967 resultados para Right-heart Catheterization


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Recent studies have recognised the importance of pulmonary hypertension (PH) in sickle cell disease (SCD). The aim of this study was to determine the prevalence and prognostic impact of PH and its features in patients with SCD. 80 patients with SCD underwent baseline clinical evaluation, laboratory testing, 6-min walk tests (6MWTs) and echocardiography. Patients with a peak tricuspid regurgitant jet velocity (TRV) of >= 2.5 m.s(-1) were further evaluated through right heart catheterisation (RHC) to assure the diagnosis of PH. Our study evidenced a 40% prevalence of patients with elevated TRV at echocardiography. RHC (performed in 25 out of 32 patients) confirmed PH in 10% (95% CI 3.4-16.5%) of all patients, with a prevalence of post-capillary PH of 6.25% (95% CI 0.95-11.55%) and pre-capillary PH of 3.75% (95% CI -0.4-7.9%). Patients with PH were older, had worse performance in 6MWTs, and more pronounced anaemia, haemolysis and renal dysfunction. Survival was shorter in patients with PH. Our study reinforced the use of echocardiography as a screening tool for PH in SCD and the mandatory role of RHC for proper diagnosis. Our findings confirmed the prognostic significance of PH in SCD as its association to pronounced haemolytic profile.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Microscopic pulmonary tumor embolism (MPTE) is an uncommon cause of dyspnea in patients with cancer and one of the most difficult to diagnose. MPTE is a syndrome that is pathologically characterized by the occlusion of small pulmonary arteries and arterioles by aggregates of tumor cells. Because the clinical picture resembles that of thromboembolic disease, it is rarely recognized before death. The most common clinical symptom is subacute progressive dyspnea over weeks to months. We recently observed a case of MPTE of exceptional interest as the patient was under aggressive anticoagulant treatment and developed fulminant pulmonary hypertension with fatal right heart failure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Two asylum seekers (patient A, 30 year old man from Mongolia; patient B, 18 year old woman from the Sudan) were referred to our outpatient clinic because of acute and chronic deterioration of their general condition and shortness of breath. Both patients presented with a clear clinical picture of systemic venous hypertension and moderate pulmonary congestion. Patient B had a paradoxical pulse compatible to cardiac tamponade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción: A los pacientes con Insuficiencia Cardíaca (IC) estadio D candidatos a trasplante cardiaco se les realiza la determinación de las presiones de la arteria pulmonar por CCD considerada como prueba de oro. Se decidió conocer si la medición de las presión de la arteria pulmonar obtenidas por ECO TT tenían concordancia con las obtenidas por el CCDen estos paciente que fueron evaluados para trasplante cardiaco. Metodología: Se realizó una recolección retrospectiva de los datos consignados en las historias clínicas de todos los pacientes que fueron receptores de un trasplante cardiaco en la FCI-IC desde septiembre del 2005 hasta Mayo del 2013 y se determinó la concordancia entre la presión sistólica pulmonar evaluado por ECO TT y CCD. Resultados: Se incluyeron 46 pacientes. El 76,1% son hombres y con edad promedio de 46,4 ± 13,1. La PSAP estimada por CCD fue 48,3 ± 13,1 mmHg Vs 45,1 ± 12,1 mmHg por ECO TT. La fracción de eyección fue 15,1 ± 4,06% (IC: 13,95-16,36). El 75,9% de los pacientes tenían HTP moderada y severa. La concordancia entre la PSAP determinada por ambos métodos fue 0,475 (I,C: 0.256 - 0.694), y el coeficiente de correlación intraclase fue de 0,090, indicando una baja concordancia entre los dos métodos. Discusión: La determinación de las presiones pulmonares determinada por ECO TT tiene mala concordancia con las obtenidas por CCD. No se debe usar este estudio para excluir los pacientes candidatos a trasplante cardiaco ni para evaluar las variaciones de las misma en la evolución de la enfermedad.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

