
Resumo:
In condensed matter systems, the interfacial tension plays a central role for a multitude of phenomena. It is the driving force for nucleation processes, determines the shape and structure of crystalline structures and is important for industrial applications. Despite its importance, the interfacial tension is hard to determine in experiments and also in computer simulations. While for liquid-vapor interfacial tensions there exist sophisticated simulation methods to compute the interfacial tension, current methods for solid-liquid interfaces produce unsatisfactory results.rnrnAs a first approach to this topic, the influence of the interfacial tension on nuclei is studied within the three-dimensional Ising model. This model is well suited because despite its simplicity, one can learn much about nucleation of crystalline nuclei. Below the so-called roughening temperature, nuclei in the Ising model are not spherical anymore but become cubic because of the anisotropy of the interfacial tension. This is similar to crystalline nuclei, which are in general not spherical but more like a convex polyhedron with flat facets on the surface. In this context, the problem of distinguishing between the two bulk phases in the vicinity of the diffuse droplet surface is addressed. A new definition is found which correctly determines the volume of a droplet in a given configuration if compared to the volume predicted by simple macroscopic assumptions.rnrnTo compute the interfacial tension of solid-liquid interfaces, a new Monte Carlo method called ensemble switch method'' is presented which allows to compute the interfacial tension of liquid-vapor interfaces as well as solid-liquid interfaces with great accuracy. In the past, the dependence of the interfacial tension on the finite size and shape of the simulation box has often been neglected although there is a nontrivial dependence on the box dimensions. As a consequence, one needs to systematically increase the box size and extrapolate to infinite volume in order to accurately predict the interfacial tension. Therefore, a thorough finite-size scaling analysis is established in this thesis. Logarithmic corrections to the finite-size scaling are motivated and identified, which are of leading order and therefore must not be neglected. The astounding feature of these logarithmic corrections is that they do not depend at all on the model under consideration. Using the ensemble switch method, the validity of a finite-size scaling ansatz containing the aforementioned logarithmic corrections is carefully tested and confirmed. Combining the finite-size scaling theory with the ensemble switch method, the interfacial tension of several model systems, ranging from the Ising model to colloidal systems, is computed with great accuracy.
Resumo:
This study aims at a comprehensive understanding of the effects of aerosol-cloud interactions and their effects on cloud properties and climate using the chemistry-climate model EMAC. In this study, CCN activation is regarded as the dominant driver in aerosol-cloud feedback loops in warm clouds. The CCN activation is calculated prognostically using two different cloud droplet nucleation parameterizations, the STN and HYB CDN schemes. Both CDN schemes account for size and chemistry effects on the droplet formation based on the same aerosol properties. The calculation of the solute effect (hygroscopicity) is the main difference between the CDN schemes. The kappa-method is for the first time incorporated into Abdul-Razzak and Ghan activation scheme (ARG) to calculate hygroscopicity and critical supersaturation of aerosols (HYB), and the performance of the modied scheme is compared with the osmotic coefficient model (STN), which is the standard in the ARG scheme. Reference simulations (REF) with the prescribed cloud droplet number concentration have also been carried out in order to understand the effects of aerosol-cloud feedbacks. In addition, since the calculated cloud coverage is an important determinant of cloud radiative effects and is influencing the nucleation process two cloud cover parameterizations (i.e., a relative humidity threshold; RH-CLC and a statistical cloud cover scheme; ST-CLC) have been examined together with the CDN schemes, and their effects on the simulated cloud properties and relevant climate parameters have been investigated. The distinct cloud droplet spectra show strong sensitivity to aerosol composition effects on cloud droplet formation in all particle sizes, especially