503 resultados para REPOSITIONED FLAP


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Periodontal therapy has undergone significant changes in recent decades. While in the past the only goal was to restore gingival health, with no concern about the possible consequences of the disease treatment, currently the procedures are performed in a less invasive manner, to maintain aesthetic periodontal results or even recover them. Gingival recession is an alteration frequently found in patients and may be a complaint for causing various complications. For their treatment, several surgical techniques are reported in the literature. The techniques that are more predictable are those that associate a subepithelial connective tissue graft and a coronally repositioned flap. The original technique consists in performing two vertical incisions for an extensive release of the flap and its stabilization in a coronal position. Although this procedure is extremely widespread in the literature, the search for less invasive surgeries without the use of vertical incisions are the current aim of periodontal plastic surgeries, since they present several advantages. The aim of this paper is to demonstrate a case where adjacent, deep and multiple recessions were present resulting in aesthetic problems, which was resolved by a less invasive approach using a surgical technique in envelope and a subepithelial connective tissue graft.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The aim of this study is to compare the macro- and microsurgery techniques for root coverage using a coronally positioned flap (CPF) associated with enamel matrix derivative (EMD). Methods: Thirty patients were selected for the treatment of localized gingival recessions (GRs) using CPF associated to EMD. Fifteen patients were randomly assigned to the test group (TG), and 15 patients were randomly assigned to the control group (CG). The microsurgical approach was performed in the TG, and the conventional macrosurgical technique was performed in the CG. The clinical parameters evaluated before surgery and after 6 months were GR, probing depth, relative clinical attachment level, width of keratinized tissue (WKT), and thickness of keratinized tissue (TKT). The discomfort evaluation was performed 1 week postoperative. Results: There were no statistically significant differences between groups for all parameters at baseline. At 6 months, there was no statistically significant difference between the techniques in achieving root coverage. The percentage of root coverage was 92% and 83% for TG and CG, respectively. After 6 months, there was a statistically significant increase of WKT and TKT in TG only. Both procedures were well tolerated by all patients. Conclusions: The macro- and microsurgery techniques provided a statistically significant reduction in GR height. After 6 months, there was no statistically significant difference between the techniques regarding root coverage, and the microsurgical technique demonstrated a statistically significant increase in WKT and TKT. J Periodontol 2010;81:1572-1579.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Aim This randomized, controlled, clinical study compared two surgical techniques for root coverage with the acellular dermal matrix graft (ADMG) to evaluate which procedure could provide better root coverage and greater amounts of keratinized tissue. Materials and Methods Fifteen pairs of bilateral Miller Class I or II gingival recessions were treated and assigned randomly to the test group, and the contra-lateral recessions were assigned to the control group. The ADMG was used in both groups. In the control group, the graft and flap were positioned at the level of the cemento-enamel junction (CEJ), and in the test group, the graft was positioned 1 mm apical to the CEJ and the flap 1 mm coronal to the CEJ. The clinical parameters were taken before the surgeries and after 6 months. The gingival recession area, a new parameter, was measured in standardized photographs through a special device and software. Results There were statistically significant differences favouring the proposed technique for all parameters except for the amount of keratinized tissue at 6 months. Conclusions The proposed test technique is more suitable for root coverage procedures with ADMG, and the new parameter evaluated appears valuable for root coverage analysis. (Clinicaltrials.gov Identifier: NCT01175720).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O sorriso não se baseia apenas em factores dentários relacionados com a cor, a forma ou o alinhamento dos dentes na arcada, mas implica também a presença de tecidos periodontais saudáveis e com um contorno gengival harmónico. Este trabalho tem como objectivo abordar as diversas técnicas de aumento de coroa clínica, enunciar as vantagens e indicações das mesmas, bem como comparar as técnicas cirúrgicas com as ortodônticas. Para tal foi realizada uma pesquisa bibliográfica recorrendo aos motores de busca da Pubmed e b-on, utilizando como palavras-chave: crown lengthening, biological width, crown lengthening AND surgery e crown lengthening AND orthodontic extrusion. Dos 539 artigos encontrados, foram seleccionados 28 que correspondiam aos critérios de inclusão por nós estabelecidos. Critérios de inclusão: meta-análises, ensaios clínicos randomizados e revisões sistemáticas publicadas em Português, Inglês e Espanhol nos últimos 12 anos. De acordo com a literatura, podemos verificar que o aumento de coroa clínica está indicado em várias situações clínicas tais como: cáries infra-gengivais, fracturas radiculares, resolução de alguns problemas estéticos, como o sorriso gengival, principalmente em casos de erupção passiva alterada e assimetrias das margens gengivais. Este aumento pode ser realizado por técnicas cirúrgicas (gengivectomia e retalho de reposicionamento apical), técnicas ortodônticas (extrusão ortodôntica com ou sem fibrotomia) ou através da combinação de ambas.