93 resultados para Signalto Noise Ratio (SNR)
Resumo:
The conventional TbFeCo magneto-optical (MO) medium has a relatively smaller Kerr rotation angle in the blue region than in the red. With the recording wavelength gradually moving to the short wavelength, if TbFeCo is still used as recording medium, the conventional MO disk structure must be optimized to get a larger carrier to noise ratio (CNR). Sabi et al. have found that adding a metal layer attached to the TbFeCo film as thermal control layer is a useful way to get a high CNR. In this paper, we proved this through calculation, and carried out optimization of the new type of disk. Calculation results showed that the new structure is useful in preventing an excessive temperature increase, and has a better thermal response. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
Sb-Bi alloy films are proposed as a new kind of super-resolution mask layer with low readout threshold power. Using the Sb-Bi alloy film as a mask layer and SiN as a protective layer in a read-only memory disc, the super-resolution pits with diameters of 380 nm are read out by a dynamic setup, the laser wavelength is 780 nm and the numerical aperture of pickup lens is 0.45. The effects of the Sb-Bi thin film thickness, laser readout power and disc rotating velocity on the readout signal are investigated. The results show that the threshold laser power of super-resolution readout of the Sb-Bi mask layer is about 0.5 mW, and the corresponding carrier-to-noise ratio is about 20 dB at the film thickness of 50 nm. The super-resolution mechanism of the Sb-Bi alloy mask layer is discussed based on its temperature dependence of reflection.
Resumo:
为使星载激光高度计实现高空间分辨力、高距离精度,提出了联合采用调频光纤激光器和相干测距的方法。详细讨论了这种方法的实现方案,并对方案中的激光发射功率、望远镜口径以及脉冲宽度对距离精度及信噪比的影响进行数值模拟。对系统参量进行分析,得到了相关参量的关系和优化的参量。结果表明,当望远镜口径为400 mm时,啁啾调频速率为1 MHz/μs,脉冲时间宽度150~350μs,发射功率10 W左右时,基于相干测距的星载激光高度计可以实现距离精度小于15 cm的技术指标。
Resumo:
The characteristics of media in communication channel are analyzed briefly and the reasonable optical parameters of media are adopted. With certain communication system parameters the temporal and spatial distributions of the received signal from submerged platform are simulated using Monte Carlo method. The upper limit of the ratio of Monte Carlo estimated error to averaged value is about 0.3%. From the simulated results, the optimized sampling timing of receiver and field of view of telescope are obtained. Also the signal-to-noise ratio of the receiver is calculated. Based on this, the error probability of the communication system is deduced from laser pulse position modulation and maximum likelihood detection. The results show that under severe environment robust laser communication from a satellite to a submerged platform can be achieved.
Resumo:
全面对采用空间分集技术和时域Rake接收机分集的带限空间光通信系统的原理进行了模拟和分析,首次在空间激光通信领域提出了综合了分集接收和均衡技术的联合信道均衡器方法,通过计算机仿真分析,研究了不同空间分集方法在非相关空间光开关键控信号下的误比特率,在不同符号间干扰条件下采用rake接收时的误比特率,以及在不同信噪比和不同信道数时采用联合分集均衡的误码率。研究的结果确认联合分集均衡方法能够明显的提高空间光通信系统的性能。
Resumo:
研制成功便携式激光尘埃粒子计数器的核心部件——微型光学传感器。该传感器采用直角散射光收集形式。以高功率半导体激光器作为光源,同时采用高性能的PIN型光电二极管作为光电探测器。散射光收集系统为单一大数值孔径的球面反射镜,其对粒子散射光的收集角范围从20°到160°。粒子散射光信号是脉冲信号,其频谱成份主要在高频段,所以在PIN型光电二极管后用一个带通式前置放大器来消除外界的低频噪声.根据米氏散射理论计算了该光学传感器的光散射响应特性,并用聚苯乙烯标准粒子实测了该光学传感器的性能。结果表明,该系统具有高的信噪
Resumo:
在千焦拍瓦高功率啁啾脉冲放大系统设计中,为了尽量消除增益窄化和增益饱和效应的影响,同时尽可能提高高功率激光输出脉冲信噪比参数,激光脉冲时空和光谱的整形问题备受关注.提出一种光谱整形新方法,利用特定结构的多层介质膜反射镜,可实现对大能量高功率啁啾脉冲钕玻璃放大系统中啁啾脉冲的光谱整形.研究结果表明,只要合理选择多层介质膜系的结构参数,可有效地控制其反射率分布,且在保证反射相位基本不变的条件下其调制度可超过60%.针对钕玻璃1053nm波长设计而成的光谱整形反射镜,反射带宽可达到196nm,色分辨率约为0.1nm,在几十纳米波长范围所对应的相位偏差小于12mrad,相当于λ/524,能够满足"神光Ⅱ"千焦拍瓦改造的技术指标要求.
