39 resultados para Portuguese managers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivations/barriers to participate in ITF

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coal contains trace quantities of natural radionuclides such as Th-232, U-235, U-238, as well as their radioactive decay products and 40K. These radionuclides can be released as fly ash in atmospheric emissions from coal-fired power plants, dispersed into the environment and deposited on the surrounding top soils. Therefore, the natural radiation background level is enhanced and consequently increase the total dose for the nearby population. A radiation monitoring programme was used to assess the external dose contribution to the natural radiation background, potentially resulting from the dispersion of coal ash in past atmospheric emissions. Radiation measurements were carried out by gamma spectrometry in the vicinity of a Portuguese coal-fired power plant. The radiation monitoring was achieved both on and off site, being the boundary delimited by a 20 km circle centered in the stacks of the coal plant. The measured radionuclides concentrations for the uranium and thorium series ranged from 7.7 to 41.3 Bq/kg for Ra-226 and from 4.7 to 71.6 Bq/kg for Th-232, while K-40 concentrations ranged from 62.3 to 795.1 Bq/kg. The highest values were registered near the power plant and at distances between 6 and 20 km from the stacks, mainly in the prevailing wind direction. The absorbed dose rates were calculated for each sampling location: 13.97-84.00 ηGy/h, while measurements from previous studies carried out in 1993 registered values in the range of 16.6-77.6 ηGy/h. The highest values were registered at locations in the prevailing wind direction (NW-SE). This study has been primarily done to assess the radiation dose rates and exposure to the nearby population in the surroundings of a coal-fired power plant. The results suggest an enhancement or at least an influence in the background radiation due to the coal plant past activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Trabalho de Projeto apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria Orientação: Doutora Alcina Augusta de Sena Portugal Dias Coorientação: Doutora Amélia Cristina Ferreira Silva

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hospitals are considered as a special and important type of indoor public place where air quality has significant impacts on potential health outcomes. Information on indoor air quality of these environments, concerning exposures to particulate matter (PM) and related toxicity, is limited though. This work aims to evaluate risks associated with inhalation exposure to ten toxic metals and chlorine (As, Ni, Cr, Cd, Pb, Mn, Se, Ba, Al, Si, and Cl) in coarse (PM2.5–10) and fine (PM2.5) particles in a Portuguese hospital in comparison with studies representative of other countries. Samples were collected during 1 month in one urban hospital; elemental PM characterization was determined by proton-induced X-ray emission. Noncarcinogenic and carcinogenic risks were assessed according to the methodology provided by the United States Environmental Protection Agency (USEPA; Region III Risk-Based Concentration Table) for three different age categories of hospital personnel (adults, >20, and <65 years) and patients (considering nine different age groups, i.e., children of 1–3 years to seniors of >65 years). The estimated noncarcinogenic risks due to occupational inhalation exposure to PM2.5-bound metals ranged from 5.88×10−6 for Se (adults, 55–64 years) to 9.35×10−1 for As (adults, 20–24 years) with total noncarcinogenic risks (sum of all metals) above the safe level for all three age categories. As and Cl (the latter due to its high abundances) were the most important contributors (approximately 90 %) to noncarcinogenic risks. For PM2.5–10, noncarcinogenic risks of all metals were acceptable to all age groups. Concerning carcinogenic risks, for Ni and Pb, they were negligible (<1×10−6) in both PM fractions for all age groups of hospital personnel; potential risks were observed for As and Cr with values in PM2.5 exceeding (up to 62 and 5 times, respectively) USEPA guideline across all age groups; for PM2.5–10, increased excess risks of As and Cr were observed particularly for long-term exposures (adults, 55–64 years). Total carcinogenic risks highly (up to 67 times) exceeded the recommended level for all age groups, thus clearly showing that occupational exposure to metals in fine particles pose significant risks. If the extensive working hours of hospital medical staff were considered, the respective noncarcinogenic and carcinogenic risks were increased, the latter for PM2.5 exceeding the USEPA cumulative guideline of 10−4. For adult patients, the estimated noncarcinogenic and carcinogenic risks were approximately three times higher than for personnel, with particular concerns observed for children and adolescents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work was to assess ultrafine particles (UFP) number concentrations in different microenvironments of Portuguese preschools and to estimate the respective exposure doses of UFP for 3–5-year-old children (in comparison with adults). UFP were sampled both indoors and outdoors in two urban (US1, US2) and one rural (RS1) preschool located in north of Portugal for 31 days. Total levels of indoor UFP were significantly higher at the urban preschools (mean of 1.82x104 and 1.32x104 particles/cm3 at US1 an US2, respectively) than at the rural one (1.15x104 particles/cm3). Canteens were the indoor microenvironment with the highest UFP (mean of 5.17x104, 3.28x104, and 4.09x104 particles/cm3 at US1, US2, and RS1), whereas the lowest concentrations were observed in classrooms (9.31x103, 11.3x103, and 7.14x103 particles/cm3 at US1, US2, and RS1). Mean indoor/outdoor ratios (I/O) of UFP at three preschools were lower than 1 (0.54–0.93), indicating that outdoor emissions significantly contributed to UFP indoors. Significant correlations were obtained between temperature, wind speed, relative humidity, solar radiation, and ambient UFP number concentrations. The estimated exposure doses were higher in children attending urban preschools; 3–5-year-old children were exposed to 4–6 times higher UFP doses than adults with similar daily schedules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The English article system is actually so complex that it presents many challenges for most non-native learners of English. The main difficulty of Portuguese learners, despite the numerous similarities between the two article systems, is noticeable in a marked tendency to produce the definite article where native speakers of English would not use it. This article reports the results of a cross-sectional study which examined the English definite article overproduction by a group of 12 Portuguese EFL learners with at least seven years of English instruction. The prediction is that these learners will exhibit evidence of transferring L1 features to their interlanguage when they overuse the definite article. The data were collected by means of a gap-filling task and a composition. The results found, as predicted, that these learners overused the in generic contexts. It is argued that this overuse is directly tied to and can be explained by transfer to somewhere and conceptual transfer principles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Artigo científico disponível actualmente em Early View (Online Version of Record published before inclusion in an issue)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Contabilidade e Finanças, sob orientação de Doutora Deolinda Meira e Doutora Nina Aguiar

