191 resultados para Shanghai Expo


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We found reversible dark-center diffraction of the transmitted probe beam passing through the chromium film. which is induced by the pump femtosecond laser. The dark-center diffraction of I he transmitted probe beam appears and disappears with and without the pump beam. A view of diffractive optics with binary phase plate is put forward, which explains the reversible dark-center diffractive optical phenomenon. The pre-ablated hole on the metal film can be regarded as a uniform light filed without phase modulation, the Surrounding Circular part around the pre-ablated hole can be regarded as "phase modulated". Therefore, this diffraction optic view might be helpful for us to understand the phase change of the metal film introduced by the femtosecond laser pulse. (C) 2008 Elsevier B.V, All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

提出了一种基于同步移相技术的1/4波片相位延迟量的快速测量方法。由正交光栅、光阑、检偏器组和四象限探测器实现同步移相功能。检偏器组由4个不同方位角的检偏器组成。通过检偏器组的四束光束的光强由四象限探测器同时测量。1/4波片的相位延迟量由这四光束的光强得到。该方法中波片的快轴不需被事先确定。另外光源光强的波动对测量结果没有影响。通过实验验证了该方法的有效性。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose a miniature pulse compressor that can be used to compensate the group velocity dispersion that is produced by a commercial femtosecond laser cavity. The compressor is composed of two identical highly efficient deep-etched transmissive gratings. Compared with prism pairs, highly efficient deep-etched transmissive grating pairs are lightweight and small. With an optimized groove depth and a duty cycle, 98% diffraction efficiency of the -1 transmissive order can be achieved at a wavelength of 800 nm under Littrow conditions. The deep-etched gratings are fabricated in fused silica by inductively coupled plasma etching. With a pair of the fabricated gratings, the input positively chirped 73.9 fs pulses are neatly compressed into the nearly Fourier transform-limited 43.2 fs pulses. The miniature deep-etched grating-based pulse compressor should be of interest for practical applications. (c) 2008 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Modal analysis of a deep-etched low-contrast two-port beam splitter grating under Littrow Mounting is presented. The guideline for the design of a subwavelength transmission fused-silica phase grating as high-efficiency grating, polarizing beam splitter (PBS), and two-port beam splitter, is summarized. As an example, a polarization-independent two-port beam splitter grating is designed at wavelength of 1064 nm. We firstly analyzed the physical essence of the grating by the simplified modal method. The guideline for the grating design and the approximate grating parameters are obtained. Then using the rigorous coupled-wave analysis (RCWA) with parameters varying around the approximate ones, Optimum grating parameters can be determined. With the design guideline, the time for the rigorous calculation of the grating profile parameters can be reduced significantly. (C) 2008 Elsevier B.V. All rights reserved

Relevância:

10.00% 10.00%

Publicador:

Resumo:

本文结合有限元方法和超快热弹性模型对飞秒激光辐射下形成的微突起结构进行了数值模拟研究。模拟结果表明微突起结构的形成与入射飞秒激光的参数以及材料的热弹性质有关。在圆锥状微突起结构的形状和高度方面,实验结果与模拟结果呈现良好的一致性,这也从实验上表明了超快热弹性模型的有效性。本文的研究将有助于利用超快激光对薄膜材料进行纳米构造。

