122 resultados para Power delivery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focus of this thesisis made on development of electricity sector of Russian North-West. The objective was to determine the most likely scenarios for development of the most critical (western) part of Interregional Power System of North-West, from where the most part of Russian electricity exports to the countries of European Union take place. For this purpose all the involved sides were analyzed: generation, transmission system and electricity consumption in different regions of Russian North-West. The analysis was performed through investigation of existing generation andtransmission capacities and plans for their development to be performed by the generation and transmission companies operating in the region. Principles of Russian electricity sector restructuring and electricity market design are also discussed as well as factors that may influence on future electricity price in the region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työn tarkoituksena on tarkastella Euroopan siirtymätalousalueelta kotimaisen biopoltto-ainevoimalaitoksen kilpailukykyä potentiaalisimmiksi markkinakohteiksi arvioitujen nykyisten Eu-valtioiden osalta. Työ tehdään osana kokoluokaltaan 3,5 MWth/1,0 MWe pienvoimalaitoksen tuotekehityshanketta, joka on käynnistynyt Varkaudessa tämän vuoden maaliskuussa. Potentiaalisimpien siirtymätalousmaiden valintakriteereinä on käytetty aiempia tutkimuksia ja raportteja. Huomio keskitetään kiinteän biopolttoaineen resursseihin ja biopolttoaineisiin pohjautuvalle energiantuotannolle asetettuihin tavoitteisiin. Edellä mainittujen kriteerien pohjalta tarkasteltaviksi valittujen valtioiden osalta tehtiin tarkemmat kilpailukykyanalyysit, otettiin yhteyttä markkina-alueeltaalan ammattilaisiin ja kartoitettiin potentiaalisimmat markkinakohteet. Tavoitteena on arvioida varteenotettavin kilpailija kiinteisiin biopolttoaineisiin pohjautuvalle sähkön ja lämmön yhteistuotannolle, jonka perusteella laaditaan mallivoimalaitoksen kilpailukykyisen hinnan määrittämiseksi tiettyyn takaisinmaksuaikaan ja korkotekijään perustuen. Lopulta tehdään maakohtaisesti yhteenveto merkittävimmistä markkinapotentiaaliin vaikuttavista kilpailutekijöistä, arvioidaan potentiaalisin kohdemaa sekä esitetään mahdollinen investoinnin rahoitusvaihtoehto ja keinoja markkinoida tuotetta potentiaalisille asiakkaille.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Kioton pöytäkirja velvoittaa teollisuusmaita vähentämään hiilidioksidipäästöjään. Energiantuotantolaitosten on vähennettävä tuotantoaan tai siirryttävä käyttämään vähäpäästöisempiä polttoaineita vähennystavoitteiden saavuttamiseksi. Etelä-Savon Energia Oy Mikkelissä rakentaa uuden kattilalaitoksen, joka soveltuu hiilidioksidivapaiden puupolttoaineiden polttoon. Kun uusi kattilalaitos otetaan käyttöön, kasvaa voimalaitoksen polttoaineiden kulutus 1,7 -kertaiseksi. Tämä merkitsee laitokselle tulevien polttoainekuljetusten määrän kasvamista kylmimpinä aikoina yli 70:neen autoon vuorokaudessa. Työssä on tarkasteltu nykyisen polttoaineiden vastaanoton ja kuljettimien kykyä ottaa vastaan kasvavat polttoainevirrat. Vastaanoton sujuvuus on polttoaineiden laadunhallinnan lisäksi edellytys laitoksen käytölle. Työn tavoitteena on ollut kartoittaa vastaanoton ongelmakohtia ja löytää näihin parannusmahdollisuuksia. Vastaanottokapasiteetti tulee venymään äärimmilleen tulevaisuudessa. Jotta määrällisesti riittävä ja laadullisesti sopiva polttoaineseos saadaan vastaanotettua nykyisenä vastaanottoaikana, tulee autojen saapua entistä tasaisemmin laitokselle. Tasainen saapuminen on mahdollista aikatauluttamalla sopivasti polttoainekuljetusten saapumisajat laitokselle. Vastaanoton kapasiteettia voitaisiin nostaa kasvattamalla kenttävaraston kokoa ja pienillä muutoksilla vastaanottoasemissa. Polttoaineen laadun ja vastaanoton tarkastelun lisäksi työssä on tarkasteltu polttoaineen saatavuutta.