966 resultados para Ventilation modules


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Nowadays natural ventilation has gained prominence because its correct use can reduce energy consumption for cooling systems and improve thermal comfort among users. In this paper, we report on the modelling initiative, based on the wind tunnel tests that were carried out for the determination of the influence of natural ventilation in buildings. Indeed, the renewal of air in a closed environment without using an air conditioning system with mechanical elements can lead to energy savings and, in addition, provide air quality.The wind tunnel tests were carried out by varying the positioning of six ventilation modules in the façade system configuration. The modules were positioned below the window-sill (ventilated window-sill) as well as separately above and below the façade. The wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. The results supported the positioning of the six ventilation modules below the window-sill, forming a â ventilated window-sillâ as the most effective natural ventilation solution.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Wind tunnel tests are a reliable tool to determine the effect of natural ventilation on buildings. This paper presents results of wind tunnel tests conducted to evaluate the influence of ventilation modules positioning on a façade system. Modules positioning was modified, resulting in different façade configurations. The tests were carried out with the use of a model, varying the position of the ventilation modules in the façade configuration. The cases tested were six ventilation modules positioned below the window-sill (ventilated window-sill), and three ventilation modules positioned above and below the façade. The façade system proposed was movable and interchangeable so that the same basic model could be used to test the possibilities for ventilation. Wind speed measurements were taken inside and outside the model for the different façades configurations to evaluate the best performance in relation to natural ventilation. Singleâ sided and Cross ventilation were considered for wind speed measurements. Results show the use of six ventilation modules positioned below the window-sill, forming "a ventilated window-sill" is the best solution in terms of natural ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study aimed to describe and compare the ventilation behavior during an incremental test utilizing three mathematical models and to compare the feature of ventilation curve fitted by the best mathematical model between aerobically trained (TR) and untrained ( UT) men. Thirty five subjects underwent a treadmill test with 1 km.h(-1) increases every minute until exhaustion. Ventilation averages of 20 seconds were plotted against time and fitted by: bi-segmental regression model (2SRM); three-segmental regression model (3SRM); and growth exponential model (GEM). Residual sum of squares (RSS) and mean square error (MSE) were calculated for each model. The correlations between peak VO2 (VO2PEAK), peak speed (Speed(PEAK)), ventilatory threshold identified by the best model (VT2SRM) and the first derivative calculated for workloads below (moderate intensity) and above (heavy intensity) VT2SRM were calculated. The RSS and MSE for GEM were significantly higher (p < 0.01) than for 2SRM and 3SRM in pooled data and in UT, but no significant difference was observed among the mathematical models in TR. In the pooled data, the first derivative of moderate intensities showed significant negative correlations with VT2SRM (r = -0.58; p < 0.01) and Speed(PEAK) (r = -0.46; p < 0.05) while the first derivative of heavy intensities showed significant negative correlation with VT2SRM (r = -0.43; p < 0.05). In UT group the first derivative of moderate intensities showed significant negative correlations with VT2SRM (r = -0.65; p < 0.05) and Speed(PEAK) (r = -0.61; p < 0.05), while the first derivative of heavy intensities showed significant negative correlation with VT2SRM (r= -0.73; p < 0.01), Speed(PEAK) (r = -0.73; p < 0.01) and VO2PEAK (r = -0.61; p < 0.05) in TR group. The ventilation behavior during incremental treadmill test tends to show only one threshold. UT subjects showed a slower ventilation increase during moderate intensities while TR subjects showed a slower ventilation increase during heavy intensities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Cancer shows a great diversity in its clinical behavior which cannot be easily predicted using the currently available clinical or pathological markers. The identification of pathways associated with lymph node metastasis (N+) and recurrent head and neck squamous cell carcinoma (HNSCC) may increase our understanding of the complex biology of this disease. Methods: Tumor samples were obtained from untreated HNSCC patients undergoing surgery. Patients were classified according to pathologic lymph node status (positive or negative) or tumor recurrence (recurrent or non-recurrent tumor) after treatment (surgery with neck dissection followed by radiotherapy). Using microarray gene expression, we screened tumor samples according to modules comprised by genes in the same pathway or functional category. Results: The most frequent