27 resultados para Intraocular aberration
em Universidad de Alicante
Resumo:
Purpose: To examine a single-optic accommodating intraocular lens (IOL) visual performance by correlating IOL implanted eyes’ defocus curve with the intraocular aberrometric profile and the impact on the quality of life (QOL). Methods: Prospective consecutive case series study including a total of 25 eyes of 14 patients with ages ranging between 52 and 79 years old. All cases underwent cataract surgery with implantation of the single-optic accommodating IOL Crystalens HD (Bausch & Lomb). Distance and near visual acuity outcomes, intraocular aberrations, the defocus curve and QOL (NEI VFQ-25) were evaluated 3 months after surgery. Results: A significant improvement in distance visual acuity was found postoperatively (p = 0.02). Mean postoperative LogMAR uncorrected near visual acuity was 0.44 ± 0.23 (20/30). 60% of eyes had a postoperative addition between 0 and 1.5 diopters (D). The defocus curve showed an area of maximum visual acuity for the levels of defocus corresponding to distance and intermediate vision (−1 to +0.5 D). Postoperative intermediate visual acuity correlated significantly some QOL indices (r ≥ 0.51, p ≤ 0.03; difficulty in going down steps or seeing how people react to things that patient says) as well as with J0 component of manifest cylinder. Postoperative distance-corrected near visual acuity correlated significantly with age (r = 0.65, p < 0.01). Conclusions: This accommodating IOL seems to be able to restore the distance visual function as well as to provide an improvement in intermediate and near vision with a significant impact on patient's QOL, although limited by age and astigmatism. Future studies with larger sample sizes should confirm all these trends.
Resumo:
Purpose To evaluate visual, optical, and quality of life (QoL) outcomes and intercorrelations after bilateral implantation of posterior chamber phakic intraocular lenses. Methods Twenty eyes with high to moderate myopia of 10 patients that underwent PRL implantation (Phakic Refractive Lens, Carl Zeiss Meditec AG) were examined. Refraction, visual acuity, photopic and low mesopic contrast sensitivity (CS) with and without glare, ocular aberrations, as well as QoL outcomes (National Eye Institute Refractive Error Quality of Life Instrument-42, NEI RQL-42) were evaluated at 12 months postoperatively. Results Significant improvement in uncorrected (UDVA) and best-corrected distance (CDVA) visual acuities were found postoperatively (p < 0.01), with significant reduction in spherical equivalent (p < 0.01). Low mesopic CS without glare was significantly better than measurements with glare for 1.5, 3, and 6 cycles/degree (p < 0.01). No significant correlations between higher order root mean square (RMS) with CDVA (r = −0.26, p = 0.27) and CS (r ≤ 0.45, p ≥ 0.05) were found. Postoperative binocular photopic CS for 12 cycles/degree and 18 cycles/degree correlated significantly with several RQL-42 scales. Glare index correlated significantly with CS measures and scotopic pupil size (r = −0.551, p = 0.04), but not with higher order RMS (r = −0.02, p = 0.94). Postoperative higher order RMS, postoperative primary coma and postoperative spherical aberration was significant higher for 5-mm pupil diameter (p < 0.01) compared with controls. Conclusions Correction of moderate to high myopia by means of PRL implantation had a positive impact on CS and QoL. The aberrometric increase induced by the surgery does not seem to limit CS and QoL. However, perception of glare is still a relevant disturbance in some cases possibly related to the limitation of the optical zone of the PRL.