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena on selvittää Wärtsilän dieselvoimalaitosten jätevedenkäsittelyn vallitseva tila. Tutkimuksessa keskitytään raskaspolttoöljykäyttöisiin voimalaitoksiin. Työssä selvitetään yleisimmät dieselvoimalaitosten jätevesille asetetut vaatimukset. Selvitys tehdään keräämälläja tutkimalla dieselvoimalaitosten jätevesille sovellettuja standardeja. Työssä selvitetään myös dieselvoimalaitokselta ulostulevan jäteveden laatu sekä nykyisen jätevedenkäsittelyjärjestelmän toiminta. Selvitys tehdään keräämällä ja tutkimalla yrityksen sisäisiä tietoja, sekä ottamalla ja analysoimalla jätevesinäytteitä. Näytteiden otto ja analysointi toteutetaan vierailemallakahdessa voimalaitoksessa sekä yhdessä muussa kohteessa. Jäteveden laatu ennen ja jälkeen käsittelyn määritetään. Myös öljynjalostusteollisuuden jätevedenkäsittelyä tarkastellaan kirjallisuuteen pohjautuen. Tarkastelun tavoitteena on hankkia tietoa jätevedenkäsittelystä kohteissa, joissa jäteveden laatu vastaa dieselvoimalaitoksella syntyvää jätevettä. Vertailun vuoksi myös öljynjalostusteollisuudelle asetetuttuja jätevesistandardeja tutkitaan. Lisäksi työssä tutkitaan myös joitakin muita jätevedenkäsittelymenetelmiä. Diplomityön tuloksena määritetään dieselvoimalaitosten jätevedenkäsittelyn tulevaisuuden haasteet ja mahdollisuudet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Globaalin talouden rakenteet muuttuvat jatkuvasti. Yritykset toimivat kansainvälisillä markkinoilla aiempaa enemmän. Tuotannon lisäämiseksi monet yritykset ovat ulkoistaneet tuotteidensa tuki- ja ylläpitotoiminnot halvan työvoiman maihin. Yritykset voivat tällöin keskittää toimintansa ydinosamiseensa. Vapautuneita resursseja voidaan käyttää yrityksen sisäisessä tuotekehityksessä ja panostaa seuraavan sukupolven tuotteiden ja teknologioiden kehittämiseen. Diplomityö esittelee Globaalisti hajautetun toimitusmallin Internet-palveluntarjoajalle jossa tuotteiden tuki- ja ylläpito on ulkoistettu Intiaan. Teoriaosassa esitellään erilaisia toimitusmalleja ja keskitytään erityisesti hajautettuun toimitusmalliin. Tämän lisäksi luetellaan valintakriteerejä joilla voidaan arvioida projektin soveltuvuutta ulkoistettavaksi sekä esitellään mahdollisuuksia ja uhkia jotka sisältyvät globaaliin ulkoistusprosessiin. Käytäntöosassa esitellään globaali palvelun toimittamisprosessi joka on kehitetty Internet-palveluntarjoajan tarpeisiin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ydinvoimalaitokset on suunniteltu ja rakennettu niin, että niillä on kyky selviytyä erilaisista käyttöhäiriöistä ja onnettomuuksista ilman laitoksen vahingoittumista sekä väestön ja ympäristön vaarantumista. On erittäin epätodennäköistä, että ydinvoimalaitosonnettomuus etenee reaktorisydämen vaurioitumiseen asti, minkä seurauksena sydänmateriaalien hapettuminen voi tuottaa vetyä. Jäädytyspiirin rikkoutumisen myötä vety saattaa kulkeutua ydinvoimalaitoksen suojarakennukseen, jossa se voi muodostaa palavan seoksen ilman hapen kanssa ja palaa tai jopa räjähtää. Vetypalosta aiheutuvat lämpötila- ja painekuormitukset vaarantavat suojarakennuksen eheyden ja suojarakennuksen sisällä olevien turvajärjestelmien toimivuuden, joten tehokas ja luotettava vedynhallintajärjestelmä on tarpeellinen. Passiivisia autokatalyyttisiä vetyrekombinaattoreita käytetäänyhä useammissa Euroopan ydinvoimaitoksissa vedynhallintaan. Nämä rekombinaattorit poistavat vetyä katalyyttisellä reaktiolla vedyn reagoidessa katalyytin pinnalla hapen kanssa muodostaen vesihöyryä. Rekombinaattorit ovat täysin passiivisiaeivätkä tarvitse ulkoista energiaa tai operaattoritoimintaa käynnistyäkseen taitoimiakseen. Rekombinaattoreiden käyttäytymisen tutkimisellatähdätään niiden toimivuuden selvittämiseen kaikissa mahdollisissa onnettomuustilanteissa, niiden suunnittelun optimoimiseen sekä niiden optimaalisen lukumäärän ja sijainnin määrittämiseen suojarakennuksessa. Suojarakennuksen mallintamiseen käytetään joko keskiarvoistavia ohjelmia (Lumped parameter (LP) code), moniulotteisia virtausmalliohjelmia (Computational Fluid Dynamics, CFD) tai näiden yhdistelmiä. Rekombinaattoreiden mallintaminen on toteutettu näissä ohjelmissa joko kokeellisella, teoreettisella tai yleisellä (eng. Global Approach) mallilla. Tämä diplomityö sisältää tulokset TONUS OD-ohjelman sisältämän Siemens FR90/1-150 rekombinaattorin mallin vedynkulutuksen tarkistuslaskuista ja TONUS OD-ohjelmalla suoritettujen laskujen tulokset Siemens rekombinaattoreiden vuorovaikutuksista. TONUS on CEA:n (Commissariat à 1'En¬ergie Atomique) kehittämä LP (OD) ja CFD -vetyanalyysiohjelma, jota käytetään vedyn jakautumisen, palamisenja detonaation mallintamiseen. TONUS:sta käytetään myös vedynpoiston mallintamiseen passiivisilla autokatalyyttisillä rekombinaattoreilla. Vedynkulutukseen vaikuttavat tekijät eroteltiin ja tutkittiin yksi kerrallaan. Rekombinaattoreiden vuorovaikutuksia tutkittaessa samaan tilavuuteen sijoitettiin eri kokoisia ja eri lukumäärä rekombinaattoreita. Siemens rekombinaattorimalli TONUS OD-ohjelmassa laskee vedynkulutuksen kuten oletettiin ja tulokset vahvistavat TONUS OD-ohjelman fysikaalisen laskennan luotettavuuden. Mahdollisia paikallisia jakautumia tutkitussa tilavuudessa ei voitu havaita LP-ohjelmalla, koska se käyttäälaskennassa suureiden tilavuuskeskiarvoja. Paikallisten jakautumien tutkintaan tarvitaan CFD -laskentaohjelma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diplomityön tavoitteena oli kehittää Fazer Suklaan oston tilaus-toimitusprosesseja, jotta raaka-aineet ja pakkausmateriaalit pystytään hoitamaan mahdollisimman tehokkaasti. Ensin selvitettiin kirjallisuuden avulla tilaus-toimitusprosessin päävaiheet ja niihin vaikuttavat tekijät. Empiirisessä osassa lähdettiin liikkeelle käymällä läpi Fazer Suklaan oston nykytilanne, joka tehtiin ostajille suunnatun aikaselvityksen, haastatteluiden ja nykyisten tilaus-toimitusprosessien kuvaamisen avulla. Tavoitetilanteen rakentaminen aloitettiin ostettavien materiaalien ja toimittajien luokittelemisella. Tämän perusteella nämä materiaalit voitiin jakaa kolmen eri tilaus toimitusprosessin alle. Automaattisessa tilaus-toimitusprosessissa eri vaiheet automatisoidaan yhdessäavain toimittajien kanssa. Puoliautomaattinen prosessi perustuu systeemiin, jossa toimittaja näkee internetin kautta Fazerin tuotantosuunnitelman ja tekee tämän perusteella materiaalien täydennykset. Yksinkertaisessa prosessissa ostoarvoltaan alhaiset materiaalit hoidetaan mahdollisimman lähellä käyttöpistettä ja prosessin vaiheet tehdään mandollisimman pienellä työmäärällä. Tavoiteprosessien implementoinnilla todettiin suurimmiksi eduiksi prosessivaiheiden vähentyminen ja manuaalisen työn automatisoituminen. Tätä kautta saatiin prosessin eri vaiheiden työmäärää vähennettyä, sekä alennettua varastotasoja ja näin tilaus toimitusprosessin kokonaiskustannuksia pystyttiin pienentämään.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimus pyrkii selvittämään, kuinka tehokas suorituskykymittaristo voidaan parhaiten suunnitella pk-yrityksessä. Tutkimuksen tavoitteena on luoda suorituskykymittaristo pienen kohdeyrityksen johtajien tarpeisiin. Päähuomion kohteena on yrityksen tilaus-toimitusketju ja arvoverkko. Työ on luonteeltaan kvalitatiivinen toimintatutkimus, joka noudattaa toiminta-analyyttista tutkimusotetta. Työn teoriaosassa selvitetään, kuinka suorituskyvyn mittaaminen sekä materiaali-, tieto- ja rahavirtojen hallinta on kehittynyt viime vuosina pk-yrityksen näkökulmasta. Mittariston suunnittelu aloitetaan kohdeyrityksen perusteellisella analyysilla. Tämän pohjalta määritellään yrityksen kriittiset menestystekijät, joista lopulta johdetaan suorituskykymittarit. Tutkimuksen perusteella voidaan todeta, että yleinen asenne mittaamista kohtaan, strategian huomioinnin puute sekä tietojärjestelmien rajoitteet ovat päähaasteita pk-yrityksen suorituskyvyn mittaamisessa. Mittareiden tuleekin olla melko yksinkertaisia ja helppoja käyttää, jotta