901 resultados para Reagent Strips


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In Nigeria, schistosomiasis, caused predominantly by the species Schistosoma haematobium, is highly endemic in resource-poor communities. We performed a school-based survey in two rural communities in Osun State (Southwestern Nigeria) and assessed macrohaematuria, microhaematuria and proteinuria as indirect indicators for the presence of disease. Urine samples were inspected macroscopically for haematuria and screened for microhaematuria and proteinuria using urine reagent strips. The microscopic examination of schistosome eggs was used as the gold standard for diagnosis. In total, 447 schoolchildren were included in this study and had a 51% prevalence of urinary schistosomiasis. The sensitivity of microhaematuria (68%) and proteinuria (53%) for infection with S. haematobium was relatively low. In patients with a heavy infection (>500 eggs/10 mL), the sensitivity of microhaematuria was high (95%). When the presence of macrohaematuria and the concomitant presence of microhaematuria and proteinuria were combined, it revealed a sensitivity of 63%, a specificity of 93% and a positive predictive value of 91%. Macrohaematuria also showed high specificity (96%) and a positive predictive value of 92%, while sensitivity was < 50%. These data show that combining urine reagent strip tests (presence of proteinuria and microhaematuria) and information on macrohaematuria increased the accuracy of the rapid diagnosis of urinary schistosomiasis in an endemic rural West African setting. This simple approach can be used to increase the quality of monitoring of schistosomiasis in schoolchildren.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific gravity of urine (SG) indicates the number and weight of solute particles in urine; its measurement is helpful in interpreting proteinuria detected by dipstick tests and in monitoring adequate hydration in patients with nephrolithiasis. Four methods for measuring SG or osmolality of urine are currently available (depression of the freezing-point, urometry, refractometry, cation exchange on a reagent strip). Using a recently developed reagent strip, we have measured SG in morning urines of 340 non-selected outpatients and compared the results with SG measurements by refractometry of the same urines. In 86.2% of all urines, a good positive correlation between SG measured by reagent strip and refractometry was noted (r = 0.913, p = 0.0001). In 13.8% of the urines, however, the SG measured by reagent strip deviated by more than +/- 5 from the value obtained by refractometry; in 90% of these urines, glucosuria (reagent strip values too low or too high), proteinuria (values too high), or bacteriuria/leukocyturia (values too low or too high) could be found. In alkaline urine (pH > 7.0), SG values obtained by reagent strip have to be corrected by +5.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The objective of this work was to evaluate hematological, biochemical and ruminant parameters for diagnosis and treatment of the left displaced abomasum (LDA) in dairy cows, in the Plateau Region of Rio Grande do Sul, Brazil. Ruminant fluid, blood and urine samples were collected from 20 cows suffering LDA and from 20 healthy cows (control). The cows with LDA showed lower values of daily milk production, body weight and corporal condition score. The use of pH reagent strips showed to be functional in the field, when compared to a digital pH meter. Ruminant dynamics was damaged in cows affected by LDA, as it was evidenced by the higher reduction time of methylene blue. Serum values of lactate, beta-hydroxybutyrate, urea, albumin, free fatty acids and cholesterol shows to be auxiliary tools in the LDA characterization.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Context: Accurately determining hydration status is a preventative measure for exertional heat illnesses (EHI). Objective: To determine the validity of various field measures of urine specific gravity (Usg) compared to laboratory instruments. Design: Observational research design to compare measures of hydration status: urine reagent strips (URS) and a urine color (Ucol) chart to a refractometer. Setting: We utilized the athletic training room of a Division I-A collegiate American football team. Participants: Trial 1 involved urine samples of 69 veteran football players (age=20.1+1.2yr; body mass=229.7+44.4lb; height=72.2+2.1in). Trial 2 involved samples from 5 football players (age=20.4+0.5yr; body mass=261.4+39.2lb; height=72.3+2.3in). Interventions: We administered the Heat Illness Index Score (HIIS) Risk Assessment, to identify athletes at-risk for EHI (Trial 1). For individuals “at-risk” (Trial 2), we collected urine samples before and after 15 days of pre-season “two-a-day” practices in a hot, humid environment(mean on-field WBGT=28.84+2.36oC). Main Outcome Measures: Urine samples were immediately analyzed for Usg using a refractometer, Diascreen 7® (URS1), Multistix® (URS2), and Chemstrip10® (URS3). Ucol was measured using Ucol chart. We calculated descriptive statistics for all main measures; Pearson correlations to assess relationships between the refractometer, each URS, and Ucol, and transformed Ucol data to Z-scores for comparison to the refractometer. Results: In Trial 1, we found a moderate relationship (r=0.491, p<.01) between URS1 (1.020+0.006μg) and the refractometer (1.026+0.010μg). In Trial 2, we found marked relationships for Ucol (5.6+1.6shades, r=0.619, p<0.01), URS2 (1.019+0.008μg, r=0.712, p<0.01), and URS3 (1.022+0.007μg, r=0.689, p<0.01) compared to the refractometer (1.028+0.008μg). Conclusions: Our findings suggest that URS were inconsistent between manufacturers, suggesting practitioners use the clinical refractometer to accurately determine Usg and monitor hydration status.