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Introdução: O alongamento coronário é um procedimento que pode envolver, ou não, técnicas cirúrgicas, e que tem como principal objetivo aumentar o tamanho da coroa clínica, assim como devolver a estética, a forma e a função às arcadas dentárias. Este procedimento realiza-se, ou por motivos estéticos ou motivos restauradores. Ultimamente, os motivos estéticos têm vindo a ganhar importância e são eles que, muitas da vezes, levam os pacientes às consultas de medicina dentária. O sorriso gengival é um desses motivos, e pode ser causado, entre outras razões por, uma erupção passiva alterada ou/e um excesso vertical maxilar. Estas são as etiologias que serão descritas neste trabalho. O aumento coronário realiza-se, também, quando há a necessidade de reabilitar um dente, quer seja com resinas compostas ou com coroas. Este, deve sempre respeitar os limites biológicos do periodonto, nomeadamente o espaço biológico. A invasão deste espaço pode por em risco a manutenção da saúde do periodonto e a viabilidade do tratamento a longo prazo, por isto, preconiza-se que deve ser deixado um espaço de 3mm, desde a crista óssea até a margem restauradora. As técnicas de alongamento coronário enumeradas e definidas ao longo desta tese são: a gengivectomia, o retalho apicalmente posicionado e a erupção dentária forçada. Cada uma delas possui as suas indicações e contra-inidcaçoes. A gengivectomia é realizada quando não há necessidade de recontorno ósseo, pelo contrário, quando essa necessidade existe opta-se pelo retalho apicalmente posicionado. A erupção forçada é uma alternativa ao alongamento cirúrgico e aplica-se, normalmente a dentes não restauráveis mas com estrutura dentária sã abaixo do da crista óssea. Um ótimo diagnóstico é o essencial para a escolha da técnica de aumento coronário que melhor se adequa a cada caso. Objetivo: O objetivo desta revisão bibliográfica tem por base a pesquisa das técnicas de alongamento coronário, começando por perceber a anatomia do periodonto, as alterações que nele acontecem antes e depois dos procedimentos de alongamento coronário, a descrição e a comparação dos mesmos. Materiais e métodos: Para a realização desta revisão foram utilizados os principais motores de busca de dados científicos como a PubMed, B-on, Medline, Scielo, Google Académico e ainda o repositório on-line da Universidade Fernando Pessoa. Foram utilizadas as seguintes palavras chaves: “altered passive eruption”, “gingivectomy”, “gingivoplasty”, “apically repositioned flap”, “surgical crown lengthening”, “biologic width”, “mucogengival junction”, “forced eruption”, “prostethic dentistry”, “gummy smile”, resultando num pesquisa de 45 artigos e duas obras literarátias de interesse. Conclusões: Foi possível concluir que existem varias técnicas de alongamento coronário, cada uma adequada a cada caso e verificou-se que existem vários motivos pelo qual se realiza essa técnica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Numerous studies demonstrate the generation and short-term survival of adipose tissue; however, long-term persistence remains elusive. This study evaluates long-term survival and transferability of de novo adipose constructs based on a ligated vascular pedicle and tissue engineering chamber combination. Methods Defined adipose tissue flaps were implanted into rats in either intact or perforated domed chambers. In half of the groups, the chambers were removed after 10 weeks and the constructs transferred on their vascular pedicle to a new site, where they were observed for a further 10 weeks. In the remaining groups, the tissue construct was observed for 20 weeks inside the chamber. Tissue volume was assessed using magnetic resonance imaging and histologic measures, and constructs were assessed for stability and necrosis. Sections were assessed histologically and for proliferation using Ki-67. Results At 20 weeks, volume analysis revealed an increase in adipose volume from 0.04 ± 0.001 ml at the time of insertion into the chambers to 0.27 ± 0.004 ml in the closed and 0.44 ± 0.014 ml in the perforated chambers. There was an additional increase of approximately 10 to 15 percent in tissue volume in flaps that remained in chambers for 20 weeks, whereas the volume of the transferred tissue not in chambers remained unaltered. Histomorphometric assessment of the tissues documented no signs of hypertrophy, fat necrosis, or atypical changes of the newly generated tissue. Conclusion This study presents a promising new method of generating significant amounts of mature, vascularized, stable, and transferable adipose tissue for permanent autologous soft-tissue replacement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method of spontaneous generation of new adipose tissue from an existing fat flap is described. A defined volume of fat flap based on the superficial inferior