mittaamisen ei koettaisi kuluttavan rajallisia resursseja liikaa. Mittariston tulee kuitenkin antaa kokonaisvaltainen kuva yrityksen suorituskyvystä, johon vaikuttavat kaikki arvoverkon osapuolet ja heidän yhteistyö toistensa kanssa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tutkimuksen pääasiallisena tavoitteena on selvittää ne moninaiset näkökulmat, joita mentori sekä mentoroitava läpikäyvät osallistuessaan mentorointiohjelmaan. Tutkimuksen avulla pyritään myös selvittämään vastaavanlaisen tuen saannin tehokkuutta sekä mentoroinnin sisältäminen elementtien hyödyllisyyttä. Pyrkimyksenä on myös selvittää sekä ymmärtää ne dynaamiset mentorointiprosessin ominaisuudet molempien prosessiin osallistuvien tahojen näkökulmasta. Tutkimuksen teoriaosuudessa käsitellään mentorointia, mentorointiin liittyviä vuorovaikutussuhteita sekä näihin liittyviä eri näkökulmia. Teoria koostuu monipuolisesta, kansainvälisestä sekä kotimaisesta kirjallisuudesta. Tutkimuksen aineiston keruu suoritetaan puolistrukturoiduilla avoimilla haastatteluilla, jotka suoritetaan järjestämällä kahdenkeskisiä teemahaastatteluita. Mentorointisuhteella on todettu olevan voimakas vaikutus siihen osallistuvien henkilöiden elämään. Mentorointisuhteen tarkoituksellisuus on tullut todettua myös kun itse vuorovaikutussuhde on osoittautunut hyödylliseksi osallistujille. Mentoroitavilla on odotuksia, että mentorit täyttävät seuraavanlaisia rooleja: neuvonantaja, roolimalli sekä mahdollisesti tukea antava ystävä. Kaikissa läpikäydyissä tapauksissa mentori pystyi tarjoamaan jonkun näistärooleista mentoroitavalle. Mentoroitava, puolestaan, otti tämän tuen vastaan jahyötyi siitä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tehoelektoniikkalaitteella tarkoitetaan ohjaus- ja säätöjärjestelmää, jolla sähköä muokataan saatavilla olevasta muodosta haluttuun uuteen muotoon ja samalla hallitaan sähköisen tehon virtausta lähteestä käyttökohteeseen. Tämä siis eroaa signaalielektroniikasta, jossa sähköllä tyypillisesti siirretään tietoa hyödyntäen eri tiloja. Tehoelektroniikkalaitteita vertailtaessa katsotaan yleensä niiden luotettavuutta, kokoa, tehokkuutta, säätötarkkuutta ja tietysti hintaa. Tyypillisiä tehoelektroniikkalaitteita ovat taajuudenmuuttajat, UPS (Uninterruptible Power Supply) -laitteet, hitsauskoneet, induktiokuumentimet sekä erilaiset teholähteet. Perinteisesti näiden laitteiden ohjaus toteutetaan käyttäen mikroprosessoreja, ASIC- (Application Specific Integrated Circuit) tai IC (Intergrated Circuit) -piirejä sekä analogisia säätimiä. Tässä tutkimuksessa on analysoitu FPGA (Field Programmable Gate Array) -piirien soveltuvuutta tehoelektroniikan ohjaukseen. FPGA-piirien rakenne muodostuu erilaisista loogisista elementeistä ja niiden välisistä yhdysjohdoista.Loogiset elementit ovat porttipiirejä ja kiikkuja. Yhdysjohdot ja loogiset elementit ovat piirissä kiinteitä eikä koostumusta tai lukumäärää voi jälkikäteen muuttaa. Ohjelmoitavuus syntyy elementtien välisistä liitännöistä. Piirissä on lukuisia, jopa miljoonia kytkimiä, joiden asento voidaan asettaa. Siten piirin peruselementeistä voidaan muodostaa lukematon määrä erilaisia toiminnallisia kokonaisuuksia. FPGA-piirejä on pitkään käytetty kommunikointialan tuotteissa ja siksi niiden kehitys on viime vuosina ollut nopeaa. Samalla hinnat ovat pudonneet. Tästä johtuen FPGA-piiristä on tullut kiinnostava vaihtoehto myös tehoelektroniikkalaitteiden ohjaukseen. Väitöstyössä FPGA-piirien käytön soveltuvuutta on tutkittu käyttäen kahta vaativaa ja erilaista käytännön tehoelektroniikkalaitetta: taajuudenmuuttajaa ja hitsauskonetta. Molempiin testikohteisiin rakennettiin alan suomalaisten teollisuusyritysten kanssa soveltuvat prototyypit,joiden ohjauselektroniikka muutettiin FPGA-pohjaiseksi. Lisäksi kehitettiin tätä uutta tekniikkaa hyödyntävät uudentyyppiset ohjausmenetelmät. Prototyyppien toimivuutta verrattiin vastaaviin perinteisillä menetelmillä ohjattuihin kaupallisiin tuotteisiin ja havaittiin