Resumo:
We report on the study of a single-photon-emitting diode at 77 K. The device is composed of InAs/GaAs quantum dots embedded in the i-region of a p-i-n diode structure. The high signal to noise ratio of the electroluminescence, as well as the small second order correlation function at zero-delay g((2))(0), implies that the device has a low multiphoton emission probability. By comparing the device performances under different excitation conditions, we have, in detail, discussed the basic parameters, such as signal to noise ratio and g((2))(0), and provided some useful information for the future application. (c) 2008 American Institute of Physics.
Resumo:
Silicon-on-insulator (SOI) substrate is widely used in micro-electro-mechanical systems (MEMS). With the buried oxide layer of SOI acting as an etching stop, silicon based micro neural probe can be fabricated with improved uniformity and manufacturability. A seven-record-site neural probe was formed by inductive-coupled plasma (ICP) dry etching of an SOI substrate. The thickness of the probe is 15 mu m. The shaft of the probe has dimensions of 3 mmx100 mu mx15 mu m with typical area of the record site of 78.5 mu m(2). The impedance of the record site was measured in-vitro. The typical impedance characteristics of the record sites are around 2 M Omega at 1 kHz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 mu V. Spike from individual site could exceed 700 mu V. The average signal noise ratio was 7 or more.
Resumo:
Qubit measurement by mesoscopic charge detectors has received great interest in the community of mesoscopic transport and solid-state quantum computation, and some controversial issues still remain unresolved. In this work, we revisit the continuous weak measurement of a solid-state qubit by single electron transistors (SETs) in nonlinear-response regime. For two SET models typically used in the literature, we find that the signal-to-noise ratio can violate the universal upper bound "4," which is imposed quantum mechanically on linear-response detectors. This different result can be understood by means of the cross correlation of the detector currents by viewing the two junctions of the single SET as two detectors. Possible limitation of the potential-scattering approach to this result is also discussed.
Resumo:
A stabilized and tunable single-longitudinal-mode erbium-doped fiber ring laser has been proposed and experimentally demonstrated. The laser is structured by combining the compound cavity with a fiber Fabry-Perot tunable filter. An injection-locking technique has been used to stabilize the wavelength and output power of the laser. One of the longitudinal modes is stimulated by the injected continuous wave so that this mode is able to win the competition to stabilize the system. A minimum output power of 0.6 dBm and a signal-to-noise ratio of over 43 dB within the tuning range of 1527-1562 nm can be achieved with the proposed technique. A wavelength variation of less than 0.01 nm, a power fluctuation of less than 0.02 dB, and a short-term linewidth of about 1.4 kHz have also been obtained.
Resumo:
Both Fourier transform infrared (FTIR) grazing incidence reflectivity and FTIR transmission methods have been used to study GaN films grown on alpha-Al2O3 (0001) substrates by atmospheric pressure metal-organic chemical vapor deposition and low pressure metal-organic chemical vapor deposition. The results show that in the frequency range from 400 to 3500 cm(-1) the signal-to-noise ratio of the FTIR grazing incidence measurement is far higher than that of the FTIR transmission measurement. Some new vibrational structures appearing in the former measurement have been discussed. The features around 1460 and 1300 cm(-1) are tentatively assigned to scissoring and wagging local vibrational modes of CH2 in GaN, respectively. (C) 1999 American Institute of Physics. [S0021-8979(99)06509-3].
Resumo:
In this paper we consider the continuous weak measurement of a solid-state qubit by single electron transistors (SET). For single-dot SET, we find that in nonlinear response regime the signal-to-noise ratio can violate the universal upper bound imposed quantum mechanically on any linear response detectors. We understand the violation by means of the cross-correlation of the detector currents. For double-dot SET, we discuss its robustness against wider range of temperatures, quantum efficiency, and the relevant open issues unresolved.
Resumo:
Extracellular neural recording requires neural probes having more recording sites as well as limited volumes. With its mechanical characteristic and abundant process method, Silicon is a kind of material fit for producing neural probe. Silicon on insulator (SOI) is adopted in this paper to fabricate neural probes. The uniformity and manufacturability are improved. The fabricating process and testing results of a series of Multi channel micro neural probes were reported. The thickness of the probe is 15 mu m-30 mu m. The typical impedance characteristics of the record sites are around 2M Omega at 1k Hz. The performance of the neural probe in-vivo was tested on anesthetic rat. The recorded neural spike was typically around 140 mu V. Spike recorded from individual site could exceed 700 mu V. The average signal noise ratio was 7 or more.
Resumo:
For night remote surveillance, we present a method, the range-gated laser stroboscopic imaging(RGLSI), which uses a new kind of time delay integration mode to integrate target signals so that night remote surveillance can be realized by a low-energy illuminated laser. The time delay integration in this method has no influence on the video frame rate. Compared with the traditional range-gated laser imaging, RGLSI can reduce scintillation and target speckle effects and significantly improve the image signal-to-noise ratio analyzed. Even under low light level and low visibility conditions, the RGLSI system can effectively work. In a preliminary experiment, we have detected and recognized a railway bridge one kilometer away under a visibility of six kilometers, when the effective illuminated energy is 29.5 mu J.