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ultrafast lasers ablation of Cr film was investigated by using double-pulse method. Experimental results show that there exists a temporal ablation window effect with each of the double pulses adjusted just smaller than the threshold. When the delay between the double pulses is within the order of 400 ps, the ablation of Cr film could happen. When the delay between the double pulses is beyond the order of 400 ps, the ablation of Cr film would not happen, and the reflectivity from the surface of the Cr film shows a sharp rise at the same time. The two-temperature model was developed into the form of double pulses to explain the experimental phenomena. Furthermore, microbump structures were formed on the surface of Cr film after ablation by ultrafast double pulses. Their heights exhibit an obvious drop between 1 and 10 ps double pulses delay, which is involved with the electron-phonon coupling process according to the numerical simulation. These results should be helpful for understanding the dynamic processes during ultrafast lasers ablation of metal films. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A deep-etched polarization-independent binary fused-silica phase grating as a three-port beam splitter is designed and manufactured. The grating profile is optimized by use of the rigorous coupled-wave analysis around the 785 nm wavelength. The physical explanation of the grating is illustrated by the modal method. Simple analytical expressions of the diffraction efficiencies and modal guidelines for the three-port beam splitter grating design are given. Holographic recording technology and inductively coupled plasma etching are used to manufacture the fused-silica grating. Experimental results are in good agreement with the theoretical values. (c) 2008 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We theoretically investigated the design of a metal-mirror-based reflecting polarizing beam splitter (RPBS). The metal mirror is a silver slab, which is embedded in the substrate of a rectangular silica transmission grating. By using a modal analysis and rigorous coupled-wave analysis, an RPBS grating is designed for operation at 1550 nm. When it is illuminated in Littrow mounting, the transverse electric (TE) and transverse magnetic (TM) waves will be mainly reflected in the minus-first and zeroth orders, respectively. Moreover, a wideband RPBS grating is obtained by adopting the simulated annealing algorithm. The RPBS gratings exhibit high diffraction efficiencies (similar to 95%) and high extinction ratios over a certain angle and wavelength range, especially for the minus-first-order reflection. This kind of RPBS should be useful in practical optical applications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inverse symmetric Dammann grating is a special grating, whose transition points are reflection symmetric about the midpoint with inverse phase offset in one period. It can produce even-numbered or odd-numbered array illumination when the phase modulations are pi or a specific value. Numerical solutions optimized by the steepest-descent algorithm for binary phase and multilevel phases with splitting ratio from I x 4 to 1 x 14 are given. Fabrication of 1 x 6 array without the zero-order intensity and 1 x 7 array with the zero-order intensity are made from the same amplitude mask. A 6 x 6 output without the crossed zero-orders was achieved by crossing two one-dimensional 1 x 6 inverse symmetric Dammann gratings. This grating may have potential value for practical applications. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The correlation between the coma sensitivity of the alternating phase-shifting mask (Alt-PSM) mark and the mark's structure is studied based on the Hopkins theory of partially coherent imaging and positive resist optical lithography (PROLITH) simulation. It is found that an optimized Alt-PSM mark with its phase width being two-thirds its pitch has a higher sensitivity to coma than Alt-PSM marks with the same pitch and the different phase widths. The pitch of the Alt-PSM mark is also optimized by PROLITH simulation, and the structure of p - 1.92 lambda/NA and pw = 2p/3 proves to be with the highest sensitivity. The optimized Alt-PSM mark is used as a measurement mark to retrieve coma aberration from the projection optics in lithographic tools. In comparison with an ordinary Alt-PSM mark with its phase width being a half its pitch, the measurement accuracies of Z(7) and Z(14) apparently increase. (C) 2009 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present paper, we propose a novel method for measuring the even aberrations of lithographic projection optics by use of optimized phase-shifting marks on the test mask. The line/space ratio of the phase-shifting marks is optimized to obtain the maximum sensitivities of Zernike coefficients corresponding to even aberrations. Spherical aberration and astigmatism can be calculated from the focus shifts of phase-shifting gratings oriented at 0 degrees, 45 degrees, 90 degrees and 135 degrees at multiple illumination settings. The PROLITH simulation results show that, the measurement accuracy of spherical aberration and astigmatism obviously increase, after the optimization of the measurement mark. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As there exist some problems with the previous laser diode (LD) real-time microvibration measurement interferometers, such as low accuracy, correction before every use, etc., in this paper, we propose a new technique to realize the real-time microvibration measurement by using the LD sinusoidal phase-modulating interferometer, analyze the measurement theory and error, and simulate the measurement accuracy. This interferometer utilizes a circuit to process the interference signal in order to obtain the vibration frequency and amplitude of the detective signal, and a computer is not necessary in it. The influence of the varying light intensity and light path difference on the measurement result can be eliminated. This technique is real-time, convenient, fast, and can enhance the measurement accuracy too. Experiments show that the repeatable measurement accuracy is less than 3.37 nm, and this interferometer can be applied to real-time microvibration measurement of the MEMS. (C) 2007 Elsevier GmbH. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A dissolved oxygen sensor made of plastic optical fiber as the substrate and dichlorotris (1, 10-phenanthroline) ruthenium as a fluorescence indicator is studied. Oxygen quenching characteristics of both intensity and phase were measured; the obtained characteristics showed deviation from the linear relation described by the Stern-Volmer equation. A two-layer model is proposed to explain the deviation, and main parameters can be deduced with the model. (C) 2009 Optical Society of America

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Z-scan technique is useful for measuring the nonlinear refractive index of thin films. In conventional Z-scan theories, two effects are often ignored, namely the losses due to the internal multi-interference and the nonlinear absorption inside the sample. Therefore, the theories are restricted to relatively thick films. For films thinner than about 100 nm, the two effects become significant, and thus cannot be ignored. In the present work, we present a Z-scan theory that takes both effects into account. The proposed model calculation is suitable for optical nonlinear films of nanometric thickness. With numerical simulations, we demonstrate dramatic deviations from the conventional Z-scan calculations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

采用有损耗介质和色散介质的二维时域有限差分方法,数值模拟了以光波长514.5 nm的p偏振基模高斯光束为入射光源,激发Kretschmann型表面等离子体共振,并通过探针的局域场增强效应实现纳米光刻的新方法——探针诱导表面等离子体共振耦合纳米光刻.分别就探针与记录层的间距以及探针针尖大小,模拟分析了不同情况下探针的局域场增强效应和记录层表面的相对电场强度振幅分布.结果表明,探针工作在接触模式时,探针的局域场增强效应最明显,记录层表面的相对电场强度振幅的对比度最大;当探针针尖距记录层5 nm时,针尖下方记录层表面的相对电场强度振幅大于光刻临界值的分布宽度与针尖尺寸相近.