985 resultados para Quality indicator


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Despite the progress over recent decades in developing community mental health services internationally, many people still receive treatment and care in institutional settings. Those most likely to reside longest in these facilities have the most complex mental health problems and are at most risk of potential abuses of care and exploitation. This study aimed to develop an international, standardised toolkit to assess the quality of care in longer term hospital and community based mental health units, including the degree to which human rights, social inclusion and autonomy are promoted. METHOD: The domains of care included in the toolkit were identified from a systematic literature review, international expert Delphi exercise, and review of care standards in ten European countries. The draft toolkit comprised 154 questions for unit managers. Inter-rater reliability was tested in 202 units across ten countries at different stages of deinstitutionalisation and development of community mental health services. Exploratory factor analysis was used to corroborate the allocation of items to domains. Feedback from those using the toolkit was collected about its usefulness and ease of completion. RESULTS: The toolkit had excellent inter-rater reliability and few items with narrow spread of response. Unit managers found the content highly relevant and were able to complete it in around 90 minutes. Minimal refinement was required and the final version comprised 145 questions assessing seven domains of care. CONCLUSIONS: Triangulation of qualitative and quantitative evidence directed the development of a robust and comprehensive international quality assessment toolkit for units in highly variable socioeconomic and political contexts

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This descriptive study addresses the job satisfaction of nurse managers and clinical nurses working at the Hematology and Hemotherapy Services of a public hospital in Sao Paulo. The study objectives were to identify the factors that caused job satisfaction among nurse managers and clinical nurses, and support the results in the development of indicators to evaluate the quality of nursing human resource management. The components of the study were: autonomy, interaction, professional status, job requirements, organizational norms and remuneration. Participants were 44 nurses. Data were collected using a Job Satisfaction Index (JSI) questionnaire. In conclusion, this study permitted the identification of the clinical nurse group, which was the most satisfied, with a JSI of 10.5; the managerial group scored 10.0. Regarding the satisfaction levels in regards to the current activity, 88.9% of the nurse managers reported feeling satisfied, as did 90.9% of clinical nurses. For both groups, autonomy was the component with the highest level of professional satisfaction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction
Evaluating quality of palliative day services is essential for assessing care across diverse settings, and for monitoring quality improvement approaches.

Aim
To develop a set of quality indicators for assessment of all aspects (structure, process and outcome) of care in palliative day services.

Methods
Using a modified version of the RAND/UCLA appropriateness method (Fitch et al., 2001), a multidisciplinary panel of 16 experts independently completed a survey rating the appropriateness of 182 potential quality indicators previously identified during a systematic evidence review. Panel members then attended a one day, face-to-face meeting where indicators were discussed and subsequently re-rated. Panel members were also asked to rate the feasibility and necessity of measuring each indicator.

Results
71 indicators classified as inappropriate during the survey were removed based on median appropriateness ratings and level of agreement. Following the panel discussions, a further 60 were removed based on appropriateness and feasibility ratings, level of agreement and assessment of necessity. Themes identified during the panel discussion and findings of the evidence review were used to translate the remaining 51 indicators into a final set of 27.

Conclusion
The final indicator set included information on rationale and supporting evidence, methods of assessment, risk adjustment, and recommended performance levels. Further implementation work will test the suitability of this ‘toolkit’ for measurement and benchmarking. The final indicator set provides the basis for standardised assessment of quality across services, including care delivered in community and primary care settings.

Reference

• Fitch K, Bernstein SJ, Aguilar MD, et al. The RAND/UCLA Appropriateness Method User’s Manual. Santa Monica, CA: RAND Corporation; 2001. http://www.rand.org/pubs/monograph_reports/MR1269