El compromiso del sistema cardiovascular es frecuente en los pacientes en estado crítico, por tanto la monitorización hemodinámica es esencial para un tratamiento apropiado dirigido a objetivos terapéuticos en este grupo de pacientes. La monitorización hemodinámica del gasto cardíaco y la estimación del volumen intravascular son fundamentales para el manejo de los pacientes pediátricos en estado crítico, la medición del gasto cardíaco es uno de los principales elementos para evaluar la situación hemodinámica y la perfusión tisular de un paciente ayudando a dirigir el tratamiento y a monitorizar la respuesta clínica en pacientes con choque séptico. La hipovolemia es una causa común para la falla circulatoria en pacientes en condición crítica, el encontrar un método confiable para medición de precarga es importante para guiar la administración de líquidos. Tradicionalmente se han utilizado medidas de la volemia asociadas como la presión venosa central (PVC), frecuencia cardiaca (FC), presión arterial (PA) y el gasto urinario. Estos indicadores tienen grandes factores de distracción que hacen que su valor sea limitado y por tanto se tengan que buscar alternativas más confiables. En años recientes se han postulado parámetros dinámicos para la evaluación de la precarga, entre ellos uno de los mas ampliamente estudiado es la medición de la variabilidad de Volumen sistólico (VVS); Este valor se basa en el concepto de que durante la inspiración, la disminución del retorno venoso produce una disminución del Volumen sistólico, lo cual se manifiesta como una disminución en la onda de pulso; Por tanto en una situación de hipovolemia esta diferencia será mayor, dado que será más evidente la disminución del volumen al final de la diástole. En adultos este parámetro se ha convertido en una herramienta útil para evaluar estado de volumen de los pacientes que se encuentran en estado crítico y ha demostrado su utilidad para predecir respuesta a administración de fluidos en diferentes poblaciones de pacientes. En la actualidad no hay estudios en niños que comparen la medición de VVS contra dichas medidas tradicionales de volemia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introducción. El cateterismo cardiaco derecho representa el estándar de referencia para el diagnóstico de hipertensión pulmonar, sin embargo el rendimiento de la ecocardiografía como estudio inicial ha mostrado buena correlación con las variables medidas por cateterismo. El presente estudio pretende describir el grado de correlación y concordancia entre la ecocardiografía y el cateterismo cardiaco derecho para la medición de la presión sistólica de la arteria pulmonar. Materiales y métodos. Se realizó un estudio observacional retrospectivo de los pacientes sometidos a cateterismo cardiaco derecho entre los años 2009 a 2014 y se compararon con los datos de ecocardiograma más cercano a este cateterismo, teniendo en cuenta la presión sistólica de la arteria pulmonar (PSAP) en las dos modalidades diagnósticas mediante correlación y concordancia estadística según los coeficientes de Pearson y el índice de Lin respectivamente. Resultados. Se recolectaron un total de 169 pacientes con un índice de correlación (r) obtenido para la medición de PSAP del total de la muestra de 0.73 p < 0.0001 mostrando un grado de correlación alto para toda la muestra evaluada. El análisis de concordancia obtenido para toda la población a partir del índice de Lin fue de 0.71 lo que determinó una pobre concordancia. Discusión. Se encontró buena correlación entre ecocardiografía y cateterismo cardiaco derecho para la medición de la PSAP, sin embargo la concordancia entre los métodos diagnósticos es pobre, por tanto el ecocardiograma no reemplaza al cateterismo cardiaco derecho como estudio de elección para diagnóstico y seguimiento de pacientes con hipertensión pulmonar.