FPGA-piirien mahdollistaman rinnakkaisen laskennantuomat edut molempien tehoelektroniikkalaitteiden toimivuudessa. Työssä on myösesitetty uusia menetelmiä ja työkaluja FPGA-pohjaisen säätöjärjestelmän kehitykseen ja testaukseen. Esitetyillä menetelmillä tuotteiden kehitys saadaan mahdollisimman nopeaksi ja tehokkaaksi. Lisäksi työssä on kehitetty FPGA:n sisäinen ohjaus- ja kommunikointiväylärakenne, joka palvelee tehoelektroniikkalaitteiden ohjaussovelluksia. Uusi kommunikointirakenne edistää lisäksi jo tehtyjen osajärjestelmien uudelleen käytettävyyttä tulevissa sovelluksissa ja tuotesukupolvissa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study focuses on two effects of the presence of a noncondensable gas on the thermal-hydraulic behavior of thecoolant of the primary circuit of a nuclear reactor in the VVER-440 geometry inabnormal situations. First, steam condensation with the presence of air was studied in the horizontal tubes of the steam generator (SG) of the PACTEL test facility. The French thermal-hydraulic CATHARE code was used to study the heat transfer between the primary and secondary side in conditions derived from preliminary experiments performed by VTT using PACTEL. In natural circulation and single-phase vapor conditions, the injection of a volume of air, equivalent to the totalvolume of the primary side of the SG at the entrance of the hot collector, did not stop the heat transfer from the primary to the secondary side. The calculated results indicate that air is located in the second half-length (from the mid-length of the tubes to the cold collector) in all the tubes of the steam generator The hot collector remained full of steam during the transient. Secondly, the potential release of the nitrogen gas dissolved in the water of the accumulators of the emergency core coolant system of the Loviisa nuclear power plant (NPP) was investigated. The author implemented a model of the dissolution and release ofnitrogen gas in the CATHARE code; the model created by the CATHARE developers. In collaboration with VTT, an analytical experiment was performed with some components of PACTEL to determine, in particular, the value of the release time constant of the nitrogen gas in the depressurization conditions representative of the small and intermediate break transients postulated for the Loviisa NPP. Such transients, with simplified operating procedures, were calculated using the modified CATHARE code for various values of the release time constant used in the dissolution and release model. For the small breaks, nitrogen gas is trapped in thecollectors of the SGs in rather large proportions. There, the levels oscillate until the actuation of the low-pressure injection pumps (LPIS) that refill the primary circuit. In the case of the intermediate breaks, most of the nitrogen gas is expelled at the break and almost no nitrogen gas is trapped in the SGs. In comparison with the cases calculated without taking into account the release of nitrogen gas, the start of the LPIS is delayed by between 1 and 1.75 h. Applicability of the obtained results to the real safety conditions must take into accountthe real operating procedures used in the nuclear power plant.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The research of power-line communications has been concentrated on home automation, broadband indoor communications and broadband data transfer in a low voltage distribution network between home andtransformer station. There has not been carried out much research work that is focused on the high frequency characteristics of industrial low voltage distribution networks. The industrial low voltage distribution network may be utilised as a communication channel to data transfer required by the on-line condition monitoring of electric motors. The advantage of using power-line data transfer is that it does not require the installing of new cables. In the first part of this work, the characteristics of