62 resultados para REAGENT

em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo (BDPI/USP)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduction of the natural sesquiterpene lactones furanoheliangolides with Stryker's reagent is an effective process for producing eremantholides through a biomimetic pathway. Other reduction products are also formed. Oxygenated functions at C-15 of the furanoheliangolide produce an increase in the velocities of the reactions and reduce the chemoselectivity of the reagent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system designed with solenoid micro-pumps is introduced for spectrophotometric determination of total tannins based on the Folin- Denis reaction. The procedure minimizes the main drawbacks related to the AOAC batch procedure, i.e. interferences from reducing species in the samples, high reagent consumption and waste generation, and low sampling rate. Linear response was observed for tannic acid concentrations in the range 2-100 mg L-1, with a detection limit (99.7% confidence level) of 0.3 mg L-1. The sampling rate and coefficient of variation (n = 10) were estimated as 75 measurements per hour and 1.1%, respectively. Results of determination of total tannin in tea, beer and wine samples were in agreement with those achieved by the batch reference procedure at the 95% confidence level. In comparison to the batch procedure, the reagent consumption and effluent generation were 83 and 60-fold lower, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conversion of a furanoheliangolide structure (15-deoxygoyazensolide) into an eremantholide one (eremantholide C) was achieved by tandem hydride conjugate addition-intramolecular carbanion addition using Stryker`s reagent. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recovery and stability of DNA for the detection and genotyping of HPV in UCM-containing specimens, after exposure to denaturing reagents and stored for up to 2 years were evaluated. Samples were collected from 60 women who had cervical cytology specimens harboring cervical intraepithelial neoplasia (CIN) 2 or 3. All samples were stored in UCM and had been frozen at -20 degrees C following the addition of the denaturing reagent (sodium hydroxide) and the removal of the aliquot required for Hybrid Capture 2 testing for the identification of HPV DNA. The samples had been stored for 6, 12 and 24 months (20 samples for each storage time). HPV DNA extraction was performed according to a protocol designed specifically and the presence and quality of DNA was confirmed by human P-globin detection using the consensus primers G73 and G74. HPV DNA was amplified using the consensus primers PGMY09 and PGMY11, and reverse line-blot hybridization was used to detect type-specific amplicons for 37 HPV types. The DNA extracted from the denatured specimen was recovered in 57/60 (95%) of the samples. HPV DNA was detected in 56/57 (98%) of the recovered samples. Twenty-six of the 56 samples recovered (48%) were genotyped successfully. (c) 2007 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The first one-pot synthesis of neutral and electron-rich [hydroxy(tosyloxy)iodo]arenes (HTIBs) from iodine and arenes is presented, thereby avoiding the need for expensive iodine(III) precursors. A large set of including a polyfluorinated analogue, can be obtained from the corresponding aryl iodide under the same conditions. The reaction proceeds under mild conditions, without excess reagents, and is fast and high-yielding. Together, the two presented routes give access to a wide range of HTIBs, which are useful reagents in a variety of synthetic transformations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for the preparation of alpha,beta-unsaturated diazoketones from aldehydes and a Horner-Wadsworth- Emmons reagent is reported. The method was applied to the short synthesis of two substituted pyrrolidines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of modern analytical tools plays an important role in quality control. The main purpose of this study was to explore the use of subcritical water as a versatile analytical tool, employed simultaneously as a reagent and solvent, as well as the application of high temperature-high resolution gas chromatography (HT-HRGC) to develop a procedure for the analysis of triacylglycerides and fatty acids in Azadirachta indica A. Juss. (Neem) oil without the need for solvents, chemical reagents, or catalytic agents. The developed method presented satisfactory results and is in agreement with the concepts of Green Analytical Chemistry (GAC).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on the development of a simple and fast procedure for β-carotene extraction from carrots and its quantification by UV/Vis spectroscopy. Carotenoids extracted from carrots may also be used as alternative reagents for TLC (thin layer chromatography) detection of natural compounds with antioxidant properties, replacing the commercial p.a. grade β-carotene. Although this reagent had around 10% b-carotene, it proved to be as efficient for TLC analysis as the commercial p.a. grade β-carotene. This practice is a useful alternative for teaching undergraduate organic chemistry laboratory classes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The antioxidant activity of sugarcane (Saccharum officinarum L.) juice towards DPPH reagent was determined (EC50) and the main compounds with radical scavenging activity in juice and leaves extracts were identified by HPLC-UV/PAD