epigastric vascular pedicle in the rat was elevated and inset into a hollow plastic chamber implanted subcutaneously in the groin of the rat. The chamber walls were either perforated or solid and the chambers either contained poly(D,L-lactic-co-glycolic acid) (PLGA) sponge matrix or not. The contents were analyzed after being in situ for 6 weeks. The total volume of the flap tissue in all groups except the control groups, where the flap was not inserted into the chambers, increased significantly, especially in the perforated chambers (0.08 ± 0.007 mL baseline compared to 1.2 ± 0.08 mL in the intact ones). Volume analysis of individual component tissues within the flaps revealed that the adipocyte volume increased and was at a maximum in the chambers without PLGA, where it expanded from 0.04 ± 0.003 mL at insertion to 0.5 ± 0.08 mL (1250% increase) in the perforated chambers and to 0.16 ± 0.03 mL (400% increase) in the intact chambers. Addition of PLGA scaffolds resulted in less fat growth. Histomorphometric analysis rather than simple hypertrophy documented an increased number of adipocytes. The new tissue was highly vascularized and no fat necrosis or atypical changes were observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rotor flap-lag stability in forward flight is studied with and without dynamic inflow feedback via a multiblade coordinate transformation (MCT). The algebra of MCT is found to be so involved that it requires checking the final equations by independent means. Accordingly, an assessment of three derivation methods is given. Numerical results are presented for three- and four-bladed rotors up to an advance ratio of 0.5. While the constant-coefficient approximation under trimmed conditions is satisfactory for low-frequency modes, it is not satisfactory for high-frequency modes or for untrimmed conditions. The advantages of multiblade coordinates are pronounced when the blades are coupled by dynamic inflow.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breast reconstruction is performed for 10-15 % of women operated on for breast cancer. A popular method is the TRAM (transverse rectus abdominis musculocutaneous) flap formed of the patient’s own abdominal tissue, a part of one of the rectus abdominis muscles and a transverse skin-subcutis area over it. The flap can be raised as a pedicled or a free flap. The pedicled TRAM flap, based on its nondominant pedicle superior epigastric artery (SEA), is rotated to the chest so that blood flow through SEA continues. The free TRAM flap, based on its dominant pedicle deep inferior epigastric artery (DIEA), is detached from the abdomen, transferred to the chest, and DIEA and vein are anastomosed to vessels on the chest. Cutaneous necrosis is seen in 5–60 % of pedicled TRAM flaps and in 0–15 % of free TRAM flaps. This study was the first one to show with blood flow measurements that the cutaneous blood flow is more generous in free than in pedicled TRAM flaps. After this study the free TRAM flap has exceeded the pedicled flap in popularity as a breast reconstruction method, although the free flap it is technically a more demanding procedure than the pedicled TRAM flap. In pedicled flaps, a decrease in cutaneous blood flow was observed when DIEA was ligated. It seems that SEA cannot provide sufficient blood flow on the first postoperative days. The postoperative cutaneous blood flow in free TRAM flaps was more stable than in pedicled flaps. Development of cutaneous necrosis of pedicled TRAM flaps could be predicted based on intraoperative laser Doppler flowmetry (LDF) measurements. The LDF value on the contralateral skin of the flap decreased to 43 ± 7 % of the initial value after ligation of the DIEA in flaps developing cutaneous necrosis during the next week. Endothelin-1 (ET-1) is a powerful vasoconstrictory peptide secreted by vascular endothelial cells. A correlation was found between plasma ET-1 concentrations and peripheral vasoconstriction developing during and after breast reconstructions with a pedicled TRAM flap. ET-1 was not associated with the development of cutaneous necrosis. Felodipine, a vasodilating calcium channel antagonist, had no effect on plasma ET-1 concentrations, peripheral vasoconstriction or development of cutaneous necrosis in free TRAM flaps. Body mass index and thickness of abdominal were not associated with cutaneous necrosis in pedicled TRAM flaps.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oral cancer ranks among the 10 most common cancers worldwide. Since it is commonly diagnosed at locally advanced stage, curing the cancer demands extensive tissue resection. The emergent defect is reconstructed generally with a free flap transfer. Repair of the upper aerodigestive track with maintenance of its multiform activities is challenging. The aim of the study was to extract comprehensive treatment outcomes for patients having undergone microvascular free flap transfer because of large oral cavity or pharyngeal cancer. Ninety-four patients were analyzed for postoperative survival and complications. Forty-four patients were followed-up and analyzed for functional outcome, which was determined in terms of quality of life, speech, swallowing, and intraoral sensation. Quality of life was assessed using the University of Washington Head and Neck Questionnaire. Speech was analyzed for aerodynamic parameters and for nasal acoustic energy, as well as perceptually for