industrial low voltage distribution network components and the pilot distribution network are measured and modelled with respect topower-line communications frequencies up to 30 MHz. The distributed inductances, capacitances and attenuation of MCMK type low voltage power cables are measured in the frequency band 100 kHz - 30 MHz and an attenuation formula for the cables is formed based on the measurements. The input impedances of electric motors (15-250 kW) are measured using several signal couplings and measurement based input impedance model for electric motor with a slotted stator is formed. The model is designed for the frequency band 10 kHz - 30 MHz. Next, the effect of DC (direct current) voltage link inverter on power line data transfer is briefly analysed. Finally, a pilot distribution network is formed and signal attenuation in communication channels in the pilot environment is measured. The results are compared with the simulations that are carried out utilising the developed models and measured parameters for cables and motors. In the second part of this work, a narrowband power-line data transfer system is developed for the data transfer ofon-line condition monitoring of electric motors. It is developed using standardintegrated circuits. The system is tested in the pilot environment and the applicability of the system for the data transfer required by the on-line condition monitoring of electric motors is analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Control applications of switched mode power supplies have been widely investigated. The main objective ofresearch and development (R&D) in this field is always to find the most suitable control method to be implemented in various DC/DC converter topologies. Inother words, the goal is to select a control method capable of improving the efficiency of the converter, reducing the effect of disturbances (line and load variation), lessening the effect of EMI (electro magnetic interference), and beingless effected by component variation. The main objective of this research work is to study different control methods implemented in switched mode power supplies namely (PID control, hysteresis control, adaptive control, current programmed control, variable structure control (VSC), and sliding mode control (SMC). The advantages and drawbacks of each control method are given. Two control methods, the PID and the SMC are selected and their effects on DC/DC (Buck, Boost, and Buck-Boost) converters are examined. Matlab/SimulinkTM is used to implement PID control method in DC/DC Buck converter and SMC in DC/DC (Buck, and Buck Boost) converters. For the prototype, operational amplifiers (op-amps) are used to implement PID control in DC/DC Buck converter. For SMC op-amps are implemented in DC/DC Buck converter and dSPACETM is used to control the DC/DC Buck-Boost converter. The SMC can be applied to the DC/DC (Buck, Boost, and Buck-Boost) converters. A comparison of the effects of the PID control and the SMC on the DC/DC Buck converter response in steady state, under line variations, load variations, and different component variations is performed. Also the Conducted RF-Emissions between the PID and SMC DC/DC Buck Converter are compared. The thesis shows that, in comparison with the PID control, the SMC provides better steady-state response, better dynamic response, less EMI, inherent order reduction, robustness against system uncertainty disturbances, and an implicit stability proof. Giving a better steady-state and dynamic response, the SMC is implemented in a DC/DC resonant converter. The half-wave zero current switching (HWZCS) DC/DC Buck converter is selected as a converter topology. A general guideline to select the tank component values, needed for the designing of a HWZCS DC/DC Buck, is obtained. The implementation of the SMC to a HWZCS DC/DC Buck converter is analysed. The converter response is investigated in the steady-state region and in the dynamic region.