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Clinical studies evaluating the use of phenylephrine in septic shock are lacking. The present study was designed as a prospective, crossover pilot study to compare the effects of norepinephrine (NE) and phenylephrine on systemic and regional hemodynamics in patients with catecholamine-dependent septic shock. In 15 septic shock patients, NE (0.82 +/- 0.69 mug.kg.min) was replaced with phenylephrine (4.39 +/- 5.23 mug.kg.min) titrated to maintain MAP between 65 and 75 mmHg. After 8 h of phenylephrine infusion treatment was switched back to NE. Data from right heart catheterization, acid-base balance, thermo-dye dilution catheter, gastric tonometry, and renal function were obtained before, during, and after replacing NE with phenylephrine. Variables of systemic hemodynamics, global oxygen transport, and acid-base balance remained unchanged after replacing NE with phenylephrine except for a significant decrease in heart rate (phenylephrine, 89 +/- 18 vs. NE, 93 +/- 18 bpm; P < 0.05). However, plasma disappearance rate (phenylephrine, 13.5 +/- 7.1 vs. NE, 16.4 +/- 8.7%.min) and clearance of indocyanine green (phenylephrine, 330 +/- 197 vs. NE, 380 +/- 227mL.min.m), as well as creatinine clearance (phenylephrine, 81.3 +/- 78.4 vs. NE, 94.3 +/- 93.5 mL.min) were significantly decreased by phenylephrine infusion (each P < 0.05). In addition, phenylephrine increased arterial lactate concentrations as compared with NE infusion (1.7 +/- 1.0 vs. 1.4 +/- 1.1 mM; P < 0.05). After switching back to NE, all variables returned to values obtained before phenylephrine infusion except creatinine clearance and gastric tonometry values. Our results suggest that for the same MAP, phenylephrine causes a more pronounced hepatosplanchnic vasoconstriction as compared with NE.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Pulmonary hypertension (PH) frequently coexists with severe aortic stenosis, and PH severity has been shown to predict outcomes after transcatheter aortic valve implantation (TAVI). The effect of PH hemodynamic presentation on clinical outcomes after TAVI is unknown. METHODS AND RESULTS Of 606 consecutive patients undergoing TAVI, 433 (71.4%) patients with severe aortic stenosis and a preprocedural right heart catheterization were assessed. Patients were dichotomized according to whether PH was present (mean pulmonary artery pressure, ≥25 mm Hg; n=325) or not (n=108). Patients with PH were further dichotomized by left ventricular end-diastolic pressure into postcapillary (left ventricular end-diastolic pressure, >15 mm Hg; n=269) and precapillary groups (left ventricular end-diastolic pressure, ≤15 mm Hg; n=56). Finally, patients with postcapillary PH were divided into isolated (n=220) and combined (n=49) subgroups according to whether the diastolic pressure difference (diastolic pulmonary artery pressure-left ventricular end-diastolic pressure) was normal (<7 mm Hg) or elevated (≥7 mm Hg). Primary end point was mortality at 1 year. PH was present in 325 of 433 (75%) patients and was predominantly postcapillary (n=269/325; 82%). Compared with baseline, systolic pulmonary artery pressure immediately improved after TAVI in patients with postcapillary combined (57.8±14.1 versus 50.4±17.3 mm Hg; P=0.015) but not in those with precapillary (49.0±12.6 versus 51.6±14.3; P=0.36). When compared with no PH, a higher 1-year mortality rate was observed in both precapillary (hazard ratio, 2.30; 95% confidence interval, 1.02-5.22; P=0.046) and combined (hazard ratio, 3.15; 95% confidence interval, 1.43-6.93; P=0.004) but not isolated PH patients (P=0.11). After adjustment, combined PH remained a strong predictor of 1-year mortality after TAVI (hazard ratio, 3.28; P=0.005). CONCLUSIONS Invasive stratification of PH according to hemodynamic presentation predicts acute response to treatment and 1-year mortality after TAVI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives The study sought to evaluate the ability of cardiac magnetic resonance (CMR) to monitor acute and long-term changes in pulmonary vascular resistance (PVR) noninvasively. Background PVR monitoring during the follow-up of patients with pulmonary hypertension (PH) and the response to vasodilator testing require invasive right heart catheterization. Methods An experimental study in pigs was designed to evaluate the ability of CMR to monitor: 1) an acute increase in PVR generated by acute pulmonary embolization (n = 10); 2) serial changes in PVR in chronic PH (n = 22); and 3) changes in PVR during vasodilator testing in chronic PH (n = 10). CMR studies were performed with simultaneous hemodynamic assessment using a CMR-compatible Swan-Ganz catheter. Average flow velocity in the main pulmonary artery (PA) was quantified with phase contrast imaging. Pearson correlation and mixed model analysis were used to correlate changes in PVR with changes in CMR-quantified PA velocity. Additionally, PVR was