25 resultados para Reliability and Validity
em Biblioteca Digital da Produção Intelectual da Universidade de São Paulo
Resumo:
The use of patient-orientated questionnaires is of utmost importance in assessing the outcome of spine surgery. Standardisation, using a common set of outcome measures, is essential to aid comparisons across studies/in registries. The Core Outcome Measures Index (COMI) is a short, multidimensional outcome instrument validated for patients with spinal disorders. This study aimed to produce a Brazilian-Portuguese version of the COMI. A cross-cultural adaptation of the COMI into Brazilian-Portuguese was carried out using established guidelines. 104 outpatients with chronic LBP (> 3 months) were recruited from a Public Health Spine Medical Care Centre. They completed a questionnaire booklet containing the newly translated COMI, and other validated symptom-specific questionnaires: Oswestry Disability Index (ODI) and Roland Morris disability scale (RM), and a pain visual analogue scale. All patients completed a second questionnaire within 7-10 days to assess reproducibility. The COMI summary score displayed minimal floor and ceiling effects. On re-test, the responses for each individual domain of the COMI were within 1 category in 98% patients for the domain 'function', 96% for 'symptom-specific well-being', 97% for 'general quality of life', 99% for 'social disability' and 100% for 'work disability'. The intraclass correlation coefficients (ICC2,1) for COMI pain and COMI summary scores were 0.91-0.96, which compared favourably with the corresponding values for the RM (ICC, 0.99) and ODI (ICC, 0.98). The standard error of measurement for the COMI was 0.6, giving a "minimum detectable change" (MDC95%) of approximately 1.7 points i.e., the minimum change to be considered "real change" beyond measurement error. The COMI scores correlated as hypothesised (Rho, 0.4-0.8) with the other symptom-specific questionnaires. The reproducibility of the Brazilian-Portuguese version of the COMI was comparable to that of other language versions. The COMI scores correlated in the expected manner with existing but longer symptom-specific questionnaires suggesting good convergent validity for the COMI. The Brazilian-Portuguese COMI represents a valuable tool for Brazilian study-centres in future multicentre clinical studies and surgical registries.
Reliability and validity of spirituality questionnaire by Parsian and Dunning in the Spanish version
Resumo:
The aim of this methodological study was to translate, culturally adapt and assess the internal consistency and validity of the Spanish version of the "Spirituality Questionnaire". The sample comprised 204 young people between 18 and 25 years of age from two universities in Bogota. Cronbach's Alpha was used for reliability, while groups of experts and young people were used for construct validity. The reliability score of the total instrument was 0.88. The overall index of content validity corresponded to 0.90. Exploratory factor analysis showed that four factors explain 52.60% of the variance. The originally proposed theoretical model was confirmed and, in two dimensions, a different structure was proposed. In conclusion, the instrument "Spirituality Questionnaire" by Parsian and Dunning is reliable and valid in the Spanish version.
