90 resultados para EPR test
Resumo:
The encircled energy of a focusing lens is one of the parameters directly affecting the target efficiency in high-power laser facilities. The direct measurement method of the encircled energy for the focusing lens based on the scanning Hartmann test is proposed in this paper. With the scanning Hartmann test setup, the information in the whole aperture of the focusing lens can be achieved. The encircled energy can be obtained by analyzing the spot diagram on the focal plane of the focusing lens. In experiments, the encircled energy of an aspheric focusing lens is measured using this method. The measurement result is in good agreement with that derived from measurement data by an interferometer and the difference is 7.7%. (C) 2006 Elsevier GmbH. All rights reserved.
Resumo:
种子贮藏稳定性对于种质资源的长期保存具有重要意义,目前关于种子贮藏的最新理论为玻璃态理论,该理论认为种子的玻璃化有利于种子的长期贮藏。当种子处于玻璃态时,玻璃化物质的高度粘滞性降低了种子细胞内分子流动性,阻止了细胞质中分子的扩散,从而减少老化过程中细胞结构的损伤和化学组分的变化,延缓种子老化劣变反应速率,延长贮藏寿命。评价玻璃态的一个重要指标是玻璃化转变温度,当种子贮藏于玻璃化温度或以下10℃~30℃范围内时,种子具有最佳的贮藏稳定性。因此,检测种子的玻璃化转变温度对于种子的长期有效贮藏具有重要指导意义。 本研究将差示量热扫描技术(DSC)与电子顺磁共振波谱仪技术(EPR)应用于杜仲种子玻璃化转变温度方面的研究。在DSC方法中,选用4.4%~31.6%含水量范围的杜仲种胚分别进行了DSC图谱扫描。EPR方法选用3-羧基-2,2,5,5-四甲基吡咯烷-1-氧(3-carboxy-2,2,5,5-tetramethylpyrrolidine-1-oxyl,CP)和2,2,6,6-四甲基哌啶(4-hydroxy-2,2,6,6-tetramethyl-1-piperidinyloxy,TEMPO)作为探针标记杜仲种胚, 利用EPR技术测定不同含水量杜仲种胚的分子运动,通过对EPR图谱参数的分析计算,最终确定不同含水量杜仲种胚的玻璃化转变温度。 DSC实验结果显示,含水量为22.3%、28.0%、31.6%的杜仲种胚在0℃ 左右出现了一个水的熔融峰。该熔融峰的面积代表了自由水含量的多少,随着种胚含水量的降低该熔融峰面积减小。4.4%~31.6%含水量范围的杜仲种胚在-28℃左右还出现了一个熔融峰,推测此峰为杜仲种胚中某类物质熔融所形成的熔融峰。然而在此曲线上我们未观察到标志玻璃化转变的“台阶”出现。 CP-EPR实验的结果表明,利用EPR测定得到含水量为4.4%~11.6%的杜仲种胚在-110℃~20℃温度范围内,同一含水量的杜仲种胚随着温度的升高,分子运动速率加快;在同一温度条件下,高含水量的种胚比低含水量种胚的分子运动速率快。通过CP-EPR波谱两外缘峰最大距离(2Azz)的测定和数据统计分析,得到含水量为4.4%、5.7%、8.6%、10.3%、11.6%杜仲种胚的玻璃化转变温度分别约为44℃、25℃、4℃、-31℃、-43℃。可以把测定的杜仲种胚的这几个含水量的玻璃化转变温度与杜仲种子贮藏相结合,用于指导杜仲种子的贮藏。 TEMPO-EPR实验测定分析得到含水量为2.1%、3.4%、4.8%、8.3%、11.2% 的杜仲种胚的玻璃化转变温度分别为-21℃、-18℃、-24℃、-20℃、-27℃,玻璃化转变温度随含水量升高其变化的规律不明显,这与CP-EPR实验测得的结果有着较明显的差别。通过分析,认为对于脂质含量较高的杜仲种胚,随着含水量的降低,作为标记化合物的TEMPO随着脱水进入脂相,从而不能真实反映出不同含水量种胚的分子运动情况。与TEMPO标记相比,CP标记可能能够更真实地反映不同含水量杜仲种胚细胞质分子运动的情况,根据其分子运动情况得到的玻璃化转变温度更准确。
Resumo:
The present study aimed to establish a sensitive in vitro assay to assess the binding capacity of cat spermatozoa. Cat oocytes and epididymal sperm cells were isolated from gonads and cultured for in vitro fertilization. Before fertilization, the sperm ce
Resumo:
Perfluorooctane sulfonate (PFOS) is widely distributed and persistent in the environment and wildlife. The main aim of this study was to investigate the impact of long-term exposure to low concentrations of PFOS in zebrafish. Zebrafish fry (F-0, 14d post-fertilization, dpf) were exposed via the water for 70d to 0 (control), 10, 50 and 250 mu g L-1 PFOS, followed by a further 30d to assess recovery in clean water. The effects on survival and growth parameters and liver histopathology were assessed. Although growth suppression (weight and length) was observed in fish treated with high concentrations PFOS during the exposure period, no mortality was observed throughout the 70d experiment. Embryos and larvae (F-1) derived from maternal exposure suffered malformation and mortality. Exposure to 50 and 250 mu g L-1 PFOS could inhibit the growth of the gonads (GSI) in the female zebrafish. Histopathological alterations, primary with lipid droplets accumulation, were most prominently seen in the liver of males and the changes were not reversible, even after the fish were allowed to recover for 30d in clean water. The triiodothyronine (T-3)) levels were not significantly changed in any of the exposure groups. Hepatic vitellogenin (VTG) gene expression was significantly up-regulated in both male and female zebrafish, but the sex ratio was not altered. The overall results suggested that lower concentrations of PFOS in maternal exposure could result in offspring deformation and mortality. (c) 2008 Elsevier Ltd. All rights reserved.