estimated from CMR data (PA velocity and right ventricular ejection fraction) using a formula previously validated. Results Changes in PA velocity strongly and inversely correlated with acute increases in PVR induced by pulmonary embolization (r = –0.92), serial PVR fluctuations in chronic PH (r = –0.89), and acute reductions during vasodilator testing (r = –0.89, p ≤ 0.01 for all). CMR-estimated PVR showed adequate agreement with invasive PVR (mean bias –1.1 Wood units,; 95% confidence interval: –5.9 to 3.7) and changes in both indices correlated strongly (r = 0.86, p < 0.01). Conclusions CMR allows for noninvasive monitoring of acute and chronic changes in PVR in PH. This capability may be valuable in the evaluation and follow-up of patients with PH.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Trabalho Final do Curso de Mestrado Integrado em Medicina, Faculdade de Medicina, Universidade de Lisboa, 2014

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In 2003 there was an increase in the use of pulmonary artery catheters in Australia from 12, 000 to 16, 000 units in intensive care and peri-operative care. This survey of intensive care nurses in five intensive care units in Queensland addressed knowledge of use, safety and complications of the pulmonary artery catheter, using a previously validated 31 question multiple choice survey. One hundred and thirty-nine questionnaires were completed, a response rate of 46%. The mean score was 13.3, standard deviation +/-4.2 out of a total of 31 (42.8% correct). The range was 4 to 25. Scores were significantly higher in those participants with more ICU experience, higher nursing grade, a higher self-assessed level of knowledge and greater frequency of PAC supervision. There was no significant correlation between total score and hospital- or university-based education, or total score and public or private hospital participants. Fifty-one per cent were unable to correctly identify the significant pressure change as the catheter is advanced from the right ventricle to the pulmonary artery.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Early detection of right ventricular (RV) involvement in chronic pulmonary hypertension (PH) is essential due to prognostic implications. T1 mapping by cardiac magnetic resonance (CMR) has emerged as a noninvasive technique for extracellular volume fraction (ECV) quantification. We assessed the association of myocardial native T1 time and equilibrium contrast ECV (Eq-ECV) at the RV insertion points with pulmonary hemodynamics and RV performance in an experimental model of chronic PH. Right heart catheterization followed by immediate CMR was performed on 38 pigs with chronic PH (generated by surgical pulmonary vein banding) and 6 sham-operated controls. Native T1 and Eq-ECV values at the RV insertion points were both significantly higher in banded animals than in controls and showed significant correlation with pulmonary hemodynamics, RV arterial coupling, and RV performance. Eq-ECV values also increased before overt RV systolic dysfunction, offering potential for the early detection of myocardial involvement in chronic PH.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The results of a recent study have shown that there is a severe shortage of donor hearts to meet the demand of patients suffering from acute heart failures, and patients who received a left ventricular assist device (LVAD) have extended lives. However, some of them develop right heart failure syndrome, and these patients required a right ventricular assist device (RVAD). Hence, current research focus is in the development of a bi-ventricular assist device (Bi-VAD). Computational Fluid Dynamics (CFD) is useful for estimating blood damage for design of a Bi-VAD centrifugal heart pump to meet the demand of the left and right ventricles of a normal hearts with a flow rate of 5 lit/min and the supply pressure of 100 mmHg for the left ventricle and 20 mmHg for the right ventricle. Numerical studies have been conducted to predict pressure, flow rate, the velocity profiles, and streamlines in a continuous flow Bi-VAD using. Based on the predictions of numerical simulations, only few flow regions in the Bi-VAD exhibited signs of velocity profiles and stagnation points, thereby signifying potentially low levels of thrombogenesis.