Resumo:
Chaabene, H, Hachana, Y, Franchini, E, Mkaouer, B, Montassar, M, and Chamari, K. Reliability and construct validity of the karate-specific aerobic test. J Strength Cond Res 26(12): 3454-3460, 2012-The aim of this study was to examine absolute and relative reliabilities and external responsiveness of the Karate-specific aerobic test (KSAT). This study comprised 43 male karatekas, 19 of them participated in the first study to establish test-retest reliability and 40, selected on the bases of their karate experience and level of practice, participated in the second study to identify external responsiveness of the KSAT. The latter group was divided into 2 categories: national-level group (G(n)) and regional-level group (Gr). Analysis showed excellent test-retest reliability of time to exhaustion (TE), with intraclass correlation coefficient ICC(3,1) >0.90, standard error of measurement (SEM) <5%: (3.2%) and mean difference (bias) +/- the 95% limits of agreement: -9.5 +/- 78.8 seconds. There was a significant difference between test-retest session in peak lactate concentration (Peak [La]) (9.12 +/- 2.59 vs. 8.05 +/- 2.67 mmol.L-1; p < 0.05) but not in peak heart rate (HRpeak) and rating of perceived exertion (RPE) (196 +/- 9 vs. 194 +/- 9 b.min(-1) and 7.6 +/- 0.93 vs. 7.8 +/- 1.15; p > 0.05), respectively. National-level karate athletes (1,032 +/- 101 seconds) were better than regional level (841 +/- 134 seconds) on TE performance during KSAT (p < 0.001). Thus, KSAT provided good external responsiveness. The area under the receiver operator characteristics curve was >0.70 (0.86; confidence interval 95%: 0.72-0.95). Significant difference was detected in Peak [La] between national- (6.09 +/- 1.78 mmol.L-1) and regional-level (8.48 +/- 2.63 mmol.L-1) groups, but not in HRpeak (194 +/- 8 vs. 195 +/- 8 b.min(-1)) and RPE (7.57 +/- 1.15 vs. 7.42 +/- 1.1), respectively. The result of this study indicates that KSAT provides excellent absolute and relative reliabilities. The KSAT can effectively distinguish karate athletes of different competitive levels. Thus, the KSAT may be suitable for field assessment of aerobic fitness of karate practitioners.
Resumo:
Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.
Resumo:
The objective of this study was to perform the translation on and cultural adaptation of the Global Appraisal of Individual Needs - Initial instrument, and calculate its content validity index. This is a methodological study designed for the cultural adaptation of the instrument. The instrument was translated into Portuguese in two versions that originated the synthesis of the translations, which were then submitted to the evaluation of four judges, experts in the field of alcohol and other drugs. After the suggested changes were made, the instrument was back-translated and resubmitted to the judges and authors of the original instrument, resulting in the final version of the instrument, Avaliacao Global das Necessidades Individuais - Inicial. The content validity index of the instrument was 0.91, considered valid according to the literature. The instrument Avaliacao Global das Necessidades Individuais - Inicial was culturally adapted to the Portuguese language spoken in Brazil; however, it was not submitted to tests with the target population, which suggests further studies should be performed to test its reliability and validity.
Resumo:
Objectives: The aim of the present study was to investigate the construct validity of the Assessment of Countertransference Scale (ACS) in the context of the trauma care, through the identification of the underlying latent constructs of the measured items and their homogeneity. Methods: ACS assesses 23 feelings of CT in three factors: closeness, rejection and indifference. ACS was applied to 50 residents in psychiatry after the first appointment with 131 victims of trauma consecutively selected during 4 years. ACS was analyzed by exploratory (EFA) and confirmatory (CFA) factor analysis, internal consistence and convergent-discriminant validity. Results: In spite of the fact that closeness items obtained the highest scores, the EFA showed that the factor rejection (24% of variance, alpha = 0.88) presented a more consistent intercorrelation of the items, followed by closeness (15% of variance, alpha = 0.82) and, a distinct factor, sadness (9% of variance, alpha = 0.72). Thus, a modified version was proposed. In the comparison between the original and the proposed version, CFA detected better goodness-of-fit indexes for the proposed version (GFI = 0.797, TLI = 0.867, CFI = 0.885 vs. GFI = 0.824, TLI = 0.904, CFI = 0.918). Conclusions: ACS is a promising instrument for assessing CT feelings, making it valid to access during the care of trauma victims.