alterations were the repression of modules in negative lymph node (N0) and in non-recurrent tumors rather than induction of modules in N+ or in recurrent tumors. N0 tumors showed repression of modules that contain cell survival genes and in non-recurrent tumors cell-cell signaling and extracellular region modules were repressed. Conclusions: The repression of modules that contain cell survival genes in N0 tumors reinforces the important role that apoptosis plays in the regulation of metastasis. In addition, because tumor samples used here were not microdissected, tumor gene expression data are represented together with the stroma, which may reveal signaling between the microenvironment and tumor cells. For instance, in non-recurrent tumors, extracellular region module was repressed, indicating that the stroma and tumor cells may have fewer interactions, which disable metastasis development. Finally, the genes highlighted in our analysis can be implicated in more than one pathway or characteristic, suggesting that therapeutic approaches to prevent tumor progression should target more than one gene or pathway, specially apoptosis and interactions between tumor cells and the stroma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irreducible nonzero level modules with finite-dimensional weight spaces are discussed for nontwisted affine Lie superalgebras. A complete classification of such modules is obtained for superalgebras of type A(m, n)(boolean AND) and C(n)(boolean AND) using Mathieu's classification of cuspidal modules over simple Lie algebras. In other cases the classification problem is reduced to the classification of cuspidal modules over finite-dimensional cuspidal Lie superalgebras described by Dimitrov, Mathieu and Penkov. Based on these results a. complete classification of irreducible integrable (in the sense of Kac and Wakimoto) modules is obtained by showing that any such module is of highest weight, in which case the problem was solved by Kac and Wakimoto.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study induced modules of nonzero central charge with arbitrary multiplicities over affine Lie algebras. For a given pseudo parabolic subalgebra P of an affine Lie algebra G, our main result establishes the equivalence between a certain category of P-induced G-modules and the category of weight P-modules with injective action of the central element of G. In particular, the induction functor preserves irreducible modules. If P is a parabolic subalgebra with a finite-dimensional Levi factor then it defines a unique pseudo parabolic subalgebra P(ps), P subset of P(ps). The structure of P-induced modules in this case is fully determined by the structure of P(ps)-induced modules. These results generalize similar reductions in particular cases previously considered by V. Futorny, S. Konig, V. Mazorchuk [Forum Math. 13 (2001), 641-661], B. Cox [Pacific J. Math. 165 (1994), 269-294] and I. Dimitrov, V. Futorny, I. Penkov [Comm. Math. Phys. 250 (2004), 47-63].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pires, FO, Hammond, J, Lima-Silva, AE, Bertuzzi, RCM, and Kiss, MAPDM. Ventilation behavior during upper-body incremental exercise. J Strength Cond Res 25(1): 225-230, 2011-This study tested the ventilation (V(E)) behavior during upper-body incremental exercise by mathematical models that calculate 1 or 2 thresholds and compared the thresholds identified by mathematical models with V-slope, ventilatory equivalent for oxygen uptake (V(E)/(V) over dotO(2)), and ventilatory equivalent for carbon dioxide uptake (V(E)/(V) over dotCO(2)). Fourteen rock climbers underwent an upper-body incremental test on a cycle ergometer with increases of approximately 20 W.min(-1) until exhaustion at a cranking frequency of approximately 90 rpm. The V(E) data were smoothed to 10-second averages for V(E) time plotting. The bisegmental and the 3-segmental linear regression models were calculated from 1 or 2 intercepts that best shared the V(E) curve in 2 or 3 linear segments. The ventilatory threshold(s) was determined mathematically by the intercept(s) obtained by bisegmental and 3-segmental models, by V-slope model, or visually by V(E)/(V) over dotO(2) and V(E)/(V) over dotCO(2). There was no difference between bisegmental (mean square error [MSE] = 35.3 +/- 32.7 l.min(-1)) and 3-segmental (MSE = 44.9 +/- 47.8 l.min(-1)) models in fitted data. There was no difference between ventilatory threshold identified by the bisegmental (28.2 +/- 6.8 ml.kg(-1).min(-1)) and second ventilatory threshold identified by the 3-segmental (30.0 +/- 5.1 ml.kg(-1).min(-1)), V(E)/(V) over dotO(2) (28.8 +/- 5.5 ml.kg(-1).min(-1)), or V-slope (28.5 +/- 5.6 ml.kg(-1).min(-1)). However, the first ventilatory threshold identified by 3-segmental (23.1 +/- 4.9 ml.kg(-1).min(-1)) or by VE/(V) over dotO(2) (24.9 +/- 4.4 ml.kg(-1).min(-1)) was different from these 4. The V(E) behavior during upper-body exercise tends to show only 1 ventilatory threshold. These findings have practical implications because this point is frequently used for aerobic training prescription in healthy subjects, athletes, and in elderly or diseased populations. The ventilatory threshold identified by V(E) curve should be used for aerobic training prescription in healthy