for the Aitken mode. As Aitken particles are the major component of the total aerosol number concentration and CCN, and are most sensitive to aerosol chemical composition effect (solute effect) on droplet formation, the activation of Aitken particles strongly contribute to total cloud droplet formation and thereby providing different cloud droplet spectra. These different spectra influence cloud structure, cloud properties, and climate, and show regionally varying sensitivity to meteorological and geographical condition as well as the spatiotemporal aerosol properties (i.e., particle size, number, and composition). The changes responding to different CDN schemes are more pronounced at lower altitudes than higher altitudes. Among regions, the subarctic regions show the strongest changes, as the lower surface temperature amplifies the effects of the activated aerosols; in contrast, the Sahara desert, where is an extremely dry area, is less influenced by changes in CCN number concentration. The aerosol-cloud coupling effects have been examined by comparing the prognostic CDN simulations (STN, HYB) with the reference simulation (REF). Most pronounced effects are found in the cloud droplet number concentration, cloud water distribution, and cloud radiative effect. The aerosol-cloud coupling generally increases cloud droplet number concentration; this decreases the efficiency of the formation of weak stratiform precipitation, and increases the cloud water loading. These large-scale changes lead to larger cloud cover and longer cloud lifetime, and contribute to high optical thickness and strong cloud cooling effects. This cools the Earth's surface, increases atmospheric stability, and reduces convective activity. These changes corresponding to aerosol-cloud feedbacks are also differently simulated depending on the cloud cover scheme. The ST-CLC scheme is more sensitive to aerosol-cloud coupling, since this scheme uses a tighter linkage of local dynamics and cloud water distributions in cloud formation process than the RH-CLC scheme. For the calculated total cloud cover, the RH-CLC scheme simulates relatively similar pattern to observations than the ST-CLC scheme does, but the overall properties (e.g., total cloud cover, cloud water content) in the RH simulations are overestimated, particularly over ocean. This is mainly originated from the difference in simulated skewness in each scheme: the RH simulations calculate negatively skewed distributions of cloud cover and relevant cloud water, which is similar to that of the observations, while the ST simulations yield positively skewed distributions resulting in lower mean values than the RH-CLC scheme does. The underestimation of total cloud cover over ocean, particularly over the intertropical convergence zone (ITCZ) relates to systematic defficiency of the prognostic calculation of skewness in the current set-ups of the ST-CLC scheme.rnOverall, the current EMAC model set-ups perform better over continents for all combinations of the cloud droplet nucleation and cloud cover schemes. To consider aerosol-cloud feedbacks, the HYB scheme is a better method for predicting cloud and climate parameters for both cloud cover schemes than the STN scheme. The RH-CLC scheme offers a better simulation of total cloud cover and the relevant parameters with the HYB scheme and single-moment microphysics (REF) than the ST-CLC does, but is not very sensitive to aerosol-cloud interactions.
Resumo:
Ein System in einem metastabilen Zustand muss eine bestimmte Barriere in derrnfreien Energie überwinden um einen Tropfen der stabilen Phase zu formen.rnHerkömmliche Untersuchungen nehmen hierbei kugelförmige Tropfen an. Inrnanisotropen Systemen (wie z.B. Kristallen) ist diese Annahme aber nicht ange-rnbracht. Bei tiefen Temperaturen wirkt sich die Anisotropie des Systems starkrnauf die freie Energie ihrer Oberfläche aus. Diese Wirkung wird oberhalb derrnAufrauungstemperatur T R schwächer. Das Ising-Modell ist ein einfaches Mo-rndell, welches eine solche Anisotropie aufweist. Wir führen großangelegte Sim-rnulationen durch, um die Effekte, die mit einer endlichen Simulationsbox ein-rnhergehen, sowie statistische Ungenauigkeiten möglichst klein zu halten. DasrnAusmaß der Simulationen die benötigt werden um sinnvolle Ergebnisse zu pro-rnduzieren, erfordert die Entwicklung eines skalierbaren Simulationsprogrammsrnfür das Ising-Modell, welcher auf verschiedenen parallelen Architekturen (z.B.rnGrafikkarten) verwendet werden kann. Plattformunabhängigkeit