articulatory proficiency, voice quality, and intelligibility. Videofluorography was performed to determine the swallowing ability. Intraoral sensation was measured by moving 2-point discrimination. The 3-year overall survival was over 40%. The 1-year disease-free survival was 43%. Postoperative complications arose in over half of the patients. Flap success rate was high. Perioperative mortality varied between 2% and 11%. Unemployment and heavy drinking were the strongest predictors of survival. Sociodemographic factors were found to associate with quality of life. The global quality of life score deteriorated and did not return to the preoperative level. Significant reduction was detectable in the domains measuring chewing and speech, and in appearance and shoulder function. The basic elements necessary for normal speech were maintained. Speech intelligibility reduced and was related to the misarticulations of the /r/ and /s/ phonemes. Deviant /r/ and /s/ persisted in most patients. Hoarseness and hypernasality occurred infrequently. One year postoperatively, 98% of the patients had achieved oral nutrition and half of them were on a regular masticated diet. Overt and silent aspiration was encountered throughout the follow-up. At 12-month swallow test, 44% of the patients aspirated, 70% of whom silently. Of these patients, 15% presented with pulmonary changes referring to aspiration. Intraoral sensation weakened but was unrelated to oral functions. The results provide new data for oral reconstructions and highlight the importance of the functional outcome of the treatment for an oral cancer patient. The mouth and the pharynx encompass a unit of utmost functional complexity. Surgery should continue to make progress in this area, and methods that lead to good function should be developed. Operational outcome should always be evaluated in terms of function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Prediction of lag damping is difficult owing to the delicate balance of drag, induced drag and Coriolis forces in the in‐plane direction. Moreover, induced drag” is sensitive to dynamic wake, bath shed and trailing components, and thus its prediction requires adequate unsteady‐wake representation. Accordingly, rigid‐blade flap‐lag equations are coupled with a three‐dimensional finite‐state wake model; three isolatcd rotor canfigurations with three, four and five blades are treated over a range of thrust levels, tack numbers, lag frequencies and advance ratios. The investigation includes convergence characteristics of damping with respect to the number of radial shape functions and harmonics of the wake model for multiblade modes of low frequency (< 1/ rev.) to high frequency (> 1/rev.). Predicted flap and lag damping levels are then compared with similar predictions with 1) rigid wake (no unsteady induced now), 2) Loewy lift deficiency and 3) dynamic inflow. The coverage also includes correlations with the measured lag regressive‐mode damping in hover and forward flight and comparisons with similar correlations with dynamic inflow. Lag‐damping predictions with the dynamic wake model are consistently higher than the predictions with the dynamic inflow model; even for the low frequency lag regressive mode, the number of wake harmonics should at least be equal to twice the number of blades.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The contributions of full-wake dynamics in trim analysis are demonstrated for finding the control inputs and periodic responses simultaneously, as well as in Floquet eigenanalysis for finding the damping levels. The equations of flap bending, lag bending, and torsion are coupled with a three-dimensional, finite state wake, and low-frequency (<1/rev) to high frequency (>1/rev) multiblade modes are considered. Full blade-wake dynamics is used in trim analysis and Floquet eigenanalysis. A uniform cantilever blade in trimmed flight is investigated over a range of thrust levels, advance ratios, number of blades, and blade torsional frequencies. The investigation includes the convergence characteristics of control inputs, periodic responses, and damping levels with respect to the number of spatial azimuthal harmonics and radial shape functions in the wake representation. It also includes correlation with the measured lag damping of a three-bladed untrimmed rotor. The parametric study shows the dominant influence of wake dynamics on control inputs, periodic responses, and damping levels, and wake theory generally improves the correlation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Active trailing edge flaps (TEFs) are one of the most promising devices for helicopter vibration reduction. Smart actuators such as the piezoelectric stack actuators (PEAs) are used for TEF actuation. PEAs possess high energy density and have large force in dynamic condition but are limited to small displacements. In this investigation, we study a linear to rotary motion amplification mechanism (AM-2) based on a pinned-pinned post-buckled beam to actuate trailing edge flaps. A linear motion amplification mechanism is developed and coupled with AM-2 to amplify angular flap deflections. Experiments are conducted on bench top-test setup, and maximum flap angle deflections of the order of 12A degrees are achieved in the static case. An aeroelastic analysis is performed and 91 % reduction in helicopter vibration is obtained with multiharmonic control inputs.