analysis combined with HPLC microfractionation monitored by TLC using β-carotene and DPPH as the detection reagents. In sugarcane leaves, luteolin-8-C-(rhamnosylglucoside) (1) was the most important compound with radical scavenging activity; in sugarcane juice, the flavones diosmetin-8-C-glucoside (2), vitexin (3) schaftoside (9), isoschaftoside (10) and 4',5'-dimethyl-luteolin-8-C-glucoside (11) were the most relevant compounds. The content of juice flavonoids (0.241 ± 0.001 mg total flavonoids/mL juice), comparable to other food sources of flavonoids, suggest the potential of sugarcane as a dietary source of natural antioxidants. However, the low antioxidant ability of sugarcane juice (EC50 = 100.2 ± 2.6 g L-1) also points to the need for further studies about the dietary intake of sugarcane flavonoids and its effects on human health.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The sensitivity and accuracy of sequential injection methods are dependent on efficient overlapping of reagent and sample zones as they are propelled toward the detector cell. The formation of the reduced phosphomolybdic acid is used to demonstrate that the overlapping efficiency in a fixed reaction coil relies on a suitable choice of reagent to sample volume ratio. Additionally, under poor mixing conditions or highly concentrated samples, the reaction extension is strongly dependent on the reagent concentration. The zone-sampling concept is exploited to determine phosphate in cola-based soft drinks after in-line dilution in an auxiliary coil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The electrochemical behavior of fluconazole showed an irreversible oxidation process, with the electrochemical - chemical mechanism being highly dependent on the electrode material. Adsorption of reagent at positive applied potential was observed at Pt electrode while preferential adsorption of the oxidation products was observed at Glassy Carbon surfaces. In pH below 7.0, the anodic current process was intensively decreased. At carbon paste electrode, the fluconazole oxidation current, recorded in phosphate buffer solution (pH 8.0), changed linearly with the fluconazole concentration, Ipa = 5.7×10-5 (mA) × 0.052 [Fluconazol] (μg mL-1), in the range of 48.0 to 250.0 μg mL-1. The detection limit obtained was 6.3 μg mL-1.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A metal-free protocol was developed to synthesize indanes by ring contraction of 1, 2-dihydronaphthalenes promoted by PhI(OH)OTs (HTIB or Koser's reagent). This oxidative rearrangement can be performed in several solvents (MeOH, CH3CN, 2 , 2, 2-trifluoroethanol (TFE), 1 , 1, 1, 3, 3, 3-hexafluoroisopropanol (HFIP), and a 1:4 mixture of TFE:CH2Cl2) under mild conditions. The ring contraction diastereoselectively gives functionalized trans-1, 3-disubstituted indanes, which are difficult to obtain in synthetic organic chemistry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Um método espectrofotométrico simples foi desenvolvido para a determinação do bromidrato de fenoterol (BF) em comprimidos, gotas e xarope, como princípio ativo único e associado ao ibuprofeno. O método se baseia na reação de acoplamento oxidativo do BF com o 3-metil-2-benzotiazolinona hidrazona (MBTH), na presença de sulfato cérico, como agente oxidante. A mistura de BF, MBTH e sulfato cérico, em meio ácido, produz um composto colorido (vermelho castanho) com máximo de absorção a 475 nm. A curva de calibração foi linear num intervalo de concentração de 3,0 a 12,0 µg/mL, com coeficiente de correlação linear de 0,9998. Os parâmetros experimentais que afetam o desenvolvimento e a estabilidade do produto colorido foram cuidadosamente estudados e otimizados. O método foi aplicado em amostras comerciais e simuladas, obtendo-se coeficientes de variação entre 0,25 % a 0,82 % e médias de recuperação do padrão que variaram de 98 % a 102 %. O método proposto mostrou-se exato, preciso, linear e não é passível de interferência de excipientes, para as formas farmacêuticas comprimidos e gotas. Não houve interferência do ibuprofeno que consta de uma das formulações analisadas, associado ao BF. Quanto ao xarope, houve interferência do veículo sugerindo reações de seus componentes com o MBTH.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A photometric procedure for the determination of ClO(-) in tap water employing a miniaturized multicommuted flow analysis setup and an LED-based photometer is described. The analytical procedure was implemented using leucocrystal violet (LCV; 4,4', 4 ''-methylidynetris (N, N-dimethylaniline), C(25)H(31)N(3)) as a chromogenic reagent. Solenoid micropumps employed for solutions propelling were assembled together with the photometer in order to compose a compact unit of small dimensions. After control variables optimization, the system was applied for the determination of ClO(-) in samples of tap water, and aiming accuracy assessment samples were also analyzed using an independent method. Applying the paired t-test between results obtained using both methods, no significant difference at the 95% confidence level was observed. Other useful features include low reagent consumption, 2.4 mu g of LCV per determination, a linear response ranging from 0.02 up to 2.0 mg L(-1) ClO(-), a relative standard deviation of 1.0% (n = 11) for samples containing 0.2 mg L(-1) ClO(-), a detection limit of 6.0 mu g L(-1) ClO(-), a sampling throughput of 84 determinations per hour, and a waste generation of 432 mu L per determination.