wird durch ab-rnstrakte Schnittstellen erreicht, welche plattformspezifische Implementierungs-rndetails verstecken. Wir benutzen eine Systemgeometrie die es erlaubt eine Ober-rnfläche mit einem variablen Winkel zur Kristallebene zu untersuchen. Die Ober-rnfläche ist in Kontakt mit einer harten Wand, wobei der Kontaktwinkel Θ durchrnein Oberflächenfeld eingestellt werden kann. Wir leiten eine Differenzialglei-rnchung ab, welche das Verhalten der freien Energie der Oberfläche in einemrnanisotropen System beschreibt. Kombiniert mit thermodynamischer Integrationrnkann die Gleichung benutzt werden, um die anisotrope Oberflächenspannungrnüber einen großen Winkelbereich zu integrieren. Vergleiche mit früheren Mes-rnsungen in anderen Geometrien und anderen Methoden zeigen hohe Überein-rnstimung und Genauigkeit, welche vor allem durch die im Vergleich zu früherenrnMessungen wesentlich größeren Simulationsdomänen erreicht wird. Die Temper-rnaturabhängigkeit der Oberflächensteifheit κ wird oberhalb von T R durch diernKrümmung der freien Energie der Oberfläche für kleine Winkel gemessen. DiesernMessung lässt sich mit Simulationsergebnissen in der Literatur vergleichen undrnhat bessere Übereinstimmung mit theoretischen Voraussagen über das Skalen-rnverhalten von κ. Darüber hinaus entwickeln wir ein Tieftemperatur-Modell fürrndas Verhalten um Θ = 90 Grad weit unterhalb von T R. Der Winkel bleibt bis zu einemrnkritischen Feld H C quasi null; oberhalb des kritischen Feldes steigt der Winkelrnrapide an. H C wird mit der freien Energie einer Stufe in Verbindung gebracht,rnwas es ermöglicht, das kritische Verhalten dieser Größe zu analysieren. Die harternWand muss in die Analyse einbezogen werden. Durch den Vergleich freier En-rnergien bei geschickt gewählten Systemgrößen ist es möglich, den Beitrag derrnKontaktlinie zur freien Energie in Abhängigkeit von Θ zu messen. Diese Anal-rnyse wird bei verschiedenen Temperaturen durchgeführt. Im letzten Kapitel wirdrneine 2D Fluiddynamik Simulation für Grafikkarten parallelisiert, welche u. a.rnbenutzt werden kann um die Dynamik der Atmosphäre zu simulieren. Wir im-rnplementieren einen parallelen Evolution Galerkin Operator und erreichen
Resumo:
Am vertikalen Windkanal der Johannes Gutenberg-Universität Mainz wurden physikalische und chemische Bereifungsexperimente durchgeführt. Dabei lagen die Umgebungstemperaturen bei allen Experimenten zwischen etwa -15 und -5°C und der Flüssigwassergehalt erstreckte sich von 0,9 bis etwa 1,6g/m³, typische Bedingungen für Mischphasenwolken in denen Bereifung stattfindet. Oberflächentemperaturmessungen an wachsenden hängenden Graupelpartikeln zeigten, dass während der Experimente trockene Wachstumsbedingungen herrschten.rnZunächst wurde das Graupelwachstum an in einer laminaren Strömung frei schwebenden Eispartikeln mit Anfangsradien zwischen 290 und 380µm, die mit flüssigen unterkühlten Wolkentröpfchen bereift wurden, studiert. Ziel war es, den Kollektionskern aus der Massenzunahme des bereiften Eispartikels und dem mittleren Flüssigwassergehalt während des Wachstumsexperimentes zu bestimmen. Die ermittelten Werte für die Kollektionskerne der bereiften Eispartikel erstreckten sich von 0,9 bis 2,3cm³/s in Abhängigkeit ihres Kollektorimpulses (Masse * Fallgeschwindigkeit des bereifenden Graupels), der zwischen 0,04 und 0,10gcm/s lag. Bei den Experimenten zeigte sich, dass die hier gemessenen Kollektionskerne höher waren im Vergleich mit Kollektionskernen flüssiger Tropfen untereinander. Aus den aktuellen Ergebnissen dieser Arbeit und der vorhandenen Literaturwerte wurde ein empirischer Faktor entwickelt, der von dem Wolkentröpfchenradius abhängig ist und diesen Unterschied beschreibt. Für die untersuchten Größenbereiche von Kollektorpartikel und flüssigen Tröpfchen können die korrigierten Kollektionskernwerte in Wolkenmodelle für die entsprechenden Größen eingebunden werden.rnBei den chemischen Experimenten zu dieser Arbeit wurde die Spurenstoffaufnahme verschiedener atmosphärischer Spurengase (HNO3, HCl, H2O2, NH3 und SO2) während der Bereifung untersucht. Diese Experimente mussten aus technischen Gründen mit hängenden Eispartikeln, dendritischen Eiskristallen und Schneeflocken, bereift mit flüssigen Wolkenlösungströpfchen, durchgeführt werden.rnDie Konzentrationen der Lösung, aus der die Wolkentröpfchen mit Hilfe von Zweistoffdüsen erzeugt wurden, lagen zwischen 1 und 120mg/l. Für die Experimente mit Ammoniak und Schwefeldioxid wurden Konzentrationen zwischen 1 und 22mg/l verwendet. Das