subjects and athletes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many factors affect the airflow patterns, thermal comfort, contaminant removal efficiency and indoor air quality at individual workstations in office buildings. In this study, four ventilation systems were used in a test chamber designed to represent an area of a typical office building floor and reproduce the real characteristics of a modern office space. Measurements of particle concentration and thermal parameters (temperature and velocity) were carried out for each of the following types of ventilation systems: (a) conventional air distribution system with ceiling supply and return; (b) conventional air distribution system with ceiling supply and return near the floor; (c) underfloor air distribution system; and (d) split system. The measurements aimed to analyse the particle removal efficiency in the breathing zone and the impact of particle concentration on an individual at the workstation. The efficiency of the ventilation system was analysed by measuring particle size and concentration, ventilation effectiveness and the indoor/outdoor ratio. Each ventilation system showed different airflow patterns and the efficiency of each ventilation system in the removal of the particles in the breathing zone showed no correlation with particle size and the various methods of analyses used. (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ligand-binding domain of the low-density lipoprotein (LDL) receptor is comprised of seven tandemly repeated ligand-binding modules, each being approximately 40 amino acids long and containing six conserved cysteine residues. We have expressed and characterized a concatemer of the first two modules (LB1 and LB2) of the human LDL receptor. Oxidative folding of the recombinant concatemer (rLB(1-2)), in the presence of calcium ions, gave a single dominant isomer with six disulfide bonds. Peptic cleavage of the short Linker region that connects the last cysteine residue of LB1 and the first cysteine residue of LB2 yielded two discrete fragments, thus excluding the presence of intermodule disulfide bonds. The N-terminal module, LB1, reacted with a conformation-specific monoclonal antibody (IgG-C7) made to LB1 in the native LDL receptor. From this, we concluded that the first module was correctly folded, with the same set of disulfide bonds as LB1 of the LDL receptor. The disulfide bond connections of LB2 were identified from mass spectral analysis of fragments formed by digestion of the C-terminal peptic fragment with elastase. These data showed that the disulfide bonds of LB2 connected Cys(I) and Cys(III), Cys(II) and Cys(V), and Cys(IV) and Cys(VI). This pattern is identical to that found for recombinant LB1 and LB2. The concatemer has two high-affinity calcium-binding sites, one per module. An analysis of the secondary chemical shifts of C alpha protons shows that the conformations of LB1 and LB2 in the concatemer are very similar to those of the individual modules, with no evidence for strong interactions between the two modules.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selection of the optimal positive end-expiratory pressure (PEEP) to avoid ventilator-induced lung injury in patients under mechanical ventilation is still a matter of debate. Many methods are available, but none is considered the gold standard. In the previous issue of Critical Care, Zhao and colleagues applied a method based on electrical impedance tomography to help select the PEEP that minimized ventilation inhomogeneities. Though promising when alveolar collapse and overdistension are present, this method might be misleading in patients with normal lungs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Retention of airway secretions is a common and serious problem in ventilated patients. Treating or avoiding secretion retention with mucus thinning, patient-positioning, airway suctioning, or chest or airway vibration or percussion may provide short-term benefit. METHODS: In a series of laboratory experiments with a test-lung system we examined the role of ventilator settings and lung-impedance on secretion retention and expulsion. Known quantities of a synthetic dye-stained mucus simulant with clinically relevant properties were injected into a transparent tube the diameter of an adult trachea and exposed to various mechanical-ventilation conditions. Mucus-simulant movement was measured with a photodensitometric technique and examined with image-analysis software. We tested 2 mucus-simulant viscosities and various peak flows, inspiratory/ expiratory flow ratios, intrinsic positive end-expiratory pressures, ventilation waveforms, and impedance values. RESULTS: Ventilator settings that produced flow bias had a major effect on mucus movement. Expiratory How bias associated with intrinsic positive end-expiratory pressure generated by elevated minute ventilation moved mucus toward the airway opening, whereas intrinsic positive end-expiratory pressure generated by increased airway resistance moved the mucus toward the lungs. Inter-lung transfer of mucus simulant occurred rapidly across the ""carinal divider"" between interconnected test lungs set to radically different compliances; the mucus moved out of the low-compliance lung and into