980 resultados para double gloving technique
Resumo:
Purpose: This study was conducted to comparatively evaluate, in a prospective and randomized manner, 2 techniques for providing double-gloving protection during arch bar placement for intermaxillary fixation. Materials and Methods: A total of 42 consecutive patients in whom application of an Erich bar was indicated for intermaxillary fixation were equally divided into 2 groups. In group 1, 2 sterile surgical gloves were used; in group 2, a nonsterile disposable inner glove was used under a sterile surgical glove. Wilcoxon, Mann-Whitney, Kruskal-Wallis, and binomial statistical tests were used to analyze the findings. Results: A total of 103 perforations were found in the outer gloves (47 in group 1 and 56 in group 2), along with 5 perforations in inner gloves in both groups (α = .01). No significant statistical difference was found between groups in terms of inner glove perforations (α = .05). The nondominant hand presented with 70.9% of the perforations, statistically significant to 1%. Conclusions: Both double-gloving techniques were found to provide effective clinician protection. The use of a nonsterile disposable glove under the surgical glove is possible for less-invasive procedures, offering the same safety as using 2 sterile surgical gloves while decreasing operational costs. This method does not eliminate the need to change gloves when a perforation is suspected or noted during the surgery, however. © 2007 American Association of Oral and Maxillofacial Surgeons.
Resumo:
于2010-11-17批量导入
Resumo:
We fabricated a bandpass filter based on Moire Bragg grating in fiber with a uniform phase mask We employed a stretch and two-exposure technique, in which the fiber was exposed to UV light from a KrF excimer through a phase mask and then the fiber is stretched and given another exposure at the same region. Due to the stretch, the periods of these two grating are slightly different, and there is a transmission between two reflection peaks at the Bragg wavelength of these two gratings.Applying different stretch can control the bandpass width of the filter. We measured the stretch characterization of a uniform Bragg grating and found the Bragg wavelength of the grating shifts linearly with the stretched length.We theoretically analyzed the grating structure and its reflection spectrum. The filter's characteristics can be optimized by choosing appropriate parameters. We will give a theoretical discussion concerning which parameters and how they affect the filter's operation.
Resumo:
We have developed a procedure for staining cartilage and bone in fish larvae as small as 2 mm (notochord length), for which standard alcian blue/alizarin red procedures did not give positive and/or consistent results. Small calcified structures only 100-200 pm in length can be clearly visualized. The method is suitable for both ontogenic studies during early stages of skeletal development in most marine fishes (e.g., Sparus aurata L., Solea senegalensis Kaup), whose larvae at hatching are often only a few millimeters long and for detecting skeletal abnormalities in small larvae. This procedure can also be used for specimens that have been preserved in 1000/0 ethanol for up to two years.
Resumo:
We report a technique to palliate hypoplastic left heart syndrome, with no PDA stenting, but with double polytetrafluoroethylene shunt from pulmonary artery to ascending and descending aorta by combined thoracotomies. A 30-day-old female was operated with this technique. Five months after first operation, the child was submitted to Norwood/Glenn operation. Good hemodinamic recovery and initial clinical evolution was observed. The child was extubated in 8th post operatory day and reentubated in the next day due to pulmonary infection. Despite antibiotic treatment, the child died after systemic infectious complications.
Resumo:
Occupational exposures of healthcare workers tend to occur because of inconsistent compliance with standard precautions. Also, incidence of occupational exposure is underreported among operating room personnel. The purpose of this project was to develop national estimates for compliance with standard precautions and occupational exposure reporting practices among operating room nurses in Australia. Data was obtained utilizing a 96-item self-report survey. The Standard Precautions and Occupational Exposure Reporting survey was distributed anonymously to 500 members of the Australian College of Operating Room Nurses. The Health Belief Model was the theoretical framework used to guide the analysis of data. Data was analysed to examine relationships between specific constructs of the Health Belief Model to identify factors that might influence the operating room nurse to undertake particular health behaviours to comply with standard precautions and occupational exposure reporting. Results of the study revealed compliance rates of 55.6% with double gloving, 59.1% with announcing sharps transfers, 71.9% with using a hands-free sharps pass technique, 81.9% with no needle recapping and 92.0% with adequate eye protection. Although 31.6% of respondents indicated receiving an occupational exposure in the past 12 months, only 82.6% of them reported their exposures. The results of this study provide national estimates of compliance with standard precautions and occupational exposure reporting among operating room nurses in Australia. These estimates can now be used as support for the development and implementation of measures to improve practices in order to reduce occupational exposures and, ultimately, disease transmission rates among this high-risk group.