Schmelzwasser der bereiften hängenden Graupel und Schneeflocken wurden ionenchromatographisch analysiert und zusammen mit der bekannten Konzentration der bereifenden Wolkentröpfchen konnte der Retentionskoeffizient für jeden Spurenstoff bestimmt werden. Er gibt die Menge an Spurenstoff an, die bei der Phasenumwandlung von flüssig zu fest in die Eisphase übergeht. Salpetersäure und Salzsäure waren nahezu vollständig retiniert (Mittelwerte der gesamten Experimente entsprechend 99±8% und 100±9%). Für Wasserstoffperoxid wurde ein mittlerer Retentionskoeffizient von 65±17% bestimmt. rnDer mittlere Retentionskoeffizient von Ammoniak ergab sich unabhängig vom Flüssigwassergehalt zu 92±21%, während sich für Schwefeldioxid 53±10% für niedrige und 29±7% für hohe Flüssigphasenkonzentrationen ergaben. Bei einigen der untersuchten Spurenstoffe wurde eine Temperaturabhängigkeit beobachtet und wenn möglich durch Parametrisierungen beschrieben.rn
Resumo:
Die Mikrophysik in Wolken bestimmt deren Strahlungseigenschaften und beeinflusst somit auch den Strahlungshaushalt des Planeten Erde. Aus diesem Grund werden im Rahmen der vorliegenden Arbeit die mikrophysikalischen Charakteristika von Cirrus-Wolken sowie von arktischen Grenzschicht-Wolken behandelt. Die Untersuchung dieser Wolken wurde mithilfe verschiedener Instrumente verwirklicht, welche Partikel in einem Durchmesserbereich von 250nm bis zu 6.4mm vermessen und an Forschungsflugzeugen montiert werden. Ein Instrumentenvergleich bestätigt, dass innerhalb der Bereiche in denen sich die Messungen dieser Instrumente überlappen, die auftretenden Diskrepanzen als sehr gering einzustufen sind. Das vorrangig verwendete Instrument trägt die Bezeichnung CCP (Cloud Combination Probe) und ist eine Kombination aus einem Instrument, das Wolkenpartikel anhand von vorwärts-gerichtetem Streulicht detektiert und einem weiteren, das zweidimensionale Schattenbilder einzelner Wolkenpartikel aufzeichnet. Die Untersuchung von Cirrus-Wolken erfolgt mittels Daten der AIRTOSS-ICE (AIRcraft TOwed Sensor Shuttle - Inhomogeneous Cirrus Experiment) Kampagne, welche im Jahr 2013 über der deutschen Nord- und Ostsee stattfand. Parameter wie Partikeldurchmesser, Partikelanzahlkonzentration, Partikelform, Eiswassergehalt, Wolkenhöhe und Wolkendicke der detektierten Cirrus-Wolken werden bestimmt und im Kontext des aktuellen Wissenstandes diskutiert. Des Weiteren wird eine beprobte Cirrus-Wolke im Detail analysiert, welche den typischen Entwicklungsprozess und die vertikale Struktur dieser Wolkengattung widerspiegelt. Arktische Grenzschicht-Wolken werden anhand von Daten untersucht, die während der VERDI (VERtical Distribution of Ice in Arctic Clouds) Kampagne im Jahr 2012 über der kanadischen Beaufortsee aufgezeichnet wurden. Diese Messkampagne fand im Frühling statt, um die Entwicklung von Eis-Wolken über Mischphasen-Wolken bis hin zu Flüssigwasser-Wolken zu beobachten. Unter bestimmten atmosphärischen Bedingungen tritt innerhalb von Mischphasen-Wolken der sogenannte Wegener-Bergeron-Findeisen Prozess auf, bei dem Flüssigwassertropfen zugunsten von Eispartikeln verdampfen. Es wird bestätigt, dass dieser Prozess anhand von mikrophysikalischen Messungen, insbesondere den daraus resultierenden Größenverteilungen, nachweisbar ist. Darüber hinaus wird eine arktische Flüssigwasser-Wolke im Detail untersucht, welche im Inneren das Auftreten von monomodalen Tröpfchen-Größenverteilungen zeigt. Mit zunehmender Höhe wachsen die Tropfen an und die Maxima der Größenverteilungen verschieben sich hin zu größeren Durchmessern. Dahingegen findet im oberen Übergangsbereich dieser Flüssigwasser-Wolke, zwischen Wolke und freier Atmosphäre, ein Wechsel von monomodalen zu bimodalen Tröpfchen-Größenverteilungen statt. Diese weisen eine Mode 1 mit einem Tropfendurchmesser von 20μm und eine Mode 2 mit einem Tropfendurchmesser von 10μm auf. Das dieses Phänomen eventuell typisch für arktische Flüssigwasser-Wolken ist, zeigen an dem Datensatz durchgeführte Analysen. Mögliche Entstehungsprozesse der zweiten Mode können durch Kondensation von Wasserdampf auf eingetragenen Aerosolpartikeln, die aus einer Luftschicht oberhalb der Wolke stammen oder durch Wirbel, welche trockene Luftmassen in die Wolke induzieren und Verdampfungsprozesse von Wolkentröpfchen hervorrufen, erklärt werden. Unter Verwendung einer direkten numerischen Simulation wird gezeigt, dass die Einmischung von trockenen Luftmassen in den Übergangsbereich der Wolke am wahrscheinlichsten die Ausbildung von Mode 2 verursacht.