Resumo:
Objective To evaluate and compare the intraobserver and interobserver reliability and agreement for the biparietal diameter (BPD), abdominal circumference (AC), femur length (FL) and estimated fetal weight (EFW) obtained by two-dimensional ultrasound (2D-US) and three-dimensional ultrasound (3D-US). Methods Singleton pregnant women between 24 and 40 weeks were invited to participate in this study. They were examined using 2D-US in a blinded manner, twice by one observer, intercalated by a scan by a second observer, to determine BPD, AC and FL. In each of the three examinations, three 3D-US datasets (head, abdomen and thigh) were acquired for measurements of the same parameters. We determined EFW using Hadlock's formula. Systematic errors between 3D-US and 2D-US were examined using the paired t-test. Reliability and agreement were assessed by intraclass correlation coefficients (ICCs), limits of agreement (LoA), SD of differences and proportion of differences below arbitrary points. Results We evaluated 102 singleton pregnancies. No significant systematic error between 2D-US and 3D-US was observed. The ICC values were higher for 3D-US in both intra- and interobserver evaluations; however, only for FL was there no overlap in the 95% CI. The LoA values were wider for 2D-US, suggesting that random errors were smaller when using 3D-US. Additionally, we observed that the SD values determined from 3D-US differences were smaller than those obtained for 2D-US. Higher proportions of differences were below the arbitrarily defined cut-off points when using 3D-US. Conclusion 3D-US improved the reliability and agreement of fetal measurements and EFW compared with 2D-US.
Resumo:
Objectives. To evaluate whether the overall dysphonia grade, roughness, breathiness, asthenia, and strain (GRBAS) scale, and the Consensus Auditory Perceptual Evaluation-Voice (CAPE-V) scale show the same reliability and consensus when applied to the same vocal sample at different times. Study Design. Observational cross-sectional study. Methods. Sixty subjects had their voices recorded according to the tasks proposed in the CAPE-V scale. Vowels /a/ and /i/ were sustained between 3 and 5 seconds. Reproduction of six sentences and spontaneous speech from the request "Tell me about your voice" were analyzed. For the analysis of the GRBAS scale, the sustained vowel and reading tasks of the sentences was used. Auditory-perceptual voice analyses were conducted by three expert speech therapists with more than 5 years of experience and familiar with both the scales. Results. A strong correlation was observed in the intrajudge consensus analysis, both for the GRBAS scale as well as for CAPE-V, with intraclass coefficient values ranging from 0.923 to 0.985. A high degree of correlation between the general GRBAS and CAPE-V grades (coefficient = 0.842) was observed, with similarities in the grades of dysphonia distribution in both scales. The evaluators indicated a mild difficulty in applying the GRBAS scale and low to mild difficulty in applying the CAPE-V scale. The three evaluators agreed when indicating the GRBAS scale as the fastest and the CAPE-V scale as the most sensitive, especially for detecting small changes in voice. Conclusions. The two scales are reliable and are indicated for use in analyzing voice quality.
Resumo:
Aim. The aim of this study was to evaluate the internal reliability and validity of the BrazilianPortuguese version of Duke Anticoagulation Satisfaction Scale (DASS) among cardiovascular patients. Background. Oral anticoagulation is widely used to prevent and treat thromboembolic events in several conditions, especially in cardiovascular diseases; however, this therapy can induce dissatisfaction and reduce the quality of life. Design. Methodological and cross-sectional research design. Methods. The cultural adaptation of the DASS included the translation and back-translation, discussions with healthcare professionals and patients to ensure conceptual equivalence, semantic evaluation and instrument pretest. The BrazilianPortuguese version of the DASS was tested among subjects followed in a university hospital anticoagulation outpatient clinic. The psychometric properties were assessed by construct validity (convergent, known groups and dimensionality) and internal consistency/reliability (Cronbachs alpha). Results. A total of 180 subjects under oral anticoagulation formed the baseline validation population. DASS total score and SF-36 domain correlations were moderate for General health (r = -0.47, p < 0.01), Vitality (r = -0.44, p < 0.01) and Mental health (r = -0.42, p < 0.01) (convergent). Age and length on oral anticoagulation therapy (in years) were weakly correlated with total DASS score and most of the subscales, except Limitation (r = -0.375, p < 0.01) (Known groups). The Cronbachs alpha coefficient was 0.79 for the total scale, and it ranged from 0.76 (hassles and burdens)0.46 (psychological impact) among the domains, confirming the internal consistency reliability. Conclusions. The BrazilianPortuguese version of the DASS has shown levels of reliability and validity comparable with the original English version. Relevance to clinical practice. Healthcare practitioners and researchers need internationally validated measurement tools to compare outcomes of interventions in clinical management and research tools in oral anticoagulation therapy.