Resumo:
Experiments in spintronics necessarily involve the detection of spin polarization. The sensitivity of this detection becomes an important factor to consider when extending the low temperature studies on semiconductor spintronic devices to room temperature, where the spin signal is weaker. In pump-probe experiments, which optically inject and detect spins, the sensitivity is often improved by using a photoelastic modulator (PEM) for lock-in detection. However, spurious signals can arise if diode lasers are used as optical sources in such experiments, along with a PEM. In this work, we eliminated the spurious electromagnetic coupling of the PEM onto the probe diode laser, by the double modulation technique. We also developed a test for spurious modulated interference in the pump-probe signal, due to the PEM. Besides, an order of magnitude enhancement in the sensitivity of detection of spin polarization by Kerr rotation, to 3x10(-8) rad was obtained by using the concept of Allan variance to optimally average the time series data over a period of 416 s. With these improvements, we are able to experimentally demonstrate at room temperature, photoinduced steady-state spin polarization in bulk GaAs. Thus, the advances reported here facilitate the use of diode lasers with a PEM for sensitive pump-probe experiments. They also constitute a step toward detection of spin-injection in Si at room temperature.
Resumo:
A brief overview of optical monitoring for vacuum and wet bench film deposition processes is presented. Interferometric and polarimetric measurements are combined with regard to simultaneous real-time monitoring of refractive index and physical thickness. Monitor stability and accuracy are verified with transparent oil standards. This double optical technique is applied to dip coating with a multi-component Zirconyl Chloride aqueous solution, whose time varying refractive index and physical thickness curves indicate significant sensitivity to changes of film flow properties during the process.
Resumo:
Laminar two-dimensional natural convection boundary-layer flow of non-Newtonian fluids along an isothermal horizontal circular cylinder has been studied using a modified power-law viscosity model. In this model, there are no unrealistic limits of zero or infinite viscosity. Therefore, the boundary-layer equations can be solved numerically by using marching order implicit finite difference method with double sweep technique. Numerical results are presented for the case of shear-thinning as well as shear thickening fluids in terms of the fluid velocity and temperature distributions, shear stresses and rate of heat transfer in terms of the local skin-friction and local Nusselt number respectively.
Resumo:
Background Occupational exposures of health care workers occur because of inconsistent compliance with standard precautions. The purpose of this study was to develop national estimates of compliance with standard precautions and occupational exposure reporting among operating room nurses (specifically, scrub nurses) in Australia and to assess variables that influence compliance. Methods A descriptive correlation design was used to investigate relationships between variables and compliance, using a theoretical framework, the Health Belief Model, to give meaning to the variables. Data collection was done through mail-out surveys to members of the Australian College of Operating Room Nurses. Results This article reports the results of compliance with the following 2 specific self-protective behaviors: double-gloving and wearing adequate eye protection. Mean compliance rates were 55.6% with always double-gloving during surgical procedures and 92% with always wearing adequate eye protection. In addition, the variable that had the most influence on compliance was the perception of barriers to compliance, specifically, that adhering to standard precautions interfered with duties. Conclusion These results have implications for the development of multifaceted perioperative infection control programs, including strategies for prevention, education, and policy development, to improve practices aimed at reducing occupational exposures among this high-risk group.
Resumo:
Mixed convection laminar two-dimensional boundary-layer flow of non-Newtonian pseudo-plastic fluids is investigated from a horizontal circular cylinder with uniform surface heat flux using a modified power-law viscosity model, that contains no unrealistic limits of zero or infinite viscosity; consequently, no irremovable singularities are introduced into boundary-layer formulations for such fluids. The governing boundary layer equations are transformed into a non-dimensional form and the resulting nonlinear systems of partial differential equations are solved numerically applying marching order implicit finite difference method with double sweep technique. Numerical results are presented for the case of shear-thinning fluids in terms of the fluid temperature distributions, rate of heat transfer in terms of the local Nusselt number.
Resumo:
The present paper describes a systematic study of argon plasmas in a bell-jar inductively coupled plasma (ICP) source over the range of pressure 5-20 mtorr and power input 0.2-0.5 kW, Experimental measurements as well as results of numerical simulations are presented. The models used in the study include the well-known global balance model (or the global model) as well as a detailed two-dimensional (2-D) fluid model of the system, The global model is able to provide reasonably accurate values for the global electron temperature and plasma density, The 2-D model provides spatial distributions of various plasma parameters that make it possible to compare with data measured in the experiments, The experimental measurements were obtained using a tuned Langmuir double-probe technique to reduce the RF interference and obtain the light versus current (I-V) characteristics of the probe. Time-averaged electron temperature and plasma density were measured for various combinations of pressure and applied RF power, The predictions of the 2-D model were found to be in good qualitative agreement with measured data, It was found that the electron temperature distribution T-e was more or less uniform in the chamber, It was also seen that the electron temperature depends primarily on pressure, but is almost independent of the power input, except in the very low-pressure regime. The plasma density goes up almost linearly with the power input.