Resumo:
In der Form von Nanokapseln (AmB-HST), Nanoemulsion beziehungsweise multilamellaren Vesikeln (MLV) wurden drei Amphotericin-B-Formulierungen für die orale Applikation entwickelt, charakterisiert und verglichen. Die neuartige homogene Nanokapsel-Formulierung des hydrophoben Polyen-Antimykotikums Amphotericin B wurde in Analogie zu einem für Simvastatin und andere Arzneistoffe etablierten Prozess aus der Reinsubstanz, Lezithin und Gelatine mit Hilfe des HST-Verfahrens hergestellt. Photometrische Untersuchungen zeigten, dass das Endprodukt aus Monomeren aufgebaut ist. Mittels Mikroskopie ließen sich die Aggregate vor der Umhüllung mit Lezithin und Gelatine im Ausgangsmaterial als individuelle kugelförmige Arzneistoffpartikel darstellen. Strukturuntersuchungen mit dynamischer licht streuung (DLS) zeigten eine enge Größenverteilung der verkapselten Partikel von ca. 1 µm. Die Struktur der Hülle der HST-Partikel wurde erstmalig mit Neutronenstreuung unter Verwendung der Deuterium-basierten Lösungsmittel kontrastmethode aufgeklärt. Durch die teilweise Kontrastmaskierung des Partikelkerns bei der Neutronenstreuung konnte die Lezithin-Gelatine-Hülle als eine dünne, 5,64 ± 0.18 nm dicke Schicht aufgelöst werden, welche der biologischen Lipidmembran ähnlich, im Vergleich aber geringfügig größer ist. Dieses Resultat eröffnet Wege für die Optimierung der Formulierung von pharmazeutischen Nanopartikeln, z.B. durch Oberflächenmodifizierungen. Weitere Untersuchungen mittels Kleinwinkelneutronenstreuung unter Verwendung der D-Kontrastvariation deuten darauf hin, dass die Komponenten der Nanokapseln nicht den gleichen Masseschwerpunkt haben, sondern asymmetrisch aufgebaut sind und dass die stärker streuenden Domänen weiter außen liegen. Die Partikel sind im Vergleich zu Liposomen dichter. In-Vitro Freisetzungsstudien belegen das Solubilisierungsvermögen des HST-Systems, wonach die Freisetzung des Arzneistoffes aus der Formulierung zu allen gemessenen Zeitpunkten höher als diejenige der Reinsubstanz war. rnDie Nanoemulsion-Formulierung von Amphotericin B wurde mit einem Öl und Tensid system, jedoch mit unterschiedlichen Co-Solvenzien, erfolgreich entwickelt. Gemäß der Bestimmung der Löslichkeit in verschiedenen Hilfsstoffen erwies sich der Arzneistoff Amphotericin B als nicht-lipophil, gleichzeitig aber auch als nicht-hydrophil. Die zur Ermittlung der für die Emulsionsbildung notwendigen Hilfstoffkonzentrationen erstellten ternären Diagramme veranschaulichten, dass hohe Öl- und Tensidgehalte zu keiner Emulsionsbildung führten. Dementsprechend betrug der höchste Ölgehalt 10%. Die Tröpfchengröße wuchs mit zunehmender Tensidkonzentration, wobei die Co-Solventmenge der Propylenglykol-haltigen Nanoemulsion indirekt verringert wurde. Für die Transcutol®P-haltige Nanoemulsion hingegen wurde das Gegenteil beobachtet, nämlich eine Abnahme der Tröpfchengröße bei steigenden Tensidkonzentrationen. Durch den Einschluss des Arzneistoffes wurde nicht die Viskosität der Formulierung, sondern die Tröpfchengröße beeinflusst. Der Wirkstoffeinschluss führte zu höheren Tröpfchengrößen. Mit zunehmender Propylenglykolkonzentration wurde der Wirkstoffgehalt erhöht, mit zunehmender Transcutol®P-Konzentration dagegen vermindert. UV/VIS-spektroskopische Analysen deuten darauf hin, dass in beiden Formulierungen Amphotericin B als Monomer vorliegt. Allerdings erwiesen sich die Formulierungen Caco-2-Zellen