Resumo:
Chinese rare minnow (Gobiocypris rarus), a freshwater teleost,. was exposed to diethylstilbestrol (DES) at 0.05, 0.5, 1 and 5 mug/L from fertilized eggs for up to mature period under flow-through condition. Several endpoints that related to development, reproductive fitness and transgenerational effects were evaluated. It was found that body length and body weight were significantly reduced and vitellogenin (Via) levels were significantly increased for fish exposed to DES. Histological examination showed that the sex ratios of F-0 fish skewed to female and about 2% of the fish exposed to 0.05 mug/L DES developed testes-ova. The reproductive success, as determined from data on egg production, was reduced in female fish exposed to 0.05, 0.5, 1 and 5 mug/L DES. The lowest-observed-effect concentrations (LOEC) for chances of sex ratios, reproductive success and histology alteration of F-0 are 0.05 mug/L. In the offspring, transgenerational effects on egg hatching rate. egg fertilization and Vtg levels of juvenile individuals were not observed. However. survival of F, generation fry significantly declined. The analysis of sex steroid levels revealed a significant decrease of testosterone (T) in the whole body homogenates (WBH) of male progeny and somewhat elevation of estradiol (E-T) in the WBH of female offspring. These findings indicate that exposure to DES causes a variety of developmental, reproductive and transgenerational effects. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Submitted by zhangdi (zhangdi@red.semi.ac.cn) on 2009-04-13T11:45:31Z
Resumo:
A new method to test the hole concentration of p-type GaN is proposed, which is carried out by analyzing the spectral response of p-n(+) structure GaN ultraviolet photodetector. It is shown that the spectral response of the photodetector changes considerably with reversed bias. It is found that the difference between photodetector's quantum efficiency at two wavelengths, i.e. 250 and 361 nm, varies remarkably with increasing reversed bias. According to the simulation calculation, the most characteristic change occurs at a reversed voltage under which the p-GaN layer starts to be completely depleted. Based on this effect the carrier concentration of p-GaN can be derived.
Resumo:
This paper reports the mechanical properties and fracture behavior of silicon carbide (3C-SiC) thin films grown on silicon substrates. Using bulge testing combined with a refined load-deflection model of long rectangular membranes, which takes into account the bending stiffness and prestress of the membrane material, the Young's modulus, prestress, and fracture strength for the 3C-SiC thin films with thicknesses of 0.40 and 1.42 mu m were extracted. The stress distribution in the membranes under a load was calculated analytically. The prestresses for the two films were 322 +/- 47 and 201 +/- 34 MPa, respectively. The thinner 3C-SiC film with a strong (111) orientation has a plane-gstrain moduli of 415 +/- 61 GPa, whereas the thicker film with a mixture of both (111) and (110) orientations exhibited a plane-strain moduli of 329 +/- 49 GPa. The corresponding fracture strengths for the two kinds of SiC films were 6.49 +/- 0.88 and 3.16 +/- 0.38 GPa, respectively. The reference stresses were computed by integrating the local stress of the membrane at the fracture over edge, surface, and volume of the specimens and were fitted with Weibull distribution function. For the 0.40-mu m-thick membranes, the surface integration has a better agreement between the data and the model, implying that the surface flaws are the dominant fracture origin. For the 1.42-mu m-thick membranes, the surface integration presented only a slightly better fitting quality than the other two, and therefore, it is difficult to rule out unambiguously the effects of the volume and edge flaws.
Resumo:
The error theory of linear equation system has been applied to the calibration procedure of microwave network analyser in this article. A new explanation for the choice of the linear calibration equations is proposed and a general principle for choosing calibration equations is presented. The method can also be used to predict the occurrence of the problem of frequency limitation at some periodic frequencies. This principle is employed to the thru-short-delay (TSD) method and the solution using the chosen equations gives the most accurate results. A good agreement between the theory and the experiment has been obtained.
Resumo:
Three known standards, including at least one transmission standard, are normally required for the full two-port calibration of test fixtures. Based on the triple-through method, a new general-purpose calibration procedure using only one known reflection standard is proposed in this paper. The experimental results show that our method call provide a simple and accurate approach to fall two-port calibration of the asymmetric test fixtures. (c) 2005 Wiley Periodicals, Inc.
Resumo:
With different implantation energies, nitrogen ions were implanted into SIMOX wafers in our work. And then the wafers were subsequently annealed to form separated by implantation of oxygen and nitrogen (SIMON) wafers. Secondary ion mass spectroscopy (SIMS) was used to observe the distribution of nitrogen and oxygen in the wafers. The result of electron paramagnetic resonance (EPR) was suggested by the dandling bonds densities in the wafers changed with N ions implantation energies. SIMON-based SIS capacitors were made. The results of the C-V test confirmed that the energy of nitrogen implantation affects the properties of the wafers, and the optimum implantation energy was determined. (c) 2005 Elsevier B.V. All rights reserved.
Resumo:
The problem of frequency limitation arising from the calibration of asymmetric and symmetric test fixtures has been investigated. For asymmetric test fixtures, a new algorithm based on the thru-short-match (TSM) method is outlined. It is found that the conventional TSM method does not have any inherent frequency limitation, but using the same procedure with an unknown match may lead to the said problem. This limitation can be avoided by using a different algorithm. The various calibration methods for symmetric test fixtures using known standards are also discussed and the origin of the frequency limitation is identified. Several ways in avoiding the problem are proposed. There is good agreement between the theories and experimental data.