Resumo:
Background To evaluate the intraocular lens (IOL) position by analyzing the postoperative axis of internal astigmatism as well as the higher-order aberration (HOA) profile after cataract surgery following the implantation of a diffractive multifocal toric IOL. Methods Prospective study including 51 eyes with corneal astigmatism of 1.25D or higher of 29 patients with ages ranging between 20 and 61 years old. All cases underwent uneventful cataract surgery with implantation of the AT LISA 909 M toric IOL (Zeiss). Visual, refractive and corneal topograpy changes were evaluated during a 12-month follow-up. In addition, the axis of internal astigmatism as well as ocular, corneal, and internal HOA (5-mm pupil) were evaluated postoperatively by means of an integrated aberrometer (OPD Scan II, Nidek). Results A significant improvement in uncorrected distance and near visual acuities (p < 0.01) was found, which was consistent with a significant correction of manifest astigmatism (p < 0.01). No significant changes were observed in corneal astigmatism (p = 0.32). With regard to IOL alignment, the difference between the axes of postoperative internal and preoperative corneal astigmatisms was close to perpendicularity (12 months, 87.16° ± 7.14), without significant changes during the first 6 months (p ≥ 0.46). Small but significant changes were detected afterwards (p = 0.01). Additionally, this angular difference correlated with the postoperative magnitude of manifest cylinder (r = 0.31, p = 0.03). Minimal contribution of intraocular optics to the global magnitude of HOA was observed. Conclusions The diffractive multifocal toric IOL evaluated is able to provide a predictable astigmatic correction with apparent excellent levels of optical quality during the first year after implantation.
Resumo:
Purpose: To evaluate the visual, refractive, contrast-sensitivity, and aberrometric outcomes during a 1-year follow-up after implantation of a trifocal intraocular lens (IOL). Setting: Premium Clinic, Teplice, Czech Republic. Design: Prospective case series. Methods: This study included eyes of patients having cataract surgery with implantation of the trifocal IOL model AT Lisa tri 839MP. Distance, intermediate (66 and 80 cm), and near (33 and 40 cm) vision; contrast sensitivity; aberrometric outcomes; and the defocus curve were evaluated during a 12-month follow-up. The level of posterior capsule opacification (PCO) was also evaluated. Results: In 120 eyes (60 patients), 1 month postoperatively, an improvement was observed in all visual parameters (P ≤ .03) except corrected near and intermediate visual acuities (both P ≥ .05). From 1 month to 12 months postoperatively, small but statistically significant changes were observed in uncorrected and corrected distance and near visual acuities (all P ≤ .03) and in uncorrected intermediate visual acuity (P = .01). In the defocus curve, no significant differences were found between visual acuities corresponding to defocus levels of −1.0 diopter (D) and −2.0 D (P = .22). The level of ocular spherical aberration decreased statistically significantly at 6 months (P < .001). Ocular and internal higher-order aberrations increased minimally but significantly from 6 to 12 months postoperatively (P < .001). The mean 12-month PCO score was 0.32 ± 0.44 (SD). Four eyes (3.3%) required neodymium:YAG capsulotomy. Conclusion: The trifocal IOL provided complete and stable visual restoration after cataract surgery during a 12-month follow-up, with good levels of visual quality.
Resumo:
We describe a case report of a patient that was implanted with a posterior chamber phakic intraocular lens (Phakic Refractive Lens, PRL) for the correction of moderate myopia and who developed postoperatively a fixed mydriasis compatible with an Urrets-Zavalia Syndrome (UZS). Specifically, a sudden acute increase of IOP in the left eye was observed in the immediate postoperative period. After IOP stabilization, the refractive result was good, but a fixed and mydriatic pupil appeared. This condition led the patient to experience visual discomfort, halos, and glare associated with high levels of higher-order aberrations in spite of the good visual result. A tinted-contact lens was fitted in order to minimize those symptoms. The UZS should be considered as a possible complication after implantation of posterior chamber phakic intraocular lenses.
Resumo:
Presbyopia is an age-related physiological condition that causes a gradual loss in the ability to focus on near objects, secondary to changes in zonular fibers, ciliary muscle and crystalline lens. Different surgical approaches are being pursued to surgically compensate presbyopia, such as corneal techniques or implantation of multifocal intraocular lenses (IOLs); however, their inability to restore accommodation has led to the development of single-optic positional accommodative IOLs. The axial shift, with the contraction of the ciliary muscle, of these IOLs increases the refractive power of the eye, improving the level of uncorrected near vision. Single-optic positional accommodative IOLs present few disturbances and larger ocular aberrations that improve near vision. However, reduced amplitudes of accommodation are obtained, little IOL shifts are measured and overall visual outcomes are limited.