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The quest for continuous improvement of the quality of provided care is the objective of nursing care. However, the insertion and permanence of a peripheral venous catheter has been associated to complications, thus making a systematic evaluation of the performance of professionals and the management of health services important. Objective: Analyse complications that caused removal of intravenous catheters. Methods A prospective study with 64 patients of a health service of Portugal, from July to September/2015. Included patients with age 18 years, with a peripheral venous catheter. Descriptive analysis using SPSS. Ethical requirements were met. Results Two hundred three (203) intravenous catheters, in 64 patients, most elderly (section 95.3 %), with mean age of 80 years were evaluated. The catheters remained inserted between one and 12 days (mean 2 days), 66 % of the devices were removed because of complications, such as: removal by the patient (17.7 %), obstruction (17.2 %), infiltration (14.8 %), phlebitis (9.4 %) and fluid exiting the insertion site (6.4 %). The prevalence of obstruction and infiltration per patient was respectively 36 % and 39 %. Conclusions Obstruction and infiltration were the complications of higher prevalence that led to the removal and reinsertion of a new peripheral venous catheter with the possibility of increased pain, infection and hospital costs. Faced with the risk of compromising patient safety and being able to contribute to the improvement of health care, we suggest the inclusion of obstruction and infiltration in the indicators of quality of care, in order to have systematic evaluation of results, (re)plan and implement preventive measures.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Abstract Software product metrics aim at measuring the quality of software. Modu- larity is an essential factor in software quality. In this work, metrics related to modularity and especially cohesion of the modules, are considered. The existing metrics are evaluated, and several new alternatives are proposed. The idea of cohesion of modules is that a module or a class should consist of related parts. The closely related principle of coupling says that the relationships between modules should be minimized. First, internal cohesion metrics are considered. The relations that are internal to classes are shown to be useless for quality measurement. Second, we consider external relationships for cohesion. A detailed analysis using design patterns and refactorings confirms that external cohesion is a better quality indicator than internal. Third, motivated by the successes (and problems) of external cohesion metrics, another kind of metric is proposed that represents the quality of modularity of software. This metric can be applied to refactorings related to classes, resulting in a refactoring suggestion system. To describe the metrics formally, a notation for programs is developed. Because of the recursive nature of programming languages, the properties of programs are most compactly represented using grammars and formal lan- guages. Also the tools that were used for metrics calculation are described.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Several antineoplasic drugs have been demonstrated to be carcinogenic or to have mutagenic and teratogenic effects. The greatest protection is achieved with the implementation of administrative and engineering controls and safety procedures. Objective: to evaluate the improvements on pharmacy technicians' work practices, after the implementation of operational procedures related to individual protection, biologic safety cabinet disinfection and cytotoxic drug preparation. Method: case-study in a hospital pharmacy undergoing a certification process. Six pharmacy technicians were observed during their daily activities. Characterization of the work practices was made using a checklist based on ISOPP and PIC guidelines. The variables studied concerning cleaning/disinfection procedures, personal protective equipment and procedures for preparing cytotoxic drugs. The same work practices were evaluated after four months of operational procedures implementation. Concordance between work practices and guidelines was considered to be a quality indicator (guidelines concordance practices number/total number of practices x 100). Results: improvements were observed after operational procedures implementation. An improvement of 6,25% in personal protective equipment practice was achieved by changing second pair of gloves every thirty minutes. The major progress, 10%, was obtained in disinfection procedure, where 80% of tasks are now realized according to guidelines.By now, we hot an improvement of only 1% at drug preparation procedure by placing one cytotoxic drug at a time inside the biological safety cabinet. Then, 85% of practices are according to guidelines. Conclusion: before operational procedures implementation 80,3% of practices were according to the guidelines, while now is 84,4%. This indicates that is necessary to review the procedures frequently in the benefit to reduce the risks associated with handling cytotoxic drugs and maintenance of drug specifications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Dissertação de Mestrado apresentado ao Instituto de Contabilidade e Administração do Porto para a obtenção do grau de Mestre em Auditoria, sob orientação de: Doutora Alcina Dias e coorientação de: Doutora Ana Paula Lopes

Relevância:

60.00% 60.00%

Publicador:

Resumo:

As the wireless cellular market reaches competitive levels never seen before, network operators need to focus on maintaining Quality of Service (QoS) a main priority if they wish to attract new subscribers while keeping existing customers satisfied. Speech Quality as perceived by the end user is one major example of a characteristic in constant need of maintenance and improvement. It is in this topic that this Master Thesis project fits in. Making use of an intrusive method of speech quality evaluation, as a means to further study and characterize the performance of speech codecs in second-generation (2G) and third-generation (3G) technologies. Trying to find further correlation between codecs with similar bit rates, along with the exploration of certain transmission parameters which may aid in the assessment of speech quality. Due to some limitations concerning the audio analyzer equipment that was to be employed, a different system for recording the test samples was sought out. Although the new designed system is not standard, after extensive testing and optimization of the system's parameters, final results were found reliable and satisfactory. Tests include a set of high and low bit rate codecs for both 2G and 3G, where values were compared and analysed, leading to the outcome that 3G speech codecs perform better, under the approximately same conditions, when compared with 2G. Reinforcing the idea that 3G is, with no doubt, the best choice if the costumer looks for the best possible listening speech quality. Regarding the transmission parameters chosen for the experiment, the Receiver Quality (RxQual) and Received Energy per Chip to the Power Density Ratio (Ec/N0), these were subject to speech quality correlation tests. Final results of RxQual were compared to those of prior studies from different researchers and, are considered to be of important relevance. Leading to the confirmation of RxQual as a reliable indicator of speech quality. As for Ec/N0, it is not possible to state it as a speech quality indicator however, it shows clear thresholds for which the MOS values decrease significantly. The studied transmission parameters show that they can be used not only for network management purposes but, at the same time, give an expected idea to the communications engineer (or technician) of the end-to-end speech quality consequences. With the conclusion of the work new ideas for future studies come to mind. Considering that the fourth-generation (4G) cellular technologies are now beginning to take an important place in the global market, as the first all-IP network structure, it seems of great relevance that 4G speech quality should be subject of evaluation. Comparing it to 3G, not only in narrowband but also adding wideband scenarios with the most recent standard objective method of speech quality assessment, POLQA. Also, new data found on Ec/N0 tests, justifies further research studies with the intention of validating the assumptions made in this work.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Despite the availability of guidelines for treatment of heart failure (HF), only a few studies have assessed how hospitals adhere to the recommended therapies. Objectives: Compare the rates of adherence to the prescription of angiotensin-converting enzyme inhibitor or angiotensin II receptor blockers (ACEI/ARB) at hospital discharge, which is considered a quality indicator by the Joint Commission International, and to the prescription of beta-blockers at hospital discharge, which is recommended by national and international guidelines, in a hospital with a case management program to supervise the implementation of a clinical practice protocol (HCP) and another hospital that follows treatment guidelines (HCG). Methods: Prospective observational study that evaluated patients consecutively admitted to both hospitals due to decompensated HF between August 1st, 2006, and December 31st, 2008. We used as comparing parameters the prescription rates of beta-blockers and ACEI/ARB at hospital discharge and in-hospital mortality. Results: We analyzed 1,052 patients (30% female, mean age 70.6 ± 14.1 years), 381 (36%) of whom were seen at HCG and 781 (64%) at HCP. The prescription rates of beta-blockers at discharge at HCG and HCP were both 69% (p = 0.458), whereas those of ACEI/ARB were 83% and 86%, respectively (p = 0.162). In-hospital mortality rates were 16.5% at HCP and 27.8% at HCG (p < 0.001). Conclusion: There was no difference in prescription rates of beta-blocker and ACEI/ARB at hospital discharge between the institutions, but HCP had lower in-hospital mortality. This difference in mortality may be attributed to different clinical characteristics of the patients in both hospitals.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Density is an important component of hot-mix asphalt (HMA) pavement quality and long-term performance. Insufficient density of an in-place HMA pavement is the most frequently cited construction-related performance problem. This study evaluated the use of electromagnetic gauges to nondestructively determine densities. Field and laboratory measurements were taken with two electromagnetic gauges—a PaveTracker and a Pavement Quality Indicator (PQI). Test data were collected in the field during and after paving operations and also in a laboratory on field mixes compacted in the lab. This study revealed that several mix- and project-specific factors affect electromagnetic gauge readings. Consequently, the implementation of these gauges will likely need to be done utilizing a test strip on a project- and mix-specific basis to appropriately identify an adjustment factor for the specific electromagnetic gauge being used for quality control and quality assurance (QC/QA) testing. The substantial reduction in testing time that results from employing electromagnetic gauges rather than coring makes it possible for more readings to be used in the QC/QA process with real-time information without increasing the testing costs.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper analyses the effect of unmet formal care needs on informal caregiving hours in Spain using the two wavesof the Informal Support Survey (1994, 2004). Testing for double sample selection from formal care receipt and theemergence of unmet needs provides evidence that the omission of either variable would causes underestimation of thenumber of informal caregiving hours. After controlling for these two factors the number of hours of care increaseswith both the degree of dependency and unmet needs. More importantly, in the presence of unmet needs, the numberof informal caregiving hours increases when some formal care is received. This result refutes the substitution modeland supports complementarity or task specificity between both types of care. For a given combination of formal careand unmet needs, informal caregiving hours increased between 1994 and 2004. Finally, in the model for 2004, theselection term associated with the unmet needs equation is larger than that of the formal care equation, suggestingthat using the number of formal care recipients as a quality indicator may be confounding, if we do not complete thisinformation with other quality indicators.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Crop-livestock integration represents an interesting alternative of soil management, especially in regions where the maintenance of cover crops in no-tillage systems is difficult. The objective of this study was to evaluate soil physical and chemical properties, based on the hypothesis that a well-managed crop-livestock integration system improves the soil quality and stabilizes the system. The experiment was set up in a completely randomized design, with five replications. The treatments were arranged in a 6 x 4 factorial design, to assess five crop rotation systems in crop-livestock integration, and native forest as reference of soil undisturbed by agriculture, in four layers (0.0-0.05; 0.05-0.10; 0.10-0.15 and 0.15-0.20 m). The crop rotation systems in crop-livestock integration promoted changes in soil physical and chemical properties and the effects of the different systems were mainly detected in the surface layer. The crops in integrated crop-livestock systems allowed the maintenance of soil carbon at levels equal to those of the native forest, proving the efficiency of these systems in terms of soil conservation. The systems influenced the environmental stability positively; the soil quality indicator mineral-associated organic matter was best related to aggregate stability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Density is an important component of hot-mix asphalt (HMA) pavement quality and long-term performance. Insufficient density of an in-place HMA pavement is the most frequently cited construction-related performance problem. This study evaluated the use of electromagnetic gauges to nondestructively determine densities. Field and laboratory measurements were taken with two electromagnetic gauges—a PaveTracker and a Pavement Quality Indicator (PQI). Test data were collected in the field during and after paving operations and also in a laboratory on field mixes compacted in the lab. This study revealed that several mix- and project-specific factors affect electromagnetic gauge readings. Consequently, the implementation of these gauges will likely need to be done utilizing a test strip on a project- and mix-specific basis to appropriately identify an adjustment factor for the specific electromagnetic gauge being used for quality control and quality assurance (QC/QA) testing. The substantial reduction in testing time that results from employing electromagnetic gauges rather than coring makes it possible for more readings to be used in the QC/QA process with real-time information without increasing the testing costs.