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação apresentada para obtenção do Grau de Mestre em Contabilidade e Finanças, sob orientação de: Amélia Ferreira da Silva José António Fernandes Lopes Oliveira Vale

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatório de Estágio Apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Empreendedorismo e Internacionalização, sob orientação da Mestre Inês Veiga Pereira

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development in power systems and the introduction of decentralized generation and Electric Vehicles (EVs), both connected to distribution networks, represents a major challenge in the planning and operation issues. This new paradigm requires a new energy resources management approach which considers not only the generation, but also the management of loads through demand response programs, energy storage units, EVs and other players in a liberalized electricity markets environment. This paper proposes a methodology to be used by Virtual Power Players (VPPs), concerning the energy resource scheduling in smart grids, considering day-ahead, hour-ahead and real-time scheduling. The case study considers a 33-bus distribution network with high penetration of distributed energy resources. The wind generation profile is based on a real Portuguese wind farm. Four scenarios are presented taking into account 0, 1, 2 and 5 periods (hours or minutes) ahead of the scheduling period in the hour-ahead and realtime scheduling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The study seeks to identify the determinant factors of the repatriate’s decision to remain or leave the company after repatriation, in a convenience sample of 40 Portuguese returnees working in companies based in Portugal. The main results were as follows: (1) there are seven factor categories: (a) salaries and benefits; (b) possibility of promotion, development, professional development; (c) organizational support (during and after the international mission) recognition of work; (d) economic and social atmosphere of the company, (e) good relationship with leadership; (f) convenience and/or personal / family well-being and; (g) external alternatives; (2) the main factors leading to permanence are (a) possibility of promotion, development and professional development and; (b) the existence of personal and family well-being / convenience; (3) the main factors leading to abandonment are (a) lack of organizational support and recognition of work performed; (b) lack of possibility of promotion, development and professional development and; (c) lack of personal / family well-being / convenience. Globally, the study suggests that the factors leading to permanence are very similar to those that lead to abandonment, although in reverse.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de Mestrado Apresentada ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação do Mestre Carlos Mendes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A manutenção, durante vários anos, traduziu-se num conceito paliativo de instalações e equipamentos, o que se veio a revelar como uma atitude negligente perante o Homem e o Ambiente. As preocupações ambientais estão na ordem do dia e têm sido muitas as vozes que se têm levantado para que o consumo de energia seja mais equilibrado e para que as emissões de CO2 diminuam de forma a preservar o Planeta. De acordo com a resolução do Conselho Europeu, em 2007 (1), foi apresentado um pacote de propostas que visam a sustentabilidade e estimulam a Eficiência Energética (EE), com o objectivo de reduzir os consumos energéticos dos edifícios, quer estes sejam novos ou reabilitados. Segundo a Direcção Geral de Energia e Geologia os edifícios são responsáveis por 60% dos consumos de energia eléctrica, consumo esse que pode ser reduzido em mais de 50%, através de medidas de EE, traduzindo-se numa redução de 400 milhões de toneladas de CO2 por ano. (2) Para além de medidas de EE, também as práticas de