Resumo:
AIM: To evaluate the prediction error in intraocular lens (IOL) power calculation for a rotationally asymmetric refractive multifocal IOL and the impact on this error of the optimization of the keratometric estimation of the corneal power and the prediction of the effective lens position (ELP). METHODS: Retrospective study including a total of 25 eyes of 13 patients (age, 50 to 83y) with previous cataract surgery with implantation of the Lentis Mplus LS-312 IOL (Oculentis GmbH, Germany). In all cases, an adjusted IOL power (PIOLadj) was calculated based on Gaussian optics using a variable keratometric index value (nkadj) for the estimation of the corneal power (Pkadj) and on a new value for ELP (ELPadj) obtained by multiple regression analysis. This PIOLadj was compared with the IOL power implanted (PIOLReal) and the value proposed by three conventional formulas (Haigis, Hoffer Q and Holladay). RESULTS: PIOLReal was not significantly different than PIOLadj and Holladay IOL power (P>0.05). In the Bland and Altman analysis, PIOLadj showed lower mean difference (-0.07 D) and limits of agreement (of 1.47 and -1.61 D) when compared to PIOLReal than the IOL power value obtained with the Holladay formula. Furthermore, ELPadj was significantly lower than ELP calculated with other conventional formulas (P<0.01) and was found to be dependent on axial length, anterior chamber depth and Pkadj. CONCLUSION: Refractive outcomes after cataract surgery with implantation of the multifocal IOL Lentis Mplus LS-312 can be optimized by minimizing the keratometric error and by estimating ELP using a mathematical expression dependent on anatomical factors.
Resumo:
Diurnal changes in corneal geometry, pachymetry, and intraocular pressure (IOP) in a healthy eye were recorded. The deformation response to an air puff was simulated using 3 levels of corneal stiffness. The response was dependent on IOP and pachymetry and not only on the biomechanical properties of the cornea. Similarly, the maximum variability due to the diurnal changes in pachymetry and IOP in the corneal displacement generated by the air puff was found to reach 5%. Therefore, diurnal changes in IOP and corneal thickness were able to induce some variability in the air puff–based corneal deformation response. This potential variability should be considered when the biomechanical properties of the cornea are analyzed with air-puff devices.
Resumo:
Purpose: To evaluate the predictability of the refractive correction achieved with a positional accommodating intraocular lenses (IOL) and to develop a potential optimization of it by minimizing the error associated with the keratometric estimation of the corneal power and by developing a predictive formula for the effective lens position (ELP). Materials and Methods: Clinical data from 25 eyes of 14 patients (age range, 52–77 years) and undergoing cataract surgery with implantation of the accommodating IOL Crystalens HD (Bausch and Lomb) were retrospectively reviewed. In all cases, the calculation of an adjusted IOL power (PIOLadj) based on Gaussian optics considering the residual refractive error was done using a variable keratometric index value (nkadj) for corneal power estimation with and without using an estimation algorithm for ELP obtained by multiple regression analysis (ELPadj). PIOLadj was compared to the real IOL power implanted (PIOLReal, calculated with the SRK-T formula) and also to the values estimated by the Haigis, HofferQ, and Holladay I formulas. Results: No statistically significant differences were found between PIOLReal and PIOLadj when ELPadj was used (P = 0.10), with a range of agreement between calculations of 1.23 D. In contrast, PIOLReal was significantly higher when compared to PIOLadj without using ELPadj and also compared to the values estimated by the other formulas. Conclusions: Predictable refractive outcomes can be obtained with the accommodating IOL Crystalens HD using a variable keratometric index for corneal power estimation and by estimating ELP with an algorithm dependent on anatomical factors and age.