Resumo:
Abstract Background Most of the instruments available to measure the oral health-related quality of life (OHRQoL) in paediatric populations focus on older children, whereas parental reports are used for very young children. The scale of oral health outcomes for 5-year-old children (SOHO-5) assesses the OHRQoL of very young children through self-reports and parental proxy reports. We aimed to cross-culturally adapt the SOHO-5 to the Brazilian Portuguese language and to assess its reliability and validity. Findings We tested the quality of the cross-cultural adaptation in 2 pilot studies with 40 children aged 5–6 years and their parents. The measurement was tested for reliability and validity on 193 children that attended the paediatric dental screening program at the University of São Paulo. The children were also clinically examined for dental caries. The internal consistency was demonstrated by a Cronbach's alpha coefficient of 0.90 for the children’s self-reports and 0.77 for the parental proxy reports. The test-retest reliability results, which were based on repeated administrations on 159 children, were excellent; the intraclass correlation coefficient was 0.98 for parental and 0.92 for child reports. In general, the construct validity was satisfactory and demonstrated consistent and strong associations between the SOHO-5 and different subjective global ratings of oral health, perceived dental treatment need and overall well-being in both the parental and children’s versions (p < 0.001). The SOHO-5 was also able to clearly discriminate between children with and without a history of dental caries (mean scores: 5.8 and 1.1, respectively; p < 0.001). Conclusion The present study demonstrated that the SOHO-5 exhibits satisfactory psychometric properties and is applicable to 5- to 6-year-old children in Brazil.
Resumo:
This paper addresses the functional reliability and the complexity of reconfigurable antennas using graph models. The correlation between complexity and reliability for any given reconfigurable antenna is defined. Two methods are proposed to reduce failures and improve the reliability of reconfigurable antennas. The failures are caused by the reconfiguration technique or by the surrounding environment. These failure reduction methods proposed are tested and examples are given which verify these methods.
Resumo:
Background and Study Aim: The grip strength endurance is important for Brazilian Jiu-Jitsu (BJJ). Thus, the aims of this study were: a) to test the reliability of two kimono grip strength tests named maximum static lift (MSL) and maximum number of repetitions (MNR) and b) to examine differences between elite and non-elite BJJ players in these tests. Material/Methods: Thirty BJJ players participated into two phases: "A" to test reliability and "B" to compare elite and non-elite. In phase A, twenty participants performed the MSL and, 15 min later, the MNR in two occasions with 24-h interval. In phase B, ten other BJJ practitioners (non-elite) and ten athletes (elite) performed the same tests. The intraclass correlation coefficient (ICC) two way fixed model (3,1), Bland-Altman plot and the limits of agreement were used to test reliability, correlation between the tests were evaluated by Pearson correlations and independent T test (P<0.05) was utilized to compare elite vs. non-elite. Results: The ICC was high for repeated measurements on different days of phase A (MSL: r=0.99 and MNR: r=0.97). Limits of agreement for time of suspension were -6.9 to 2.4-s, with a mean difference of -2.3 s (CI: -3.3 to -1.2-s), while for number of repetitions the limits of agreement were -2.9 to 2.3-rep, with a mean difference of -0.3-rep (CI: -0.9 to 0.3-rep). In phase B, elite presented better performance for both tests (P<0.05) compared to non-elite (56 +/- 10-s vs. 37 +/- 11-s in MSL and 15 +/- 4-rep vs. 8 +/- 3-rep in MNR). Moderate correlation were found between MSL and MNR for absolute values during test (r=0.475; p=0.034), and retest phases (r=0.489; p=0.029), while moderate and high correlations in the test (r=0.615; p=0.004) and retest phases (r=0.716; p=0.001) were found for relative values, respectively. Conclusions: These proposed tests are reliable and both static and dynamic grip strength endurance tests seem to differentiate BJJ athletes from different levels.