und humanen roten Blutkörperchen gegenüber als toxisch. Da die Kontrollproben eine höhere Toxizität als die wirkstoffhaltigen Formulierungen zeigten, ist die Toxizität nicht nur auf Amphotericin, sondern auch auf die Hilfsstoffe zurückzuführen. Die solubilisierte Wirkstoffmenge ist in beiden Formulierungen nicht ausreichend im Hinblick auf die eingesetzte Menge an Hilfsstoff nach WHO-Kriterien. Gemäß diesen Untersuchungen erscheinen die Emulsions-Formulierungen für die orale Gabe nicht geeignet. Dennoch sind Tierstudien notwendig, um den Effekt bei Tieren sowie die systemisch verfügbare Wirkstoffmenge zu ermitteln. Dies wird bestandskräftige Schlussfolgerungen bezüglich der Formulierung und Aussagen über mögliche Perspektiven erlauben. Nichtsdestotrotz sind die Präkonzentrate sehr stabil und können bei Raumtemperatur gelagert werden.rnDie multilamellar-vesikulären Formulierungen von Amphotericin B mit ungesättigten und gesättigten neutralen Phospholipiden und Cholesterin wurden erfolgreich entwickelt und enthielten nicht nur Vesikel, sondern auch zusätzliche Strukturen bei zunehmender Cholesterinkonzentration. Mittels Partikelgrößenanalyse wurden bei den Formulierungen mit gesättigten Lipiden Mikropartikel detektiert, was abhängig von der Alkylkettenlänge war. Mit dem ungesättigten Lipid (DOPC) konnten hingegen Nanopartikel mit hinreichender Verkapselung und Partikelgrößenverteilung gebildet werden. Die Ergebnisse der thermischen und FTIR-spektroskopischen Analyse, welche den Einfluss des Arzneistoffes ausschließen ließen, liefern den Nachweis für die mögliche, bereits in der Literatur beschriebene Einlagerung des Wirkstoffs in lipid- und/oder cholesterinreiche Membranen. Mit Hilfe eines linearen Saccharosedichtegradienten konnte die Formulierung in Vesikel und Wirkstoff-Lipid-Komplexe nach bimodaler Verteilung aufgetrennt werden, wobei der Arzneistoff stärker mit den Komplexen als mit den Vesikeln assoziiert ist. Bei den Kleinwinkelneutronenstreu-Experimenten wurde die Methode der Kontrastvariation mit Erfolg angewendet. Dabei konnte gezeigt werden, dass Cholesterol in situ einen Komplex mit Amphotericin B bildet. Diesen Sachverhalt legt unter anderem die beobachtete Differenz in der äquivalenten Streulängendichte der Wirkstoff-Lipid- und Wirkstoff-Lipid-Cholesterin-haltigen kleinen unilamellaren Vesikeln nahe. Das Vorkommen von Bragg-Peaks im Streuprofil weist auf Domänen hin und systematische Untersuchungen zeigten, dass die Anzahl der Domänen mit steigendem Cholesteringehalt zunimmt, ab einem bestimmten Grenzwert jedoch wieder abnimmt. Die Domänen treten vor allem nahe der Außenfläche der Modellmembran auf und bestätigen, dass der Wirkstoff in den Cholesterinreichen Membranen vertikal eingelagert ist. Die Formulierung war sowohl Caco-2-Zellen als auch humanen roten Blutkörperchen gegenüber nicht toxisch und erwies sich unter Berücksichtigung der Aufnahme in Caco-2-Zellen als vielversprechend für die orale Applikation. Die Formulierung zeigt sich somit aussichtsreich und könnte in Tabletten weiterverarbeitet werden. Ein Filmüberzug würde den Wirkstoff gegen die saure Umgebung im Magen schützen. Für die Bestimmung der systemischen Verfügbarkeit der Formulierung sind Tierstudien notwendig. Die entwickelten multilamellaren Formulierungen einschließlich der Wirkstoff-Cholesterin-Komplexe bieten somit gute Aussichten auf die mögliche medizinische Anwendung. rnrn