the high-compliance lung. CONCLUSIONS: The movement of mucus simulant was influenced by the ventilation pattern and lung impedance. Flow bias obtained with ventilator settings may clear or embed mucus during mechanical ventilation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to determine whether antenatal corticosteroids improve perinatal adaptation of the pulmonary circulation in lambs with lung hypoplasia (LH). LH was induced in 12 ovine fetuses between 105 and 140 days gestation (term similar to 147 days); in 6 of these the ewe was given a single dose of betamethasone (11.4 mg im) 24 hr before delivery (LH + B). All lambs, including a control group (n = 6), were delivered at similar to 140 days and ventilated for 2 hr during which arterial pressures, pulmonary blood flow (PBF), and ventilating pressure and flow were recorded. During ventilation, respiratory system compliance was lower in both LH + B and LH groups than in controls. Pulmonary vascular resistance (PVR) was lower in LH + B lambs than in LH lambs and similar to controls; PBF was reduced in LH lambs but was restored to control levels by betamethasone. The mean density of small arteries of LH + B lambs was similar to that of LH lambs (P = 0.06) and lower than in controls; the thickness of the media of small pulmonary arteries from LH + B lambs was similar to that in LH lambs and thicker than in controls. VEGF mRNA levels were not different between groups. PDGF mRNA levels in LH + B lambs were higher than in LH lambs; a similar trend (P = 0.06) was seen for PECAM-1. SP-C mRNA levels were greater in both LH and LH + B lambs than in controls. Effects of betamethasone were greater on indices of pulmonary circulation than ventilation. We conclude that a single dose of maternal betamethasone 24 hr prior to birth has significant favorable effects on the postnatal adaptation of the pulmonary circulation in lambs with LH.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: Assess the effect of re-expansive respiratory patterns associated to respiratory biofeedback (RBF) on pulmonary function, respiratory muscle strength and habits in individuals with functional mouth breathing (FMB). Methods: Sixty children with FMB were divided into experimental and control groups. The experimental group was submitted to 15 sessions of re-expansive respiratory patterns associated to RBF (biofeedback pletsmovent; MICROHARD (R) V1.0), which provided biofeedback of the thoracic and abdominal movements. The control group was submitted to 15 sessions using biofeedback alone. Spirometry, maximum static respiratory pressure measurements and questions regarding habits (answered by parents/guardians) were carried out before and after therapy. The Student`s t-test for paired data and non-parametric tests were employed for statistical analysis at a 5% Level of significance. Results: Significant changes were found in forced vital. capacity, Tiffeneau index scores, maximum expiratory pressure, maximum inspiratory pressure and habits assessed in FMB with the use of RBF associated to the re-expansive patterns. No significant differences were found comparing the experimental and control groups. Conclusions: The results allow the conclusion that RBF associated to re-expansive patterns improves forced vital capacity, Tiffeneau index scores, respiratory muscle strength and habits in FMB and can therefore be used as a form of therapy for such individuals. (C) 2008 Elsevier Ireland Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Patients with idiopathic pulmonary fibrosis (IPF) present an important ventilatory (imitation reducing their exercise capacity. Non-invasive ventilatory support has been shown to improve exercise capacity in patients with obstructive diseases; however, its effect on IPF patients remains unknown. Objective: The present study assessed the effect of ventilatory support using proportional, assist ventilation (PAV) on exercise capacity in patients with IPF. Methods: Ten patients (61.2 +/- 9.2 year-old) were submitted to a cardiopulmonary exercise testing, plethysmography and three submaximal. exercise tests (60% of maximum load): without ventilatory support, with continuous positive airway pressure (CPAP) and PAV. Submaximal tests were performed randomly and exercise capacity, cardiovascular and ventilatory response as well as breathlessness subjective perception were evaluated. Lactate plasmatic levels were obtained before and after submaximal. exercise. Results: Our data show that patients presented a limited exercise capacity (9.7 +/- 3.8 mL O(2)/kg/min). Submaximal. test was increased in patients with PAV compared with CPAP and without ventilatory support (respectively, 11.1 +/- 8.8 min, 5.6 +/- 4.7 and 4.5 +/- 3.8 min; p < 0.05). An improved arterial oxygenation and lower subjective perception to effort was also observed in patients with IPF when exercise was performed with PAV (p < 0.05). IPF patients performing submaximal exercise with PAV also presented a lower heart rate during exercise, although systolic and diastolic pressures were not different among submaximal tests. Our results suggest that PAV can increase exercise tolerance and decrease dyspnoea and cardiac effort in patients with idiopathic pulmonary fibrosis. (C) 2009 Elsevier Ltd. All rights reserved.