Resumo:
STUDY DESIGN: Clinical measurement. OBJECTIVE: To translate and culturally adapt the Lower Extremity Functional Scale (LEFS) into a Brazilian Portuguese version, and to test the construct and content validity and reliability of this version in patients with knee injuries. BACKGROUND: There is no Brazilian Portuguese version of an instrument to assess the function of the lower extremity after orthopaedic injury. METHODS: The translation of the original English version of the LEFS into a Brazilian Portuguese version was accomplished using standard guidelines and tested in 31 patients with knee injuries. Subsequently, 87 patients with a variety of knee disorders completed the Brazilian Portuguese LEES, the Medical Outcomes Study 36-Item Short-Form Health Survey, the Western Ontario and McMaster Universities Osteoarthritis Index, and the International Knee Documentation Committee Subjective Knee Evaluation Form and a visual analog scale for pain. All patients were retested within 2 days to determine reliability of these measures. Validation was assessed by determining the level of association between the Brazilian Portuguese LEFS and the other outcome measures. Reliability was documented by calculating internal consistency, test-retest reliability, and standard error of measurement. RESULTS: The Brazilian Portuguese LEES had a high level of association with the physical component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.82), the Western Ontario and McMaster Universities Osteoarthritis Index (r = 0.87), the International Knee Documentation Committee Subjective Knee Evaluation Form (r = 0.82), and the pain visual analog scale (r = -0.60) (all, P<.05). The Brazilian Portuguese LEES had a low level of association with the mental component of the Medical Outcomes Study 36-Item Short-Form Health Survey (r = 0.38, P<.05). The internal consistency (Cronbach alpha = .952) and test-retest reliability (intraclass correlation coefficient = 0.957) of the Brazilian Portuguese version of the LEES were high. The standard error of measurement was low (3.6) and the agreement was considered high, demonstrated by the small differences between test and retest and the narrow limit of agreement, as observed in Bland-Altman and survival-agreement plots. CONCLUSION: The translation of the LEFS into a Brazilian Portuguese version was successful in preserving the semantic and measurement properties of the original version and was shown to be valid and reliable in a Brazilian population with knee injuries. J Ort hop Sports Phys Ther 2012;42(11):932-939, Epub 9 October 2012. doi:10.2519/jospt.2012.4101
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Although traditionally obsessive-compulsive disorder (OCD) and impulse control disorders (ICD) have represented opposing ends of a continuum, recent research has demonstrated a frequent co-occurrence of impulsive and compulsive behaviours, which may contribute to a worse clinical picture of some psychiatric disorders. We hypothesize that individuals with 'impulsive' OCD as characterized by poor insight, low resistance, and reduced control towards their compulsions will have a deteriorative course, greater severity of hoarding and/or symmetry/ordering symptoms, and comorbid ICD and/or substance use disorders (SUD). The sample consisted of 869 individuals with a minimum score of 16 on the Yale-Brown Obsessive Compulsive Scale (Y-BOCS). Of these, 65 had poor insight, low resistance, and reduced control towards compulsions ('poor IRC') and 444 had preserved insight, greater resistance and better control over compulsions ('good IRC'). These two groups were compared on a number of clinical and demographic variables. Individuals with poor IRC were significantly more likely to have a deteriorative course (p < 0.001), longer duration of obsessions (p = 0.017), greater severity of symmetry/ordering (p < 0.001), contamination/cleaning (p < 0.001) and hoarding (p = 0.002) symptoms, and comorbid intermittent explosive disorder (p = 0.026), trichotillomania (p = 0.014) and compulsive buying (p = 0.040). Regression analysis revealed that duration of obsessions (p = 0.037) and hoarding severity (p = 0.005) were significant predictors of poor IRC. In the absence of specific measures for impulsivity in OCD, the study highlights the utility of simple measures such as insight, resistance and control over compulsions as a phenotypic marker of a subgroup of OCD with impulsive features demonstrating poor clinical outcome. (C) 2012 Elsevier Ltd. All rights reserved.