manutenção preventiva podem contribuir para a diminuição dos consumos energéticos e de emissões de CO2. Segundo o Institute for Building Efficiency práticas de manutenção preventiva em equipamentos de Aquecimento Ventilação e Ar Condicionado (AVAC) reduzem os consumos energéticos de 10 a 20% e, em contrapartida, a negligência na execução da manutenção pode aumentar os consumos energéticos de 30 a 60%. (3) Uma outra análise de valores a ter em conta, é a Intensidade Energética (IE). Leia-se IE como sendo o valor global da energia consumida num país a dividir pelo seu produto interno bruto. A contribuição do sector dos serviços para a IE nacional era de 17% no ano de 2005. (4) Se a estes dados acrescentarmos que 70% dessa energia é consumida por equipamentos AVAC (5) e que práticas de manutenção reduzem esses valores entre 10 a 20%, pode concluir-se que a redução de custos energéticos associada à manutenção preventiva é efectiva e significativa. Apresentando um cenário ideal e hipotético, se ao contributo do sector dos serviços, para a IE nacional, se isolar o valor referente a equipamentos de AVAC, obtem-se uma IE de aproximadamente 12%. Se adicionalmente se considerar uma taxa de redução, relativa à execução da manutenção, entre 10 e 20%, Portugal obteria uma IE, relativamente aos consumos energéticos em edificios de serviços, não de 17% mas sim entre 14,6% e 15,8%. Neste trabalho pretende-se comprovar que um plano de actividades de manutenção equilibrado, monitorizado, e gerido de forma eficaz e funcional, é uma ferramenta fundamental no cumprimento de objectivos e metas europeias traçadas, que se reúnem num objectivo comum de preservação do planeta. A adopção deste tipo de medidas contribuirá para a racionalização dos consumos energéticos e para o aumento da vida útil dos equipamentos, bem como para a melhoria do desempenho económico e financeiro das organizações, tal como se poderá ler mais à frente neste trabalho. Será também analisado um caso prático, verificando a eficácia das medidas tomadas durante as intervenções preventivas de manutenção, sendo que para isso será estudado o comportamento de um equipamento, antes e após a realização de tarefas de manutenção preventiva. Tentar-se-á, junto de gestores de edifícios, recolher a opinião que têm sobre a importância da manutenção. Ao longo de toda a pesquisa foi possível consolidar a hipótese formulada inicialmente no que concerne ao contributo da manutenção para a sustentabilidade, quer através da revisão da literatura, quer nos testes efectuados a equipamentos. Foi possível confirmar que um plano de manutenção ajustado, monitorizado e cumprido é uma ferramenta na diminuição dos consumos energéticos, aumento da vida útil de equipamentos e por sua vez na diminuição de emissões de CO2. Verificou-se também que o controlo de poluentes e ventilação adequada dos edifícios são uma ferramenta essencial para a qualidade do ar interior, parâmetros facilmente controlados nas actividades de manutenção. O contributo das opiniões recolhidas entre os gestores de edifícios, para este estudo, foi também bastante importante, uma vez que todos eles reconhecem o papel importante da manutenção, mas nem todos estão sensibilizados para o seu papel na sustentabilidade do planeta. Nesta dissertação é deixado um alerta: o crescimento da população mundial e a consequente utilização de recursos naturais que são finitos, não sendo controlado de uma forma sustentada, pode resultar na destruição de um planeta único. O papel negativo do Homem nas alterações climáticas é inequívoco e é necessário melhorar a sua relação com o Ambiente. Cada ser humano está inserido na sua comunidade e dentro dela tem a sua função, cabe a cada um exercer esta responsabilidade nas suas actividades do dia-a-dia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Master Thesis Presented at Instituto de Contabilidade e Administração do Porto for obtaining the Master’s degree in Digital Marketing under the supervision of Professor José de Freitas Santos