Resumo:
Índice, resumen, conclusiones y bibliografía de la memoria del Máster en Optometría Clínica y Visión, Programa formativo en Biomedicina y Tecnologías para la vida.
Resumo:
Retinal image quality is commonly analyzed through parameters inherited from instrumental optics. These parameters are defined for ‘good optics’ so they are hard to translate into visual quality metrics. Instead of using point or artificial functions, we propose a quality index that takes into account properties of natural images. These images usually show strong local correlations that help to interpret the image. Our aim is to derive an objective index that quantifies the quality of vision by taking into account the local structure of the scene, instead of focusing on a particular aberration. As we show, this index highly correlates with visual acuity and allows inter-comparison of natural images around the retina. The usefulness of the index is proven through the analysis of real eyes before and after undergoing corneal surgery, which usually are hard to analyze with standard metrics.
Resumo:
We report on a procedure to improve the resolution of far-field imaging by using a neighboring high-index medium that is coated with a left-handed metamaterial. The resulting plot can also exhibit an enhanced transmission by considering proper conditions to retract backscattering. Based on negative refraction, geometrical aberrations are considered in detail since they may cause a great impact in this sort of diffraction-unlimited imaging by reducing its resolution power. We employ a standard aberration analysis to refine the asymmetric configuration of metamaterial superlenses. We demonstrate that low-order centrosymmetric aberrations can be fully corrected for a given object plane. For subwavelength-resolution imaging, however, high-order aberrations become of relevance, which may be balanced with defocus. Not only the point spread function but also numerical simulations based on the finite-element method support our theoretical analysis, and subwavelength resolution is verified in the image plane.
Resumo:
We show that subwavelength diffracted wave fields may be managed inside multilayered plasmonic devices to achieve ultra-resolving lensing. For that purpose we first transform both homogeneous waves and a broad band of evanescent waves into propagating Bloch modes by means of a metal/dielectric (MD) superlattice. Beam spreading is subsequently compensated by means of negative refraction in a plasmon-induced anisotropic effective-medium that is cemented behind. A precise design of the superlens doublet may lead to nearly aberration-free images with subwavelength resolution in spite of using optical paths longer than a wavelength.
Resumo:
Objective: To evaluate the visual and refractive outcomes after phacoemulsification surgery in eyes with isolated lens coloboma. Design: Prospective, consecutive case series. Participants: Eighteen eyes with isolated lens coloboma of 13 patients were included in the study. Mean patient age was 13.9 ± 6.5 years. Methods: Patients underwent phacoemulsification surgery, with combined implantation of capsular tension ring (CTR) and intraocular lens. In colobomas of less than 120°, a CTR was used, whereas in colobomas of more than 120°, a Cionni-modified single eyelet CTR was used to achieve better capsular centration. The main outcome measures were uncorrected distance visual acuity, corrected distance visual acuity, refraction, and keratometry. Results: Mean logMAR uncorrected distance visual acuity and corrected distance visual acuity improved significantly from 1.53 ± 0.35 and 1.02 ± 0.47 before surgery to 0.67 ± 0.51 and 0.52 ± 0.49 at the last visit of the follow-up (p < 0.001). Mean refractive cylinder and spherical equivalent decreased significantly from –6.73 ± 1.73 and –6.72 ± 4.07 D preoperatively to –1.40 ± 1.39 and –0.83 ± 1.31 D at the end of the follow-up (p = 0.001 and p = 0.01, respectively). Mean keratometric astigmatism at preoperative and postoperative visits were 1.58 ± 0.97 and 1.65 ± 0.94 D, respectively (p = 0.70). Conclusions: Phacoemulsification with CTR and intraocular lens implantation is an effective and safe option for providing a refractive correction and a significant visual improvement in eyes with isolated lens coloboma.