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reduction of the natural sesquiterpene lactones furanoheliangolides with Stryker's reagent is an effective process for producing eremantholides through a biomimetic pathway. Other reduction products are also formed. Oxygenated functions at C-15 of the furanoheliangolide produce an increase in the velocities of the reactions and reduce the chemoselectivity of the reagent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A flow system designed with solenoid micro-pumps is introduced for spectrophotometric determination of total tannins based on the Folin- Denis reaction. The procedure minimizes the main drawbacks related to the AOAC batch procedure, i.e. interferences from reducing species in the samples, high reagent consumption and waste generation, and low sampling rate. Linear response was observed for tannic acid concentrations in the range 2-100 mg L-1, with a detection limit (99.7% confidence level) of 0.3 mg L-1. The sampling rate and coefficient of variation (n = 10) were estimated as 75 measurements per hour and 1.1%, respectively. Results of determination of total tannin in tea, beer and wine samples were in agreement with those achieved by the batch reference procedure at the 95% confidence level. In comparison to the batch procedure, the reagent consumption and effluent generation were 83 and 60-fold lower, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The conversion of a furanoheliangolide structure (15-deoxygoyazensolide) into an eremantholide one (eremantholide C) was achieved by tandem hydride conjugate addition-intramolecular carbanion addition using Stryker`s reagent. (c) 2008 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparison of two different standardized reagent procedures for the passive haemagglutination test (PHA) in the detection of specific antibody to Cysticercus cellulosae in cerebrospinal fluid (CSF) was carried out. The formaldehyde-treated group O Rh-human red blood cells (HuRBC) and glutaraldehyde-treated sheep red blood cells (SRBC) were the supplies for the reagents preparation and, in the tests, they were designated as PHA-1 and PHA-2, respectively. For both reagents the cells were coated with the cysticerci total saline extract (TS) antigen. PHA-1 and PHA-2 were assessed in a total of 204 CSF from patients with neurocysticercosis, from non-related infections and from healthy individuals. The positivity and specificity indices obtained were respectively 81.7% and 94.4% for PHA-1 and for PHA-2, 88.7% and 96.6%. Since no significant differences were observed between the results provided by two reagents, at level of significance of 0.05, either processes of cell sensitization can alternatively be used according to the own laboratory convenience.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A hemagglutination (HA) test was standardized using formalin- and tannin-treated gander red blood cells sensitized with a total salt extract of C. cellulosae (HA-Cc) and an antigenic extract of Cysticercus longicollis (HA-Cl) vesicular fluid. A total of 61 cerebrospinal fluid (CSF) samples were assayed, 41 from patients with neurocysticercosis and 20 from a control group, which were, respectively, reactive and non-reactive to ELISA using C. cellulosae. The CSF samples from the control group did not react and 35 (85.4%) and 34 (82.9%) CSF samples from patients were reactive to the HA-Cc and HA-Cl tests, respectively. The reagents ready for use were stable up to 6 months when stored at 4°C in 50% glycerol. The present results confirm that the reagent using Cysticercus longicollis stabilized with glycerol can be used as an alternative in the immunological diagnosis of neurocysticercosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Western blot technique was used to demonstrate the presence of antibodies in the blood of dogs that presented canine visceral leishmaniasis. This technique was used against some specific molecules present in the lysate of the promastigote form of Leshmania chagasi.Through the association of the results of the Western blot technique with the morphological alterations seen as a result of the serum neutralization technique performed in McCoy cells (which mimetizes the macrophage) it was possible to observe the role of some molecules of great relevance in determining the disease in symptomatic dogs as well as that of some other molecules associated with asymptomatic infected dogs that may become transmitters as well as differentiating them as asymptomatic resistant dogs. In the sera analyses carried out during the immunobloting a variation of 9 to 27 immunoreacting bands was observed, which were then compared using Dice's similarity coefficient. In the dendrogram constructed on the basis of the coefficient, 50% similarity was observed among the total number of reagent bands with the promastigote lysate, thus creating five groups. The main difference observed related to the clinical condition of the dogs: symptomatic and asymptomatic dogs were found in separate groups. The asymptomatic group of dogs was distributed in two different places in the dendrogram because they presented two different behavior patterns regarding the cellular morphology in the serum neutralization reaction: the presence or absence of cellular lysis. According to this analysis it is possible to evaluate the immune status and associate it with specific markers observed in the reaction found in the Western blot strips.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interferences with the Olympus immunoturbidimetric assay for ferritin have been reported because the antibodies used in the immunoassay are derived from rabbits. Rabbits are familiar pets known to be a risk factor for developing heterophilic (or interfering) antibodies. This report shows how the current Olympus Ferritin assay has been improved to eliminate the interference from heterophilic antibodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Valuma-aluetason mallisovellus suojakaistojen käytöstä eroosion torjunnassa